• Title/Summary/Keyword: Half Drop

Search Result 87, Processing Time 0.024 seconds

A Study on the Atomization Characteristics of Effervescent Atomizer with PDPA (PDPA를 이용한 기체주입미립화기의 미립화 특성에 관한 연구)

  • Kim, Hyung-Gon;Yano, Toshiaki;Song, Kyu-Keun;Jung, Byong-Koog;Jung, Jae-Youn;Cho, Tae-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1316-1321
    • /
    • 2004
  • An experimental study is performed on atomization characteristics and stable operating condition for injection of high viscous waste vegetable oil using effervescent atomizer with two aerator tubes. Consideration is given to the effects of ALR and liquid viscosity on the velocity and mean diameter of the injected droplet. It is found that (i) as ALR increases, the axial velocity of the droplet is increased, while half-velocity width and SMD are decreased regardless of the change in liquid viscosities, (ii) the rate of fine drop distribution occupied in the total spray field is increased with an increasing in ALR, and (iii) the effect of viscosity on atomization characteristics is minor.

  • PDF

Analysis of Transmission Characteristics for Cascaded WDM Optical Add / Drop Multiplexers with Crosstalk , ASE Noise , and Extinction Ratio (WDM 광 분기 / 결합 시스템에서의 누화 , ASE 잡음 , 소광비가 전송특성에 미치는 영향분석)

  • Lee, Sang-Rok;Seo, Wan-Seok;Lee, Sung-Un
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.2
    • /
    • pp.1-8
    • /
    • 1999
  • We analyze the transmission performance of WDM system based on cascaded optical add/drop multiplexers. The considered factors degrading the performance in this paper include the intra-channel corosstalk caused from space switches and demultiplexers/multiplexers, the amplified spontaneous emission noise, and the extinction ratio. To ensure the power penalty within 1dB, the extinction ration more than 13dB, the switch corosstalk less than 39dB, and the demultiplexer/multiplexer crosstalk less than 20dB are required. Under the assumption of switch corosstalk less than 30dB, performance degradation due to the ASE noise is dominant compared to the crosstalk. With the fixed decision threshold in an optical receiver, the maximum number of cascaded nodes reduces to a half compared to the case of the optimum decision threshold.

  • PDF

Study on Smart Cooling Technology by Acoustic Streaming Generated by Ultrasonic Vibration Using 3D PIV (3차원 PIV를 활용한 초음파 진동에 의해 발생된 음향 유동을 이용한 스마트 냉각법 연구)

  • Lee, Dong-Ryul;Loh, Byoung-Gook;Kwon, Ki-Jung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1078-1088
    • /
    • 2010
  • In order to analyze the quantitative characteristics of acoustic streaming, experimental setup of 3-D stereoscopic PIV(particle imaging velocimetry) was designed and quantitative ultrasonic flow fields in the gap between the ultrasonic vibrator and heat source were measured. Utilizing acoustic streaming induced by ultrasonic vibration, surface temperature drop of cooling object was also measured. The study on smart cooling method by acoustic streaming induced by ultrasonic vibration was performed due to the empirical relations of flow pattern, average flow velocity, different gaps, and enhancement on cooling rates in the gap. Average velocity fields and maximum acoustic streaming velocity in the open gap between the stationary cylindrical heat source and ultrasonic vibrator were experimentally measured at no vibration, resonance, and non-resonance. It was clearly observed that the enhancement of cooling rates existed owing to the acoustic air flow in the gap at resonance and non-resonance induced by ultrasonic vibration. The ultrasonic wave propagating into air in the gap creates steady-state secondary eddy called acoustic streaming which enhances heat transfer from the heat source to encompassing air. The intensity of the acoustic streaming induced by ultrasonic vibration experimentally depended upon the gap between the heat source and ultrasonic vibrator. The ultrasonic vibration at resonance caused the increase of the acoustic streaming velocity and convective heat transfer augmentation when the flow fields by 3D stereoscopic PIV and temperature drop of the heat source were measured experimentally. The acoustic streaming velocity of air enhancement on cooling rates in the gap is maximal when the gap agrees with the multiples of half wavelength of the ultrasonic wave, which is specifically 12 mm.

