지역별 프리쿨링 시스템의 에너지 절감 분석 (Analysis of Energy Reduction of Free Cooling System with Regions of South Korea)

  • 윤정인;손창효;최광환;백승문;허정호;김영민
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.82-88
    • /
    • 2014
  • Using low outdoor temperature, free cooling system is used in a data center or industrial air-conditioning for energy saving. Because use of IT equipment has increased in some office building recently, there is a growing trend towards using free cooing system. Free cooling system performance is influenced by outdoor temperature. Therefore the performance is different with regions. In this study, performance characteristic of free cooling system is analysed and energy reduction is compared with some regions. Selected regions are 4 cities; including Ulsan analyzed in preceding research, Seoul, ChunCheon and Daejeon. The Aspentech software HYSYS 8.0v was used to conduct the analysis of free cooling system based on temperature per hour of 4 cities in 2013, respectively. The main result is following as. Free cooing system in this study has energy saving effect when outdoor temperature below $7^{\circ}C$. Becuase temperature of Chuncheon is relatively low, using free cooling system can conserve most air-conditioning energy. Energy reduction amount of Seoul is 11%, Chuncheon is 17.5%, Deajeon is 15%, Ulsan is 14%. In case of large scale of air-conditioning, it is reasonable to use free cooling system although the system is used in Seoul.

Reformate 분리공정에서의 열복합 증류탑 설계 (Design of Reformate Fractionation Process with Thermally Coupled Distillation Column)

  • 이주영
    • 한국산학기술학회논문지
    • /
    • 제12권5호
    • /
    • pp.2445-2450
    • /
    • 2011
  • 화학공정 모사 소프트웨어인 HYSYS를 사용하여 Reformate 분리 공정을 열복합 증류탑으로 설계하였다. 열복합 증류탑 설계 방법을 자세히 하였고, 모사 결과를 일반 증류탑과 비교한 결과 제시된 열복합 증류탑 설계 방법이 간단하고 효율적이라는 것을 알 수 있었다. 같은 tray 단수하에서 열복합 증류탑은 일반 증류탑 대비 약 12.2% 에너지가 절약됨을 알 수 있었다.

초저온 캐스케이드 냉동사이클의 LNG 열교환기 압력강하 특성 (The pressure drop characteristics in LNG heat exchanger of cryogenic cascade refrigeration cycle)

  • 윤정인;최광환;곽진우;손창효;백승문
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.376-381
    • /
    • 2012
  • Natural gas is converted in to LNG by chilling and liquefying the gas to the temperature of $-162^{\circ}C$, when liquefied, the volume of natural gas is reduced to 1/600th of its standard volume. This gives LNG the advantage in transportation. The pressure dorp of the cascade liquefaction cycle was investigated and simulated using HYSYS software. The simulation results showed that the pressure drop in the LNG heat exchanger is set to 50 kPa considering the increase in the compressor work of cryogenic cascade liquefaction cycle.

  • PDF

고효율 혼합 냉매 천연 가스 액화 공정에 대한 고찰 (Analysis of high efficiency natural gas liquefaction cycle with mixed refrigerant)

  • 백승환;황규완;정상권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.181-185
    • /
    • 2008
  • The new concept for liquefaction of natural gas has been designed and simulated in this paper. Conventional liquefaction cycles are usually composed with Joule-Thomson valves at lower temperature refrigerant cycle. The new concept of natural gas liquefaction is discussed. The main difference with conventional liquefaction process is the presence of the turbine at low temperature of MR (mixed refrigerant) cycle. The turbine acts as expander but also as an energy generator. This generated energy is provided to the compressor which consumes energy to pressurize refrigerants. The composition of the mixed refrigerant is investigated in this study. Components of the refrigerant are methane, propane and nitrogen. Composition for new process is traced with Aspen HYSYS software. LNG heat exchangers are analyzed for the new process. Heating and cooling curves in heat exchangers were also analyzed.

