• Title/Summary/Keyword: Hand Detecting

Search Result 205, Processing Time 0.034 seconds

Low-cost Impedance Technique for Structural Health Monitoring (임피던스 기반 저비용 구조물 건전성 모니터링 기법)

  • Lee, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.265-271
    • /
    • 2018
  • This paper presents a method for detecting damage to a structure at low cost using its impedance. The impedance technique is a typical method to detect local damage for structural health monitoring. This is a common technique for estimating damage by monitoring the electro-mechanical admittance signal of the structure. To apply this technique, an expensive impedance analyzer is generally used. On the other hand, it is necessary to develop a low-cost variant to effectively disseminate the technique. In this study, a method based on the transfer impedance using a function generator and digital multimeter, which are generally used in the laboratory instead of an impedance analyzer, was developed. That is, this technique estimates the damage by comparing the damage index using the amplitude ratio of the output voltage measured in the healthy and damaged state. A transfer impedance test was carried out on a steel specimen. By comparing the damage index, the presence of damage could be assessed reasonably. This study is a basic investigation of an impedance-based low-cost damage detection method that can be used effectively for structural health monitoring if supplemented with future research to estimate the damage location and severity.

A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment (정맥 검출 장비 구현 및 영상처리 알고리즘 개발에 대한 연구)

  • Jin-Hyoung, Jeong;Jae-Hyun, Jo;Jee-Hun, Jang;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.463-470
    • /
    • 2022
  • Intravenous injection is widely used for patient treatment, including injection drugs, fluids, parenteral nutrition, and blood products, and is the most frequently performed invasive treatment for inpatients, including blood collection, peripheral catheter insertion, and other IV therapy, and more than 1 billion cases per year. Intravenous injection is one of the difficult procedures performed only by experienced nurses who have been trained in intravenous injection, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Nurses who frequently perform intravenous injections may also make mistakes because it is not easy to detect veins due to factors such as obesity, skin color, and age. Accordingly, studies on auxiliary equipment capable of visualizing the venous structure of the back of the hand or arm have been published to reduce mistakes during intravenous injection. This paper is about the development of venous detection equipment that visualizes venous structure during intravenous injection, and the optimal combination was selected by comparing the brightness of acquired images according to the combination of near-infrared (NIR) LED and Filter with different wavelength bands. In addition, an image processing algorithm was derived to threshehold and making blood vessel part to green through grayscale conversion, histogram equilzation, and sharpening filters for clarity of vein images obtained through the implemented venous detection experimental module.

A Study on the Comparison of Detected Vein Images by NIR LED Quantity of Vein Detector (정맥검출기의 NIR LED 수량에 따른 검출된 정맥 이미지 비교에 관한 연구)

  • Jae-Hyun, Jo;Jin-Hyoung, Jeong;Seung-Hun, Kim;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.485-491
    • /
    • 2022
  • Intravenous injection is the most frequent invasive treatment for inpatients and is widely used for parenteral nutrition administration and blood products, and more than 1 billion procedures are used for peripheral catheter insertion, blood collection, and other IV therapy per year. Intravenous injection is one of the difficult procedures to be performed only by trained nurses with intravenous injection training, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Accordingly, studies on auxiliary equipment capable of visualizing the vein structure of the back of the hand or arm are being published to reduce errors during intravenous injection. This study is a study on the performance difference according to the number of LEDs irradiating the 850nm wavelength band on a vein detector that visualizes the vein during intravenous injection. Four LED PCBs were produced by attaching NIR filters to CCD and CMOS camera lenses irradiated on the skin to acquire images, sharpen the acquired images using image processing algorithms, and project the sharpened images onto the skin. After that, each PCB was attached to the front end of the vein detector to detect the vein image and create a performance comparison questionnaire based on the vein image obtained for performance evaluation. The survey was conducted on 20 nurses working at K Hospital.

