• Title/Summary/Keyword: Hand radiography

Search Result 59, Processing Time 0.024 seconds

Comparative Study of Radiation Exposure using Entrance Skin Dose Calculation Technique in Diagnostic X-Ray Radiography (입사 표면 선량 계산에 따른 진단용 X-선 촬영시 피폭선량 비교 연구)

  • Han, Jae-Bok;Choi, Nam-Gil;Sung, Ho-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.357-363
    • /
    • 2011
  • The aim of this study is to compare radiation dose in diagnostic X-ray radiography and calculated by different mathematical equation. The result of ESDs direct measurement and that calculated by Mori NDD-M shows the biggest difference. On the other hand, equation by Edmonds shows the lowest difference of ESDs. Also, Rectification due to the difference between direct dose measurement and calculation method commutated three-phase, single phase and inverter type, show less difference in the drive way. In conclusion, this study can be helpful for expecting radiation dose-exposure and control exposure parameters for the diagnostic x-ray radiography.

Bilateral Osteoarthritis of Coxofemoral Joint in a Thoroughbred Horse

  • Jeong, Hyohoon
    • Journal of Veterinary Clinics
    • /
    • v.35 no.5
    • /
    • pp.247-249
    • /
    • 2018
  • A 3-year-old black Thoroughbred colt weighing 500 kg was admitted to the Equine Hospital of Korea Racing Authority (KRA) due to the chronic gait abnormality of the hindlimbs. The history revealed that the patient had run and fallen onto the fence of the farm about at the age of 1 year old and the lameness had been worsening insidiously since the accident. The degree of lameness was 2/5 in accordance with the AAEP lameness grading system in both hindlimbs at hand walking and trot. The lameness was exacerbated at lunging clockwise and counterclockwise on both hindlimbs. The definitive diagnosis of the bilateral osteoarthritis of coxofemoral joint was established using radiography under general inhalation anesthesia. The prognosis was considered to be poor with low expectancy for racing and the colt was expelled from the racecourse eventually. The clinicians are required to consider the possibility of osteoarthritis of coxofemoral joint presented with chronic hindlimb lameness although it is rare. This is the first report on the bilateral osteoarthritis coxofemoral joint in Republic of Korea.

Infection Control of Computed Radiography Portable in Radiology (영상의학과 이동촬영장비의 감염 관리)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2017
  • The purpose of this study is to prevent infection in the hospital by computed radiography portable and to provide basic data on infection-related education by investigating bacterial contamination level of computed radiography portable equipment using IP cassette. The results suggest that IP cassette No. 1 is infected with CNS and VRE, no. 2 with CNS, No. 3 with CNS and Pseudomonas aeruginosa, No. 4 with CNS, No. 5 with CNS and Bacillus sp., and No. 6 with enterococcus faecium. Enterococcus faecium and bacillus sp. were detected from the IP reader and Acinetobacter baumannii was detected on the mobile handle; Bacillus sp. on the control buttons, CNS and Bacillus sp. from the irradiation control handle, Acinetobacter baumannii on the x-ray generation switch, and CNS on the barcode scanner. In addition, Bacillus sp. Acinetobacter baumannii was found on the IP cassette mobile table and CNS and bacillus sp. were found on the lead apron. Acinetobacter baumannii and CNS were detected from the medical gloves worn by a radiological technologist during radiography. This suggests that IP cassette should be sterilized after use as it can hand over bacteria to IP reader and IP mobile table. Medical gloves that are in direct contact with patients should also be replaced after using them once and other supplies such as x-ray generation switch and lead apron should thoroughly be sterilized to prevent infection due to radiography as they are in a lot of contact with patients.

Image Comparison of Curved and Flat Panel Detectors for the Application of Digital Radiography Testing in Pipe Welds (배관 원둘레 이음 용접부의 디지털 방사선 투과 검사 적용을 위한 커브드 및 평면형 검출기의 영상 비교)

  • Yang, Jin-Wook;Cho, Kap-Ho;Nam, Mun-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.585-594
    • /
    • 2022
  • The detector for digital radiography testing, which is currently mainly used, consists of a detector with a flat structure, making it impossible to fully adhere to the digital radiography testing of the test object with curvature. In this study, a curved panel detector capable of adhering to curvature was fabricated to improve the quality of the digital image during the digital radiography testing of piping welds at industrial sites, and digital radiography images using flat and curved panel detectors were obtained for 6in pipes with different nominal thickness. As a result of the experiment, it was confirmed that the flat panel detector does not fully adhere to the pipe, resulting in a gap between the outer part of the pipe and the detector, resulting in a difference in the unsharpness and diffusion of the digital image. On the other hand, it was confirmed that the curved panel detector minimizes the gap between the pipe outer part and the detector, so that digital image diffusion is less than that of the flat panel detector. The higher the confidence of the image, the lower the quality and error in reading, so it is believed that higher quality images can be obtained than conventional flat panel detectors when using detectors that can be closely attached to the inspection object.

Free Hand Pedicle Screw Placement in the Thoracic Spine without Any Radiographic Guidance : Technical Note, a Cadaveric Study

  • Hyun, Seung-Jae;Kim, Yong-Jung J.;Cheh, Gene;Yoon, Seung-Hwan;Rhim, Seung-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.1
    • /
    • pp.66-70
    • /
    • 2012
  • Thoracic pedicle screw fixation techniques are still controversial for thoracic deformities because of possible complications including neurologic deficit. Methods to aid the surgeon in appropriate screw placement have included the use of intraoperative fluoroscopy and/or radiography as well as image-guided techniques. We describe our technique for free hand pedicle screw placement in the thoracic spine without any radiographic guidance and present the results of pedicle screw placement analyzed by computed tomographic scan in two human cadavers. This free hand technique of thoracic pedicle screw placement performed in a step-wise, consistent, and compulsive manner is an accurate, reliable, and safe method of insertion to treat a variety of spinal disorders, including spinal deformity.

