• Title/Summary/Keyword: HVDC line

Search Result 86, Processing Time 0.024 seconds

Investigation of a Hybrid HVDC System with DC Fault Ride-Through and Commutation Failure Mitigation Capability

  • Guo, Chunyi;Zhao, Chengyong;Peng, Maolan;Liu, Wei
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1367-1379
    • /
    • 2015
  • A hybrid HVDC system that is composed of line commutated converter (LCC) at the rectifier side and voltage source converter (VSC) in series with LCC at the inverter side is studied in this paper. The start-up strategy, DC fault ride-through capability, and fault recovery strategy for the hybrid HVDC system are proposed. The steady state and dynamic performances under start-up, AC fault, and DC fault scenarios are analyzed based on a bipolar hybrid HVDC system. Furthermore, the immunity of the LCC inverter in hybrid HVDC to commutation failure is investigated. The simulation results in PSCAD/EMTDC show that the hybrid HVDC system exhibits favorable steady state and dynamic performances, in particular, low susceptibility to commutation failure, excellent DC fault ride-through, and fast fault recovery capability. Results also indicate that the hybrid HVDC system can be a good alternative for large-capacity power transmission over a long distance byoverhead line.

Planning of HVDC System Applied to Korea Electric Power Grid

  • Choi, DongHee;Lee, Soo Hyoung;Son, Gum Tae;Park, Jung-Wook;Baek, Seung-Mook
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.105-113
    • /
    • 2018
  • This paper proposes pre-analysis on planning of high-voltage direct current (HVDC) transmission system applied to Korea electric power grid. HVDC transmission system for interface lines has been considered as alternative solution for high-voltage AC transmission line in South Korea since constructing new high-voltage AC transmission lines is challenging due to political, environmental and social acceptance problems. However, the installation of HVDC transmission system as interface line in AC grid must be examined carefully. Thus, this paper suggests three scenarios to examine the influences of the installation of HVDC transmission system in AC grid. The power flow and contingency analyses are carried out for the proposed scenarios. Power reserves in metro area are also evaluated. And then the transient stability analysis focusing on special protection scheme (SPS) operations is analyzed when critical lines, which are HVDC lines or high voltage AC lines, are tripped. The latest generic model of HVDC system is considered for evaluating the impacts of the SPS operations for introducing HVDC system in the AC grid. The analyses of proposed scenarios are evaluated by electromechanical simulation.

A Study on the HVDC Submarine Cable Fault Location Searching Case (HVDC 해저케이블 고장점 탐지 사례 연구)

  • Moon, Shin-Yong;Kim, Jeong-Dae;Jang, Seok-Han
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.138-140
    • /
    • 2006
  • 한국전력공사(이하 한전)에서는 제주지역 전력공급의 안정을 위해 '98년부터 국내 최초로 육지전력 계통과 연계하여 장거리 해저케이블 송전선로를 건설하여 운영하고 있다. 해저케이블은 해저에 포설되고 외부적 환경에 견디기 위해 육상케이블과 다른 많은 보호층을 포함하고 있어 설비의 유지보수에 많은 제약사항을 안고 있다. 특히 해남${\sim}$제주 연계선로는 기술적 장점 때문에 AC송전 대신 HVDC 송전을 하고 있어 한단계 Upgrade된 설비운영 기술이 필요하다. 본 고에서는 HVDC 해저 케이블의 설비운영에 있어 선로의 고장시 케이블의 고장점 위치를 탐지하는데 중점을 두어 실제 고장점 탐지 사례를 중심으로 HVDC 해저 케이블 고장점 탐지 방법 및 시험 결과를 검토하고 향후 유사 고장 발생에 효과적으로 대응하기 위한 절차를 제시하였다.

  • PDF

Feasibility Study of the application of HVDC System to Domestic Power System ' Design of the HVDC system for Sinokchun-Sedaegu 345kV Transmission line (직류변환 송전방식 국내도입 타당성 검토 : 신옥천-서대구 345kV송전선로 1회선 직류변환 설계)

  • Kim D. J.;Yoon J. Y.;Yang K. H.;Moon Y. H.;Lee D. I.;Shin G. Y.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.186-188
    • /
    • 2004
  • This paper describes the feasibility study of HVDC system application to KEPCO power system for increasing power transfer capability or the flexibility of power delivery from one area to the other using the existing transmission line. This paper assumes the 345kV transmission line connecting between Shinokchun and Sedaegu to be converted to the DC line by replacing the AC insulator with that of DC. Then, the HVDC bipole system of 1000MVA with $\pm300kV$ is designed and the contingency studies are carried out.

  • PDF

A Study on Selecting the Optimal Location of BTB HVDC for Reducing Fault Current in Metropolitan Regions Based on Genetic Algorithm Using Python (Python을 이용한 유전 알고리즘 기반의 수도권 고장전류 저감을 위한 BTB HVDC 최적 위치 선정 기법에 관한 연구)

  • Song, Min-Seok;Kim, Hak-Man;Lee, Byung Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1163-1171
    • /
    • 2017
  • The problem of fault current to exceed the rated capacity of a power circuit breaker can cause a serious accident to hurt the reliability of the power system. In order to solve this issue, current limiting reactors and circuit breakers with increased capacity are utilized but these solutions have some technical limitations. Back-to-back high voltage direct current(BTB HVDC) may be applied for reducing the fault current. When BTB HVDCs are installed for reduction in fault current, selecting the optimal location of the BTB HVDC without causing overload of line power becomes a key point. In this paper, we use genetic algorithm to find optimal location effectively in a short time. We propose a new methodology for determining the BTB HVDC optimal location to reduce fault current without causing overload of line power in metropolitan areas. Also, the procedure of performing the calculation of fault current and line power flow by PSS/E is carried out automatically using Python. It is shown that this optimization methodology can be applied effectively for determining the BTB HVDC optimal location to reduce fault current without causing overload of line power by a case study.