  • PDF

중간 열교환기를 이용한 열복합 증류탑의 운전성 향상 (Improved Operability in a Fully Thermally Coupled Distillation Column with an Intermediate Heat Exchanger)

  • 정수영;김영한
    • 제어로봇시스템학회논문지
    • /
    • 제12권9호
    • /
    • pp.945-953
    • /
    • 2006
  • Though a fully thermally coupled distillation column consumes less energy than an original column, it is not widely implemented in practice due to its operational difficulty. A new fully thermally coupled distillation column is proposed for the operability improvement, and its performance is investigated. The main improvement is the separation of a main column to give an upper and lower columns and the installation of an intermediate heat exchanger between them to regulate the fluctuation of product compositions. A proper manipulation of column pressure in the separated main columns made easy vapor flow without a compressor. The operability improvement is examined in a hexane process from the dynamic simulation using a commercial design software HYSYS. The simulation results indicate that the coupling among inputs and outputs is loosened to make easy manipulation of product compositions in the proposed distillation system.

분리주탑형 열복합 증류탑에서의 증류실험 (Experimental Distillation Using a Fully Thermally Coupled Distillation Column with Separated Main Columns)

  • 박영민;강현욱;김영한
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1197-1201
    • /
    • 2006
  • In order to improve the operability in a fully thermally coupled distillation column the main column is separated into an upper and a lower column, and its design method is explained. With a distillation experiment using a two-inch column the operability of the proposed column is examined. Readily available methanol, ethanol and propanol are used as the feed, and the experimental result is compared with that of the HYSYS simulation. It is found from the experiment that the recovery ranges between 58.8% and 68% and the distillation efficiency is lower than that of the simulation. consumes less energy than an original column, it is not widely implemented in practice due to its operational difficulty. However, it is proved that the proposed distillation column can be operated without compressors and it can be practically utilized.

분리벽형 증류탑을 적용한 필름공정의 폐용매 회수공정 최적설계 (Optimal Design of Solvent Recovery Process with Dividing Wall Column for Film Making Process)

  • 이승현;조문신;이문용
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1209-1214
    • /
    • 2006
  • This paper presents an application of Dividing Wall Column(DWC) to the recovery of the waste solvent from the film making processes. The waste solvent feed contains MEK(Methyl-Ethyl-Ketone), Toluene, Cyclohexanone, and water. The commercial software $HYSYS^{TM}$ was used for rigorous simulation and analysis. Sensitivity analysis for several major design variables were carried out to achieve the optimal design of the process. Distribution of the internal vapor and liquid flows to the prefractionator and main sections is shown to be the most dominant design factor for energy saving efficiency in the DWC process. The simulation results also show that the solvent recovery process using the DWC significantly improves both the energy efficiency and the compactness of the solvent recovery process.

잠재적 폭발 위험성을 고려한 단단 혼합냉매 LNG 공정의 설계 변수 최적화 (Optimization of Single-stage Mixed Refrigerant LNG Process Considering Inherent Explosion Risks)

  • 김익현;단승규;조성현;이기백;윤인섭
    • Korean Chemical Engineering Research
    • /
    • 제52권4호
    • /
    • pp.467-474
    • /
    • 2014
  • 화학공정의 기초설계는 물질수지와 열수지 계산을 기초로 공정의 경제성을 확보하고 주어진 조건 내에서 원하는 제품을 생산 가능하도록 한다. 이 단계를 통해 공정은 사용될 물질과 반응, 설비의 구조와 운전 조건 등이 결정되기 때문에 이후 바뀔 수 없는 고유한 특성을 갖게 된다. 고유한 특성은 뛰어난 경제성일 수도 있지만 다양한 잠재적 위험요인을 내포하는 것일 수도 있다. 따라서 기초설계를 위한 공정모사와 정량적 위험성 평가 기법의 통합을 통해 보다 안전하면서도 경제적인 공정을 설계하는 것이 중요하다. 본 논문에서는 LNG 액화공정을 Aspen HYSYS를 이용하여 모사하고, 폭발 사고에 대한 정량적 위험성 평가를 수행함으로써 잠재적 위험성을 최소화하면서도 경제성을 고려하도록 설계변수를 결정하였다. 이를 위해 확률적 최적화 방법론을 이용하여 Aspen HYSYS의 최적화 한계를 극복하였고, Aspen HYSYS와 Matlab의 연동을 통해 정량적 위험성 평가의 정확성을 높이며 최적화를 용이하게 하였다. 정량적 위험성 평가 결과, 공정 변수 중 안전성 확보를 위해 중요한 변수는 혼합냉매의 압력이었고, 0.5~10%의 운전비용 증가를 통해 잠재적 위험성을 4~18% 줄일 수 있었다. 비용을 크게 증가시킬수록 위험성의 절대적 수치는 낮아지지만 비용 대비 위험성 감소의 효과는 떨어졌다. 이처럼 공정모사와 정량적 위험성 평가 기법의 통합은 태생적으로 보다 안전한 공정의 설계가 가능하게 하고, 기초설계 단계에서부터 공정 내 위험요인을 수치적으로 확인할 수 있어 위험요인이 적은 특성을 갖도록 공정을 설계하는데 도움이 될 것이다.

