• Title/Summary/Keyword: Half-normal distribution

Search Result 66, Processing Time 0.033 seconds

Inward Leakage Test for Particulate Filtering Respirators in Korea (방진마스크의 안면부 누설률에 관한 연구)

  • Han Don-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.432-439
    • /
    • 2004
  • Korean certification regulation for particulate filtering respirators requires inward leakage (IL) test as European Standards (EN) and the standard levels of regulation are the same as those of EN. This study was conducted to evaluate particulate filtering respirators being commercially used in the market by using IL and assess the characteristics of IL. The study began with discussing the concept of IL, comparison of IL with fit test, and IL measurement method. Three brands of half masks and 10 brands of filtering facepieces (two top class, four 1st class and four 2nd class), total 13 brands respirators, and 10 test panels (subjects) who were classified in 9 facial grids in accordance with face length and lip length, were selected for IL test. IL tests were conducted in the laboratory of 3M Innovation Center which was established by EN standard. As expected ILs of half masks were lower than those of filtering facepiece mask. ILs of half masks and some filtering facepieces were significantly different in manufacturers. ILs of 1st class filtering facepieces were found to be much more than those of 2nd class and thus the result would cause wearers to get confused to select a mask. Four of six brands being no compliance with standards were thought that they should be tested again for certification because of a lot of differences from standards. There were no significant differences among ILs of five exercises. In 6 out of 13 brands lognormal distribution of ILs may be a better fit distribution and in 7 brands both lognormal and normal distributions were rejected. The result indicates that geometric mean may be better than arithmetic mean to establish standard.

Analysis and Probability of Overestimation by an Imperfect Inspector with Errors of Triangular Distributions (삼각 과오 분포를 가진 불완전한 검사원의 과대 추정 확률과 분석)

  • Yang, Moon Hee;Cho, Jae Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.2
    • /
    • pp.117-132
    • /
    • 2018
  • There always exist nonzero inspection errors whether inspectors are humans or automatic inspection machines. Inspection errors can be categorized by two types, type I error and type II error, and they can be regarded as either a constant or a random variable. Under the assumption that two types of random inspection errors are distributed with the "uniform" distribution on a half-open interval starting from zero, it was proved that inspectors overestimate any given fraction defective with the probability more than 50%, if and only if the given fraction defective is smaller than a critical value, which depends upon only the ratio of a type II error over a type I error. In addition, it was also proved that the probability of overestimation approaches one hundred percent as a given fraction defective approaches zero. If these critical phenomena hold true for any error distribution, then it might have great economic impact on commercial inspection plans due to the unfair overestimation and the recent trend of decreasing fraction defectives in industry. In this paper, we deal with the same overestimation problem, but assume a "symmetrical triangular" distribution expecting better results since our triangular distribution is closer to a normal distribution than the uniform distribution. It turns out that the overestimation phenomenon still holds true even for the triangular error distribution.

Structural Evolution of the Northern Okinawa Trough (북부 오키나와트러프의 구조 발달)

  • Sunwoo Don
    • Economic and Environmental Geology
    • /
    • v.37 no.5
    • /
    • pp.543-554
    • /
    • 2004
  • Analysis of multi-channel seismic reflection and well data serves to detail the structural evolution of the northern Okinawa Trough, southern offshore Korea. The overall structural style of the area is characterized by a series of half grabens and tilted fault blocks bounded by basement-involved listric normal faults. Most half grabens and tilted fault blocks developed in the direction of NNE-SSW, parallel to the axis of the Okinawa Trough. Orientation and distribution of the listric faults also suggest the development of transfer faults in NW-SE direction. The rifting phase of the northern Okinawa Trough have been established on the basis of structural and stratigraphic analyses of depositional sequences and their seismic expressions. Major phase of rifting probably started in the Late Miocene and the most active rifting occurred during the Early Pliocene. The rifting produced a series of half grabens and tilted fault blocks bounded by listric normal faults. It appears that the rifting activity has become weaker since the Late Pliocene, but the Pleistocene sediments faulted by listric faults bounding tilted fault blocks suggest that the rifting activity is probably still in progress.

