• Title/Summary/Keyword: HP Filter

Search Result 38, Processing Time 0.027 seconds

Design and Application of a Passive Filter Control System

  • Jeon, Jeong-Chay;Yoo, Jae-Geun;Lee, Sang-Ick
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.3
    • /
    • pp.152-158
    • /
    • 2004
  • The passive filter is economic and efficient in suppressing harmonics but it may cause resonance problems and its performance is constantly dependent on power system impedance or working conditions of loads. This paper presents the DSP (Digital Signal Processor)-based control system, which automatically controls the passive filter in order to solve these problems. The control system can automatically control the passive filter according to working conditions of loads and measured harmonics, reactive power, power factor and so on. Experimental results in the power system using the 100HP DC motor drive are presented in order to verify the performance of the control system.

Repeatability of New Phoria Test Using Color Chart and Color Filter (색 시표와 색 필터를 이용한 새로운 사위검사의 신뢰도)

  • Lee, Sun Haeng;Park, Sun-Young;Kim, Sang-Yoeb;Lee, Dong-Yeol;Kim, Kun-Kyu;Son, Jeong-Sik;Lee, Jae Yoon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.269-274
    • /
    • 2010
  • Purpose: The repeatability of a new Red-Blue phoria chart test (Red-Blue phoria chart; RBP) was appreciated. Methods: Distance (5 m) and near (40 cm) heterophoria was measured in 38 visually normal subjects. Phoria tests using RBP, Howell phoria card (HP), and MIM card (MIM) were done and the repeatability of each phoria test was compared with one another. Results: The mean of horizontal deviations was that RBP was $-0.602{\pm}0.727{\Delta}$, HP was $-0.865{\pm}1.051{\Delta}$, and MIM was $-1.501{\pm}1.346{\Delta}$, at distance, and that RBP was $-2.566{\pm}2.352{\Delta}$, HP was $-2.804{\pm}2.411{\Delta}$, MIM was $-3.838{\pm}2.603{\Delta}$, at near. The repeatability was RBP>MIM>HP in distance tests and MIM>RBP>HP in near tests. Conclusions:RBP test is identified as a reliable phoria test having high repeatability.

The Design of Microstrip Bandpass Filter for Wireless LAN using FDTD Parallel Algorithm (FDTD 병렬화 알고리즘을 이용한 무선랜용 마이크로스트립 대역통과 펄터 설계)

  • 최성열;박경수;고영호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.7
    • /
    • pp.395-400
    • /
    • 2004
  • In this paper, the four-pole elliptic function microstrip filter at 2.4GHz band with fractional bandwidth of 4% is realized using compact miniaturized hairpin resonators. The parallel algorithm FDTD method is used to analyze S-parameter of hairpin resonator filter more accurately, and to calculate the electric coupling and magnetic coupling among the hairpin resonators. Absorbing boundary conditions for mesh termination used Sulivan's simplified PML and the FDTD code was paralleled by MPI for IBM SP2 which had enhanced calculation speed. The experimental measurements are performed by HP8720D vector network analyzer. Measured results on fabricated hairpin type cross coupled bandpass filters show good agreements with theoretic results.

A Study on the Control System of Passive Filter to Reduce Harmonics (고조파 저감을 위한 수동필터의 제어시스템에 관한 연구)

  • 전정채;유재근;이상익
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.124-130
    • /
    • 2004
  • In this paper, we developed DSP(Digital Signal Processor)-based control system to automatically open and close passive filter, which is used to reduce harmonics, according to operating condition of loads. Passive filter control system automatically open and close each branch of filter according to working conditions of loads by sending signals to open and close installation of passive filter after measuring and monitoring voltage, current, harmonics, reactive power, power factor and so on. We verified it's performance by connecting control system with passive filter in the power line using the 100HP D.C motor drive, opening and closing passive filter according to operation condition of motor, and measuring harmonics and reactive power, etc.

Characteristics analysis of Piezoelectric Thin Film SAW filter using Mg-doped GaN/Sapphire Structure (Mg-Doped GaN/Sapphire 구조로 제작된 압전 박막 SAW 필터의 특성분석)

  • 장철영;정은자;정영철;최현철;이정희;이용현
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.759-762
    • /
    • 2003
  • The epitaxially grown Mg-doped GaN thin film was prepared by MOCVD (Metal Organic Chemical Vapor Deposition) for a SAW(Surface Acoustic Wave) filter. Mg-doped GaN thin film had enough properties for a SAW filter which include crystallinity and morphology. The surface morphology and crystalline of the Mg-doped GaN thin films were characterized using AFM and an X-ray rocking curve. The SAW filter, which was fabricated by lift-off process and frequency response, was measured by HP 8753C network analyzer. Center frequency was 96.687 MHz and SAW velocity was 5801 m/s when wavelength(λ) was 60${\mu}{\textrm}{m}$. Insertion loss was over -10 dB, Q was factor over 200, and side lobe attenuation was over 22 dB which was suitable for use as a SAW filter. Electro-mechanical coupling coefficient (k$^2$) was calculated from the measured data. k$^2$ was from 1 % to 1.44 %. The fabricated SAW filter using Mg-doped GaN/sapphire structure has good qualities as a filter and will be used as a SAW filter for operating RF frequency.