A Morphologic Study on the Effect of the Vascular Endothelial Growth Factor in the Anastomosis of the Rat Femoral Artery (쥐에서 대퇴 동맥 문합술시 투여한 혈관내피성장인자의 효과에 대한 형태학적 연구)

  • Lee, Jun-Mo;Lee, Young-Keun
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.2
    • /
    • pp.101-106
    • /
    • 2004
  • Purpose : This study evaluated the effect of VEGF in the arterial anastomosis by using light and electron microscopy. Marerials and method : Rats underwent femoral arterial end-to-end anastomosis after transection and topical VEGF treatment. The proximal and distal segments of the femoral arteries was drenched with 1 drop of VEGF $(100ng/100{\mu}l/bottle)$. and when half of the repair was finished, the other 1 drop was drenched and then the repair was continued to complete the anastomosis. Gross and histologic characteristics of arterial wall were assessed after 3 days, 1, 3 and 5 weeks. In the control group, normal saline solution instead of VEGF was dropped with the same method in the anastomosis. Results : The histologic findings of the arterial wall were the vascular remodeling with the infiltration of inflammatory cells at early stages and the tissue fibrosis at lately stages in the anastomotic sites of the control and the VEGF-treated groups. The scanning electron microscopic results were; (1) the anastomotic sites were covered by many irregular cells with long cytoplasmic processes at the early stages. (2) After 1 week, endothelial cells started to cover the anastomotic sites. (3) After 3 weeks, the anastomotic sites were partially covered by endothelial cells in the control group. (4) After 5 weeks, the anastomotic sites were completely covered by endothelial cells in the control and VEGF-treated groups. (5) In the VEGF-treated group, the anastomotic site was completely covered by endothelial cells which directed parallel to longitudinal axis of arteries after 3 weeks. Conclusion : Topical VEGF maintained luminal integrity by decreasing fibrosis and increasing re-endothelialization. These findings suggest that topical VEGF may be a promising new strategy to enhance healing and improve the outcome of vascular anastomosis.

  • PDF

High Step-up Interleaved CCM-ZVZCS Converters (고승압 인터리빙 CCM-ZVZCS 컨버터)

  • Park, Yo-Han;Choi, Se-Wan;Choi, Woo-Jin;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.114-121
    • /
    • 2011
  • This paper proposes a soft-switching interleaved boost converter which is suitable for high step-up and high power applications. Compared to the conventional boost converter the proposed converter can achieve approximately doubled voltage gain using the same duty cycle. The voltage ratings of the switch and diode are reduced to half, which result in the use of devices with lower $R_{DS(ON)}$ and on drop leading to reduced conduction losses. Also, voltage ratings of the passive components are reduced, and therefore the total energy volume is reduced to half. Further, the switch is turned on with ZVS in the CCM operation, and the diode is turned off with ZCS which results in negligible surge caused by diode reverse recovery leading to reduced switching losses. The validity of the proposed converter is proved through a 2kW prototype.

AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System (인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어)

  • Park, Gwi-Geun;Choi, Jae-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

On the Fixing of the Shoulder Blade Level during Tight Fitting by the Draping Design (입체 재단법에 의한 Tight Fitting시 등폭 기준선의 설정에 관한여)

  • 이순섭
    • The Research Journal of the Costume Culture
    • /
    • v.4 no.3
    • /
    • pp.373-381
    • /
    • 1996
  • Draping design system organized by European about 13C has been developed greatly for a long while, but for the purpose of the practical use the Dress form similar to human body has been needed. In order to make three-dimensional effect as fitting Muslin ot the Dress form. the Basic lien has to be established in Muslin and Dress form each. At this time, Shoulder-blade level is indicated from various angles : measure down 10cm from the back neck point, a quarter of the back neck point to the waist lie, the half-way point between neckline and bust line, measure down 41 inches from the back neck line, measure down 3 inches from the top edge of the muslin at center back and cross mark for neck line, and so forth. This study established the Basic line through the two ways of them (B.N.P∼B.L/2, B.N.P∼W.L/4), did tight fitting to the 5 kinds of Dress forms which ar normal type in the drop value(the difference between hip circumference and bust circumference), and acquired Basic Pattern. After the experiment, fitness are throughly investigate by statistical analysis of measurements. As a result, this study finds out that fit is proper when shoulder blade level is situated on a fourth of the back neck point to the waist line and a quarter point between back neck point and waist line, and waist dart is situated on the back center line and princess line.

