• 제목/요약/키워드: Half-Width

검색결과 919건 처리시간 0.031초

분말 합성법(Sol-Gel & Solid-State reaction)에 따른 Lithium Lanthanum Titanate 분말의 입자 및 결정 크기 비교 분석에 관한 연구 (A Study on Particle and Crystal Size Analysis of Lithium Lanthanum Titanate Powder Depending on Synthesis Methods (Sol-Gel & Solid-State reaction))

  • 윤정재;이승환;백소현;권용범;송요셉;김범성;이빈;곽노균;정다운
    • 한국분말재료학회지
    • /
    • 제30권4호
    • /
    • pp.324-331
    • /
    • 2023
  • Lithium (Li) is a key resource driving the rapid growth of the electric vehicle industry globally, with demand and prices continually on the rise. To address the limited reserves of major lithium sources such as rock and brine, research is underway on seawater Li extraction using electrodialysis and Li-ion selective membranes. Lithium lanthanum titanate (LLTO), an oxide solid electrolyte for all-solid-state batteries, is a promising Li-ion selective membrane. An important factor in enhancing its performance is employing the powder synthesis process. In this study, the LLTO powder is prepared using two synthesis methods: sol-gel reaction (SGR) and solid-state reaction (SSR). Additionally, the powder size and uniformity are compared, which are indices related to membrane performance. X-ray diffraction and scanning electron microscopy are employed for determining characterization, with crystallite size analysis through the full width at half maximum parameter for the powders prepared using the two synthetic methods. The findings reveal that the powder SGR-synthesized powder exhibits smaller and more uniform characteristics (0.68 times smaller crystal size) than its SSR counterpart. This discovery lays the groundwork for optimizing the powder manufacturing process of LLTO membranes, making them more suitable for various applications, including manufacturing high-performance membranes or mass production of membranes.

열화학기상증착법을 이용한 CsPbBr3 박막 성장 및 특성 연구 (A Growth and Characterization of CsPbBr3 Thin Film Grown by Thermal Chemical Vapor Deposition)

  • 김가은;김민진;류혜수;이상현
    • 마이크로전자및패키징학회지
    • /
    • 제30권2호
    • /
    • pp.71-75
    • /
    • 2023
  • 본 연구에서는 열화학기상증착법을 이용한 세슘계 무기 페로브스카이트의 성장기판에 따른 결정 구조의 변화 및 광학적 특성을 비교 분석하였다. 무기 페로브스카이트 결정은 CsBr과 PbBr2를 전구체로 사용하여 SiO2/Si와 c-Al2O3 기판 위에 동일한 조건으로 CsPbBr3를 성장하였다. 비정질 구조를 가진 SiO2 표면에서는 Cs4PbBr6-CsPbBr3 혼합상의 결정 입자가 성장하였으며, 단결정 구조인 c-Al2O3 기판에서는 CsPbBr3 (100) 결정 면방향이 우세한 단일상의 박막이 형성되었다. 광학적 분석 결과 CsPbBr3는 약 91 meV의 반치폭을 갖고 약 534 nm 중심의 발광특성을 보였으며, Cs4PbBr6-CsPbBr3 혼합구조에서는 청색 변이에 의해 523 nm의 발광 및 6.88 ns의 빠른 광 소결시간을 확인하였다. 열화학기상증착법을 이용한 페로브스카이트의 결정구조의 제어 및 광특성의 변화는 디스플레이, 태양 전지, 광센서 등 다양한 광전 소자에 적용할 수 있을 것으로 기대된다.

Physio-mechanical and X-ray CT characterization of bentonite as sealing material in geological radioactive waste disposal

  • Melvin B. Diaz;Sang Seob Kim;Gyung Won Lee;Kwang Yeom Kim;Changsoo Lee;Jin-Seop Kim;Minseop Kim
    • Geomechanics and Engineering
    • /
    • 제34권4호
    • /
    • pp.449-459
    • /
    • 2023
  • The design and development of underground nuclear waste repositories should cover the performance evaluation of the different components such as the construction materials because the long term stability will depend on their response to the surrounding conditions. In South Korea, Gyeonju bentonite has been proposed as a candidate to be used as buffer and backfilling material, especially in the form of blocks to speed up the construction process. In this study, various cylindrical samples were prepared with different dry density and water content, and their physical and mechanical properties were analyzed and correlated with X-ray CT observations. The main objective was to characterize the samples and establish correlations for non-destructive estimation of physical and mechanical properties through the utilization of X-ray CT images. The results showed that the Uniaxial Compression Strength and the P-wave velocity have an increasing relationship with the dry density. Also, a higher water content increased the values of the measure parameters, especially for the P-wave velocity. The X-ray CT analysis indicated a clear relation between the mean CT value and the dry density, Uniaxial Compression Strength, and P-wave velocity. The effect of the higher water content was also captured by the mean CT value. Also, the relationship between the mean CT value and the dry density was used to plot CT dry densities using CT images only. Moreover, the histograms also provided information about the samples heterogeneity through the histograms' full width at half maximum values. Finally, the particle size and heterogeneity were also analyzed using the Madogram function. This function identified small particles in uniform samples and large particles in some samples as a result of poor mixing during preparation. Also, the μmax value correlated with the heterogeneity, and higher values represented samples with larger ranges of CT values or particle densities. These image-based tools have been shown to be useful on the non-destructive characterization of bentonite samples, and the establishment of correlations to obtain physical and mechanical parameters solely from CT images.