  • PDF

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF

Power Factor Correction Circuit For Inverter Air-Conditioner With A Parallel Configuration To Reduce The Material Cost (재료비 절감을 위한 병렬구조를 갖는 인버터 에어컨용 역률제어회로)

  • 정용채;정윤철;권경안
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.122-127
    • /
    • 1999
  • In this paper, the power factor correction circuit using a parallel drive method is proposed so that the high power inverter air-conditioner with 3[hp] compressor motor may obtain the cost down and the improved performance. The adequate design porcedures are presented to reduce the material costs by eliminating the power factor imprving LC filter and derating output capacitor and inverter switches. Using the determined components. the proto-type circuit with 6[kW] power consumption is built and tested to verify the operation of the proposed circuit.

  • PDF

Effective Trapping of Suspended Solids by Biofilter of Intensive Bioproduction Korean System

  • Kim, In-Bae;Jo, Jae-Yoon
    • Journal of Aquaculture
    • /
    • v.21 no.3
    • /
    • pp.181-183
    • /
    • 2008
  • It has been a very hard problem to reduce solids especially suspended solids (SS) in recirculating aquaculture systems. Present description is based on the performance of trapping SS by the biofilter of Intensive Bio-production Korean (IBK) system which is originally developed for nitrification. We found out that this filter has an excellent capability to remove SS in addition to nitrification. Filter element used here is corrugated plastic roofing plates readily available in the market, and cheaper than specially developed and patented products. It is easy to maintain the system, and requires low power consumption to operate for the treatment of a large amount of water. With 2 pumps of 5 hp each, about 500 $m^3$ of water is treated per hour. Flow speed in the filter was 2.6 mm/sec on average. This low flow speed and very large amount of water treated are the reasons for very effective trapping of fine SS. Upon single pass through this filter, 74.5% of total SS and 40% of non-settleable SS were removed. Wherever this filter is employed in recirculating fish farms water keeps high clarity, this having also been empirically ascertained.

Fabrication of a SAW Filter Using a ZnO Thin Film deposited by RF Magnetron Sputtering (RF 마그네트론 스퍼터링법으로 증착된 ZnO 박막 SAW 필터의 제작)

  • Jung, Eun-Ja;Jang, Cheol-Yeong;Jung, Young-Chul;Choi, Hyun-Chul;Lee, Yong-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.141-144
    • /
    • 2003
  • This study proposes ZnO thin film as a piezoelectric material for SAW (surface acoustic wave) filter. The ZnO thin film with thickness $2.6{\mu}m$ was deposited (0001)-oriented sapphire by RF magnetron sputtering technique. IDTs (inter-digital transducers) electrodes were patterned upon SAW filter mask with solid finger structure unapodized using lift-off method on ZnO piezoelectric thin film. SAW propagation velocity was measured with the center frequency by HP 8753C network analyzer. A fabricated ZnO SAW filter exhibited a high propagation velocity of 5433 $^m/s$ and relatively insertion loss of -53.391dB at $\lambda=80{\mu}m$. The side-lobe attenuation of the center frequency was about 17dB. When the wavelength was $80{\mu}m$ $(\lambda/4=20{\mu}m)$, the center frequency was 67.907 MHz. $k^2$ (electromechanical coupling coefficient) was 15.84 %.

  • PDF

Determination of Mineral Nutrient Concentrations in Fish Growing Water and Lettuce Leaf for Hydroball Aquaphonics (하이드로볼 배지경 아쿠아포닉스에서 사육수 및 상추 잎의 무기이온 농도 구명)

  • Lee, Hyunjin;Choi, Kiyoung;Choi, Eunyoung
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.293-305
    • /
    • 2020
  • This experiment was aimed to identify concentrations of mineral nutrients in leaf lettuce (Lactuca sativa) grown on hydroball aquaponics and in the water for growing fish by conducting two experiments. The experiment I (Expt. I) was conducted with 12 fishes (F12) with and without filter, hydroball and plants (H12 (12 fishes, hydroball), FHP12 (12 fishes, filter, hydroball, 6 plants) and HP12 (12 fishes, hydroball, 6 plants)), and the experiment II (Expt. II) was with and without plants (FH15 (15 fishes, filter, hydroball), FHP15 (15 fishes, filter, hydroball, 6 plants)). The pH level in the water of all the treatments was decreased during the growing period, and the pH and EC of the water were lower in all the treatment with plants than those without plants in both Expt. I and Expt. II. When compared with adequate nutrient concentrations for hydroponics, nitrate nitrogen (NO3-N) and phosphorus (P) concentrations in the fish growing water were higher under the FHP15 treatment in Expt. II; however, potassium (K), calcium (Ca), and magnesium (Mg) were only 16, 49, and 82% of hydroponics, representatively, and iron (Fe) was not detected. The fresh weight of lettuce harvested from the FHP15 treatment was 38 g, only a 30% of marketable lettuce yield. The T-N and P contents of the leaf tissue grown under the FHP15 treatment were close to the optimal level; however, the K, Ca, and iron (Fe) contents were less than the optimal with no deficiency symptom.