The Effects of Discrepancy in Reconstruction Algorithm between Patient Data and Normal Database in AutoQuant Evaluation: Focusing on Half-Time Scan Algorithm in Myocardial SPECT (심근 관류 스펙트에서 Half-Time Scan과 새로운 재구성법이 적용된 정상군 데이터를 기반으로 한 정량적 분석 결과의 차이 비교)

  • Lee, Hyung-Jin;Do, Yong-Ho;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.122-126
    • /
    • 2014
  • Purpose: The new reconstruction algorithms (NRA) provided by vendor aim to shorten the acquisition scan time. Whereas depending on the installed version AutoQuant program used for myocardial SPECT quantitative analysis did not contain the normal data that NRA is applied. Thus, the purpose of this paper is to compare the results according to AutoQuant versions in myocardial SPECT applied NRA and half-time scan (HT). Materials and Methods: Rest Tl and stress MIBI data of total 80 (40 men, 40 women) patients were gathered. Data were applied HT acquisition and ASTONISH (Philips) software which is NRA. Modified autoquant of SNUH and old version of AutoQuant (full-time scan) provided by company were compared. Comparison groups were classified as coronary artery disease (CAD), 24 hrs delay and almost normal patients who have a simple pain patient. Perfusion distribution aspect, summed stress score (SSS), summed rest score (SRS), extent and total perfusion deficit (TPD) of each 25 patient who have above diseases were compared and evaluated. Results: The case of CAD, when using re-edited AutoQuant (HT) SSS and SRS showed about 30% reduction (P<0.0001), Extent showed about 38% reduction and TPD showed about 30% reduction in the tendency (P<0.0001). In the score of the perfusion, especially on the part of infero-medium, infero-apical, lateral-medium and lateral-apical regions were the biggest change. The case of the 24 hrs delay patient SRS (P=0.042), Extent (P=0.018) and TPD (P=0.0024) showed about 13-18% reduction. And the case of simple pain patient, comparison of 4 results showed about 5-7% reduction. Conclusion: This study was started based on expectation that results could be affected by normal patient data. Normal patient data is possible to change by race and gender. It was proved that combination of new reconstruction algorithm for reducing scan time and analysis program according to scan protocol with NRA could also be affected to results. Clinical usefulness of gated myocardial SPECT is possibly increased if each hospital properly collects normal patient data for their scan acquisition protocol.

  • PDF

Drug interaction of Cimetidine and Rifampicin in normal Human subjects (시메티딘과 리팜피신의 상호작용)

  • Moon, Hong-Seob;Choi, In;Cho, Joon-Shik;Shin, Yong-Jun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.3 no.1
    • /
    • pp.1-13
    • /
    • 1993
  • The intraction between cimetidine and rifampicin was studied pharmacokinetically in normal human subjects. The serum level and the area under the serum concentration curve(AUC) of rifampicin administrated orally were elevated significantly by cimetidine. Volume of distribution, total clearance and elimination rate constant of rifampicin were reduced significanyly by cimetidine. Biological half-life of rifampicin was prolonged significantly by cimetidine. The mechanism of this results is probably related to the inhibition of rifampicin metabolism(deacetyl form) or reduction of blood flow in the liver. It is desirable that dosage regimen of rifampicin shoud be adjusted when combined with cimetidine in clinical pharmacy practice.

  • PDF

A Study on the Construction and Analysis of Fractional Designs by Using Arrays for Factorial Experiments (배열을 이용한 효과적인 일부실시법의 설계 및 분석방법에 관한 연구)

  • Kim, Sang-Ik
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.1
    • /
    • pp.15-24
    • /
    • 2012
  • For the construction of fractional factorial designs, the various arrays can be widely used. In this paper we review the statistical properties of fractional designs constructed by two arrays such as orthogonal array and partially balanced array, and develop a quick and easy method for analyzing unreplicated saturated designs. The proposed method can be characterized that we control the error rate by experiment-wise way and exploit the multivariate Student $t$-distribution. Especially the proposed method can be used efficiently together with some exploratory analysis methods, such as half normal probability plot method.

Shift of Vietnamese Consumer E-purchasing Behavior During and After Covid-19 Pandemic

  • Pham Thi Cam ANH;Nguyen Mai PHUONG;Nguyen Huong GIANG;Pham Ngoc Mai LINH;Nguyen Huong GIANG
    • Journal of Distribution Science
    • /
    • v.22 no.1
    • /
    • pp.47-59
    • /
    • 2024
  • Purposes: The study aimed at examining the impact of the COVID-19 pandemic on the shift of online consumer purchasing behavior and whether the new behaviors would be maintained after the epidemic season. The study also aims to investigate how online customers change based on perceived risks. Research design and Methodology: The study investigated purchasing behavior of the same 377 online Vietnamese consumers during two periods: (1) during the period of social distancing and (2) one and half year after that, allowing data to be collected in real time, so that consumers do not have to recall their behavior. Results: Purchasing behavior appeared to be more influenced by gender, age and household size. Aged consumers are more concerned about risks than those in the younger group, who only worry about the risks during the pandemic. Consumers in households with two or more people are more concerned about the risks than those living alone. Female appeared to be more influential in both during and after pandemic than male. Conclusions: The findings contribute to clarify shift of online consumer purchasing behavior, which helps business to develop effective marketing strategies and enhance their presence in the e-commerce sector.