초음파 영상에서의 초고분해능 합성곱 신경망 알고리즘의 시뮬레이션 및 실험 연구 (Simulation and Experimental Studies of Super Resolution Convolutional Neural Network Algorithm in Ultrasound Image)

  • 이영진
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.693-699
    • /
    • 2023
  • 초음파는 의료분야에서 비파괴적 및 비침습적인 질병 진단에 널리 활용되고 있다. 진단의료영상의 질병진단 정확도를 향상시키기 위하여 공간 분해능을 향상시키는 것은 매우 중요하다. 본 연구에서는 초음파 영상에서의 초고분해능 합성곱 신경망 알고리즘 (super resolution convolutional neural network, SRCNN)을 모델링하여 적용 가능성을 분석하고자 한다. 연구는 Field II 시뮬레이션과 open source로 제공되는 임상 간 혈관종 초음파 영상을 사용한 실험 연구로 수행되었다. 제안하는 SRCNN 알고리즘은 저분해능 (low resolution, LR)에서 고분해능 (high resolution)으로 end-to-end 방식의 학습이 적용될 수 있도록 모델링하였다. 시뮬레이션 결과 Field II 프로그램을 통한 팬텀 영상에서의 반치폭 값은 SRCNN을 사용하였을 때 LR에 비하여 41.01% 향상되는 것을 확인하였다. 또한, 최대신호대잡음비 (peak to signal to noise ratio, PSNR)와 구조적 유사도 지표 (structural similarity index, SSIM)) 평가 결과는 시뮬레이션과 실제 간 혈관종 영상에서 SRCNN이 가장 우수한 값으로 도출되었다. 결론적으로 SRCNN의 초음파 영상에서의 적용 가능성을 증명하였고, 나아가 다양한 진단의료분야에서의 사용이 가능할 것으로 기대한다.

Coronary Artery Lumen Segmentation Using Location-Adaptive Threshold in Coronary Computed Tomographic Angiography: A Proof-of-Concept

  • Cheong-Il Shin;Sang Joon Park;Ji-Hyun Kim;Yeonyee Elizabeth Yoon;Eun-Ah Park;Bon-Kwon Koo;Whal Lee
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.688-698
    • /
    • 2021
  • Objective: To compare the lumen parameters measured by the location-adaptive threshold method (LATM), in which the inter- and intra-scan attenuation variabilities of coronary computed tomographic angiography (CCTA) were corrected, and the scan-adaptive threshold method (SATM), in which only the inter-scan variability was corrected, with the reference standard measurement by intravascular ultrasonography (IVUS). Materials and Methods: The Hounsfield unit (HU) values of whole voxels and the centerline in each of the cross-sections of the 22 target coronary artery segments were obtained from 15 patients between March 2009 and June 2010, in addition to the corresponding voxel size. Lumen volume was calculated mathematically as the voxel volume multiplied by the number of voxels with HU within a given range, defined as the lumen for each method, and compared with the IVUS-derived reference standard. Subgroup analysis of the lumen area was performed to investigate the effect of lumen size on the studied methods. Bland-Altman plots were used to evaluate the agreement between the measurements. Results: Lumen volumes measured by SATM was significantly smaller than that measured by IVUS (mean difference, 14.6 mm3; 95% confidence interval [CI], 4.9-24.3 mm3); the lumen volumes measured by LATM and IVUS were not significantly different (mean difference, -0.7 mm3; 95% CI, -9.1-7.7 mm3). The lumen area measured by SATM was significantly smaller than that measured by LATM in the smaller lumen area group (mean of difference, 1.07 mm2; 95% CI, 0.89-1.25 mm2) but not in the larger lumen area group (mean of difference, -0.07 mm2; 95% CI, -0.22-0.08 mm2). In the smaller lumen group, the mean difference was lower in the Bland-Altman plot of IVUS and LATM (0.46 mm2; 95% CI, 0.27-0.65 mm2) than in that of IVUS and SATM (1.53 mm2; 95% CI, 1.27-1.79 mm2). Conclusion: SATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM.

