• 제목/요약/키워드: HVDC Model

검색결과 76건 처리시간 0.037초

Resonance Investigation and Active Damping Method for VSC-HVDC Transmission Systems under Unbalanced Faults

  • Tang, Xin;Zhan, Ruoshui;Xi, Yanhui;Xu, Xianyong
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1467-1476
    • /
    • 2019
  • Grid unbalanced faults can cause core saturation of power transformer and produce lower-order harmonics. These issues increase the electrical stress of power electronic devices and can cause a tripping of an entire HVDC system. In this paper, based on the positive-sequence and negative-sequence impedance model of a VSC-HVDC system as seen from the point of common connection (PCC), the resonance problem is analyzed and the factors determining the resonant frequency are obtained. Furthermore, to suppress over-voltage and over-current during resonance, a novel method using a virtual harmonic resistor is proposed. The virtual harmonic resistor emulates the role of a resistor connected in series with the commutating inductor without influencing the active and reactive power control. Simulation results in PSCAD/EMTDC show that the proposed control strategy can suppress resonant over-voltage and over-current. In addition, it can be seen that the proposed strategy improves the safety of the VSC-HVDC system under unbalanced faults.

해저케이블 고장점 탐지시스템 육상 특성 연구 (Study on the Property of Land for Fault Point Searching System of Submarine Cable)

  • 안용호;정길조;유희영;정창수;박찬영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.578-579
    • /
    • 2005
  • HVDC(High Voltage Direct Current) is an underwater cable between Jeju Island and Haenam in main land and supplies approximately 50% of electrical usage in Jeju Island. If there is any power failure due to HVDC, it will cost approximately 50,000 US dollars per day including Thermal Electrical Generation. Therefore it is absolutely necessary to recover the problem in rapid timely basis. In conclusion, new method and new systems(ULTRA #44 Model) are needed urgently to upgrade current HVDC underwater cable survey technique in Korea to minimize the cost and time factors.

  • PDF

HILS 적용을 위한 해상풍력 계통 연계 MMC 모델 개발 (Development of simulation model for offshore wind power generation with MMC for HILS application)

  • 신동철;윤진우;이동명
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.372-373
    • /
    • 2018
  • HVDC(High Voltage Direct Current)전력망은 발전소에서 생산한 교류를 직류로 변환한 이후 송전하여 부하에 가까운 전력변환기를 이용하여 교류로 변환한 후에 사용하는 방식이며, 전압형 HVDC에 MMC(Modular Multilevel Converter)가 널리 사용되고 있다. 본 논문에서는 MMC가 적용된 HVDC를 이용한 해상 풍력 계통 제어 성능을 테스트하기 위해 실시간 시뮬레이션 툴인 RT-Lab에 적용한 모델에 대해 설명하고자 한다.

  • PDF

여자시스템의 파라미터가 터빈-발전기의 비틀림 스트레스에 미치는 영향 분석 (A Study on Effect of Exciter Parameters for the Torsional Stress of Turbine-Generator)

  • 김찬기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권8호
    • /
    • pp.420-426
    • /
    • 2003
  • This paper deals with the effect of exciter parameters on the torsional stress of turbine-generator. The excitation system effects on the AC network stability and the turbine-generator stress. However. it, until now, have not reported that any parameter among exciter parameters is related to the stability and the stress. In order to verify those CIGRE HVDC model was used. Since the AC network with HVDC has the voltage stability problem due to big capacitor, the worst condition to analyze the stress can considered. The EMTDC program is used for the simulation studies.

시뮬레이션 연산시간 단축을 위한 MMC HVDC 시스템의 가속모델 구현 (Implementation of Accelerated Model for Modular Multilevel Converter Based HVDC System to reduce simulation operation time)

  • 이병혁;김시환;김태진;김래영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.389-390
    • /
    • 2014
  • 고압직류송전 (High Voltage Direct Current, HVDC) 시스템의 모듈형 멀티레벨 컨버터 (Modular Multilevel Converter, MMC)는 EMT (Electromagnetic Transients) 시뮬레이션으로 구현 시 많은 연산시간을 요구하므로 시간 단축을 위한 가속설계가 반드시 필요하다. 본 논문에서는 스위칭 함수를 이용한 등가 모델을 이용하여 각 암을 하나의 전압원으로 단순화하였다. 본 가속모델의 유효성을 검증하기 위해 PSCAD/EMTDC에서 제공하는 반도체 스위치를 이용한 모델과 비교하여 시뮬레이션 수행시간을 비교하였다.

  • PDF

양극성 직류 배전망에 적용 가능한 3포트 NPC 기반의 DAB 컨버터에 대한 연구 (A Study of the Three Port NPC based DAB Converter for the Bipolar DC Grid)

  • 윤혁진;김명호;백주원;김주용;김희제
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.336-344
    • /
    • 2017
  • This paper presents the three-port DC-DC converter modeling and controller design procedure, which is part of the solid-state transformer (SST) to interface medium voltage AC grid to bipolar DC distribution network. Due to the high primary side DC link voltage, the proposed converter employs the three-level neutral point clamped (NPC) topology at the primary side and 2-two level half bridge circuits for each DC distribution network. For the proposed converter particular structure, this paper conducts modeling the three winding transformer and the power transfer between each port. A decoupling method is adopted to simplify the power transfer model. The voltage controller design procedure is presented. In addition, the output current sharing controller is employed for current balancing between the parallel-connected secondary output ports. The proposed circuit and controller performance are verified by experimental results using a 30 kW prototype SST system.

