• Title/Summary/Keyword: HNR

Search Result 44, Processing Time 0.024 seconds

The Study of Correlation between HNR and NNE (HNR과 NNE와의 상관관계 연구)

  • Kim, Kyung-Yuel;Shin, Myung-Sun;An, Jong-Bok;Jeong, Ok-Ran
    • Speech Sciences
    • /
    • v.8 no.3
    • /
    • pp.235-241
    • /
    • 2001
  • The purpose of this study was to determine the correlation between HNR and NNE, EGG HNR and EGG NNE, which are most closely related to noise of voice. Dr. Speech was utilized to obtain acoustic measurements and physiologic measurements, simultaneously. In addition, no normative data of HNR, NNE, EGG HNR, EGG NNE are available in Korean subjects at present. The Pearson correlation coefficient was used to find the correlation between HNR and NNE, EGG HNR and EGG NNE. The results of the study were as follows: First, there was no correlation between HNR and NNE. Second, there was a negative correlation between EGG HNR and EGG NNE. Finally, the mean value of HNR of normal Korean adults was $28.8\pm2.7$ dB, that of NNE -$11.7\pm3.9$ dB, that of EGG HNR $32.9\pm4.6$ dB, and that of EGG NNE $-30.3\pm4.6$ dB.

  • PDF

A Study of Acoustic Measurement in Connected Speech with Dysphonia (음성장애 연속구어의 음향학적 분석)

  • Lee, Myoung-Soon
    • Phonetics and Speech Sciences
    • /
    • v.3 no.4
    • /
    • pp.109-115
    • /
    • 2011
  • The purposes of this study were to identify acoustic parameters of connected speech and to contribute to acoustic analysis of dysphonic voice about patient's natural speech voice as well as sustained phonation of vowels. Acoustic parameters of sentences included LTAS (long-term average spectrum) mean and spectral slope over frequence ranges such as 0-4kHz, 0-6kHz, 0-8kHz, 0-12.5kHz as well as HNR. Acoustic parameters of the vowel 'a' included jitter, RAP, shimmer, NHR, and HNR. Based on 'G' of GRBAS for the severity of dysphonia, two experienced raters judged and classified as four groups including controls, mild, moderate and severe dysphonic group. Connected speech was two sentences extracted from 'stroll' passage. Parameters of the vowel and LTAS mean of the sentences were measured by CSL. The spectral slope of the sentences and HNR of the vowel and the sentences were measured by Praat. Data were statistically analyzed by Spearman correlation and Kruskal-Wallis test using SPSS 12.0. The results of this study are as follows: First, jitter, RAP, shimmer and NHR were significantly different between the groups. Second, for several frequencies, LTAS mean and spectral slope of the sentences were significantly different between the groups. Third, the HNR of the sentences were significantly different between the groups. Forth, there was a presence of correlation between HNR and NHR of the vowel and HNR of the sentences. Accordingly, this study concluded that LTAS, spectral slope, and HNR were predictive parameters of connected speech voice for dysphonic voice.

  • PDF

Diagnosing Vocal Disorders using Cobweb Clustering of the Jitter, Shimmer, and Harmonics-to-Noise Ratio

  • Lee, Keonsoo;Moon, Chanki;Nam, Yunyoung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.11
    • /
    • pp.5541-5554
    • /
    • 2018
  • A voice is one of the most significant non-verbal elements for communication. Disorders in vocal organs, or habitual muscular setting for articulatory cause vocal disorders. Therefore, by analyzing the vocal disorders, it is possible to predicate vocal diseases. In this paper, a method of predicting vocal disorders using the jitter, shimmer, and harmonics-to-noise ratio (HNR) extracted from vocal records is proposed. In order to extract jitter, shimmer, and HNR, one-second's voice signals are recorded in 44.1khz. In an experiment, 151 voice records are collected. The collected data set is clustered using cobweb clustering method. 21 classes with 12 leaves are resulted from the data set. According to the semantics of jitter, shimmer, and HNR, the class whose centroid has lowest jitter and shimmer, and highest HNR becomes the normal vocal group. The risk of vocal disorders can be predicted by measuring the distance and direction between the centroids.