드라이쿨러를 적용한 외기냉수냉방 시스템 설계에 관한 연구 (A study on design for free cooling system using dry cooler)

  • 윤정인;백승문;허정호;김영민;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1027-1031
    • /
    • 2014
  • 외기냉수냉방 시스템은 공조나 산업공정에 사용되는 냉수를 저온의 외기를 이용하여 냉각하는 시스템으로 에너지를 절감하기위해 사용되며, 냉각시스템과 외기와 냉수가 열교환을 하는 드라이쿨러로 구성되어있다. 외기냉수냉방 시스템은 지속적인 냉방이 필요한 곳에 에너지절감효과가 뛰어나나 국내의 경우, 외기냉수냉방 시스템에 설계 기준과 자료가 미비하다. 따라서 본 연구에서는 상용프로그램 HYSYS를 이용하여, 드라이쿨러를 이용한 외기냉수냉방 시스템의 요소변화에 따른 성능을 비교 분석했으며 그 결과는 다음과 같다. 드라이쿨러의 냉각능력은 외기온도, 요구냉수온도, 열교환기의 LMTD (Logarithmic Mean Temperature Difference, 대수평균온도차)에 따라 변한다. 드라이쿨러는 외기온도가 낮을 수록 그 냉각능력이 증가하며, LMTD가 낮은 드라이쿨러가 LMTD가 높은 것에 비하여 고온의 외기온도에서 사용이 가능하였다. 외기온도가 극히 낮은 지역에서는 글리콜이 함유된 부동액을 사용해야하며 국내의 외기온도를 고려하였을 때, 글리콜농도 34%의 부동액이 적절한 것으로 판단된다. 냉동기에 적용될 작동유체의 경우, R22, R134a, R407C의 압축일을 비교했으며, R134a가 환경관련 규제와 에너지 사용측면에서 우수한 냉매로 사료된다.

해양지열발전용 다단재열재생사이클 성능해석 (Performance Analysis on the Multi Stage Reheater Regeneration Cycle for Ocean Geothermal Power Generation)

  • 이호생;차상원;정영권;김현주
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제17권2호
    • /
    • pp.116-121
    • /
    • 2014
  • 지열수를 온열원으로 사용하고, 해양심층수를 열침으로 사용하는 바이너리(binary) 지열 발전시스템은 기존 지열 발전시스템의 효율을 증대하기 위한 재열과정과 터빈출력을 향상시키기 위한 다단과정을 각각 또는 복합적으로 적용하여 다단재열재생사이클의 성능개선을 검토하였다. 사이클종류는 다단재열사이클(Multi Stage reheater cycle; MS), 다단재열재생사이클(Multi stage reheater regeneration cycle; MSR)이 있다. 작동유체는 R134a, R245fa를 적용하였으며 온열원의 온도가 $65^{\circ}C$, $75^{\circ}C$, $85^{\circ}C$ 열침은 $5^{\circ}C$를 적용하여 기본해석을 수행하였다. 본 논문에서는 온열원변화, 작동유체의 종류, 사이클의 종류에 따른 해양지열발전용 다단재열재생사이클의 출력 및 효율을 높이기 위한 해석을 수행하였다. 이를 열역학적 사이클로 모사하기 위한 상용 프로그램인 Aspen HYSYS(V8.0)를 이용하여 해석을 진행 하였다. 작동유체는 R245fa가 R134a보다 우수한 성능을 보였으며, 온열원의 변화와 각각의 사이클 종류에 따라 적절한 작동유체가 있음을 확인 할 수 있었다. 사이클의 출력 및 효율은 각각 MS사이클과 MSR사이클에서 좋은 성능을 나타냈다.