• Title/Summary/Keyword: Hand Device

Search Result 779, Processing Time 0.027 seconds

Development of a Mouse for Alternative Computer Access Using Smart Device (스마트기기를 이용한 컴퓨터 대체접근 마우스 개발)

  • Jang, U.H.;Hong, W.K.;Kim, C.G.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.1
    • /
    • pp.47-55
    • /
    • 2014
  • Almost of alternate computer access devices which assist people with disabilities to utilize the computer connected to computer by some cables or installed in as a S/W program. These devices have some spatial limitations to the people with disabilities, it can't guarantee the free and diverse access to the computer. For these reasons, in this paper, an Android-based mouse program for alternative computer access was developed. A people with physical disabilities who has some limitation of hand movements can use it in anywhere and anytime using only the fine motor skill of the upper limbs. The developed device recognizes the user's point touch and transforms it into the location of mouse cursor. The location information transferred to the computer via Bluetooth communication module equipped in smart devices. Also the group scanning method which can reduce the user's fatigue degree was employed and click, double click, drag & drop functions by hand's movements were equipped. The developed device will help the people with disabilities to use computer with brief touch and convenient operation without spatial limitation.

  • PDF

Hand Gesture Interface Using Mobile Camera Devices (모바일 카메라 기기를 이용한 손 제스처 인터페이스)

  • Lee, Chan-Su;Chun, Sung-Yong;Sohn, Myoung-Gyu;Lee, Sang-Heon
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.5
    • /
    • pp.621-625
    • /
    • 2010
  • This paper presents a hand motion tracking method for hand gesture interface using a camera in mobile devices such as a smart phone and PDA. When a camera moves according to the hand gesture of the user, global optical flows are generated. Therefore, robust hand movement estimation is possible by considering dominant optical flow based on histogram analysis of the motion direction. A continuous hand gesture is segmented into unit gestures by motion state estimation using motion phase, which is determined by velocity and acceleration of the estimated hand motion. Feature vectors are extracted during movement states and hand gestures are recognized at the end state of each gesture. Support vector machine (SVM), k-nearest neighborhood classifier, and normal Bayes classifier are used for classification. SVM shows 82% recognition rate for 14 hand gestures.

A Study on Hand-signal Recognition System in 3-dimensional Space (3차원 공간상의 수신호 인식 시스템에 대한 연구)

  • 장효영;김대진;김정배;변증남
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.3
    • /
    • pp.103-114
    • /
    • 2004
  • This paper deals with a system that is capable of recognizing hand-signals in 3-dimensional space. The system uses 2 color cameras as input devices. Vision-based gesture recognition system is known to be user-friendly because of its contact-free characteristic. But as with other applications using a camera as an input device, there are difficulties under complex background and varying illumination. In order to detect hand region robustly from a input image under various conditions without any special gloves or markers, the paper uses previous position information and adaptive hand color model. The paper defines a hand-signal as a combination of two basic elements such as 'hand pose' and 'hand trajectory'. As an extensive classification method for hand pose, the paper proposes 2-stage classification method by using 'small group concept'. Also, the paper suggests a complementary feature selection method from images from two color cameras. We verified our method with a hand-signal application to our driving simulator.

Vision-based Motion Control for the Immersive Interaction with a Mobile Augmented Reality Object (모바일 증강현실 물체와 몰입형 상호작용을 위한 비전기반 동작제어)

  • Chun, Jun-Chul
    • Journal of Internet Computing and Services
    • /
    • v.12 no.3
    • /
    • pp.119-129
    • /
    • 2011
  • Vision-based Human computer interaction is an emerging field of science and industry to provide natural way to communicate with human and computer. Especially, recent increasing demands for mobile augmented reality require the development of efficient interactive technologies between the augmented virtual object and users. This paper presents a novel approach to construct marker-less mobile augmented reality object and control the object. Replacing a traditional market, the human hand interface is used for marker-less mobile augmented reality system. In order to implement the marker-less mobile augmented system in the limited resources of mobile device compared with the desktop environments, we proposed a method to extract an optimal hand region which plays a role of the marker and augment object in a realtime fashion by using the camera attached on mobile device. The optimal hand region detection can be composed of detecting hand region with YCbCr skin color model and extracting the optimal rectangle region with Rotating Calipers Algorithm. The extracted optimal rectangle region takes a role of traditional marker. The proposed method resolved the problem of missing the track of fingertips when the hand is rotated or occluded in the hand marker system. From the experiment, we can prove that the proposed framework can effectively construct and control the augmented virtual object in the mobile environments.

Interactive Fluid Simulation Method for Mobile Device (모바일 기기를 위한 실시간 유체 시뮬레이션 엔진)

  • Kim, Do-Yub;Song, Oh-Young;Ko, Hyeong-Seok
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.463-468
    • /
    • 2009
  • This paper proposes a method for extending simulating fluid on mobile device, which was only possible on desktop PC. Fluid simulation is done by solving Navier-Stokes equation numerically, and previous research were mainly focused on numerical stability [1], and realism [2]. However, such methods assume rich computational resources, which is not available on mobile devices. On the other hand, rigid-body solver is the mostly used physically-based technique [3], and only simple height field-based method is released for fluid simulation [4]. To overcome these problems, we proposes a modified incompressible fluid dynamics solver for the mobile device, and also we propose a technique for visualizing fluids on the mobile device.

