• 제목/요약/키워드: Hand-Held Device

검색결과 62건 처리시간 0.025초

휴대용 화상전송 원격정비 감시시스템의 개발 (A Development of Image Transfer Remote Maintenance Monitoring System for Hand Held Device)

  • 김동완;박성원
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.276-284
    • /
    • 2009
  • In this paper, we develop the image transfer remote maintenance monitoring system for hand held device which can compensate defects of human mistake. The human mistakes always happen when the worker communicate information each other to check and maintenance the equipment of the power plant under bad circumstance such as small place and long distance in power plant. A worker couldn't converse with other when in noisy place like Power plant. So, we make some hand device for handy size and able to converse in noisy place. The developed system can have improvement of productivity through increasing plant operation time. And developed system is composed of advanced H/W(hard ware) system and S/W(soft ware)system. The H/W system consist of media server unit, communication equipment with hand held device, portable camera, mike and head set. The advanced s/w system consist of data base system, client pc(personal computer) real time monitoring system which has server GUI(graphic user interface) program, wireless monitoring program and wire ethernet communication program. The client GUI program is composed of total solution program as pc camera program, and phonetic conversation program etc.. We analyzed the required items and investigated applicable part in the image transfer remote maintenance monitoring system with hand held device. Also we investigated linkage of communication protocol for developed prototype, developed software tool of two-way communication and realtime recording skill of voice with image. We confirmed the efficiency by the field test in preventive maintenance of plant power.

모바일 휴대용 단말기의 지속적 이용에 있어서 기기애착 개념의 역할에 관한 연구 (The role of device attachment in post-adoption of mobile hand-held devices)

  • 권순재;채성욱
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제18권3호
    • /
    • pp.27-46
    • /
    • 2009
  • Korean society frenzy about ubiquitous computing is in a rapid change into so called 'Nomadic' information environment. In many previous studies, a number of intrinsic and extrinsic motivation factors were empirically found to affect users' continuance to use mobile hand-held devices. However, the role of device attachment, a new intrinsic motivation factor with which users are known to care about their own mobile devices personally, in determining users' post-adoption behavior was not explored yet to the full scale. To fill the research void like this, this study proposes a new research model in which device attachment as well as perceived value are positively linked to satisfaction and continuance to use. The statistical results obtained by applying PLS to the valid 137 questionnaires showed that the device attachment has stronger positive influence on satisfaction and continuance to use than the perceived value. Therefore, a practical implication is suggested thai the mobile devices need 10 be designed in a way of arousing users' device attachment more strongly.

여행자 상황 정보 기반 안경형 웨어러블 디바이스 및 핸드헬드 디바이스 투어 가이드 시스템 (A Mobile Tour Guide System using Wearable See-through Device and Hand-held Device based on Shared Touring Context)

  • 김도연;서대일;유병현;고희동
    • 한국HCI학회논문지
    • /
    • 제11권1호
    • /
    • pp.29-38
    • /
    • 2016
  • 모바일 투어 가이드 어플리케이션은 여행 정보를 제공하여 여행자가 여행 중에 주변의 관심 지점(POI; Point of Interest) 을 검색하고 찾아갈 수 있도록 돕는다. 최근 모바일 컴퓨팅 기술이 발전하면서 핸드헬드 디바이스와 웨어러블 디바이스를 여행 정보 검색에 활용하는 사용자가 늘어나고 있지만, 모바일 투어 가이드 어플리케이션들은 디바이스의 특성을 고려하지 않고 여행 정보를 제공한다. 특히 이들 투어 가이드 어플리케이션들은 여행 상황을 공유하지 않기 때문에 여러 모바일 디바이스를 이용하는 여행자는 각각의 디바이스에 여행자의 검색 의도를 별도로 입력해야 하고, 동기화된 여행 정보를 제공받지 못한다. 이러한 문제들을 개선하기 위해 본 논문에서는 디바이스의 특성에 따라 여행 정보를 제공하고 여행 상황을 공유하는 모바일 투어 가이드 시스템을 제안한다. 제안된 시스템은 핸드헬드 디바이스와 안경형 웨어러블 디바이스를 이용하여 여행자에게 여행 정보를 제공하고, 각각의 디바이스가 가진 단점을 상호 보완하면서 여행자를 안내한다. 또한 제안된 시스템은 각각의 디바이스들에 설치된 어플리케이션 사이에 여행 상황을 공유하여 여행자의 입력을 최소화하고, 여행 상황에 맞는 여행 정보를 제공한다.