Comparative Study on the Acoustic Characteristics of the Korean Vowel /a/ before and after LMS (후두미세수술 전후 /아/의 음향적 특성 비교)

  • Hwang, Yeon-Sin;Seong, Cheol-Jae
    • MALSORI
    • /
    • no.67
    • /
    • pp.33-60
    • /
    • 2008
  • The aim of this study is to show the differences in acoustic parameters between a pathological voice /a/ caused by vocal polyp and a normal voice /a/ produced after LMS (Laryngeal Microscopic Surgery). It was expected that voices of two kinds could be analyzed effectively in terms of HNR in specific frequency bands than in all frequency bands. For this study, 10 patients' voice were recorded before and after LMS and then were manipulated in terms of four acoustic parameter. It was found out that (a) frequency bands of 500Hz in the range of 1,000Hz to 4,000Hz were very useful to obtain HNR values; (b) frequency bands in the range of 1,248Hz to 5,500Hz on a log scale were very useful to obtain HNR values; (c) F0 dropped after LMS but not significantly; (d) the bandwidth of the second formant (B2) decreased significantly after LMS, while that of the first formant (B1) decreased after LMS but not significantly.

  • PDF

Extraction of Speech Features for Emotion Recognition (감정 인식을 위한 음성 특징 도출)

  • Kwon, Chul-Hong;Song, Seung-Kyu;Kim, Jong-Yeol;Kim, Keun-Ho;Jang, Jun-Su
    • Phonetics and Speech Sciences
    • /
    • v.4 no.2
    • /
    • pp.73-78
    • /
    • 2012
  • Emotion recognition is an important technology in the filed of human-machine interface. To apply speech technology to emotion recognition, this study aims to establish a relationship between emotional groups and their corresponding voice characteristics by investigating various speech features. The speech features related to speech source and vocal tract filter are included. Experimental results show that statistically significant speech parameters for classifying the emotional groups are mainly related to speech sources such as jitter, shimmer, F0 (F0_min, F0_max, F0_mean, F0_std), harmonic parameters (H1, H2, HNR05, HNR15, HNR25, HNR35), and SPI.

Classification of Pathological Voice Signal with Severe Noise Component

  • Li, Ta-O;Jo, Cheol-Woo
    • Speech Sciences
    • /
    • v.10 no.4
    • /
    • pp.107-115
    • /
    • 2003
  • In this paper we tried to classify the pathological voice signal with severe noise component based on two different parameters, the spectral slope and the ratio of energies in the harmonic and noise components (HNR), The spectral slope is obtained by using a curve fitting method and the HNR is computed in cepstrum quefrency domain. Speech data from normal peoples and patients are collected, diagnosed and divided into three different classes (normal, relatively less noisy and severely noisy data), The mean values and the standard deviations of the spectral slope and the HNR are computed and compared with in the three kinds of data to characterize and classify the severely noisy pathological voice signals from others.

  • PDF

The effect of low glycemic index diet on body weight status and blood pressure in overweight adolescent girls: a randomized clinical trial