Insulation Design and Reliability Evaluation of ±80kV HVDC XLPE Cables

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1002-1008
    • /
    • 2014
  • This paper describes insulation design and its reliability evaluation of ${\pm}80kV$ HVDC XLPE cable. Recently, the construction of HVDC transmission system, which is combined overhead line with underground cable, has been completed. This system is installed with existing 154 kV AC transmission line on the same tower. In this paper, the lightning transient analysis is firstly reviewed for selection of basic impulse insulation level and nominal insulation thickness. Then the electrical performance tests including load cycle test and superimposed impulse test based on CIGRE TB 496 are performed to evaluate the reliability of newly designed HVDC cable. There is no breakdown for ${\pm}80kV$ HVDC XLPE cable during electrical performance test. Finally, this system is installed in Jeju island based on successful electrical performance test (Type test). After installation tests are also successfully completed.

MUSIC-based Diagnosis Algorithm for Identifying Broken Rotor Bar Faults in Induction Motors Using Flux Signal

  • Youn, Young-Woo;Yi, Sang-Hwa;Hwang, Don-Ha;Sun, Jong-Ho;Kang, Dong-Sik;Kim, Yong-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.288-294
    • /
    • 2013
  • The diagnosis of motor failures using an on-line method has been the aim of many researchers and studies. Several spectral analysis techniques have been developed and are used to facilitate on-line diagnosis methods in industry. This paper discusses the first application of a motor flux spectral analysis to the identification of broken rotor bar (BRB) faults in induction motors using a multiple signal classification (MUSIC) technique as an on-line diagnosis method. The proposed method measures the leakage flux in the radial direction using a radial flux sensor which is designed as a search coil and is installed between stator slots. The MUSIC technique, which requires fewer number of data samples and has a higher detection accuracy than the traditional fast Fourier transform (FFT) method, then calculates the motor load condition and extracts any abnormal signals related to motor failures in order to identify BRB faults. Experimental results clearly demonstrate that the proposed method is a promising candidate for an on-line diagnosis method to detect motor failures.

A Study on an Operation Strategy of Dual-Infeed HVDC System

  • Kim, Chan-Ki;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.45-52
    • /
    • 2017
  • This paper deals with the operation strategy of reactive power in a multi-infeed HVDC (MIHVDC) system, in which several converters are connected to the same or nearby separate AC buses. The potential problems concerning a MIHVDC system when feeding a weak AC network are as follows: the need for coordination of the recovery control, the possibility of voltage instability or low quality of the area connected to the MIHVDC system, and the risk of mutual commutation failures. These problems in MIHVDC systems are similar to those in single-infeed HVDC (SIHVDC) systems, but the differences with the phenomenon of the SIHVDC system are the interactions between converters. The main reason for the potential problems of HVDC systems (MIHVDC or SIHVDC) is voltage variation; therefore, to mitigate the voltage variations, the performances of the HVDC system should be enhanced. Consequently, to mitigate the potential problems of MIHVDC systems, several solutions are suggested in this study, including installing STATCOM and installing a line arrester on the tower. The study results will be applied to a multi-infeed HVDC system in Korea.

A Study on the Design of Triple-tuned Filter for Line Commutated Converter HVDC (HVDC시스템 적용을 위한 Triple-tuned 필터 설계방법 연구)

  • Lee, Seong-Doo;Choi, Soon-Ho;Kim, Chan-Ki;Cha, HanJu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1288-1296
    • /
    • 2015
  • The ac side current of a line commutated converter(LCC) high voltage direct current (HVDC) is characterized by highly non-sinusoidal waveform. If the harmonic current is allowed to flow in the connected ac network, it may cause unacceptable levels of distortion. Therefore, ac side filters are required as part of the total HVDC converter station, in order to reduce the harmonic distortion of the ac side current and voltage to acceptably low levels. The ac filters are also employed to compensate the requested reactive power because LCC HVDC also consume substantial reactive power. Among different types of filters, triple-tuned filters have been widely utilized for HVDC system. This paper presents two design methods of triple-tuned filter; equivalent method and parametric method. Using a parametric method, in particular this paper proposes a design algorithm for a triple tuned filter. Finally, the performance of the design algorithm is evaluated for a 250kV HVDC system in Jeju island. The results cleary demonstrate the effectiveness of proposed design method in harmonics reduction.

Analysis of the Ionized Fields around HVDC Transmission Line by the Use of the Charge Simulation Method (전하중첩법을 이용한 직류 송전선 주변 이온장 해석)

  • Min Suk-Won;Song Ki-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.6
    • /
    • pp.478-485
    • /
    • 2005
  • This paper analysed the ionized fields around HVDC transmission line by the use of the charge simulation method. As this is very complex and expressed by a non-linear partial differential equations, it is hard to solve problems analytically. So, we developed a computer program which can apply in multi-polar HVDC transmission line with conductor bundles and calculated conductor surface gradient, corona current density and ion charge density to prove validity of a proposed algorithm in this paper.

  • PDF