휴대용 XRF 장치의 검출감도 향상에 관한 연구 (Study for Enhancement of the Detection Sensitivity in Hand-Held X-Ray Fluorescence Device)

  • 김성수;이연승;김도윤;고동섭
    • 한국진공학회지
    • /
    • 제20권6호
    • /
    • pp.409-415
    • /
    • 2011
  • 현재 개발 중인 휴대용 XRF (X-Ray Fluorescence) 장치의 검출감도를 향상시키기 위한 방법을 논의하였다. 대기 기체분자에 의한 강도 손실을 최소화하기 위하여 시료와 검출기 사이에 Vacuum module을 설치하였다. Vacuum module은 대기기체 또는 He 기체를 채울 수 있도록 고안하였다. 그리고 Vacuum module 내부에 He 기체를 채운 상태, 또는 진공상태에서 검출감도의 변화를 조사하였다. 그 결과 다음 3가지 중요한 결과를 얻었다. 첫 번째는, 낮은 에너지 영역(3~4 keV)에서의 XRF 강도가 2~4배 정도 증가하였다. 검출감도의 향상은 검출시간의 단축을 의미하기 때문에, 휴대용 XRF 장치에 있어서 매우 중요한 결과이다. 두 번째는, x-ray emission line의 에너지가 3 keV 이하인 원소의 검출 가능성을 확인하였다. 세 번째는, He 기체를 채운 vacuum module을 사용하면, 휴대용 XRF 장치에 진공밀폐용기를 쓰지 않으면서도 대기기체분자에 의한 흡수를 최소화할 수 있다는 것이다. 세 가지 모두 휴대용 XRF 장치의 개발에 있어서 매우 의미있는 결과로 판단된다.

모바일 기기를 위한 진동촉각 디스플레이와 선호하는 패턴 생성방법 (A Vibrotactile Display for Hand-held Devices and Its Preferable Pattern Generation Method)

  • 양기훈;진연섭;강성철
    • 제어로봇시스템학회논문지
    • /
    • 제20권8호
    • /
    • pp.795-800
    • /
    • 2014
  • In this paper, a vibrotactile pad system, T-mobile, is developed to provide vibrotactile cues for hand-held devices. A grooved and slim design is adapted to the back-side plane of the T-mobile, and the contact part consists of 12 vibrotactile panels which can operate independently and separately. To be isolated among vibrotactile actuators, the surface of the cover is divided into several pieces. Each vibrating module consists of a linear resonant actuator, a section of covering surface, and a vibration isolator. In order to provide spatial and directional information, sensory saltation and phantom sensation are applied to the T-mobile. To evaluate the developed device, two experiments were conducted to test whether directional information and spatial information can be successfully displayed by the device. Additionally, in order to find optimal stimulation by sensory saltation, an empirical test was conducted. As a result, spatial and directional information would be useful for displaying intuitive information for hand-held devices with vibrotactile feedback and reasonable near-optimal value for sensory saltation was obtained.

The Reliability and Validity of a Portable Hand-held Spirometer for the Measurement of Various Lung Functions in Healthy Adults

  • Merve Nur Uygun;Jun-Min Ann;Byeong-Hyeon Woo;Hyeon-Myeong Park;Ha-Im Kim;Dae-Sung Park;In-Beom Jeong
    • Physical Therapy Rehabilitation Science
    • /
    • 제13권2호
    • /
    • pp.179-186
    • /
    • 2024
  • Objective: This study aims to assess the reliability and validity of the new hand-held spirometer as a potential substitute for traditional pulmonary function testing (PFT) devices. Design: Cross-sectional study. Methods: In this study, thirty healthy adults underwent spirometry using both the new hand-held spirometer and the MIR spirometer, which is a standard PFT device. Parameters including peak expiratory flow (PEF), forced expiratory volume in one second (FEV1), and forced vital capacity (FVC) were measured and analyzed for validity and reliability. Inter-rater reliability and validity were evaluated through 95% limits of agreement (LOA) and intraclass correlation coefficients (ICC). Statistical analyses, including the Bland-Altman plots and the ICC, were utilized to assess agreement between the two devices. Results: The new hand-held spirometer exhibited a good agreement with intra-class coefficient (ICC [2,1]) ranging 0.762 to 0.956 and 95% LOA of -1.94 to 1.80 when compared with MIR. The test-retest reliability of the hand-held spirometer analyzed using - ICC [2,1] demonstrated a good level of consistency (ICC [2,1] =0.849-0.934). Conclusions: In conclusion, the study aimed to assess the potential of the new hand-held spirometer as a viable alternative to traditional PFT devices, with a specific focus on its reliability and validity in spirometric measurements. The new hand-held spirometer exhibited good test-retest reliability across all measured variables, suggesting its potential as a valid and reliable tool for simultaneous PFT measurements.