  • PDF

Apparatus for determining the angular position, speed and/or direction of rotary objects

  • Lim, J.T.;Choi, D.H.;Lee, H.J.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.596-600
    • /
    • 1986
  • This paper describes a capacitively reading apparatus for determining the angular orientation, speed and/or direction of rotary objects such as shaft, dial hand, counter wheel and the like. The apparatus consists of sensing device and circuit accompanying with said sensing device. The sensing device is provided by arranging many stationary electrodes lying substantially on a surface of a stationary plane member and by arranging rotary electrode lying substantially on a surface of rotary objects to be monitored, in which said rotary electrode is in confronting relationship to some stationary electrodes so as to construct unique capacitors according to the angular position of rotary objects. The angular position of said rotary electrode is determined by sets of stationary electrodes which are in confronting relationship to rotary electrode. A carrier signal is generated by scanning device while scanning said stationarelectrodes, whose periods are in corresponding relationship to said stationary electrodes, respectively. The periods of carrier corresponding to the angular position of said rotary electrode is modulated by a modulation signal generated by detecting device according to said rotary electrode. This apparatus is applied to automatically monitor any kind of storage tank, as well as to automatically read the conventional utility meters such as Watthour meters, Gas meters, Water meters, etc..

  • PDF

Oxygen Adsorption/Desorption Reaction of Pd-$SnO_x$-$Si_3N_4$-$SiO_2$-Si-Al Capacitor (D.C. 전압 인가에 의한 Pd-$SnO_x$-$Si_3N_4$-$SiO_2$-Si-Al 캐패시터의 산소흡착/탈착 반응)

  • Lee, Jae-Hong;Lee, Joo-Hun;Kim, Chang-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1222-1225
    • /
    • 1997
  • A gaseous oxygen detector has been developed in a configuration of Pd-$SnO_x$-$Si_3N_4$-$SiO_2$-Si-Al with highly resistive $SnO_x$ layer as the oxygen adsorptive element. In this paper, we present the characteristics of the device in response to oxygen adsoption/desorption under applied d.c. bias. Experimental results showed that the oxygen adsorptive response by the device was reduced significantly under a positive gate bias, for all experimental regions of $O_2$ partial pressure. On the other hand, the application of a negative gate bias increased the device's adsorptive response of oxgyen. A device model concerning this electroadsorption/desorption behavior of the device is provided.

  • PDF

Synthesis of Flake Type Micro Hollow Silica Using Mg(OH)2 Inorganic Template

  • Lee, Ji-Seon;Noh, Kyeong-Jae;Moon, Seong-Cheol;Lee, Young-Chul;Lee, Seong-Eui
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.3
    • /
    • pp.222-227
    • /
    • 2017
  • Flake-type micro hollow silica was synthesized by precipitation method using an $Mg(OH)_2$ inorganic template and sodium silicate and ammonium sulfate as the silica precursors. We investigated the effects of the silica precursor concentration on the shape, shell thickness, and surface of the hollow silica. When the concentration of the silica precursor was 0.5 M, the hollow silica had a smooth and translucent thin shell, but the shell was broken. On the other hand, the shell thickness of the hollow silica changed in the range of 12 nm to 18 nm with the increase of the precursor concentration from 0.7 M to 1.1 M. Simultaneously, unintended spherical silica satellites were created on the shell surface. The number of satellites and the size rose according to the increased concentration of silica precursor. The reason for the formation of spherical silica satellites is that the $NH_4OH$ nucleus generated in the synthesis of hollow silica acted as another silica reaction site.

A Survey of Interaction Table Top Display for Cooperation (협업을 위한 상호작용 테이블 탑 디스플레이의 연구동향)

  • Park, jae-wan;Song, dae-hyun;Lee, chil-woo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.66-68
    • /
    • 2008
  • This paper provides a user interface for mutual collaboration table top display technology. The biggest difference is that the existing interface with existing research through a single device to multiple users simultaneously enabled oriented way of face to face. On the other hand, in collaboration important deadline table top display device to device-oriented approach in which the order of one of the devices require users. Collaborative research is actively underway, but to do so focused still many challenges in this situation. This paper provides for collaboration on global trends on a table top display interface for more mutual collaboration with the user interface for about checking out on a table top display, currently being developed by a collaboration among users against a table top display technology.

  • PDF

Development of Mobile X-ray equipment for medicine (의료용 모바일 X선 장치의 개발)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.762-763
    • /
    • 2010
  • The X-ray device used for medical treatment is classified into fixed type that is used by installing at the location with the stable power supply and mobile type that can be taken by moving the X-ray device to the location where a patient is. Mobile X-ray device which is typically used in the mobile type of X-ray can be used very usefully beyond the space restriction. However, due to its difficulty to generate high-voltage, it is mainly applied to take hand and foot shootings which only need low output power. In this study, by designing and producing the large volume of mobile X-ray device which doesn't have the limitations on diagnostic areas of the body, the operating characteristics of device according to the loading change was identified.

  • PDF