• Title/Summary/Keyword: HPLC method

Search Result 2,077, Processing Time 0.031 seconds

Comparative Analysis of Fritillaria Species by HPLC (Fritillaria속 식물의 HPLC에 의한 비교분석)

  • Kwon, Yong-Soo;Hong, Sung-Sook;Kim, Chang-Min
    • Korean Journal of Pharmacognosy
    • /
    • v.32 no.4 s.127
    • /
    • pp.307-310
    • /
    • 2001
  • In order to investigate alkaloid contents in different Fritillaria species, we analyzed 17 Fritillaria species by HPLC using prederivatization method. The contents of alkaloid $fr.5(11-deoxo-6-oxo-5{\alpha},6-dihydrojervine)$, delavinone and delavine were analyzed and compared.

  • PDF

Microanalysis of Pancuronium Bromide in Urine and Blood by HPLC (HPLC를 이용한 뇨 및 혈액중의 Pancuronium Bromide의 미량분석)

  • 김박광;김양숙;박성배;이종숙;정규혁;김경님
    • YAKHAK HOEJI
    • /
    • v.37 no.1
    • /
    • pp.30-35
    • /
    • 1993
  • HPLC/fluorescence detection method for the analysis of pancuronium bromide in biological fluids was developed. The method depends on the formation of insoluble red complex between pancuronium bromide and rose bengal in aqueous layer. This complex is quantitatively extracted from aqueous layer into chloroform layer. The complex is stable for 1 day in chloroform layer at room temperature. It was possible to analyze pancuronium bromide in the range of 0.05~0.5 $\mu\textrm{g}$/ml without the effect of co-prescribed drugs.

  • PDF

Chiral Purity Test of Bevantolol by Capillaryelectrophoresis and High Performance Liquid Chromatography

  • Long, Pham Hai;Trung, Tran Quoc;Oh, Joung-Won;Kim, Kyeong-Ho
    • Archives of Pharmacal Research
    • /
    • v.29 no.9
    • /
    • pp.808-813
    • /
    • 2006
  • Two methods for the chiral purity determination of bevantolol were developed, namely capillary electrophoresis (CE) using carboxymethyl-${\beta}$-cyclodextrin (CM-${\beta}$-CD) as a chiral selector and high-perfomance liquid chromatography (HPLC) using a chiral stationary phase. In the HPLC method, the separation of bevantolol enantiomers was performed on a Chiralpak AD-H column by isocratic elution with n-hexane-ethanol-diethylamine (10:90:0.1, v/v/v) as mobile phase. In the CE method, bevantolol enantiomers were separated on an uncoated fused silica capillary with 50 mM amonium phosphate dibasic adjusted to a pH 6.5 with phosphoric acid containing 15 mM CM-${\beta}$-CD as running buffer. Validation data such as linearity, recovery, detection limit, and precision of the two methods are presented. The detection limits of S-(-)-bevantolol were 0.1% and 0.05% for CE and HPLC method, respectively and R-(+)-bevantolol were 0.15% and 0.05% for CE and HPLC method, respectively. There was generally good agreement between the HPLC and CE results.

Standardization of Eleutherococcus species and HPLC Method Validation for Quantitative Analysis (정량분석을 통한 Eleutherococcus species의 HPLC 분석법 검증과 표준화)

  • Song, Mi-Kyung;Kim, Mi-Yeon;Kim, Ho-Cheol
    • The Korea Journal of Herbology
    • /
    • v.26 no.1
    • /
    • pp.103-110
    • /
    • 2011
  • Objective : For the standardization and quality control of eleutheroside E in Eleutherococcus species, HPLC analysis was performed and eleutherosdie E content was compared in 23 kinds of Eleutherococcus species collected from Korea and China. Methods : The content of eleutheroside E in stem bark of Eleutherococcus species collected from Korea and China were analyzed by HPLC. 0.5% phosphoric acid and acetonitrile was used as mobile solvent. Validation of HPLC analysis method was confirmed by analyzing specificity, linearity, precision and accuracy following ICH guideline. Results : Content of eleutheroside E was determined to be 1.0-1.6% and 0.5-0.8% in Korean and Chinese E. senticosus, respectively. Content of eleutheroside E in E. sessiliflorus was 0.7-1.1% and 0.2-0.4% respectively in Korean and Chinese origin. All calibration curves showed good linear regression. The method showed good precision and accuracy with intra-day and inter-day variations of 0.880-3.442% (RSD) and 0.606-3.328% (RSD), respectively, and average recovery was of 0.141-1.363% (RSD), for the eleutheroside E analyzed. Conclusion : These results might be used to establish a criterion of eleutheroside E in Eleutherococcus species.

