• Title/Summary/Keyword: Hand-operated

Search Result 332, Processing Time 0.024 seconds

AN EXPERIMENTAL STUDY ON THE SHAPE OF THE APICAL REGIONS OF ROOT CANALS AFTER INSTRUMENTATION BY VARIOUS ENLARGING INSTRUMENTS (각종(各種) 근관확대기구(根管擴大器具)에 의(依)한 근관형성(根管形成) 후(後) 근단부(根端部) 근관면(根管面)의 형태(形態)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.17-24
    • /
    • 1981
  • The purpose of this study is to compare the shape of the apical regions of root canals after instrumentation by various enlarging instruments. 120 extracted, single-rooted human teeth were seperated into 4 experimental groups. Each group provided 30 teeth for experimental use. Group 1 root canals instrumented by the hand-operated Reamer. Group 2 root canals instrumented by the hand-operated H-file. Group 3 root canals instrumented by the hand-operated K-file. Group 4 root canals instrumented by the automated Giromatic file. The results were as follows: 1. The degree of the roundness of the apical regions of root canal walls: 1) Hand-operated instruments were superior to the automated Giromatic file. 2) The Reamer was the most effective instrument among hand-operated instruments 3) There was little difference between the H-file and the K-file. 2. The degree of the smoothness of the apical regions of root canal walls: 1) Root canal walls instrumented by the hand-operated Reamer, H-file and, K-file were generally smooth, and there was little difference among them. 2) Root canal walls instrumented by the automated Giromatic file showed many irregular canal walls. 3. The existance of organic debris in the apical regions of root canals: All organic debris is not removed from root canals, and there was little difference between hand-operated instruments and the automated Giromatic instrument in removing organic debris.

  • PDF

Prevention of Work-related Musculoskeletal Disorders in Grapes Pinching by Using Electro-motion Scissors Designed Ergonomically

  • Chae, Hye-Seon;Kim, Sung-Cheol;Kim, Kwan-Woo;Lee, Kyung-Suk;Kim, Hoy-Cher;Park, Keun-Sang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.749-755
    • /
    • 2011
  • Objective: The purpose of this study is to assess the reducing effect of workload on developed electro-motion scissors. Methods: To achieve this, we measured the pressure distribution, Joint angle of fingers and JSI(Job Strain Index) for electro-motion scissors and hand-operated scissor in objective assessment and surveyed the uncomfortable degree in subjective assessment. Results: As a result, The peak of pressure in the electro-motion scissors was generally lower than the hand-operated scissors. JSI and overall joint angle of fingers for the electro-motion scissors were remarkably lower than the hand-operated scissors. Also, the subjective uncomfortable degree showed that the uncomfortable point of electro-motion scissors were generally lower than the hand operated scissors. Conclusion: The impact of reducing the work load as well as distributing the pressure around the hand by using electro-motion scissors during grapes pinching was confirmed.

Comparative Study of Sasang Constitutions Diagnostic Accuracy Rate on Measurement Method of Body Shape by IBS-2000 Compensator (IBS-2000보정기기를 이용한 체형측정방법에 따른 사상체질 진단정확률 비교연구)

  • Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.78-89
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method & Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated width 5 places and hand-operated circumference 8 places, Automatic width 5 places) and analyzed the anthropometric data dividing into sex, age, BMI. 1057 patients's data are used in the analysis. 3. Results and Conclusions 1) 5th Width variable which was measured during lying down was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement by Width which was measured during lying down and Width which IBS standing was 40-60%. 3) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating (3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구)

  • Kwon, Suk-Dong;Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Descriptive Survey on the Dimensions and the Characteristics of Korean Hands in General (한국인의 손 치수 및 특성에 관한 연구)

  • Jeong, Hwa-Sik;Jeong, Hyeong-Sik
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.29-44
    • /
    • 2003
  • A variety of research has been conducted on anthropometric dimensions and their applications to various products and space architecture, Also robust research has been conducted on various parts of human body and the possibility of applications. However, research on the specific dimensions regarding fingers and characteristics of hands have rarely been conducted in Korea. In addition, except for the NASA Anthropometric Source Book that suggests measures for specific purposes such as gloves and hand-operated device, almost no literature can be found on this topic, The primary objective of this study was thus to provide anthropometric dimensions of Korean hands and fingers and recommend appropriate product design solutions for human hands. Six hundred Korean male and female subjects aging from 11 to 93 were selected, Thirteen different hands and fingers were measured along with demographic data(e.g., age, stature, weight} to determine the relationships among these obtained data, The results of this study should be considered in ergonomic design for every hand-used products and hand-operated control devices.

Design of a User-Oriented 6-DOF Parallel Haptic Hand Controller (사용자를 고려한 병렬형 6자유도 햅틱 핸드 콘트롤러의 설계)

  • Ryu, Dong-Seok;Kwon, Tae-Yong;Song, Jae-Bok
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.313-318
    • /
    • 2001
  • A haptic hand controller operated by the user's hand can receive information on position and orientation of the hand and display force and moment generated in the virtual environment to the hand. This paper presents a design method for KU-HHC, 6 DOF Korea University-haptic hand controller, which allows separation of workspace from linkage mechanism in consideration of the efficient user operation. First, the 3 DOF mechanism in which all the actuators are mounted on the fixed base is developed by combining a 5-bar linkage and gimbal mechanism. Then, the 6 DOF HHC is designed by connecting the two 3 DOF devices through a handle. This paper presents the forward and inverse kinematics for this device and Jacobian analysis. Improvement of the kinematic characteristics using performance index is also discussed. The hand controller KU-HHC based on this design concept and kinematic analysis was manufactured and shows excellent performance.

  • PDF

Automation of an Interactive Interview System by Hand Gesture Recognition Using Particle Filter

  • Lee, Yang-Weon
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.6
    • /
    • pp.633-636
    • /
    • 2011
  • This paper describes a implementation of virtual interactive interview system. A hand motion recognition algorithm based on the particle filters is applied for this system. The particle filter is well operated for human hand motion recognition than any other recognition algorithm. Through the experiments, we show that the proposed scheme is stable and works well in virtual interview system's environments.

A Study on Thermal Characteristics for Hand Carried Ultrasound System

  • Kim, Jong-Gu;Cho, Young-Jin;Kwack, Kae-Dal
    • Journal of Applied Reliability
    • /
    • v.9 no.2
    • /
    • pp.149-163
    • /
    • 2009
  • This paper intends to suggest a design to reduce the thermal load of a hand-carried ultrasound (HCU) system, with the aim of increasing the product life. To design ways to reduce the heat load, the surface temperatures of key parts of an HCU system were measured as the 4 system cooling fans, which have a direct relation to the system life, were operated normally. When the derating rate of 80% was applied while the fans of the HCU system were operated abnormally, it was observed that the key image processing parts exceeded the surface temperature (TC) with consideration to derating. Since the part surface temperature did not exceed the derated level when the regulated voltage was derated from 12V to 9V, it is expected to lower the operating voltage of the fans to 9V to increase the fan and HCU system lifetime by 1.8 times.

  • PDF