• Title/Summary/Keyword: Hand exposure

Search Result 504, Processing Time 0.024 seconds

Shielding Effect of Radiation Protector for Interventional Procedure (중재적 방사선 분야 방호용구 차폐효과)

  • Ko, Shin-Kwan;Kang, Byung-Sam;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.213-219
    • /
    • 2007
  • The purpose of this study is to evaluate shielding effect of radiation protector for interventional radiologists in procedures by measuring inside and outside of radiation protector. In this study, we measured the radiation dose of 4 interventional radiologists during TACE and PTBD procedure for 4 month(2005.05-2005.09). Absorbed dose were measured by TLD placed underneath and over radiation protector such as Goggle, Thyroid protector, Apron and placed on the 4th finger of Hand. In addition, we measured background radiation dose in the control room using TLD. During TACE procedure, using 0.07 mmPb Goggle decreased average 53.8% of radiation dose rate in continuous fluoroscopic mode and decreased average 77.6% of radiation dose rate in pulse fluoroscopic mode. Using 0.5 mmPb Thyroid protector decreased average 88.9% of radiation dose rate in continuous fluoroscopic mode and decreased average 92.8% in pulse fluoroscopic mode. During PTBD procedure, using 0.07 mmPb Goggle decreased radiation dose rate average 62.7%, 87.9% by 0.5 mmPb Thyroid protector, 90.5% by 0.5 mmPb Apron. The average fluoroscopic time of PTBD was 6.14 min. shorter than TACE procedure, but radiation exposure dose rate of PTBD was 3 times higher in total body dose, and 40 times higher in hand dose rate than TACE. Interventional radiologists must wear thicker protector recommended over 0.5 mmPb. Also, they must use lead Goggle during interventional procedure. Abdomen dose decreased average 38.4% by drawing a lead curtain under the patient's table, therefore, they must draw a lead curtain to shield scattering ray. Radiation exposure dose decreased average 59.0% by using pulse fluoroscopic mode. So radiologists would better use pulse fluoroscopic mode than continuous fluoroscopic mode to decrease exposure dose.

  • PDF

Changes of Hepatic Cyclohexane Metabolizing Enzyme Activities and Its Metabolites in Serum and Urine after Cyclohexane Treatment

  • Kim Ji-Yeon;Jeon Tae-Won;Lee SangHee;Chung Chinkap;Joh Hyun-Sung;Lee Sang-Il;Yoon Chong-Guk
    • Biomedical Science Letters
    • /
    • v.11 no.4
    • /
    • pp.509-515
    • /
    • 2005
  • This study was conducted to determine the kinetics of cyclohexane metabolites (the biomarker on cyclohexane exposure), the changes of hepatic cyclohexane metabolizing enzyme activities and the metabolites of cyclohexane in urine or serum. The rats were sacrificed at 2, 4, 8, 12 and 24 hr after administration of one dose of cyclohexane (1.56 g/kg body weight, i.p.). The metabolites of cyclohexane in urine were identified as cyclohexanol, cyclohexanone, trans-l,2-cyclohexanediol and 1,4-cyclohexanediol with cyclohexane metabolite being 124.00, 0.78, 23.28 and 2.75 (g/g of creatinine, $1\times10^{-3}$). Most of the cyclohexanol and trans-l,2-cyclohexanediol were determined to be in the form of $\beta-glucuronide$ conjugates, whereas cyclohexanone and 1 ,4-cyclohexanediol were found as free forms. In toxicokinetics of serum cyclohexane metabolites, cyclohexanol showed a rapid increase, reaching the plateau at 4 hr, after this time rapidly decreased throughout 24 hr. Changes of cyclohexanone also showed the similar pattern with cyclohexanol except somewhat lower concentration. Trans-l,2-cyclohexanediol, however, showed a gradual increase until 12 hr with the continued same levels throughout 24 hr. On the other hand, 1,4-cyclohexanediol was detected as trace levels at 4 and 12 hr, respectively. The administration of cyclohexane led to a significant increase of hepatic aniline hydroxylase activity from 2 to 8 hr. The activity of hepatic alcohol dehydrogenase showed a significant increase at 4 hr and then were recovered to the level of the control at 24 hr. On the other hand, there were no differences in liver weightlbody weight between the control and cyclohexane-treated animals. However, there were the changes of aniline hydroxylase and alcohol dehydrogenase activities on time-dependent pattern after cyclohexane treatment, which influence on the degree of cyclohexane metabolites both in blood and urine. These results suggest that differential determination of cyclohexane metabolites in urine and serum may be able to be as a biomarker of cyclohexane-exposure in the body. But in this fields further study is needed.

