• 제목/요약/키워드: HVDC system

검색결과 377건 처리시간 0.036초

제주-해남 HVDC 시스템의 과도특성 분석 (Transient Performance of Cheju-Haenam Hvdc System)

  • 김찬기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권9호
    • /
    • pp.607-617
    • /
    • 2000
  • This paper deals with the dynamic performance of Cheju-Haenam HVDC system. The purpose of the simulation study is to verify the control characteristics of the HDVC and to analyse the dynamic performances. Especially because the HVDC system consists of analogue controller and digital controller the simulation is achieved with specification model considered nonlinear function. The dynamic performance simulations is performed by PSCAD/EMTDC

  • PDF

육지-제주간 2차 HVDC SYSTEM 개요 (The Introduction of #2 HVDC SYSTEM)

  • 장석한;유승환;신명식;이규용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.107-109
    • /
    • 2008
  • Cheju-Haenam HVDC transmission system start it's commercial operation since 1998. JEJU island is supplied with it's about 45% of total electric power from main land with HVDC link. In JEJU island, the demand of electric power is growing every year. With a current power supply, electric power reserve rate will be below the recommended one. For a stable power supply to JEJU island, KEPCO start a construction of #2 HVDC transmission system. This report is for introduction and understanding of #2 HVDC system which will be installed between JEJU island and main land. This report includes a specification of converter station and DC cable. KEPCO expect that this system will solve the power supply problem and maximum wind power plant capacity problem as well.

  • PDF

Operational characteristics analysis of a 8 mH class HTS DC reactor for an LCC type HVDC system

  • Kim, S.K.;Go, B.S.;Dinh, M.C.;Kim, J.H.;Park, M.;Yu, I.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권1호
    • /
    • pp.32-35
    • /
    • 2015
  • Many kinds of high temperature superconducting (HTS) devices are being developed due to its several advantages. In particular, the advantages of HTS devices are maximized under the DC condition. A line commutated converter (LCC) type high voltage direct current (HVDC) transmission system requires large capacity of DC reactors to protect the converters from faults. However, conventional DC reactor made of copper causes a lot of electrical losses. Thus, it is being attempted to apply the HTS DC reactor to an HVDC transmission system. The authors have developed a 8 mH class HTS DC reactor and a model-sized LCC type HVDC system. The HTS DC reactor was operated to analyze its operational characteristics in connection with the HVDC system. The voltage at both ends of the HTS DC reactor was measured to investigate the stability of the reactor. The voltages and currents at the AC and DC side of the system were measured to confirm the influence of the HTS DC reactor on the system. Two 5 mH copper DC reactors were connected to the HVDC system and investigated to compare the operational characteristics. In this paper, the operational characteristics of the HVDC system with the HTS DC reactor according to firing angle are described. The voltage and current characteristics of the system according to the types of DC reactors and harmonic characteristics are analyzed. Through the results, the applicability of an HTS DC reactor in an HVDC system is confirmed.

초고압 직류송전 시스템의 전력 동요억제를 위한 정지형 무효전력 보상기에 MGA-PI 보조제어기 설계 (A Design of MGA-Pl Supplementary Controller in SVC for Power Oscillation Damping of HVDC Transmission System)

  • 오태규;정형환;허동열;이정필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권7호
    • /
    • pp.317-326
    • /
    • 2002
  • In this paper, a methodology for optimal PI supplementary controller using the modified genetic algorithm has been proposed to the oscillation damping in HDVC transmission system. These study processes are summarized as the formulation for load flow calculation in HVDC transmission system with SVC, the investigations on the basic control in HVDC system, the mathematical modeling for dynamic characteristics analyses, and the optimal design of MGA based PI controller generation the supplementary control signal of SVC. Its properties were verified through a series of computer simulations including dynamic stability. It means that the application of MGA-PI controller in HVDC transmission system can contribute the propriety to the improvement of the stability in HVDC transmission system and the design of MGA-OI controller has been proved indispensible when applied to HVDC transmission system.

A Dynamic Performance Study of an HVDC System using a Hybrid Simulator

  • Kim Chan-Ki;Yang Byeong-Mo;Lee Hahk-Sung
    • Journal of Power Electronics
    • /
    • 제5권4호
    • /
    • pp.319-328
    • /
    • 2005
  • This paper deals with the development of a new type of simulator for the study of the dynamic performance of an HVDC scheme. The new simulator uses a digital model of the power equipment and an analogue model of the existing HVDC controller. This simulator is used to study the dynamic performance of the Cheju - Haenam HVDC system and to verify the control characteristics of the HVDC system. The paper discusses the simulator development requirements and criteria. The paper provides guidelines for the development of the simulator and presents the results of the simulation studies.

