• 제목/요약/키워드: HR effectiveness

검색결과 112건 처리시간 0.031초

In Vitro Trypanocidal Activity of Macela (Achyrocline satureioides) Extracts against Trypanosoma evansi

  • Baldissera, Matheus D.;Oliveira, Camila B.;Zimmermann, Carine E.P.;Boligon, Aline A.;Athayde, Margareth Linde;Bolzan, Leandro P.;Vaucher, Rodrigo De A.;Santurio, Janio M.;Sagrillo, Michele R.;da Silva, Aleksandro Schafer;Monteiro, Silvia G.
    • Parasites, Hosts and Diseases
    • /
    • 제52권3호
    • /
    • pp.311-315
    • /
    • 2014
  • The aim of this study was to verify the trypanocidal effectiveness of aqueous, methanolic, and ethanolic extracts of Achyrocline satureioides against Trypanosoma evansi in vitro. A. satureioides extracts, known as macela, were used on trypomastigotes at different concentrations (1, 5, 10, 50, 100, 500, and $1,000{\mu}g/ml$) and exposure times (0, 1, 3, 6, and 9 hr). A dose-dependent effect was observed when the 3 extracts were tested. The concentrations of 1, 5, and $10{\mu}g/ml$ were not able to kill trypomastigotes until 3 hr after exposure, and the highest concentrations (500 and $1,000{\mu}g/ml$) were able to kill all trypomastigotes after 1 hr. When the time of exposure was increased up to 9 hr, the concentrations at 50 and $100{\mu}g/ml$ were 100% effective to 3 extracts. The chemical analysis of the extracts revealed the presence of flavonoids, a trypanocidal compound already described. Based on the results, we can conclude that the A. satureioides extracts exhibit trypanocidal effects.

다양한 유리화 동결 방법이 각 시간대별 생쥐 전핵기 배아의 발달에 미치는 영향 (The Effect of Various Vitrification Methods on Developmental Rate of Mouse Pronuclear Embryos at Different Recovery Times)

  • 김지철;서병부;박성백;김재명
    • 한국수정란이식학회지
    • /
    • 제27권1호
    • /
    • pp.63-69
    • /
    • 2012
  • The objective of this study was to investigate the effectiveness of cryopreservation methods for the effect of various vitrification containers, such as EM-grid, OPS, or cryo-loop on the survival and developmental rate of vitrified mouse pronuclear embryos, and mouse cleavage embryo, at 21, 24, 27 and 30 hr after hCG injection. Post-thaw cleavage was similar among treatments, while the developmental rates of mouse blastocyst and hatched blastocyst were higher ($p$ <0.05) in 27 hr and 30 hr than 21 hr. The developmental rate of hatched blastocyst at vitrified cleavage mouse embryos in cryo-loop was significantly higher than vitrified pronuclear embryos of control group as well as EM-grid and OPS ($p$ <0.05). The developmental rate using cryo-loop was higher than EM-grid, but in case of OPS at vitrified cleavage and mouse pronuclear embryos, no significant difference was noticed. These results of our study show that the developmental rates of mouse embryos were unaffected by various vitrification containers, but in case of mouse embryos and hatched blastocysts at late vitrified pronuclear embryos the developmental rates were higher than early vitrified pronuclear embryos. Moreover, the developmental rate of hatched blastocyst at vitrified cleavage mouse embryos was significantly higher than vitrified pronuclear embryos. For better execution of this study, it will be mandatory to include improvement of vitrification containers, cryopreservation methods and conditions, higher survival rate, safe preservation, contamination and embryo loss.

Cluster ing for Analysis of Raman Hyper spectral Dental Data

  • Jung, Sung-Hwan
    • 한국멀티미디어학회논문지
    • /
    • 제16권1호
    • /
    • pp.19-28
    • /
    • 2013
  • In this research, we presented an effective clustering method based on ICA for the analysis of huge Raman hyperspectral dental data. The hyperspectral dataset captured by HR800 micro Raman spectrometer at UMKC-CRISP(University of Missouri-Kansas City Center for Research on Interfacial Structure and Properties), has 569 local points. Each point has 1,005 hyperspectal dentin data. We compared the clustering effectiveness and the clustering time for the case of using all dataset directly and the cases of using the scores after PCA and ICA. As the result of experiment, the cases of using the scores after PCA and ICA showed, not only more detailed internal dentin information in the aspect of medical analysis, but also about 7~19 times much shorter processing times for clustering. ICA based approach also presented better performance than that of PCA, in terms of the detailed internal information of dentin and the clustering time. Therefore, we could confirm the effectiveness of ICA for the analysis of Raman hyperspectral dental data.