  • PDF

Validity Assessment of Self-reported Smoking Status: Results from the Korean National Environmental Health Survey (KoNEHS) 2009-2011 (흡연상태에 관한 자가보고 설문의 타당도 평가: 제1기(2009-2011) 국민환경보건기초조사 자료 분석)

  • Choi, Wookhee;Park, Kyung Hwa;Kim, Hyun Jeong;Ryu, Jungmin;Yu, Seung Do;Choi, Kyunghee;Kim, Suejin
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.492-501
    • /
    • 2014
  • Objectives: The purpose of this study was to assess the validity of self-reported cigarette smoking status and investigate factors associated with the accuracy self-reported and measured urinary cotinine in Korean adults. Methods: We used data from the $1^{st}$ Korean National Environmental Health Survey (2009-2011) among adults aged ${\geq}19$ years (N=6,246). The survey examined self-reported smoking status, and urinary cotinine was regarded as the biomarker of exposure to tobacco smoke. Urinary cotinine was analyzed using a gas chromatography-mass spectrometry (GC/MS) and data analysis was conducted using IBM SPSS version 20.0, which uses the sample weight and calculates variance estimates to adjust for the unequal probability of selection into the survey. Results: We calculated a cut-off point (53.3 ug/L) by using a ROC (Receiver Operating Characteristic) curve. The smoking prevalence was 24.6% based on self-reported data and 28.2% based on urinary cotinine concentrations. When we assessed the agreement between self-reported and urinary cotinine, we found an average agreement of 97.7% among self-reported smokers and 94.5% among self-reported non-smokers. Among self-reported smokers, factors affected the discrepancy were age, household economic status and average number of cigarettes smoked per day. On the other hand, gender, former smoking experience, and exposure to SHS (second hand smoke) were associated with discrepancies among self-reported non-smokers. Conclusion: These results suggest that self-reported data on smoking status provide a valid estimate of actual smoking status. In future research, we will conduct a continuous monitoring study for reliability verification of the data to reduce potential interpretation errors.

Relationship between Prevalence of Musculoskeletal Symptoms and Occupational and Personal Factors among Street Cleaners (일부 거리환경미화원의 근골격계 증상 유병률과 직업적 및 개인적 요인의 관련성)

  • Jung, Suk-Chul;Lee, Kyung-Sun;Jung, Myung-Chul;Lee, In-Seok;JungChoi, Kyung-Hee;Bahk, Jin-Wook;Kim, Hyun-Joo
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.169-179
    • /
    • 2010
  • The aim of this study was to investigate occupational and individual risk factors and working conditions in relation to musculoskeletal symptoms in street cleaners. Investigation was conducted through a survey of 395 male street cleaners employed by the government office in Seoul, Gyeonggi and Chung-Nam from July to August of 2009. The control group was comprised of 143 male drivers and security guards. Risk factors for musculoskeletal symptoms in street cleaners were investigated by multiple logistic regression analysis and also evaluated ergonomic risk factors by assessing working conditions of 4 street cleaners. As a result of symptom questionnaires, all of the prevalent rates of musculoskeletal symptoms in street cleaners had significantly higher results than those of the control group(p<0.05). On binary logistic regression analysis of musculoskeletal symptoms, street cleaners showed significant higher odds ratio as 18.84(95%CI: 6.56-54.12) in the arm/elbow, 10.49(95%CI: 4.29-25.65) in the hand/wrist compared to the control group. Both absence of rest breaks and exposure to ergonomic risk factors showed to be important internal risk factors of musculoskeletal symptoms among street cleaners. The exposure levels of QEC(Quick exposures checklist) in street cleaners were revealed to be higher on the shoulder/arm, wrist/hand, and neck than back, or from stress. The findings appear to show that street cleaners were high-risk group of work-related musculoskeletal disorders. Therefore street cleaners require a holistic interventional strategy, including adequate arrangement of rest breaks, improvement of working tools and control of individual risk factors such as obesity and smoking.