Analytical Method Validation of (-)Epicatechin gallate in Penthorum chinense Pursh Extract using HPLC

  • Kwon, Jin Gwan;Jung, Yeon Woo;Seo, Changon;Hong, Seong Su;Lee, Ji Eun;Shin, Hyun Tak;Jung, Su Young;Choi, Chun Whan;Kim, Jin Kyu
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.04a
    • /
    • pp.100-100
    • /
    • 2019
  • This study attempted to establish a High Performance Liquid Chromatography (HPLC) analysis method for the determination of (-)-epicatechin gallate as a part of the quality control for the development of functional cosmetic materials from Penthorum chinense Pursh extracts. HPLC was performed on a Unison US-C18 column ($4.6{\times}250mm$, $5{\mu}m$) with a gradient elution of 0.05% (v/v) trifluoroacetic acid (TFA) and methyl alcohol at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analyte was detected at 280 nm. The HPLC method was performed in accordance with the International Conference on Harmonization (ICH) guideline (version 4, 2005) of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation were 0.11 and 0.33 mg/mL, respectively. Calibration curves showed good linearity (r2 > 0.9999), and the precision of analysis was satisfied (less than 0.6%). Recoveries of quantified compounds ranged from 99.51 to 101.92%. This result indicates that the established HPLC method is very useful for the determination of marker compound in P. chinense Pursh extracts.

  • PDF

Determination of Retinols in Pharmaceutical Preparations by HPLC (HPLC를 이용한 제제중의 레티놀 유도체 정량)

  • 안문규;문현숙;허문회;김대병;박승희
    • YAKHAK HOEJI
    • /
    • v.45 no.4
    • /
    • pp.352-356
    • /
    • 2001
  • A simple and rapid determination of total retinol from various pharmaceuticals containing retinol derivatives was described. Retinol derivatives were hydrolyzed with alcoholic KOH to alcoholic retinol, which was determined by HPLC. Pretreatments and HPLC conditions depend on the kind of retinols and preparation forms. The total amount of alcoholic retinol could be determined with this method from many pharmaceutical preparation of retinol derivatives. Treating time of KOH, acidic reagents and HPLC conditions were investigated.

  • PDF

Quantification of Arsenic Species in Some Seafood by HPLC-AFS (HPLC-AFS를 이용한 해산물 중 비소 화학종 분리정량)

  • Jeong, Seung-Woo;Lee, Chae-Hyeok;Lee, Jong-Wha;Jang, Bong-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.496-503
    • /
    • 2021
  • Background: Considering the expenses of and difficulties in arsenic speciation by high performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS), alternative measurement methods should be useful, especially for large-scale research and projects. Objectives: A measurement method was developed for arsenic speciation using HPLC-atomic fluorescence spectrometry (HPLC-AFS) as an alternative to HPLC-ICP-MS. Methods: Total arsenic and toxic arsenic species in some seafoods were determined by atomic absorption spectrometry coupled with hydride vapor generation (AAS-HVG) and HPLC-AFS, respectively. Recovery rate of arsenic species in seafood was evaluated by ultra sonication, microwave and enzyme (pepsin) for the optimal extraction method. Results: Limits of detection of HPLC-AFS for As3+, dimethylarsinate (DMA), monomethylarsonate (MMA) and As5+ were 0.39, 0.53, 0.60 and 0.64 ㎍/L, respectively. The average accuracy ranged from 97.5 to 108.7%, and the coefficient of variation was in the range of 1.2~16.7%. As3+, DMA, MMA and As5+ were detected in kelp, the sum of toxic arsenic in kelp was 40.4 mg/kg. As3+, DMA, MMA and As5+ were not detected in shrimp and squid, but total arsenic (iAS and oAS) content in shrimp and squid analyzed by AAS-HVG were 18.1 and 24.7 mg/kg, respectively. Conclusions: HPLC-AFS was recommendable for the quantitative analysis method of arsenic species. As toxic arsenic species are detected in seaweeds, further researches are needed for the contribution degree of seafood in arsenic exposure.

