• 제목/요약/키워드: HTS tape

검색결과 221건 처리시간 0.024초

Prototype 고온초전도 케이블의 최소 Quench에너지 및 대전류 특성 (A Characteristics of Large Current and Minimum Quench Energy on Prototype High-$T_c$ Superconducting Cable)

  • 김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.236-242
    • /
    • 2000
  • NZP velocities were investigated on Ag sheathed multi filamentary Bi-2223 tape and direction type HTS cable. The critical current($I_c$) of Ag sheathed Bi-2223 tape and direction type HTS cable were 12 A, 63 A at 77 K, 0 T. NZP velocities of tape with two condition of DC and AC were almost same at each temperature. In case of DC, the NZP velocities of numerical analysis and experiment were almost same. NZP velocities of direction type HTS cable were 1.9-2.4 cm/sec. The result shows that the total transport current of spiral type HTS cable in $LN_2$ was 475[A], and transport current passed through almost the outer layer (2-layer). Also, AC transport losses in outer layer of HTS cable was proportion to $I^2$ and higher than losses of inner layer. And in case of $I_p=I_c$, calculated numerical loss density was concentrated on the edge of tape and most of loss density in cable was distributed outer layer more than inner layer.

  • PDF

Critical Current Degradation Analysis in HTS Pancake Coil due to Self Field Effects

  • Nah, Wan-Soo;Joo, Jin-Ho;Yoo, Jai-Moo
    • Progress in Superconductivity
    • /
    • 제1권1호
    • /
    • pp.68-72
    • /
    • 1999
  • Since the discovery of high Tc superconductors, great efforts have been focused to develop high performance HTS magnets for the ultimate applications to power system devices. Magnet designers, however, have had difficulties in the estimation of the maximum operating current of the designed magnet from the tested short sample data, due to the degradation of the critical current density in the magnet. Similar story applies to the HTS electrical bus bar. It has been found that the critical current of Bi-2223 stacked tapes is much less than the total summation of critical currents of each tape, which is mainly attributed to the self magnetic fields. Furthermore, since the critical current degradation of Bi-2223 tape is greater in the normal magnetic field (to the tape surface) than in the parallel one, detailed magnetic field configurations are required to reduce the self field effects. In this paper, we calculate the self field effects of a stacked conductor, defining self field factors of normal and parallel magnetic fields to the tape surface. Finally, the critical current degradations in the HTS magnet are explained by the introduced self field factors of the stacked conductor.

  • PDF

Voltage disturbance detection method for HTS tape using electromagnetically coupled coils

  • Song, Seunghyun;Lee, Jiho;Lee, Woo Seung;Jin, Hongwoo;Hwang, Young Jin;Ko, Tae Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권1호
    • /
    • pp.23-26
    • /
    • 2014
  • This paper represents the detection method of voltage disturbance for high temperature superconducting (HTS) tape using electromagnetically coupled coils. In order to detect the voltage as the superconductor transits from the superconducting state to the normal conduction state, voltage taps are widely used to get the voltage signal. And voltage taps are connected to data acquisition device via signal wires. However this new suggested method can detect the superconducting transition voltage without signal wires between voltage taps and data acquisition device by using electromagnetically coupled coils. This system consists of two electromagnetically coupled coils, the first coil to detect and transmit the voltage of HTS tape and the second coil to pick up the transmitted voltage from the first coil. By using this new suggested method, we can build the 'separated voltage-detection system'. HTS tape and first coil are located under liquid nitrogen vessel and the second coil is located under room temperature condition. In this paper, experiments are performed to verify the feasibility of the proposed method. As the result of the experiment, the separated voltage-detection system using electromagnetically coupled coils can successfully observe superconducting-normal transition of HTS tapes.

고온초전도선의 단선전류 특성분석 (Characteristics of Breakdown Current of HTS Tape)

  • 김재호;심기덕;조전욱;김해준;성기철;김해종;곽동순;배준한;박승엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.200-202
    • /
    • 2004
  • Characteristics of the break down current of HTS tape with different insulator are described. The various insulators are utilized for enduring the high voltage in superconducting power devices. The break down current of HTS tape largely depends on insulators wound round HTS tape. In this research, The break down currents of Bi-2223 tape, which is widely used for superconducting power devices are tested and discussed. It is expected that results from this study can be utilized as basic data in designing superconducting power devices.

  • PDF

Fabrication and Characteristic Tests of a 1 MVA Single Phase HTS Transformer with Concentrically Arranged Windings

  • Kim, S.H.;Kim, W.S.;Choi, K.D.;Joo, H.G.;Hong, G.W.;Han, J.H.;Lee, H.G.;Park, J.H.;Song, H.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권4호
    • /
    • pp.37-40
    • /
    • 2004
  • A 1 MV A single phase high temperature superconducting (HTS) transformer was manufactured and tested. The rated voltages of primary and secondary of the HTS transformer are 22.9 kV and 6.6 kV respectively. BSCCO-2223 HTS tape was used for HTS windings of 1 MV A HTS transformer. In order to reduce AC loss generated in the HTS winding, the type of concentric arrangement winding was adopted to a 1 MV A HTS transformer. Single HTS tape for primary windings and 4 parallel HTS tapes for secondary windings were used considering the each rated current of the HTS transformer. A core of HTS transformer was fabricated as a shell type core made of laminated silicon steel plate. And a GFRP cryostat with a room temperature bore was also manufactured. The characteristic tests of 1 MV A HTS transformer were performed such as no load test, short circuit test and several insulation tests at 65 K using sub-cooled liquid nitrogen. From the results of tests, the validity of design of HTS transformer was ascertained.