Entrance Skin Dose and Image Quality Evaluation According to Use Grid Radiography for the Extremity in FPD System (FPD System에서 상.하지 촬영 시 격자에 따른 환자 선량 및 화질 평가)

  • Lee, In-Ja;Yeo, Young-Bok;Lee, Tae-Sung
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.341-348
    • /
    • 2010
  • By accessing the current status of FPD system use in the hospitals located in Seoul and Gyeonggi Province as well as the entrance skin dose and the image quality evaluation realized by C-D Phantom, and the image assessment by the medical professionals regarding the radiography for the extremity, the following results were derived. 1. According to the evaluation made in the actual use of FPD system (12 machines), the grid ratio varied from 8:1 to 13:1, and 6 machines used the grid ratio with 12:1, realizing the largest number. Among the machines, there were 8 machines that allowed a removable grid while 3 machines did use a removable grid (25.0%). 2. When it came to the equipments used for the experiment, it showed that the amount of the entrance skin dose increased from 4.13 times up to 4.79 times with the grid use. 3. The difference in the entrance skin dose depending on the changes in the exposure condition(0.5times or 2.0times) was not significantly different regardless of the patients' thickness. 4. In terms of the image quality depending on C-D Phantom, the grid use was distinguished well. However, the images were well distinguishable as the exposure condition got increased. 5. In the clinical assessment, the grid use was less effective for the Hand PA, which was considered to shoot a thin body part. It was evaluated that the grid use was preferred for the Knee AP, which was shooting for a relatively thick body part. Nonetheless, 3 out of 5 people said that they would not use the grid if the entrance skin dose to reduced.

Sion Sono's Films and Religion in Terms of the 'Gaze' : Fantasy, Desire, and Love (소노 시온 영화와 '응시'의 종교: 환상·욕망·사랑)

  • Park, Kyutae
    • The Critical Review of Religion and Culture
    • /
    • no.25
    • /
    • pp.77-122
    • /
    • 2014
  • A Japanese director Sion Sono(園子溫, born in 1961), who is not so familiar to us yet, has been depicting the world of violence and sexuality filled with poetic and philosophical messages through the shockingly impressive works such as Strange Circus(2005), Love Exposure(2008), Cold Fish(2010), Guilty of Romance(2011), and so forth after the great success of Suicide Circle(2001) and its second film Noriko's Dinner Table(2005). In addition to these, he has also presented a kind of realistic visions in much more direct ways by Himizu(2011) or Land of Hope(2013) after 3 11 disaster. The purpose of this paper is to try a psychoanalytic interpretation of Sion Sono's film, centering on his Guilty of Romance(愛のむきだし), in terms of the concepts of Jacques Lacan(1901-1981), for example, gaze, objet petit a, fantasy, desire, the imaginary-the symbolic-the real, jouissance, etc. In so doing, this paper will pay special attention to the discourse of love on one hand, exploring the way how to show any new perspective to the religious studies by reading film and religion in association with Lacan on the other hand.

A Study on the Environmental Condition and Safety in Dental Radiography Room (치과방사선 촬영실의 환경 및 안전성에 관한 연구)