Strawberry Pests and Diseases Detection Technique Optimized for Symptoms Using Deep Learning Algorithm (딥러닝을 이용한 병징에 최적화된 딸기 병충해 검출 기법)

  • Choi, Young-Woo;Kim, Na-eun;Paudel, Bhola;Kim, Hyeon-tae
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.255-260
    • /
    • 2022
  • This study aimed to develop a service model that uses a deep learning algorithm for detecting diseases and pests in strawberries through image data. In addition, the pest detection performance of deep learning models was further improved by proposing segmented image data sets specialized in disease and pest symptoms. The CNN-based YOLO deep learning model was selected to enhance the existing R-CNN-based model's slow learning speed and inference speed. A general image data set and a proposed segmented image dataset was prepared to train the pest and disease detection model. When the deep learning model was trained with the general training data set, the pest detection rate was 81.35%, and the pest detection reliability was 73.35%. On the other hand, when the deep learning model was trained with the segmented image dataset, the pest detection rate increased to 91.93%, and detection reliability was increased to 83.41%. This study concludes with the possibility of improving the performance of the deep learning model by using a segmented image dataset instead of a general image dataset.

Study on Establishment of a Monitoring System for Long-term Behavior of Caisson Quay Wall (케이슨 안벽의 장기 거동 모니터링 시스템 구축 연구 )

  • Tae-Min Lee;Sung Tae Kim;Young-Taek Kim;Jiyoung Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.40-48
    • /
    • 2023
  • In this paper, a sensor-based monitoring system was established to analyze the long-term behavioral characteristics of the caisson quay wall, a representative structural type in port facilities. Data was collected over a period of approximately 10 months. Based on existing literature, anomalous behaviors of port facilities were classified, and a measurement system was selected to detect them. Monitoring systems were installed on-site to periodically collect data. The collected data was transmitted and stored on a server through LTE network. Considering the site conditions, inclinometers for measuring slope and crack meters for measuring spacing and settlement were installed. They were attached to two caissons for comparison between different caissons. The correlation among measured data, temperature, and tidal level was examined. The temperature dominated the spacing and settlement data. When the temperature changed by approximately 50 degrees, the spacing changed by 10 mm, the settlement by 2 mm, and the slope by 0.1 degrees. On the other hand, there was no clear relationship with tidal level, indicating a need for more in-depth analysis in the future. Based on the characteristics of these collected database, it will be possible to develop algorithms for detecting abnormal states in gravity-type quay walls. The acquisition and analysis of long-term data enable to evaluate the safety and usability of structures in the event of disasters and emergencies.

The Comparison of Susceptibility Changes in 1.5T and3.0T MRIs due to TE Change in Functional MRI (뇌 기능영상에서의 TE값의 변화에 따른 1.5T와 3.0T MRI의 자화율 변화 비교)

  • Kim, Tae;Choe, Bo-Young;Kim, Euy-Neyng;Suh, Tae-Suk;Lee, Heung-Kyu;Shinn, Kyung-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.154-158
    • /
    • 1999
  • Purpose : The purpose of this study was to find the optimum TE value for enhancing $T_2^{*}$ weighting effect and minimizing the SNR degradation and to compare the BOLD effects according to the changes of TE in 1.5T and 3.0T MRI systems. Materials and Methods : Healthy normal volunteers (eight males and two females with 24-38 years old) participated in this study. Each volunteer was asked to perform a simple finger-tapping task (sequential opposition of thumb to each of the other four fingers) with right hand with a mean frequency of about 2Hz. The stimulus was initially off for 3 images and was then alternatively switched on and off for 2 cycles of 6 images. Images were acquired on the 1.5T and 3.0T MRI with the FLASH (fast low angle shot) pulse sequence (TR : 100ms, FA : $20^{\circ}$, FOV : 230mm) that was used with 26, 36, 46, 56, 66, 76ms of TE times in 1.5T and 16, 26, 36, 46, 56, 66ms of TE in 3.0T MRI system. After the completion of scan, MR images were transferred into a PC and processed with a home-made analysis program based on the correlation coefficient method with the threshold value of 0.45. To search for the optimum TE value in fMRI, the difference between the activation and the rest by the susceptibility change for each TE was used in 1.5T and 3.0T respectively. In addition, the functional $T_2^{*}$ map was calculated to quantify susceptibility change. Results : The calculated optimum TE for fMRI was $61.89{\pm}2.68$ at 1.5T and $47.64{\pm}13.34$ at 3.0T. The maximum percentage of signal intensity change due to the susceptibility effect inactivation region was 3.36% at TE 66ms in 1.5T 10.05% at TE 46ms in 3.0T, respectively. The signal intensity change of 3.0T was about 3 times bigger than of 1.5T. The calculated optimum TE value was consistent with TE values which were obtained from the maximum signal change for each TE. Conclusion : In this study, the 3.0T MRI was clearly more sensitive, about three times bigger than the 1.5T in detecting the susceptibility due to the deoxyhemoglobin level change in the functional MR imaging. So the 3.0T fMRI I ore useful than 1.5T.

