• Title/Summary/Keyword: HTS power cable

Search Result 216, Processing Time 0.025 seconds

The Characteristics on Transport Current of Bi-2223 Based Prototype HTS Cable (Bi-2223계 Prototype 고온 초존도 케이블의 전류 통전 특성)

  • 김영석;이병성;곽민환;장현만;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.630-635
    • /
    • 2000
  • Superconducting power cable is one of the most promising energy application of high-T$\sub$2/ superconductor(HTS). Thus we investigated previously the electrical and mechanical characteristics on Bi-2223 Ag sheathed tape. And a prototype HTS cable have been designed constructed and tested. In case of 19-filament type transport losses agree with the results of norris theory(strip). The critical current of HTS cable(1, 19-filament) in LN$_2$was 116[A], 240[A] and degradation coefficient(k) was 0.71, 0.73 respectively. In case of 19-filament cable critical current was decreased because of mechanical strain at pitch. And AC loss of HTS cable(19-filament) was 0.7 [W/m] in 240[A] loading

  • PDF

Pressure Drop Characteristics on HTS Power Cables with LN2 Flow (초전도 케이블 냉각유로에서의 압력강하 특성)

  • Koh Deuk-Yong;Yeom Han-Kil;Lee Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.81-86
    • /
    • 2006
  • High temperature superconducting (HTS) power cable requires forced sub-cooled LN2 flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65 K and 77 K. The HTS power cable needs sufficient cooling to overcome its low temperature heat load. For successful cooling, the hydraulic characteristics of the HTS power cable must be well investigated to design the cables. Especially, the pressure drop in the cable is an important design parameter, because the pressure drop decides the length of the cable, size of the coolant circulation pump and circulation pressure, etc. This paper describes measurement and investigation of the pressure drop of the cooling system. In order to reduce the total pressure drop of the cooling system, the flow rate of liquid nitrogen must be controlled by rotational speed of the circulation pump.

The Standard of test and evaluation for HTS cable system (고온 초전도 케이블 시스템 시험 및 평가 기준(안))

  • Choi, Hyung-Sik;Hwang, Si-Dole;Sohn, Song-Ho;Lim, Ji-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.490-491
    • /
    • 2006
  • Based on the real field test of 22.9kV HTS cable, which is installed in Gochang Power Testing Center located in Chonbuk Province, the standard for the performance test and the quality evaluation have been established. This work will be applied to the development of HTS cable and the purchase process as a practical material. In particular, new items for the cable evaluation such as the measurement of critical current and the heat loss, which was not dealt with in conventional cable, are specified in detail.

  • PDF

Expected Future Market Volume of HTS Equipment in South Korea

  • Yoon, Jae-Young;Lee, Seung-Ryul;Yang, B.;Lee, Seung-Yeup;Won, Young-Jin
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.129-133
    • /
    • 2011
  • This paper shows the entire future market volume of the HTS power industry, one of main smart grid equipment, in the case of the final market penetration ratio reaching 100% in the domestic market (South Korea). In this paper, the market penetration ratio is determined using the judgment method, with the market penetration S-curve induced using the Delphi method and the Product Life Cycle from 2011 (supposed launching year, not realistic physical year), to 2050 (expected final target year). This paper analyzes the HTS market penetration ratio of each stage, apparent innovation, early adapters, and the early/late majority and laggard stage, using the S-curve, thus calculating the total future market volume of HTS equipment in the positive sense. Finally, this paper estimates the quantitative analysis results for the HTS4-items (cable, FCL, transformer, rotation machine) of each year within the domestic market.

