Browse > Article
http://dx.doi.org/10.3340/jkns.2012.51.1.66

Free Hand Pedicle Screw Placement in the Thoracic Spine without Any Radiographic Guidance : Technical Note, a Cadaveric Study  

Hyun, Seung-Jae (Department of Neurosurgery, Spine Center, Seoul National University Bundang Hospital, Seoul National University College of Medicine)
Kim, Yong-Jung J. (Department of Neurosurgery, Asan Medical Center, University of Ulsan College of Medicine)
Cheh, Gene (Department of Orthopedic Surgery, Wooridul Spine Hospital)
Yoon, Seung-Hwan (Department of Neurosurgery, College of Medicine, Inha University)
Rhim, Seung-Chul (Department of Orthopaedic Surgery, Spine Service, Columbia University College of Physicians and Surgeons)
Publication Information
Journal of Korean Neurosurgical Society / v.51, no.1, 2012 , pp. 66-70 More about this Journal
Abstract
Thoracic pedicle screw fixation techniques are still controversial for thoracic deformities because of possible complications including neurologic deficit. Methods to aid the surgeon in appropriate screw placement have included the use of intraoperative fluoroscopy and/or radiography as well as image-guided techniques. We describe our technique for free hand pedicle screw placement in the thoracic spine without any radiographic guidance and present the results of pedicle screw placement analyzed by computed tomographic scan in two human cadavers. This free hand technique of thoracic pedicle screw placement performed in a step-wise, consistent, and compulsive manner is an accurate, reliable, and safe method of insertion to treat a variety of spinal disorders, including spinal deformity.
Keywords
Pedicle screw placement; Thoracic spine; Surgical anatomy; Free hand technique; Surgical technique; Cadaveric study;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
연도 인용수 순위
  • Reference
1 Amiot LP, Lang K, Putzier M, Zippel H, Labelle H : Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine (Phila Pa 1976) 25 : 606-614, 2000   DOI   ScienceOn
2 Brown CA, Lenke LG, Bridwell KH, Geideman WM, Hasan SA, Blanke K : Complications of pediatric thoracolumbar and lumbar pedicle screws. Spine (Phila Pa 1976) 23 : 1566-1571, 1998   DOI   ScienceOn
3 Cotrel Y, Dubousset J, Guillaumat M : New universal instrumentation in spinal surgery. Clin Orthop Relat Res 227 : 10-23, 1988
4 Esses SI, Sachs BL, Dreyzin V : Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine (Phila Pa 1976) 18 : 2231-2238; discussion 2238-2239, 1993   DOI   ScienceOn
5 Kim KD, Johnson JP, Babbitz JD : Image-guided thoracic pedicle screw placement : a technical study in cadavers and preliminary clinical experience. Neurosurg Focus 10 : E2, 2001
6 Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD : Free hand pedicle screw placement in the thoracic spine : is it safe? Spine (Phila Pa 1976) 29 : 333-342; discussion 342, 2004   DOI   ScienceOn
7 Kim YJ, Lenke LG, Cheh G, Riew KD : Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs : a comparison with computerized tomography. Spine (Phila Pa 1976) 30 : 2084-2088, 2005   DOI   ScienceOn
8 Kuntz C 4th, Maher PC, Levine NB, Kurokawa R : Prospective evaluaTapping tion of thoracic pedicle screw placement using fluoroscopic imaging. J Spinal Disord Tech 17 : 206-214, 2004   DOI   ScienceOn
9 Li G, Lv G, Passias P, Kozanek M, Metkar US, Liu Z, et al. : Complications associated with thoracic pedicle screws in spinal deformity. Eur Spine J 19 : 1576-1584, 2010   DOI   ScienceOn
10 Liljenqvist UR, Halm HF, Link TM : Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine (Phila Pa 1976) 22 : 2239-2245, 1997   DOI   ScienceOn
11 Liljenqvist UR, Link TM, Halm HF : Morphometric analysis of thoracic and lumbar vertebrae in idiopathic scoliosis. Spine (Phila Pa 1976) 25 : 1247-1253, 2000   DOI   ScienceOn
12 Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB : Complications associated with pedicle screws. J Bone Joint Surg Am 81 : 1519-1528, 1999   DOI
13 West JL 3rd, Ogilvie JW, Bradford DS : Complications of the variable screw plate pedicle screw fixation. Spine (Phila Pa 1976) 16 : 576-579, 1991   DOI   ScienceOn
14 Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP : Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 32 : E56-E64, 2007   DOI   ScienceOn
15 Sarlak AY, Tosun B, Atmaca H, Sarisoy HT, Buluc L : Evaluation of thoracic pedicle screw placement in adolescent idiopathic scoliosis. Eur Spine J 18 : 1892-1897, 2009   DOI   ScienceOn
16 Suk SI, Kim WJ, Lee SM, Kim JH, Chung ER : Thoracic pedicle screw fixation in spinal deformities : are they really safe? Spine (Phila Pa 1976) 26 : 2049-2057, 2001   DOI   ScienceOn