  • Park, Il-Soon;Lee, Kyung-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.49-64
    • /
    • 2004
  • This study is designed to conduct a questionnaire research into the safety control and the actual condition of radiography by working with dentistry belonging to university hospitals, dental hospitals and dental clinics for three months ranging from August, 2003 to October, 2003. The researcher came to the following conclusions. 1. The research on the current condition of possessed radiational equipment shows that 61.2 percent of the subjects had one intraoral radiation medicine and that 70.1 percent of the subjects had more than one extraoral radiation medicine and that 37.3 percent of the subjects had more than one digital radiation medicine. 2. Most of intraoral radiography (82.1%) was conducted by dental hygienists, and 7.5 percent of intraoral radiography was conducted by nurse aids. On the other hand, most of extraoral radiography (76.6%) was conducted by dental hygienists and digital radiography was conducted by dental hygienists(60.6%), dentists(32.0%) and radiographer(80.0%). 3. The less-than 1-meter-long distance between cone and the radiographer accounted for 44.8 percent. And the more-than 1.6-meter-long distance accounted for no more than 13.4 percent. The exposure time per standard film which was adjusted to each part accounted for 71.6 percent. Fixing the film on the part of healthy patients accounted for 76.1 percent. Fixing the film of elderly patients and children patients by the radiographer accounted for 43.3 percent. 4. The average daily photographing frequency of standard films stood at six to ten pieces(31.3%), and the average weekly photographing frequency of bitewing films stood at less than one piece(47.8%), and the dentistries where bitewing films were not employed accounted for 25.4%. The subjects whose average weekly photographing freqeuncy of occlusal films stood at less than a piece accounted for 59.7 percent. The dentistries whose average weekly photographing frequency of pediatric films stood at one to five pieces accounted for 41.8 percent. In case of panorama & cephalo, one to five pieces on a weekly average accounted for 36.2 percent. The dentistries whose average daily photographing frequency of digital radiation medicine stood at less than 1 piece accounted for 40.0 percent. 5. The research on the use of protective clothes shows that pregnant ·women only accounted for 31.3 percent. In regard to the use of protective clothes in case of the radiographers fixing films, the cases where no protective clothes were employed accounted for 88.1 percent. The reason was said to he attributable to the trouble related to wearing the clothes(54.2%). 6. The survey on the measurement of exposure dose shows that the cases where no measurement was made accounted for 76.1 percent. As far as the measurement methods of exposure dose was concerned, the employment of film badge accounted for 68.8 percent. The subjects turned out to conduct measurement of exposure dose every third month, which accounted for 43.8 percent. The barriers to the measurement of measurement of exposure dose were attributable to the recognition that a little amount of exposure dose need not be measured(29.9%). 7. The survey on the distinction of radiation rooms and clinic rooms reveals that the cases where radiation rooms exclusively existed accounted for 67.2 percent. 43.3 percent of the subjects turned out to have only one protective garment, and 49.3 percent of the subjects proved to conduct a periodical checkup of radiational equipment. The survey on the examination certificates of radiational generators and protective facilities indicates that 80.6 percent of the subjects had the certificates. The research also shows that the subjects with the marks indicating the radiational areas accounted for 70.1 percent. And trustees turned out to handle developing solutions and fixing solutions.

  • PDF

Association between Perceived Susceptibility to Fine Dust Exposure and Wearing Masks, Attitude toward Respiratory Disease Prevention Education in Farmers (농업인의 미세먼지 노출에 대한 인지된 감수성과 마스크 착용 및 호흡기질환 예방교육 참여 태도와의 연관성)

  • Jung, HyeJeong;Lee, YunJin;Lee, SooYeon;Han, JiYoung;Kim, YangWoo;Lee, Soo-Jin
    • Journal of agricultural medicine and community health
    • /
    • v.46 no.2
    • /
    • pp.78-88
    • /
    • 2021
  • Objectives: This study aimed to investigate health risk awareness pertaining to fine dust exposure and the use of face masks in farmers, as well as their attitude toward education regarding fine dust-related respiratory disease prevention. Methods: In total, 295 farmers were interviewed in a survey using a structured questionnaire to obtain data on general characteristics, farming-related characteristics, health risk awareness pertaining to fine dust exposure, attitude toward education on fine dust-related respiratory disease prevention and the use of face masks. This study was analyzed the correlation between the perceived susceptibility to fine dust exposure and willingness to participate in education on fine dust-related respiratory disease prevention. Results: The mean score for perceived susceptibility to fine dust exposure was 3.8 (out of 5), and the participants were highly willing to receive education on fine dust-related respiratory disease prevention. In Multiple response analysis of reactions to exposure to fine dust generated during work, 221 participants responded that they practiced at least one preventive action; participants gave a positive response to "wearing masks" (56.1%), "personal hygiene, such as hand washing." (52.9%). In terms of education methods, 94 (33.6%) participants preferred to learn online or via text messages. Conclusions: The significant correlation between the perceived susceptibility to fine dust exposure and willingness to participate in education on fine dust-related respiratory disease prevention shows the importance of promoting education on prevention. The results of this study can help understand as reference for education on fine dust-related respiratory disease prevention.