Thickness Evaluation of Pipeline Using Density Profile on a Radiograph (방사선투과필름에서 Density Profile을 이용한 배관의 두께 평가)

  • Lee, Sung-Sik;Jang, Byoung-Gyu;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.483-489
    • /
    • 2002
  • The computer simulation has been done for non-insulated and insulated pipes which are vacant or half filled with liquid. The simulation results showed that the density profile on the radiography is continuous and symmetrical around the center of pipe in the case of vacant pipe. On the other hand the density profiles are not symmetrical and depend on geometrical setting for radiography in the case of half filled pipes. Finally, experimental testing on a non-insulated carbon steel pipe with artificial notches of different depth is carried out using Ir-192 and industrial film. Comparing the measured density profile on the radiograph to the calculated one, it has been shown that it is possible to evaluate thickness variation by measuring density profile on a radiograph.

Mycoplasma pneumoniae infection in patients with Kawasaki disease

  • Lee, Mi-Na;Cha, Jie-Hae;Ahn, Hye-Mi;Yoo, Jeong-Hyun;Kim, Hae-Soon;Sohn, Se-Jung;Hong, Young-Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.3
    • /
    • pp.123-127
    • /
    • 2011
  • Purpose: Kawasaki disease (KD) is the main cause of acquired heart disease in children. In addition to cardiovascular involvement, many complications have been recognized in KD. However, respiratory complications have been rarely reported. We investigated the differences in clinical characteristics, laboratory findings, radiography findings, and echocardiography findings of Mycoplasma pneumoniae infection and other types of pneumonia in KD patients. Methods: Among 358 patients with KD, 54 developed concurrent pneumonia. Among the 54 patients, 12 (22.2%) with high titers of anti-M. pneumoniae antibody (AMA) (>1:640) were grouped in the M. pneumoniae group and 42 were included in the control group. Serum AMA was measured in each patient. Clinical laboratory findings and total duration of fever were analyzed. Results: The duration of fever, serum hemoglobin, white blood cell count, platelet count, erythrocyte sedimentation rate, C-reactive protein level, albumin level, and the incidence of coronary arterial lesions showed no statistical difference in the 2 groups. Neutrophil count was significantly higher in the M. pneumoniae group than in the control group. Among various radiography findings observed in pneumonia, consolidation and pleural effusion were more frequent in the M. pneumoniae group than in the control group. On the other hand, parahilar peribronchial opacification, diffuse interstitial lesion, and normal findings prevailed in the control group. Conclusion: KD patients can have concurrent infections, especially pulmonary symptoms. The cause of KD is likely to be associated with M. pneumoniae infection. Thus, immediate treatment of M. pneumoniae infection in KD patients is very important.

Study on the Image Quality Comparison between in Digital RT and Film RT (용접부에 대한 디지털 방사선투과영상과 필름 방사선투과영상의 상질 비교에 관한 연구)

  • Park, Sang-Ki;Ahn, Yean-Shik;Gil, Doo-Song
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.391-397
    • /
    • 2011
  • Conventional film radiographic test has been generally and widely used in the inspection on the weldment for quality assurance. On the other hand, since the analog RT is well known for typical time and cost consuming method with complex process of inspection, the industry has researched various ways how to improve radiographic test technology. In this study, we verified the fact that digital RT provides a lot more benefit in effectively detecting defects, ever film details, through digital processing of image enhancement, compared to film RT. As a result, we reached conclusion that digital RT is positively able to replace the film RT in industry in part or in whole.

The reduction methods of operator's radiation dose for portable dental X-ray machines

  • Cho, Jeong-Yeon;Han, Won-Jeong
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.160-164
    • /
    • 2012
  • Objectives: This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. Materials and Methods: Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. Results: The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. Conclusions: When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.

Assessment of Midpalatal Suture Maturation by Skeletal Maturity on Hand Wrist Radiographs (성장기 아동의 수완부 골 성숙도를 이용한 정중구개봉합 성숙도 평가)

  • Yu, Dayeol;Kim, Donghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.31-41
    • /
    • 2021
  • The aim of this retrospective study was to evaluate the correlation between the midpalatal suture maturation and skeletal maturation in growing children aged 7 - 15 years and predict the maturational stages of the midpalatal suture corresponding to skeletal maturity assessed by the skeletal maturation indicators (SMI) and middle phalanx of the third finger (MP3) stages. The group of this retrospective study was consisted of randomly selected 132 male and 135 female in age from 7 - 15 years. The maturation of the midpalatal suture was evaluated by using images from cone-beam computed tomography (CBCT) while the skeletal age was assessed by hand-wrist radiography. CBCT images and hand-wrist radiographs used in this study were obtained from all subjects for orthodontic diagnosis before orthodontic treatment. The maturational stages of the midpalatal suture showed strong correlations with both SMI and MP3 stages. The correlation between the midpalatal suture maturation and SMI (Spearman's correlation coefficient, ϒS = 0.905, p < 0.05) was slightly greater than that of MP3 stages (ϒS = 0.830, p < 0.05). There was a positive significant correlation between the midpalatal suture maturation and chronological age (ϒS = 0.868,p < 0.05). CBCT for evaluation of the midpalatal suture maturational stages may be unnecessary in every pediatric patients because SMI and MP3 stages were both replaceable useful methods for assessing maturation of the midpalatal suture before orthopedic treatment. In this retrospective study, the diagnostic reliability of the SMI method for estimating midpalatal suture maturation showed better reliability than the MP3 method.