  • PDF

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

The Effect of a Chest CT Scan on the Treatment and Diagnosis of Major Blunt Chest Trauma (흉부 둔상환자에서 흉부전산화단층촬영이 진단과 치료에 미치는 영향)

  • Park, Il-Hwan;Oh, Joong-Hwan;Lee, Chong-Kook
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.226-232
    • /
    • 2009
  • Background: Blunt chest trauma accounts for 90% of all chest traumas in Europe and the United States and this causes 20% of all trauma-related deaths. The major cause of morbidity and mortality after blunt chest trauma is undetected injuries. For this reason, chest computerized tomography has gained popularity for the evaluation of trauma, but it is expensive and it exposes patients to radiation. This study identified the clinical features associated with the diagnosic information obtained on a CT chest scan, as compared with a standard chest X-ray, for patients who sustained blunt trauma to the chest. This study also evaluated the role of a routine computed tomographic (CT) scan for these patients. The patients who had chest computed tomography done after the initial chest x-ray were analyzed separately for the presence of occult injuries. Material and Method: We studied 100 consecutive patients from November 2006 to July 2007: 74 patients after motor vehicle crashes and 26 patients after a fall from a height >2m. Simultaneous with the initial clinical evaluation, an anteroposterior chest radiograph and a helical chest CT scan were obtained for all the patients. The data extracted from the medical record included the vital signs, the interventions and the type and severity of injury (RTS). Result: Among the 100 cases, 79 patients showed at least more than one pathologic sign on their chest radiograph, and 21 patients had a normal chest radiograph. For 17 of the patients who had a normal chest X ray, the CT scan showed multiple injuries, which were pneumothorax, hemothorax, lung contusion, sternal fracture etc. This represents that a CT scan is statistically superior to a chest radiograph to diagnose the pathologic signs. But on the other hand, as for treatment, only 31 patients were diagnosed by CT scan and they were treated with chest tube insertion ect. 42 patients needed ony conservative management without invasive thoracosurgical treatment such as chest tube insertion or open thoracotomy. 27 patients were treated based on the diagnosis made by the chest radiograph and physical examination. Conclusion: Chest computerized tomography was significantly more effective than routine chest X-ray for detecting lung contusion, pneumothorax and mediastinal hematoma, as well as fractured ribs, scapula and, sternum. Although the occult findings increased, the number of patients who needed treatment was small. Therefore, we suggest making selective use of a CT scan to avoid its overuse in ERs.

Characteristics of Growth, Yield, and Physiological Responses of Small-Sized Watermelons to Different Soil Moisture Contents Affected by Irrigation Starting Point in a Plastic Greenhouse (소형 수박 시설 재배 시 관수개시점에 따른 토양수분 함량별 생육, 수량 및 생리적 반응 특성 구명)