고조파 저감을 고려한 HVDC System용 AC 필터 설계 방법에 관한 연구 (Study of AC Filter Design considering Harmonic Mitigation for HVDC System)

  • 천이경;김현;최용길;이욱화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.209-210
    • /
    • 2015
  • High Voltage Direct Current(HVDC) System용 AC 필터는 특정 고조파 영역에서 낮은 임피던스를 제공하여 AC 계통으로 유입되는 고조파를 억제시킴과 동시에 무효전력의 공급원으로서의 역할도 수행한다. 대부분의 전류형 HVDC System은 12개의 Pulse로 동작하기 때문에 $12n{\pm}1$차의 특성고조파를 발생시키는데 HVDC System에서는 이러한 특성고조파들을 저감시키기 위한 Harmonic AC Filter가 주로 사용된다. 본 논문에서는 HVDC System용 AC 필터를 설계할 때 고조파 저감을 고려한 다목적 최적화 알고리즘을 제시함으로써, 향후 시스템의 안전성과 효율성 측면에서 기여할 수 있는 실제 HVDC System용 AC 필터 설계 적용에 큰 도움이 될 것으로 기대된다.

  • PDF

HVDC 케이블용 XLPE 절연 재료에 대한 DC/Impulse 중첩실험 시스템 구축 (Build-up of DC/Impulse Superposition Testing System for XLPE materials in HVDC cables)

  • 김정태;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1608-1609
    • /
    • 2011
  • In this study, in order to develop the evaluation method for XLPE materials for HVDC cables, DC/Impulse superposition testing system was builded up. Throughout the P-spice simulation, optimal values of the protection resistor for the DC generation system and the blocking capacitor for the Impulse generator were calculated. DC/Impulse superposition system showed good result maintaining their proper wave shapes and amplitudes. This system would be planned to apply to the evaluation of XLPE materials for HVDC cables.

  • PDF

제주 HVDC No. 2의 극간 상호작용 경험과 분석: 무정전 전력 송전을 위한 실용적 해결방안 (Experience and Analysis of Pole Interaction for Jeju HVDC No. 2: Practical Solution for Non-Interruptible Power Transfer)

  • 김희진;김찬기;박창환
    • 전력전자학회논문지
    • /
    • 제25권6호
    • /
    • pp.459-468
    • /
    • 2020
  • The pole interaction of the line-commutated converter high-voltage direct current (HVDC) is analyzed, and a practical solution that uses a surge arrester is proposed. Jeju HVDC No. 2 is a double-monopole HVDC link that has a rated power capacity of 2 × 200 MW and was commissioned in 2012. During normal operation, Jeju HVDC No. 2 is operated in the bipolar mode to minimize the loss caused by the dedicated metallic return. However, when one pole of the inverter valve is bypassed, a commutation failure can occur in the other pole. This phenomenon is called pole interaction in this work. This pole interaction interrupts the HVDC power transfer for almost 2 s and may affect the stability of the power system. This research proposes the installation of a surge arrester at the inverter neutral, which can be an effective and practical solution for pole interaction. The HVDC system is analyzed, and the residual voltage of the surge arrester is determined. Detailed simulation using PSCAD/EMTDC demonstrates that the proposed method eliminates the pole interaction of the bipolar-operated HVDC.

HVDC Control and Protection 시스템의 이중화에 대한 고찰 (The Study on the redundancy of HVDC Control and Protection System)

  • 문준모;이일화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.175-176
    • /
    • 2014
  • 본 논문은 HVDC C&P 시스템에 적용된 이중화 기술 및 기능을 설명한다. LS산전은 2009년 HVDC 사업을 착수한 이래 HVDC Control and Protection(C&P) System을 개발해 왔으며 현재 2010년부터 한국전력공사와 협동연구로 진행하고 있는 HVDC 제주 실증단지에 적용하여 실증운전 중이다. 당사가 개발한 HVDC C&P 시스템은 시스템의 신뢰성 및 가용성을 높이기 위해 Fully Redundancy 시스템으로 구성되고 Hot Standby 방식으로 제어 및 보호 알고리즘을 수행한다. 본 논문에서는 HVDC C&P 시스템의 구성과 제어기 및 네트워크의 이중화 구조에 대해 소개 하고자 한다.

  • PDF

제주계통에 적용 가능한 유형별 HVDC 시스템의 동적 안정도 연구 (A Study on Dynamic Stability of HVDC System Type which may be Applied the Jeju AC Network)

  • 권영훈;김용학;김찬기;최영도
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.270-277
    • /
    • 2008
  • Capacitor Commutated Converter HVDC(High Voltage Direct Current) 시스템은 무효전력의 수급이 작기 때문에 점호각이 180도까지 증가시킬 수 있으므로 취약한 계통에 적용이 가능하다. 따라서, 본 논문에서는 변압기와 밸브 사이에 직렬커패시터가 연결된 CCC 컨버터, CSCC 컨버터 및 전형적인 전류형 컨버터에 대해 분석하고, 계통의 안정도 측면에서 PSCAD/EMTDC로 CCC 컨버터의 HVDC를 모의함으로써 신뢰성이 높음을 제시하였다.