Free-Breathing Motion-Corrected Single-Shot Phase-Sensitive Inversion Recovery Late-Gadolinium-Enhancement Imaging: A Prospective Study of Image Quality in Patients with Hypertrophic Cardiomyopathy

  • Min Jae Cha;Iksung Cho;Joonhwa Hong;Sang-Wook Kim;Seung Yong Shin;Mun Young Paek;Xiaoming Bi;Sung Mok Kim
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1044-1053
    • /
    • 2021
  • Objective: Motion-corrected averaging with a single-shot technique was introduced for faster acquisition of late-gadolinium-enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging while free-breathing. We aimed to evaluate the image quality (IQ) of free-breathing motion-corrected single-shot LGE (moco-ss-LGE) in patients with hypertrophic cardiomyopathy (HCM). Materials and Methods: Between April and December 2019, 30 patients (23 men; median age, 48.5; interquartile range [IQR], 36.5-61.3) with HCM were prospectively enrolled. Breath-held single-shot LGE (bh-ss-LGE) and free-breathing moco-ss-LGE images were acquired in random order on a 3T MR system. Semi-quantitative IQ scores, contrast-to-noise ratios (CNRs), and quantitative size of myocardial scar were assessed on pairs of bh-ss-LGE and moco-ss-LGE. The mean ± standard deviation of the parameters was obtained. The results were compared using the Wilcoxon signed-rank test. Results: The moco-ss-LGE images had better IQ scores than the bh-ss-LGE images (4.55 ± 0.55 vs. 3.68 ± 0.45, p < 0.001). The CNR of the scar to the remote myocardium (34.46 ± 11.85 vs. 26.13 ± 10.04, p < 0.001), scar to left ventricle (LV) cavity (13.09 ± 7.95 vs. 9.84 ± 6.65, p = 0.030), and LV cavity to remote myocardium (33.12 ± 15.53 vs. 22.69 ± 11.27, p < 0.001) were consistently greater for moco-ss-LGE images than for bh-ss-LGE images. Measurements of scar size did not differ significantly between LGE pairs using the following three different quantification methods: 1) full width at half-maximum method; 23.84 ± 12.88% vs. 24.05 ± 12.81% (p = 0.820), 2) 6-standard deviation method, 15.14 ± 10.78% vs. 15.99 ± 10.99% (p = 0.186), and 3) 3-standard deviation method; 36.51 ± 17.60% vs. 37.50 ± 17.90% (p = 0.785). Conclusion: Motion-corrected averaging may allow for superior IQ and CNRs with free-breathing in single-shot LGE imaging, with a herald of free-breathing moco-ss-LGE as the scar imaging technique of choice for clinical practice.

탄소입자 치료 시 열가소성 고정기구의 공기층에 따른 선량 변화 평가 (Evaluation of Dose Variation according to Air Gap in Thermoplastic Immobilization Device in Carbon Ion)

  • 나예진;장지원;장세욱;박효국;이상규
    • 대한방사선치료학회지
    • /
    • 제35권
    • /
    • pp.33-39
    • /
    • 2023
  • 목 적: 환자 체표면과 고정기구 사이에 발생하는 공기층 두께에 따른 선량 변화를 치료 계획을 통해 알아보고자 한다. 대상 및 방법: 팬텀과 열가소성 고정기구 사이에 5 mm 두께의 Bolus를 0, 1, 2, 3장을 놓아 공기층의 두께를 조절하였고 고정기구를 씌워 총 4가지 조건으로 전산화 모의단층촬영을 시행하였다. 430 cGy (Relative Biological Effectiveness,RBE)씩 6번이 조사 되도록 계획하였으며, 임상표적체적의 95% 부피에 전달된 선량이 2580 cGy (RBE)가 되도록 치료 계획을 수립하였다. 임상표적체적의 선량은 Lateral dose profile의 반치폭값으로 평가하였고 피부 선량은 선량 체적 곡선으로 평가하였다. 결 과: 임상표적체적에서 Lateral dose profile 반치폭 값은 4.89, 4.86, 5.10, 5.10 cm로 나타났다. 피부에서 4가지 조건의 선량의 평균값은 D95%3.25±1.7 cGy (RBE), D30%1193.5±10.2 cGy (RBE)의 차이를 보였으며 처방 선량 1%에서의 피부 부피 값 평균은 83.22±4.8% 이내의 차이를 확인하였다. 공기층 두께 변화에 따른 임상표적체적과 피부에서의 선량 모두 큰 변화를 보이지는 않았다. 결론 : 탄소입자 치료를 위해 Solid 형태의 고정기구 제작 시 약간의 공기층은 CTV의 선량 적용 범위를 벗어나지 않는다.