Application of Nd-YAP laser to the conventional treatment of periodontal and endodontic combined lesions (Nd-YAP laser를 적용한 치주-근관 복합병소의 치료에 대한 고찰)

  • Kang, He-Kyong;Yoon, Ho-Jung
    • The Journal of the Korean dental association
    • /
    • v.47 no.8
    • /
    • pp.479-486
    • /
    • 2009
  • Purpose: The aim of this study was to show the clinical results of combination of Nd-YAP (1340nm) laser therapy with conventional endodontic and periodontal treatment. Materials and Methods: Four patients with chronic advanced periodontitis and endodontic infection were treated with conventional treatment and Nd-YAP laser therapy. Occlusal adjustment and splinting were done for stabilization of the teeth with severe horizontal and vertical mobility. The protocol for periodontal treatment was followed as scaling and root planing, pocket irrigation with 3% $H_2O_2$ and exposure of Nd-YAP laser using 320${\mu}m$ optical fiber with 160mJ/pluse, 30Hz. The other protocol for endodontic treatment was followed as access opening, canal preparation by hand and rotary instrument, canal filling, and exposure of Nd-YAP laser using 200${\mu}m$ optical fiber with 200mJ/pluse, 10Hz and 180mJ/pluse, 5Hz which were used respectively for disinfection and canal filling. The assessments of probing depth, mobility, and radiography were made prior to and after treatment. Result: All of these four clinical cases showed good healing of periodontium, which presented decrease of mobility and pocket depth, and increase of bone regeneration and bone density on the radiography. Conclusion: The bactericidal effect of Nd-YAP laser would provide benefits for improving clinical results that are obtained from conventional therapy.

  • PDF

Adverse Effects of Kerosene Cleaning on the Formation of DNA Adducts in Skin and Lung of Mice Dermally Exposed to Used Gasoline Engine Oil (피부에 폭로된 폐가솔린엔진오일의 표적장기 DNA adducts형성과 케로신의 세척효과에 관한 연구)

  • Lee, Jin Heon;Talaska, Glenn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.289-295
    • /
    • 1998
  • Used gasoline engine oils(UGEO) are carcinogenic in long term studies and capable of increasing the number of carcinogen-DNA adducts in short term studies when dermally applied to mice. The carcinogenic risk of UGEO has been attributed to the concentration of polycyclic aromatic hydrocarbons(PAH) which accumulate in the lubricating system during the combustion of gasoline. When dermally exposed to UGEO, the use of hand cleanser was commonly recommended for removing it. But generally workers who dermally exposed oils, use kerosene as cleaner which make skin trouble. During this study, female mice aged 4-6 weeks were utilized to evaluate the efficiency of kerosene, as solvent-based cleanser, following dermal exposure to UGEO. DNA adduct were detected at skin and lung tissues by using the $^{32}P$-postlabeling method. Washing with cleansers were done at two different interval times following dermal application of UGEO. The total DNA adducts in skin and lung tissues were statistically significantly increased in positive control groups, and of which the total adduct level in skin tissues was statistically significant higher than those in lung tissues(p=0.005). When washing kerosene, the DNA adduct level in skin tissues was statistically significantly decreased(p=0.0001). But DNA adducts in lung tissue was statistically increased(p=0.0039), and that washed at 8hr post exposure was more severly increase(p<0.05). The slope of regression between DNA adducts of lung between skin tissues was 1.0802. In conclusion, skin cleaning with kerosene facilitates passage of carcinogens to the lungs of animals dermally treated with used gasoline engine oils(UGEO).

  • PDF