• 제목/요약/키워드: Hair-pin

검색결과 53건 처리시간 0.018초

Experimental Results of New Ion Source for Performance Test

  • 김태성;정승호;장두희;이광원;인상열
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.269-269
    • /
    • 2012
  • A new ion source has been designed, fabricated, and installed at the NBTS (Neutral Beam Test Stand) at the KAERI (Korea Atomic Energy Research Institute) site. The goalis to provide a 100 keV, 2MW deuterium neutral beam injection as an auxiliary heating of KSTAR (Korea Super Tokamak Advanced Research). To cope with power demand, an ion current of 50 A is required considering the beam power loss and neutralization efficiency. The new ion source consists of a magnetic cusp bucket plasma generator and a set of tetrode accelerators with circular copper apertures. The plasma generator for the new ion source has the same design concept as the modified JAEA multi-cusp plasma generator for the KSTAR prototype ion source. The dimensions of the plasma generator are a cross section of $59{\times}25cm^2$ with a 32.5 cm depth. The anode has azimuthal arrays of Nd-Fe permanent magnets (3.4 kG at surface) in the bucket and an electron dump, which makes 9 cusp lines including the electron dump. The discharge properties were investigated preliminarily to enhance the efficiency of the beam extraction. The discharge of the new ion source was mainly controlled by a constant power mode of operation. The discharge of the plasma generator was initiated by the support of primary electrons emitted from the cathode, consisting of 12 tungsten filaments with a hair-pin type (diameter = 2.0 mm). The arc discharge of the new ion source was achieved easily up to an arc power of 80 kW (80 V/1000 A) with hydrogen gas. The 80 kW capacity seems sufficient for the arc power supply to attain the goal of arc efficiency (beam extracted current/discharge input power = 0.8 A/kW). The accelerator of the new ion source consists of four grids: plasma grid (G1), gradient grid (G2), suppressor grid (G3), and ground grid (G4). Each grid has 280 EA circular apertures. The performance tests of the new ion source accelerator were also finished including accelerator conditioning. A hydrogen ion beam was successfully extracted up to 100 keV /60 A. The optimum perveance is defined where the beam divergence is at a minimum was also investigated experimentally. The optimum hydrogen beam perveance is over $2.3{\mu}P$ at 60 keV, and the beam divergence angle is below $1.0^{\circ}$. Thus, the new ion source is expected to be capable of extracting more than a 5 MW deuterium ion beam power at 100 keV. This ion source can deliver ~2 MW of neutral beam power to KSTAR tokamak plasma for the 2012 campaign.

  • PDF

주파수 잠금회로를 이용한 발진기의 위상잡음 개선 (Improvement of Phase Noise for Oscillator Using Frequency Locked Loop)

  • 김욱래;이창대;김용남;임평순;이동현;염경환
    • 한국전자파학회논문지
    • /
    • 제27권7호
    • /
    • pp.635-645
    • /
    • 2016
  • 본 논문에서는 주파수 잠금회로(FLL: Frequency Locked Loop)를 이용하여 발진기의 위상잡음을 개선할 수 있음을 보였다. 1차적으로 헤어-핀 공진기를 이용하여 전압제어발진기(VCO)를 제작하였다. 제작된 VCO는 발진주파수 5 GHz에서 위상잡음을 측정한 결과, 1 kHz offset 주파수에서 -53.1 dBc/Hz를 보였다. 위상잡음을 개선하기 위하여, VCO에 5 GHz 공진기로 구성된 주파수 검출기(frequency detector), 루프 필터, 전위변환기(level shifter)를 이용 궤환회로를 구성, 주파수 잠금회로를 구성하였다. 제작된 주파수 잠금회로는 5 GHz의 주파수에서 발진하고, 1 kHz offset 주파수에서 -120.6 dBc/Hz의 위상잡음을 보였다. 따라서 주파수 잠금회로를 이용, VCO의 위상잡음을 획기적으로 약 67.5 dB 개선할 수 있음을 보였다. 또한, 얻어진 주파수 잠금회로를 이용한 발진기의 위상잡음 성능은 수정발진기의 위상잡음과 비견할만한 것이다.

개량형 열회수 시스템의 열교환 성능 (Heat Exchange Performance of Improved Heat Recovery System)

  • 서원명;윤용철;권진근
    • 생물환경조절학회지
    • /
    • 제12권3호
    • /
    • pp.107-113
    • /
    • 2003
  • 본 연구에서는 온실의 온풍식 난방시스템 연통에 장착할 수 있는 폐열 회수기의 성능 개선을 목적으로 기 설계된 세 가지 열교환 장치와 기존의 장치에서 열교환 면적과 파이프의 두께 및 공기흐름 방향을 개량한 새 열교환 장치에 대해 열회수 성능을 실험적으로 비교 분석하였다. 그 결과 기존의 열 교환장치인 A형, B형 및 C형의 열회수 성능은 동일 송풍전입에서 각각 42.2%, 40.6% 및 54.4% 정도였으나 , 새로 개량된 D형은 69.2%로써 가장 현저히 높게 나타났다. 그러나 열회수용 공기의 흐름방향 변화에 따른 열회수 성능 개선효과 (A형 대비 B형)는 없는 것으로 나타나 적정 송풍기 용량이라면 직선형이 공기의 흐름방향 180${\circ}C$ 굴절시키는 헤어핀형보다 효과적인 것으로 판단된다. 결국 열회수 성능은 열회수 시스템의 열교환 면적과 열교환 파이프의 두께 및 풍속에 크게 좌우되는 것으로 나타났다. 따라서, 열교환 파이프의 내구성 등 을 고려하여 기능한 한 범위 내에서 열 교환면적을 증대시키거나 열교환 파이프의 두께를 앓게 하고 풍속을 증대시키는 것이 열회수 성능 개선효과와 직결됨을 알 수 있었다. 그리고 송풍기 용량이 필요이상으로 큰 경우, 소비전력이 많게 되는 등의 문제가 있기 때문에 적정용량 및 제품의 안정성을 고려하여 선택해야 할 것으로 판단되었다.