Bi-2223/Ag 고온초전도 선재의 기계적 특성 평가 (Evaluation of mechanical properties of Bi-2223/Ag HTS tapes)

  • 하홍수;이동훈;양주생;최정규;윤진국;하동우;오상수;권영길
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.351-354
    • /
    • 2002
  • In most of electrical applications using Bi-2223/Ag HTS tapes, bending and tension stresses are essentially applied to the tape. Therefore, the critical current of the Bi-2223/Ag tape is degraded by increasing the deformation stress, though brittle superconducting filaments are embedded in the reinforced Ag alloy sheath. It is needed to understand bending and tension properties of HTS tapes at room temperature and cryogen to make superconducting magnet, cable and etc. using Bi-2223/Ag HTS tapes. Actually, bending and tension stress applied to the tapes simultaneously, when winding the tapes on former for applications. In this study, the effect of mechanical deformations, bending and tension, on the critical current of Bi-2223/Ag tape was investigated.

  • PDF

고온 초전도 테이프 선재의 퀀치 전파 특성 해석 (Analysis on Quench Propagation Characteristics of HTS Tape)

  • 이지광;김지훈;류경우;차귀수;한송엽
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.35-35
    • /
    • 2000
  • The main issues for the power application of High Tc superconducting tape are lower AC loss and higher stability conditions. HTS tape has large stability margin by high heat capacity of superconductor itself and high temperature margin. But, it can be damaged by continuous heat generation at quench point, because normal zone propagation velocity by generating heat is very low. Here, we analyze the quench propagation characteristics using finite element method for BSCCO-2223 HTS tape.

Assembling and Insulation Test of 1MVA Single Phase HTS Transformer for Power Distribution

  • Kim, S. H.;Kim, W. S.;Kim, J. T.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Lee, S. J.;S. Hahn
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.30-33
    • /
    • 2003
  • 1MVA high temperature superconducting (HTS) transformer with double pancake windings made of BSCCO-2223 HTS tapes was designed and manufactured. And prototype transformer with the same capacity was manufactured also. The each rated voltage of the HTS transformer is 22.9 kV and 6.6 kV. Four parallel BSCCO-2223 HTS tapes were wound in the double pancake windings of low voltage side. In order to distribute the currents equally in each HTS tapes, the three times transposition was performed between the double pancake windings. The windings of prototype transformer were wound using copper tape with the same size as BSCCO-2223 HTS tape. The core of the transformer was designed and manufactured as a shell type core made of laminated silicon steel plate. The several characteristics tests for the prototype transformer were performed in liquid nitrogen and insulation tests were accomplished also.

적층형 Bi-2223 고온초전도 선재 제작에 관한 연구 (A Study on fabrication of stacking type Bi-2223 HTS tapes)

  • 임성우;두호익;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제13권8호
    • /
    • pp.718-723
    • /
    • 2000
  • The critical characteristics of Bi-2223 HTS tapes made by PIT method are influenced by the heat treatment and the mechanical processing. In this study firstly we investigated the influence o rolling reduction rate in mechanical process for improving Jc of HTS tapes. As a result the optimized rolling reduction rate that we obtained was 10%-50% and 30%-30% (1st-2nd). And then we fabricated the stacking type HTS tapes that made of the multi-filamentary tapes with various length(3, 5, 10cm) and with various number of stacking (1, 5, 10 layer). Measuring the critical current and observing the structure of grain we concluded that the stacking type tapes will be able to operate more stably by adding the number of stacking tapes. And we could expect that by minimizing the gap between Ag-sheath of tapes mechanical strength of stacking HTS tapes is enhanced and current in tapes will flow more stably.

  • PDF

외부 자계 인가에 따른 고온초전도 케이블 도체의 ?치 특성 (Influence of external magnetic field on HTS cable conductor)

  • Seong Woo Yim;Si Dole Hwang;Je Myoung Oh;Byung Sung Han
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.284-287
    • /
    • 2003
  • Quench characteristics of HTS cable conductor due to external magnetic field were investigated. Firstly, the influence of critical characteristics of HTS tape on locally applied magnetic field was examined. Secondly, critical current of HTS tapes, which are wound on surface of former, were measured respectively, before the experiment for quench characteristics, Finally, 50mT and 100mT were applied to HTS cable conductor and quench characteristics were investigated through V-I curves. As the results, same as the result of HTS tape, HTS cable conductor showed strong dependence on external magnetic field with direction and magnitude.

  • PDF