Measurement of δ-Aminolevulinic Acid in Urine by Fluorometric HPLC and Colorimetric Methods (비색법과 HPLC 법에 의한 요중 δ-Aminolevulinic acid의 측정치 비교)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.17-24
    • /
    • 1994
  • The urinary excretion of ${\delta}$-aminolevulinic acid has been widely used as a measure of the biological effect of lead in lead exposed workers. It is usually measured by colorimetric method based on the color reaction of ALA-pyrrole with Ehrlich's reagent. But the results of ${\delta}$-ALA in urine by this method are somewhat artificially higher than expected due to the urinary ALA-like compound such as aminoacetone. On the other hand, the recently developed fluorometric HPLC method is very sensitive and specific for the measuring urinary ALA. In order to compare the data obtained by two methods and to investigate the interrelation between two methods, 117 lead workers with different lead exposure were checked urinary ${\delta}$-ALA, blood lead and other lead exposure related indices. The results obtained are as follows; 1. Urinary excretion of ${\delta}$-ALA by colorimetric method is 2.15 times higher than HPLC method in overall, revealing 2.47 times in workers of blood lead less than $20{\mu}g/dl$, 2.53 times in workers of blood lead $21-40{\mu}g/dl$ and 1.86 times in workers of blood lead over $41{\mu}g/dl$, respectively. 2. While the correlation coefficients of ${\delta}$-ALA measured by colorimetric method with blood lead and blood ZPP was 0.571 and 0.629, those of ${\delta}$-ALA measured by HPLC with blood lead and blood ZPP were 0.6l0 and 0.637. All the correlation coefficients were statistically significant, but there was no statistical difference of correlation coefficients between two methods. 3. The correlation coefficient of urinary excretion of ${\delta}$-ALA between two method was 0.838 without any correction, but it was 0.852 with the correction of specific gravity 1.024. 4. Simple linear regression of ${\delta}$-ALA measured by HPLC method on ${\delta}$-ALA measured by colorimetric method was (ALA-UPH)=-0.245+0.536 (ALA-UCO) without any correction and it was (SP ALA)=-0.525+0.598 (SP ALA-UCO) with the correction of specific gravity 1.024. With above results, it is recommended that the diagnostic criteria of ${\delta}$-ALA for lead poisoning needed to be revised if ${\delta}$-ALA is measured by HPLC rather than colorimetric method.

  • PDF

Comparison of Free Amino Acids in Soybean Paste (Doenjang) by Different Extraction Solvents and Analytical Methods (추출 용매와 분석 기법에 따른 된장의 유리아미노산 비교)

  • Kang, Ok-Ju
    • Korean journal of food and cookery science
    • /
    • v.23 no.1 s.97
    • /
    • pp.150-155
    • /
    • 2007
  • This work was conducted to obtain a rapid, accurate, and precise procedure for free amino acids analysis in Doenjang with HPLC-OPA (high performance liquid chromatography using-phthalaldehyde) and AAA (automatic amino acid analyzer) methods. Different sample extraction procedures among water, 0.1 M perchloric acid, and 0.1% meta-phosphoric acid were also compared. The optimal extraction solvent was 0.1% meta-phosphoric acid for both the HPLC-OPA and AAA methods. Good recoveries for glycine and methionine were observed using the 0.1% meta-phosphoric acid extraction with HPLC-OPA method. Method precisions (% relative standard deviation) for the free amino acids ranged for 1.62% to 8.27%, in which the HPLC-OPA method with water extraction showed the lowest value at 1.62%. Inhibition rates of the free amino acids in Doenjang were greatest with an addition of NaCI at a 1% concentration.

Evaluation on Extraction Conditions and HPLC Analysis Method for Ginsenosides in Panax ginseng (인삼의 추출조건 및 진세노사이드의 HPLC 분석법 평가)

  • Lee, Kyeong Hee;Lee, Dae Young;Lee, Seung Eun;Nam, Ki Yeul;Hwang, Gwang Bo;Kim, Hyung Don;Lee, Jae Won;Choi, Je Hun;Ahn, Young Sup;Kim, Seung Yu;Kim, Geum Soog
    • Korean Journal of Medicinal Crop Science
    • /
    • v.24 no.1
    • /
    • pp.47-54
    • /
    • 2016
  • Background : A new extraction method-heated ultrasonic extraction was qualitatively and quantitatively analyzed for the extraction of major ginsenosides from ginseng extract; this new high-performance liquid chromatography (HPLC) method was compared with the official extraction method of Korean industrial standards and standard for health functional food. Methods and Results : Ginsenoside compounds were analyzed for 35 minutes by the new HPLC analysis method using a Halo$^{(R)}$ RP-Amide column. The new HPLC analysis method was validated by the measurement of intra-day and inter-day precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of each ginsenoside. The correlation coefficients (r2) for the calibration curves of the ginsenoside compounds were over 0.9997 in terms of linearity. The heated ultrasonic extraction method using ultrasonication for 30 minutes at $50^{\circ}C$ yielded higher amount of ginsenosides than the extraction method of the Korean industrial standards owing to the enhancement of extraction efficiency. Conclusions : Compared to the other extraction methods, the heated ultrasonic extraction method yielded a higher amount of ginsenoside Rb1 than Rg1 index compounds for the quality evaluation of ginseng roots.