착용환경을 고려한 안테나 설계와 손 부착 시 HAC 지수의 관찰 (A Handset Antenna Design with the Real-Portable Mock-Up and Its HAC with the Hand-Effect)

  • 강승택;최동근;전진수;박정훈
    • 한국위성정보통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.102-106
    • /
    • 2014
  • 본 논문에서는, 이중대역 안테나를 가진, 인체 거치용 단말장치 모사구조의 HAC(보청기 EMC) 지수가 실재환경으로부터 받는 영향에 대한 관찰이 이뤄진다. 첫째, 부착형 이동통신 장치에 필수적인 인접 구조를 고려한 이중대역 내장형 안테나가 설계된다. 이 설계는 모사구조의 제작을 통해 실제의 모습을 갖춘다. 둘째, 이 장치의 HAC 지수는 손에 부착하기 전과 후에 대해 모의시험 및 측정을 통해 얻어진다. 특히, 실재 장치의 전자장 모의시험 결과는 표준 측정법에 의해 타당성이 확인된다. 마지막으로, HAC 기주는 대역, 실장환경, 손(인체) 효과의 관점에서 분석된다.

수지형 체외식 초음파 프로브의 성능 평가 가이드라인 개발 (Development of a Guideline for Performance Evaluation of External Hand-Held Ultrasonic Probe)

  • 김산;황윤수;손대웅;윤순종;이재원;김혁주
    • 한국통신학회논문지
    • /
    • 제39C권10호
    • /
    • pp.896-908
    • /
    • 2014
  • 세계적인 인구 고령화와 생활수준의 향상에 따른 국민들의 건강에 대한 관심이 커지면서 최근 전자의료기기의 시장도 증대되고 있다. 수지형체외식초음파프로브는 허가 신청 건수가 높은 다빈도 허가 심사 대상 의료기기이며 최근 병원 등의 임상분야에서 그 활용도가 높다. 하지만, 수지형체외식초음파프로브의 성능 평가를 위한 국내 기준은 명확하게 마련되지 않은 실정이고, 허가심사 및 품질평가 등을 위한 가이드라인 조차 마련되어 있지 않다. 따라서 본 연구에서는 수지형체외식초음파프로브의 특성, 허가 및 시장현황을 조사하고, 관련 국내 외 규격을 검토하여 성능평가 시험항목, 기준 및 방법을 도출하였으며, 시험검증을 통하여 최종적으로 국제조화되고 국내 실정에 적합한 성능 평가 가이드라인을 마련하였다. 향후 본 연구결과를 의료기기 관련 업체에서 활용함으로써 수지형체 외식초음파프로브의 품질 및 성능 향상을 도모하고, 허가를 위한 심사 평가의 일관성을 확보할 수 있을 것으로 기대된다.

볼 기반의 모바일 햅틱 인터페이스 디자인 (Design of Ball-based Mobile Haptic Interface)

  • 최민우;김정현
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2009년도 학술대회
    • /
    • pp.122-128
    • /
    • 2009
  • 이 논문에서는 모바일 환경에서 촉각적 사용자 체험 (User Experience)을 향상 시킬 수 있도록 디자인된 새로운 방식의 핸드헬드 볼 기반의 햅틱 인터페이스 "TouchBall" 을 소개하고 그 성능을 평가한다. 작은 모바일 디바이스(모바일 폰, PDA, PMP 등)에 적당하도록 볼 기반의 기계적 메커니즘을 사용하여 작은 회전력으로도 높은 감도의 다양한 촉감을 손에 전달할 수 있도록 구성되어 있다. 제안하는 인터페이스를 적용한 프로토타입 버전을 구현하였고, 정신물리학적 실험을 통해 사람의 감각 인식의 가장 기본적인 척도가 되는 감지 역치를 측정하였다. 그리고 구현 가능한 다양한 촉각 패턴들의 인식강도를 절대적 강도추정 방법으로 측정하여 정확도와 인식강도를 알아보고 그 응용 가능성을 찾아보았다.

  • PDF

A Measurement System for 3D Hand-Drawn Gesture with a PHANToMTM Device

  • Ko, Seong-Young;Bang, Won-Chul;Kim, Sang-Youn
    • Journal of Information Processing Systems
    • /
    • 제6권3호
    • /
    • pp.347-358
    • /
    • 2010
  • This paper presents a measurement system for 3D hand-drawn gesture motion. Many pen-type input devices with Inertial Measurement Units (IMU) have been developed to estimate 3D hand-drawn gesture using the measured acceleration and/or the angular velocity of the device. The crucial procedure in developing these devices is to measure and to analyze their motion or trajectory. In order to verify the trajectory estimated by an IMU-based input device, it is necessary to compare the estimated trajectory to the real trajectory. For measuring the real trajectory of the pen-type device, a PHANToMTM haptic device is utilized because it allows us to measure the 3D motion of the object in real-time. Even though the PHANToMTM measures the position of the hand gesture well, poor initialization may produce a large amount of error. Therefore, this paper proposes a calibration method which can minimize measurement errors.