  • Huh, Yoon-Sun;Kim, Eun-Jeong;Noh, Sol-Ji;Jeon, Yu-Min;Park, Sung-Won;Yun, Geon-Sig;Kim, Tae-Il;Kim, Young-Ho
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.388-398
    • /
    • 2020
  • Watermelon yield mainly depends on soil water content controlled by irrigation in a plastic greenhouse. In this study, we investigated the effect of different soil moisture contents affected by irrigation starting point on growth, yield, and physiological responses of small-sized watermelons. Irrigation was initiated at 5 different levels of soil water content as a starting point with soil moisture detecting sensor after 14 days of transplanting, and stopped at 7 ~ 10 days before harvest. These treatments were compared with the conventional periodic irrigation as control. When soil had the lowest moisture content (-50 kPa), the overall shoot growth was retarded, but the root length and root dry weight increased. The photosynthetic parameters (photosynthetic rate, stomatal conductance, and transpiration rate) of watermelon leaves decreased significantly in the lowest soil moisture content (-50 kPa). On the other hand, the photosynthetic rates of watermelon leaves grown with irrigation starting point between -20 and -40 kPa were observed to be higher than those of other treatments. Fruit set rate and marketable fruit yield increased significantly at -30 kPa and -40 kPa. Proline, abscisic acid (ABA), total phenol and citrulline, which are known to contribute to stress tolerance under drought condition, increased as soil water content decreased, particularly, the largest increases were recorded at -50 kPa. From these results, it was found that an appropriate water supply adjusted with an irrigation starting point between -30 and -40 kPa could help to keep favorable soil water content during the cultivation of small-sized watermelons, promoting the marketable fruit production as well as inducing the vigorous plant growth and reproductive development.

Application of the Enzyme-linked Immunosorbent Assay to the Serodiagnosis of Typhoid Fever (장티푸스의 혈청학적 진단에 효소결합면역측정법(Enzyme-linked Immunosorbent Assay)의 적용 실험)

  • Kye, Ki-Shik;Kim, Yae-Hum;Choi, Kang-Won;Hwang, Eung-Soo;Kook, Yoon-Ho;Lee, Seung-Hoon;Cha, Chang-Yong
    • The Journal of the Korean Society for Microbiology
    • /
    • v.18 no.1
    • /
    • pp.73-85
    • /
    • 1983
  • The advantages of the enzyme-linked immunosorbent assay(ELISA) are its sensitivity and its simplicity in detecting IgM and IgG antibodies. For applying the ELISA to the diagnosis of typhoid fever, first of all, experiments were performed to determine which concentration of killed whole cell antigens and lipopolysaccharide(LPS) antigens of S. typhi(0.901 w) were optimally coated to the wells of the polystyrene and polyvinylchloride microplate, using the hyperimmune sera from rabbits against S. typhi. By using both kinds of antigens of S. typhi adsorbed to the ELISA microplate, the changing patterns of IgG and IgM antibodies in the sera from rabbits responding to the killed whole cell antigens of S. typhi(0901 w) during the prolonged immunization were serially traced by the ELISA. At the same time, the level of antibodies against S. typhi in sera fron patients with typhoid fever and from normal healthy persons were measured by the ELISA employing the killed whole cell antigens and LPS antigens as the coating antigens. The results obtained were summerized as follow: 1. The optimal concentration of the killed whole cell antigens, which were more easily adsorbed to the polystyrene plate than the polyvinylchloride plate, was $10^8cells/ml$ of carbonate buffer(pH. 9.6) on the wells of the polystyrene plate when treated at $37^{\circ}C$ for 4 hours. On the other hand, the optimal concentration of lipopolysaccharide antigens, which were adsorbed only to the polyvinylchloride plate, was $100{\mu}g/ml$ of carbonate buffer(pH. 9.6) on the wells of the polyvinylchloride plate when treated at $37^{\circ}C$ for 4 hours. 2. IgM antibody response were dominating in rabbits responding to the killed whole cell antigens of S. typhi(0.901 w), and were more specific to the LPS antigens than to the killed whole cell antigens in the ELISA. Good correlations were made between the IgM titers by the ELISA and the aggglutinating titers of sera from the immunized rabbits. 3. Both IgG and IgM agglutination titers by the ELISA in sera from most of patients with typhoid fever were above 1:320 but those in sera from most of normal, healthy persons were below 1:80. 4. There were close correlations between the antibody titers by the ELISA and the agglutinating titers to the killed whole cell antigens in the tested human sera, IgM titers being more correlated with the agglutinating titers than IgG titers. But a little correlations were made between the antibody titers by the ELISA and the agglutinating titers to the LPS antigens. 5. IgM titers in the tested human sera were similar to IgG titers detected by the ELISA employing the killd whole cells antigens and the LPS antigens. 6. Good correlations were made between the antibody titers demonstrated by the ELISA performed on the killed whole cell antigens and the LPS antigens as the different, coating antigens on the ELISA microplates.

  • PDF