플라스틱 온실(溫室)의 열저장(熱貯藏) 시스템 개발(開發)에 관(關)한 연구(硏究)(I) -수막식(水膜式) 열교환(熱交換) 시스템의 개발(開發)- (Development of Thermal Storage System in Plastic Greenhouse (I) -Development of Air-Water Heat Exchange System-)

  • 김용현;고학균;김문기
    • Journal of Biosystems Engineering
    • /
    • 제15권1호
    • /
    • pp.14-22
    • /
    • 1990
  • For efficient use of solar energy in plastic greenhouse, thermal storage system was developed. The system was constructed with the counter-flow type air-water heat exchanger using a thin polyethylene film as a medium of heat exchange parts. Experiments were carried out to investigate the heat exchange rate, optimum water flow rate, overall heat transfer coefficient, and the effectiveness of the counter-flow type air-water heat exchanger with polyethylene film bags. Mathematical model to predict air temperature leaving heat exchanger was developed. The results obtained in the present study are summarized as follows. 1. Heat exchange rate in the counter-flow type air-water heat exchanger with polyethylene film bags was compared to that of polyethylene film. Heat exchange rate was almost identical at air velocity of 0.5m/s on polyethylene film surface. But, heat exchange rate of heat exchanger with polyethylene film bag was $32{\sim}55KJ/m^2$ hr higher than that of polyethylene film at air velocity of 1.0m/s. 2. Considering the formation of uniform water film and the sufficient heat exchange rate of polyethylene film bags, optimum water flow rate in polyethylene film bags was $3.0{\sim}6.0{\ell}/m^2$ min. 3. The overall heat transfer coefficient of polyethylene film bags was found to be $35.0{\sim}130.0KJ/m^2\;hr\;^{\circ}C$ corresponding to the air velocity ranging 0.5 to 4.0 m/s on polyethylene film surface. And the overall heat transfer coefficient showed almost linearly increasing tendency to the variation of air velocity. 4. Mathematical model to predict air temperature leaving the heat exchanger was developed, resulting in a good agreement between the experimental and predicted values. But, the experimental results were a little lower than predicted. 5. Effectiveness of heat exchanger for the experiment was found to be 0.40~0.81 corresponding to the number of transfer units due to the variation of air velocity ranging 0.6 to 1.7 m/s.

  • PDF

Basic Emotions Elicited by Korean Affective Picture System Can be Differentiated by Autonomic Responses

  • Sohn, Jin-Hun;Estate Sokhadze;Lee, Kyug-Hwa;Imgap Yi
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2000년도 춘계 학술대회 및 국제 감성공학 심포지움 논문집 Proceeding of the 2000 Spring Conference of KOSES and International Sensibility Ergonomics Symposium
    • /
    • pp.370-379
    • /
    • 2000
  • Autonomic responses were analyzed in 323 college students exposed to visual stimulation with Korean Affective Picture System (KAPS). Cardiac, vascular and electrodermal variables were recorded during 30 sec of viewing affective pictures. The same slides intended to elicit basic emotions (fear, anger, surprise, disgust, sadness, happiness) were presented to subjects in 2 trials with different experimental context. The first time slides were shown without any instructions (passive viewing), while during the second with instruction to exert efforts to magnify experienced emotion induced by pictures (active viewing). The aim of the study was to differentiate autonomic manifestations of emotions elicited by KAPS stimulation and to identify the role of instructed emotional engagement on physiological response profiles. The obtained results demonstrated reproducibility of responses in both trials with different contexts. Pairwise comparison of physiological responses in emotion conditions revealed the most pronounced differentiation for "ear-anger" and "fear-sadness" pairs (in electrodermal and HR variability parameters). "Fear-surprise" pair was also well differentiable. The typical response profile for all emotions included HR acceleration (except happiness and surprise), an increase of electrodermal activity, and a decrease of pulse volume. Higher cardiovascular and electrodermal reactivity to fear observed in this study, e.g., as compared to data with IAPS as stimuli, can be explained by cultural relevance and higher effectiveness of KAPS as stimuli, can be explained by cultural relevance and higher effectiveness of KAPS in producing certain emotions such as fear in Koreans.