A Study on the Construction of MVCT Dose Calculation Model by Using Dosimetry Check™ (Dosimetry Check™를 이용한 MVCT 선량계산 모델 구축에 관한 연구)

  • Um, Ki-Cheon;Kim, Chang-Hwan;Jeon, Soo-Dong;Back, Geum-Mun
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.431-441
    • /
    • 2020
  • The purpose of this study was to construct a model of MVCT(Megavoltage Computed Tomography) dose calculation by using Dosimetry Check™, a program that radiation treatment dose verification, and establish a protocol that can be accumulated to the radiation treatment dose distribution. We acquired sinogram of MVCT after air scan in Fine, Normal, Coarse mode. Dosimetry Check™(DC) program can analyze only DICOM(Digital Imaging Communications in Medicine) format, however acquired sinogram is dat format. Thus, we made MVCT RC-DICOM format by using acquired sinogram. In addition, we made MVCT RP-DICOM by using principle of generating MLC(Multi-leaf Collimator) control points at half location of pitch in treatment RP-DICOM. The MVCT imaging dose in fine mode was measured by using ionization chamber, and normalized to the MVCT dose calculation model, the MVCT imaging dose of Normal, Coarse mode was calculated by using DC program. As a results, 2.08 cGy was measured by using ionization chamber in Fine mode and normalized based on the measured dose in DC program. After normalization, the result of MVCT dose calculation in Normal, Coarse mode, each mode was calculated 0.957, 0.621 cGy. Finally, the dose resulting from the process for acquisition of MVCT can be accumulated to the treatment dose distribution for dose evaluation. It is believed that this could be contribute clinically to a more realistic dose evaluation. From now on, it is considered that it will be able to provide more accurate and realistic dose information in radiation therapy planning evaluation by using Tomotherapy.

Change in radiation characteristics outside the SNF storage container as an indicator of fuel rod cladding destruction

  • Rudychev, V.G.;Azarenkov, N.A.;Girka, I.O.;Rudychev, Y.V.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3704-3710
    • /
    • 2021
  • The characteristics of the external radiation on the surface of the casks for spent nuclear fuel (SNF) storage by dry method are investigated for the case when the spatial distribution of SNF in the basket changes due to the destruction of the fuel rod claddings. The surface areas are determined, where the changes in fluxes of neutrons, produced by 244Cm actinide, and γ-quanta, produced by long-lived isotopes, are maximum in the result of the decrease in the height of the SNF area. Concrete (VSC-24) and metal (SC-21) casks are considered as examples. The procedure of periodic measurement of the dose rate of neutrons or γ-quanta at the specified points of the cask surface is proposed for identifying the fuel rod cladding destruction. Under normal operation, the decrease in the dose rate produced by neutrons as the function of SNF storage duration is determined by the half-life of 244Cm, and for γ-quanta - by the half-lives of long-lived SNF isotopes. Consequently, a stepwise change in the dose rate of neutrons or γ-quanta, detected by the measurements, as compared to the previous one, would indicate the destruction of the fuel rod claddings.

Regional Analysis of Particulate Matter Concentration Risk in South Korea (국내 지역별 미세먼지 농도 리스크 분석)

  • Oh, Jang Wook;Lim, Tea Jin
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.157-167
    • /
    • 2017
  • Millions of People die every year from diseases caused by exposure to outdoor air pollution. Especially, one of the most severe types of air pollution is fine particulate matter (PM10, PM2.5). South Korea also has been suffered from severe PM. This paper analyzes regional risks induced by PM10 and PM2.5 that have affected domestic area of Korea during 2014~2016.3Q. We investigated daily maxima of PM10 and PM2.5 data observed on 284 stations in South Korea, and found extremely high outlier. We employed extreme value distributions to fit the PM10 and PM2.5 data, but a single distribution did not fit the data well. For theses reasons, we implemented extreme mixture models such as the generalized Pareto distribution(GPD) with the normal, the gamma, the Weibull and the log-normal, respectively. Next, we divided the whole area into 16 regions and analyzed characteristics of PM risks by developing the FN-curves. Finally, we estimated 1-month, 1-quater, half year, 1-year and 3-years period return levels, respectively. The severity rankings of PM10 and PM2.5 concentration turned out to be different from region to region. The capital area revealed the worst PM risk in all seasons. The reason for high PM risk even in the yellow dust free season (Jun. ~ Sep.) can be inferred from the concentration of factories in this area. Gwangju showed the highest return level of PM2.5, even if the return level of PM10 was relatively low. This phenomenon implies that we should investigate chemical mechanisms for making PM2.5 in the vicinity of Gwangju area. On the other hand, Gyeongbuk and Ulsan exposed relatively high PM10 risk and low PM2.5 risk. This indicates that the management policy of PM risk in the west side should be different from that in the east side. The results of this research may provide insights for managing regional risks induced by PM10 and PM2.5 in South Korea.