  • PDF

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • 제24권10호
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

Quantitative T1 Mapping for Detecting Microvascular Obstruction in Reperfused Acute Myocardial Infarction: Comparison with Late Gadolinium Enhancement Imaging

  • Jae Min Shin;Eui-Young Choi;Chul Hwan Park;Kyunghwa Han;Tae Hoon Kim
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.978-986
    • /
    • 2020
  • Objective: To compare native and post-contrast T1 mapping with late gadolinium enhancement (LGE) imaging for detecting and measuring the microvascular obstruction (MVO) area in reperfused acute myocardial infarction (MI). Materials and Methods: This study included 20 patients with acute MI who had undergone 1.5T cardiovascular magnetic resonance imaging (CMR) after reperfusion therapy. CMR included cine imaging, LGE, and T1 mapping (modified look-locker inversion recovery). MI size was calculated from LGE by full-width at half-maximum technique. MVO was defined as an area with low signal intensity (LGE) or as a region of visually distinguishable T1 values (T1 maps) within infarcted myocardium. Regional T1 values were measured in MVO, infarcted, and remote myocardium on T1 maps. MVO area was measured on and compared among LGE, native, and post-contrast T1 maps. Results: The mean MI size was 27.1 ± 9.7% of the left ventricular mass. Of the 20 identified MVOs, 18 (90%) were detected on native T1 maps, while 10 (50%) were recognized on post-contrast T1 maps. The mean native T1 values of MVO, infarcted, and remote myocardium were 1013.5 ± 58.5, 1240.9 ± 55.8 (p < 0.001), and 1062.2 ± 55.8 ms (p = 0.169), respectively, while the mean post-contrast T1 values were 466.7 ± 26.8, 399.1 ± 21.3, and 585.2 ± 21.3 ms, respectively (p < 0.001). The mean MVO areas on LGE, native, and post-contrast T1 maps were 134.1 ± 81.2, 133.7 ± 80.4, and 117.1 ± 53.3 mm2, respectively. The median (interquartile range) MVO areas on LGE, native, and post-contrast T1 maps were 128.0 (58.1-215.4), 110.5 (67.7-227.9), and 143.0 (76.7-155.3) mm2, respectively (p = 0.002). Concordance correlation coefficients for the MVO area between LGE and native T1 maps, LGE and post-contrast T1 maps, and native and post-contrast T1 maps were 0.770, 0.375, and 0.565, respectively. Conclusion: MVO areas were accurately delineated on native T1 maps and showed high concordance with the areas measured on LGE. However, post-contrast T1 maps had low detection rates and underestimated MVO areas. Collectively, native T1 mapping is a useful tool for detecting MVO within the infarcted myocardium.

광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향 (EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.263-272
    • /
    • 2001
  • 저광도 중합법, 펄스 지연 중합법, 초고광도 중합법 등의 광조사 방식이 광중합형 복합레진 수복물에서의 중합수축 응력에 미치는 영향을 알아보기 위해 in vitro에서 미세 누출 실험을 하였다. 80개의 발거된 소구치의 협측면에 5급 와동을 형성하고, 600mW/$cm^2$로 30초간 광조사하는 보통 광도 중합군, 300mW/$cm^2$로 60초간 광조사하는 저광도 중합군, 400mW/$cm^2$로 2초간 광조사하고 5분간 기다린 후 800mW/$cm^2$로 10초간 최종 중합시키는 펄스-지연 중합군, 그리고 1930mW/$cm^2$의 광도로 3초간 광조사하는 초고광도 중합군 등의 4개의 군으로 나누어 hybrid 형의 광중합복합레진을 충전하고 각 군의 방법대로 중합한 후, 변연의 0.5mm 외부에 nail varnish를 도포하고 37$^{\circ}C$, 2% metylene blue 용액에 24시간 동안 침적시켰다. 시편을 아크릴릭 레진에 매몰한 후 수복물의 중앙에서 종절단하여 입체현미경하에서 그 단면을 관찰한 후 법랑질과 상아질 변연으로 나누어 색소의 침투도를 측정하여 다음과 같은 결과를 얻었다. 1. 펄스 지연 중합군의 색소 침투도는 법랑질과 상아질 변연 모두에서 보통광도, 저광도 및 초고광도 중합군과 유의한 차이를 보이지 않았다(p>0.05). 2. 상아질 변연에서 초고광도 중합군은 보통광도 중합군과 저광도 중합군에 비해 유의하게 높은 색소 침투도를 보였다(p<0.05). 3. 법랑질 변연에서의 4개 군의 색소 침투도는 서로 유의한 차이를 보이지 않았다(p>0.05). 4. 모든 군에서 상아질 변연에서의 색소 침투도는 법랑질군에서의 색소 침투도에 비해 유의하게 높았다(p<0.05).

  • PDF