  • PDF

Strategic Bundling of HRM for Organizational Performance: an Empirical Study of Publicly Listed Companies

  • Gautam, Dhruba Kumar
    • 아태비즈니스연구
    • /
    • 제5권2호
    • /
    • pp.51-64
    • /
    • 2014
  • Strategic bundling of Human Resource Management (HRM) practices among themselves works together as an entire HRM system rather than individual HRM practices to achieve organizational objectives. The bundles of HR practices support the effectiveness of one another assuming the effectiveness of any practice depends on other practices in place. It is said that the greater the total degree of bundling among the various components of HRM policies and practices, the more will be the organizational outcomes. Realizing these facts, this study aimed to explore the level of strategic bundling and examined the impact of such bundling on organizational performance to the publicly listed companies of Nepal. This empirical study is based on description and exploratory design for which data collected through the questionnaire based on 5-point liker scale. Total population of the study at the time of data collection are 234 organizations publicly listed in Stock Exchange of Nepal. Questionnaire is distributed to all organizations listed, response received from 105 organizations, as a unit of analysis, which is fairly good response. The study of strategic bundling of HRM practices perhaps the first study in Nepal, found that only 32 percent organizations have followed high bundling HR practices and these high bundling organizations are significantly different with low bundling organizations. Business organizations are trying to practice being close association of HRM policies and practices within them except labor relation with employee participation and business strategies. Supporting to the international literature, strategic bundling of HRM practices among themselves shows statistically significant effects on quality of product or services, labor productivity, financial performance, employee satisfaction, rate of innovation, employee commitment and market share.

  • PDF

LID 효율성 검증기기를 이용한 투수성 블록의 수문순환 효율성 검증에 관한 연구 (A Study on the Effectiveness Verification of Hydrological Cycle of Pervious Pavement using LID Simulator)

  • 김미은;장영수;남칠호;신현석
    • 한국수자원학회논문집
    • /
    • 제48권5호
    • /
    • pp.321-330
    • /
    • 2015
  • 최근 수질 및 수문에 있어 도시화에 미치는 영향을 도시 지역 내 저영향개발 기법을 이용한 저감효율에 관하여 연구가 진행되고 있다. 하지만 저영향개발 기법의 정량적 효율성을 증명할 수 있는 방법이나 기준 설정과 관련한 논문은 전무한 실정이다. 이에 본 연구에서는 수문순환 체계를 재현 및 정량화할 수 있는 강우-유출 시뮬레이터를 개발하였고 실제 투수성 블록에 적용하였다. 이는 일반 블록과의 지표유출 및 중간유출 등 수문순환의 요소에 대하여 정량적으로 산정 및 비교함으로써 기기를 통한 투수성 블록의 효율성 분석을 실시하였다. 본 연구의 결과로 투수성 블록의 경우 강우강도가 크고 지속시간이 길어질수록 지표유출량의 저감효과를 뚜렷이 확인할 수 있었으며, 50 mm/hr의 강우강도로 1시간동안 분사하여도 지표 유출이 전혀 발생하지 않도록 제어할 수 있었다. 그리고 본 연구에서 사용한 기기의 강우검증 과정을 통해 결과의 신뢰성을 높이고 투수성 블록뿐만 아니라 여러 LID 요소 효율성 검증에도 활용할 수 있을 것으로 생각된다. 따라서 본 기기를 활용하여 저영향개발 요소기술별 유출의 저감효과분석을 위한 효율성 검증의 표준화를 정립하는 기초 연구로 활용할 수 있다.

Local Gradient와 Median Filter에 근거한 초해상도 이미지 재구성 (Super Resolution Image Reconstruction based on Local Gradient and Median Filter)

  • ;조상복
    • 대한전자공학회논문지SP
    • /
    • 제47권1호
    • /
    • pp.120-127
    • /
    • 2010
  • 본 논문은 높은 품질 SR 이미지를 획득하기 위해 국소 그라디언트를 기반으로 적응형 보간법을 이용하는 SR 방법을 제공한다. 이 방법에서, 내삽 화소와 인접하는 유효한 화소 사이에 거리는 국소 그라디언트 특징을 이용하여 고려되며, 보간 계수는 LR 이미지의 국소 그라디언트를 고려한다. 픽셀의 국소 그라디언트는 더 작을수록, 그리고 메디안 필터는 보간된 HR 이미지의 블러링과 노이즈를 감소시키기 위해 적용된다. 실험 결과는 특히 이미지의 에지 부분에서, 다른 방법과 비교하여 제안된 방법의 유효성을 보여준다.