  • PDF

A Theoretical Analysis on Somatotyping of Elderly Women (노년기 여성의 체형 연구에 대한 이론적 분석)

  • Lee, Eun-Jung
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.4 no.1 s.7
    • /
    • pp.35-41
    • /
    • 2006
  • From 1995 to 2005 the information related to clothing and textiles publicized by 6 journals regarding Elder Women's body type was collected and analyzed. The results are as follows. 1. It has been investigated into the elder woman's body type since 1995, and this subject needs a detailed study. in audition, investigation into woman's body type has been studied parts of the body for clothing construction. 2. Analysis result for measure area preponderance(Seoul area and local metropolitan city) of area, measure subject number mainly to large scale group more than 300 people that measure is consisting most know can. 3. Where the way of measurement is concerned, there are direct measurements more than indirect measurements. In case of using just direct measurement, the study often mentions necessity of indirect measurements. Therefore it is thought simultaneous measurement is the most desirable. 4. A Body type characteristic of elder woman shows a size of every part diminishes as growing older. Owing mainly to obesity of waist and abdomen, they have a changed body a measure of around the abdomen is bigger than around the hips. hips drop and the upper half of the body down, and besides, feet are changed into the flat.

  • PDF

A New Embedded Compression Algorithm for Memory Size and Bandwidth Reduction in Wavelet Transform Appliable to JPEG2000 (JPEG2000의 웨이블릿 변환용 메모리 크기 및 대역폭 감소를 위한 새로운 Embedded Compression 알고리즘)

  • Son, Chang-Hoon;Song, Sung-Gun;Kim, Ji-Won;Park, Seong-Mo;Kim, Young-Min
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.1
    • /
    • pp.94-102
    • /
    • 2011
  • To alleviate the size and bandwidth requirement in JPEG2000 system, a new Embedded Compression(EC) algorithm with minor image quality drop is proposed. For both random accessibility and low latency, very simple and efficient hadamard transform based compression algorithm is devised. We reduced LL intermediate memory and code-block memory to about half size and achieved significant memory bandwidth reductions(about 52~73%) through proposed multi-mode algorithms, without requiring any modification in JPEG2000 standard algorithm.

Arrangement Methods of Pattern and Weaving Types of Fabrics During 16~17th Century - Centering Flower Patterned Fabrics of Exhumed Clothing in Chosun Dynasty - (16~17세기 직물유형과 문양의 배치구도에 관한 연구 - 조선시대 출토복식에 나타난 화문직을 중심으로 -)

  • Park, Mun-Young;Kim, Ho-Jung;Park, Ok-Lyun
    • Fashion & Textile Research Journal
    • /
    • v.8 no.4
    • /
    • pp.400-406
    • /
    • 2006
  • The purpose of this study is to investigate characteristics of arrangement methods and weaving types of fabrics during 16-17 century. Research was done through the references of exhumed clothing in Chosun Dynesty. Seeing the waving types of fabrics of flower patterned fabrics of total 108 items, satin damask(Dahn) was 71items, took the majority. And the next order was twill(Neung) and plain(Ju). It means Dahn was the most popular fabric among the upper classes. It was regarded as one of the noble textiles, because of its luxurious appearance and pleasant touch. Flower patterned plain fabric(Munju) was found only 9items, even though the plain fabric was the most common used type. Assumed for the reason, Chosun government had restrict to extravagance of the people. In terms of the arrangement of flower pattern, it can be classified into three methods. The most common arrangement method was Arabesque type, followed by open order shaped type and scattering shaped type. In the repetition of pattern, there were brick-shaped pattern and half drop pattern which were spread flower pattern all over the surface of fabric.