Specifications of 22.9kV HTS cables and FCLs considering protection systems in Korean power distribution system (국내계통 보호시스템을 고려한 22.9kV 초전도케이블/한류기 설계사양 제안)

  • Lee, Seung-Ryul;Park, Jong-Young;Yoon, Jae-Young;Lee, Byong-Jun;Yang, Byeong-Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.50-54
    • /
    • 2009
  • In Korea, 22.9kV 50MVA HTS (High Temperature Superconducting) cables and 630A/3kA hybrid SFCLs (Superconducting Fault Current Limiters) have been or are being developed by LS Cable, LS Industrial System, and Korea Electric Power Research Institute. They will be installed at Icheon 154kV Substation for real-power-distribution-system operation in 2010. This paper proposes specification of current limiting resistor/reactor for the SFCL and fault current condition of the HTS cable for applying the superconducting devices to Korean power distribution system, from the viewpoint of power system protection.

Critical Current and AC loss Characteristics with Pitch of HTS tape (HTS tape의 Pitch에 따른 임계전류 및 교류손실 특성)

  • Kim, Hae-Joon;Sim, Ki-Deok;Kim, Jae-Ho;Kim, Seok-Ho;Cho, Jeon-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.265-266
    • /
    • 2006
  • Superconductor is developed for applications in high-power devices such as power-transmission cables, transformers, motor and generators. In such applications, HTS tapes are subjected to various kinds of stress or strain. In the fabrication of the devices, the critical current (Ic) of the high temperature superconductor degrades due to many reasons including the tension applied by bending, twist and thermal contraction. In particular manufactured HTS cable, we need pitch angle controls. This paper is analyzed that Ic characteristics is changed pitch angle of HTS tape. These results will amount the most important basis data in HTS cable.

  • PDF

Electro-magnetic Field Analysis of 2-Layer HTS Power Transmission Cable Core (2층 고온초전도 전력케이블 코어의 전자장 해석)

  • 조전욱;주진홍;김석환;배준한;김해종;김해준;성기철;홍정표
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.269-271
    • /
    • 2003
  • A typical HTS power transmission cable has multi-layer conductor structure to increase the current capacity. The tapes of the innermost layer are wound on a round former, and adjacent tapes of another layer are separated by a thin insulating film. In steady state, the total current flows in the conductor layer, and consequently there is magnetic field between the inner and outer layer. This paper describes a magnetic field amplitude around the conductor layer and the HTS tape by a transport current. Also, this paper will help for future cable conductor prototypes.

  • PDF

Protection system for the application of 22.9 kV HTS cable and FCL to real power grid in Korea (국내 실계통에서의 22.9 kV 초전도케이블/한류기 시범적용을 위한 보호시스템 설계)

  • Lee, Seung-Ryul;Yoon, Jae-Young;Yang, Byong-Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.25-28
    • /
    • 2010
  • 22.9 kV HTS cable and FCL will be installed in 154 kV Icheon substation. It is necessary to design a protection system of the substation for a successful application of the HTS devices. This paper proposes a new power protection system for the application of 22.9 kV HTS cable and SFCL to 154 kV Icheon substation in Korea.

A Study on Insulation Characteristics by Thickness of Laminated Polypropylene Paper for an HTS Transmission Cable (송전급 HTS 케이블용 반합성지의 두께에 따른 절연특성 연구)

  • Choi, Jin-Wook;Choi, Jae-Hyeong;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.35-38
    • /
    • 2009
  • The high temperature superconducting(HTS) power cable, as a key component of the next generation power transmission system, operates cost-effectively because of much less transmission loss. Currently, a world-wide research has been undertaken actively. In this research, we designed insulation thickness and investigated thickness effect of laminated polypropylene paper(LPP) which is insulation material of HTS cable in case of AC and impulse breakdown.

The thermal & hydraulic analysis of the cooling passage for HTS power cable (초전도케이블 냉각유로의 열 및 유동 특성 해석)

  • 홍용주;염한길;김효봉;고득용
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.167-170
    • /
    • 2003
  • The thermal and hydraulic characteristics of the cooling passage for HTS power cable should be carefully investigated to get the highly reliable and economic operation. In this study, the pressure drop and temperature change of the coolant flowing the corrugated passage was estimated using the simple one-dimensional approach, and the temperature distribution in the radial direction was calculated. The results show the dependency of the mass flow rate, thermal conductivities on the cooling performance of the HTS cable.

  • PDF