부인과 수술 후 Ondansetron과 병용한 Dexamethasone의 오심, 구토 예방과 제통 효과의 비교 (Comparison of Ondansetron with Ondansetron and Dexamethasone in Preventing of PONV in Major Gynecologic Surgery)

  • 이기흥;신효상;전영훈;김시오;홍정길
    • The Korean Journal of Pain
    • /
    • 제14권1호
    • /
    • pp.76-82
    • /
    • 2001
  • Background: Postoperative nausea and vomiting (PONV) are common after general anesthesia and patient controlled analgesia (PCA) using opioids. This study was designed to compare the effectiveness of ondansetron plus dexamethasone versus ondansetron alone in the prevention of PONV in a patient undergoing a PCA. Methods: We studied 166 ASA I, and II in-patients undergoing general anaesthesia for major gynecological surgery. After induction of anesthesia, Group 1 (n = 64) received intravenous (IV) dexamethasone 10 mg and Group 2 (n = 102) received IV saline 2 ml before the surgical incision. Each patient received IV meperidine 50 mg as a loading dose. Meperidine 5 mg/kg, ketorolac 3.6 mg/kg and ondansetron 8 mg diluted in 40 ml solutions were connected to PCA pump for postoperative pain control. Mean arterial blood pressure, heart rate, pain score and symptom-therapy score were checked at 1, 4, 8, 16, 24, and 36 hours after the PCA connection. Results: For Group 1 and Group 2, respectively, the overall incidence of PONV was 12.5% and 23.5%. The pain scores were lower in patients receiving a combination of ondansetron and dexamethasone than those on ondansetron alone at 4 hr (P < 0.05), 8 hr (P < 0.05) and 16 hr (P < 0.05). Conclusions: This study suggests that the combination of ondansetron and dexamethasone is not more effective than ondansetron alone in the prevention of postoperative nausea and vomiting in women having PCA following major gynecological surgery but is more effective for pain control.

  • PDF

백령도, 문산, 군산의 라이다로 측정한 에어로졸 연직분포 -2010년 5월 10~11일 황사를 중심으로- (Aerosol Vertical Distribution Measured by LIDARs in Baengnyeongdo, Munsan, and Gunsan during 10~11 May 2010)

  • 이혜정;김정은;전영신
    • 대기
    • /
    • 제23권4호
    • /
    • pp.519-526
    • /
    • 2013
  • This study aims to analyze the vertical distribution of Asian dust measured by LIDARs at three weather stations in Baengnyeongdo (BND), Munsan (MS), and Gunsan (GS) during 10~11 May 2010, and thereby investigate their effectiveness. Asian dust passed through from central to south-western part of Korea. Although dust particles were detected over the surface in MS and GS, LIDAR data showed that the Asian dust with non-spherical particles was observed in all of the three regions. It seems that the naked-eye observation could not detect dust over the surface of BND due to the temperature inversion below a height of 0.45 km. During the Asian dust events, the duration time of dust presented 9.5 hr (BND), 19.5 hr (MS), and 24.5 hr (GS), respectively with the longest time in GS, whereas dust altitudes ranged from 0.4 to 1.3 km (BND), 0.1 to 2.8 km and 4.1 to 4.2 km (MS), and 0.2 to 2.0 km (GS), respectively, while showing the highest altitude in MS. Aerosol optical thickness (AOT) retrieved by LIDAR and skyradiometer (SR), located close to the LIDAR sites, was compared. MS (LIDAR) and Seoul (SR) attained the AOT of 0.64 and 0.50, and GS (LIDAR) and Gongju (SR) attained the AOT of 0.38 and 0.54, respectively. As SR-derived angstrom exponents (AE) during the time period determined as Asian dust by LIDAR data were 0.17 in Seoul (near MS) and 0.30 in Gongju (near GS), it can be said that the characteristics of dust particles were appeared. During the study period, depolarization ratio could serve as a useful indicator to determine dust aerosol. But, it still seems essential to conduct further investigation with longer period of data to better describe the discrepancy of AOT between LIDARs and SR.