Vibration Analysis of Transformer DC bias Caused by HVDC based on EMD Reconstruction

  • Liu, Xingmou;Yang, Yongming;Huang, Yichen
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.781-789
    • /
    • 2018
  • This paper proposes a new approach utilizing empirical mode decomposition (EMD) reconstruction to process vibration signals of a transformer under DC bias caused by high voltage direction transmission (HVDC), which is the potential cause of additional vibration and noise from transformer. Firstly, the Calculation Method is presented and a 3D model of transformer is simulated to analyze transformer deformation characteristic and the result indicate the main vibration is produced along axial direction of three core limbs. Vibration test system has been built and test points on the core and shell of transformer have been measured. Then, the signal reconstruction method for transformer vibration based on EMD is proposed. Through the EMD decomposition, the corrupted noise can be selectively reconstructed by the certain frequency IMFs and better vibration signals of transformer have been obtained. After EMD reconstruction, the vibrations are compared between transformer in normal work and with DC bias. When DC bias occurs, odd harmonics, vibration of core and shell, behave as a nonlinear increase and the even harmonics keep unchanged with DC current. Experiment results are provided to collaborate our theoretical analysis and to illustrate the effectiveness of the proposed EMD method.

Power Loss and Junction Temperature Analysis in the Modular Multilevel Converters for HVDC Transmission Systems

  • Wang, Haitian;Tang, Guangfu;He, Zhiyuan;Cao, Junzheng
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.685-694
    • /
    • 2015
  • The power loss of the controllable switches in modular multilevel converter (MMC) HVDC transmission systems is an important factor, which can determine the design of the operating junction temperatures. Due to the dc current component, the approximate calculation tool provided by the manufacturer of the switches cannot be used for the losses of the switches in the MMC. Based on the enabled probabilities of each SM in an arm, the current analytical models of the switches can be determined. The average and RMS currents can be obtained from the corresponding current analytical model. Then, the conduction losses can be calculated, and the switching losses of the switches can be estimated according to the upper limit of the switching frequency. Finally, the thermal resistance model of the switches can be utilized, and the junction temperatures can be estimated. A comparison between the calculation and PSCAD simulation results shows that the proposed method is effective for estimating the junction temperatures of the switches in the MMC.

동적 등가 회로를 이용한 MMC의 시뮬레이션 모델 개발 (Development of Simulation Model for Modular Multilevel Converters Using A Dynamic Equivalent Circuit)

  • 신동철;이동명
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.17-23
    • /
    • 2020
  • 본 논문에서는 MMC(Modular Multilevel Converter) 시스템 개발시 필요한 등가 회로를 이용한 MMC 시뮬레이션 모델을 제안한다. MMC는 하프 브릿지 혹은 풀 브릿지 형태의 서브 모듈이 직렬로 수십 개에서 수백 개가 연결된 형태의 전력변환기로, 전압형 HVDC(High Voltage Direct Current)와 같은 고압 송전에 가장 적합한 토폴로지로 선택되어 상용화 되어 있다. MMC의 알고리즘 개발을 위해서는 전체 시스템의 시뮬레이션이 필수적이다. 그러나, 수백 혹은 수천 개의 스위칭 소자를 사용하여 MMC의 시뮬레이션 모델의 구성하거나 시뮬레이션을 수행하는 것은 사실상 불가능하다. 따라서 본 논문에서는 전압 레벨 증가 등의 확장성이 용이하고 MMC 변환기의 전압 전류의 동특성을 등가화하여 구현한 시뮬레이션 모델을 제안한다. 스위칭 신호와 암 전류의 방향으로부터 등가 회로의 전압과 전류식을 연산하고, 이를 Matlab/Simulink를 이용하여 등가 모델화한다. 개발된 모델의 타당성을 보이기 위하여 스위칭의 소자를 이용한 5 레벨의 MMC와 본 논문에서 제안하는 등가 모델 MMC의 시뮬레이션의 결과를 보인다. 두 모델의 전류 파형, 전압 파형 등이 일치함을 보임으로써 개발 모델의 타당성을 보이고자 한다.

Estimating Stability of MTDC Systems with Different Control Strategy

  • Nguyen, Thai-Thanh;Son, Ho-Ik;Kim, Hak-Man
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.443-451
    • /
    • 2015
  • The stability of a multi-terminal direct current (MTDC) system is often influenced by its control strategy. To improve the stability of the MTDC system, the control strategy of the MTDC system must be appropriately adopted. This paper deals with estimating stability of a MTDC system based on the line-commutated converter based high voltage direct current (LCC HVDC) system with an inverter with constant extinction angle (CEA) control or a rectifier with constant ignition angle (CIA) control. In order to evaluate effects of two control strategies on stability, a MTDC system is tested on two conditions: initialization and changing DC power transfer. In order to compare the stability effects of the MTDC system according to each control strategy, a mathematical MTDC model is analyzed in frequency domain and time domain. In addition, Bode stability criterion and transient response are carried out to estimate its stability.