  • Rouhani, Mohammad Hossein;Kelishadi, Roya;Hashemipour, Mahin;Esmaillzadeh, Ahmad;Azadbakht, Leila
    • Nutrition Research and Practice
    • /
    • v.7 no.5
    • /
    • pp.385-392
    • /
    • 2013
  • Although several studies have assessed the influence of the glycemic index on body weight and blood pressure among adults, limited evidence exists for the pediatric age population. In the current study, we compared the effects of low glycemic index (LGI) diet to the healthy nutritional recommendation (HNR)-based diet on obesity and blood pressure among adolescent girls in pubertal ages. This 10-week parallel randomized clinical trial comprised of 50 overweight or obese and sexually mature girls less than 18 years of age years, who were randomly assigned to LGI or HNR-based diet. Macronutrient distribution was equivalently prescribed in both groups. Blood pressure, weight and waist circumference were measured at baseline and after intervention. Of the 50 participants, 41 subjects (include 82%) completed the study. The GI of the diet in the LGI group was $42.67{\pm}0.067$. A within-group analysis illustrated that in comparison to the baseline values, the body weight and body mass index (not waist circumference and blood pressure) decreased significantly after the intervention in both groups (P = 0.0001). The percent changes of the body weight status, waist circumference and blood pressure were compared between the two groups and the findings did not show any difference between the LGI diet consumers and those in the HNR group. In comparison to the HNR, LGI diet could not change the weight and blood pressure following a 10-week intervention. Further longitudinal studies with a long-term follow up should be conducted in this regard.

A Correlation Study between Acoustic and EGG Parameters in Ordinary College Students and Classical Singing Students (일반학생과 성악도를 대상으로 Dr. Speech의 음향학적 측정치와 EGG 측정치의 상관관계 비교 연구)

  • 안종복;유재연;권도하;정옥란
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.1
    • /
    • pp.28-32
    • /
    • 2002
  • Background and Objective : Classical singing students who have received in systematic voice training appeared distinctive voice characteristics compared to normal people who have not received in systematic voice training. The purpose of this study was to determine the correlation between acoustic parameters and Electroglottography(EGG) parameters in two groups(ordinary college students vs. classical singing students group). Materials and Methods : The 80 ordinary college students and 65 classical singing students participated in this study by utilizing Dr. speech program to obtain acoustic measurements and physiologic measurements simultaneously. The Pearson correlation coefficient was used to find the correlation between acoustic parameters and EGG parameters in two groups(ordinary college students group and classical singing students group). Results : The results of the study were as follows : First, there was no correlation between Jitter and EGG Jitter in ordinary college students group, but there was strong correlation between Jitter and EGG Jitter in classical singing students group. Second, there was no correlation between Shimmer and EGG Shimmer in ordinary college students group, but there was strong correlation between Shimmer and EGG Shimmer in classical singing students group. Third, there was no correlation between Harmonic to Noise Ratio(HNR) and EGG HNR in ordinary college students group, but there was strong correlation between HNR and EGG HNR in classical singing students group. Finally, there was no correlation between Normalized Noise Energy(NNE) and EGG NNE in two groups.

  • PDF

Study on Optimal Welding Processes of Half Nozzle Repair on Small Bore Piping Welds in Reactor Coolant System (원자로냉각재계통 소구경 관통관 용접부 부분노즐교체 예방정비를 위한 최적 용접공정에 관한 연구)

  • Kim, Young Zoo;Jung, Kwang Woon;Choi, Kwang Min;Choi, Dong Chul;Cho, Sang Beum;Cho, Hong Seok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.14 no.1
    • /
    • pp.58-65
    • /
    • 2018
  • The purpose of this study is to develop a Half Nozzle Repair(HNR) process to prevent the leakage from welds on small bore piping in Reactor Coolant System. The Codes & Standards of tempered bead and design requirements of J-Groove welds are reviewed. Automatic machine GTAW welding and machining equipments are developed to perform HNR process. Single pass welding and overlay welding equipments are conducted in order to obtain the optimal temper bead welding process parameters with Alloy 52M filler wire. Coarse grain heat affected zone(CGHAZ) is formed by rapid cooling rate in heat affected zone after welding. Accordingly, a proper temper bead technique is required to reduce CGHAZ in 1-Layer of welds by 2- and 3-Layers. Mock-up tests show that the developed HNR process is possible to meet ASME Code & Standard requirements without any defect.

The Analysis of Electroglottographic Measures from Lx Speech Studio Program in Patients with Vocal Nodules (Lx Speech Studio를 이용한 성대결절환자의 전기성문파형 측정치 분석)

  • 이성은;임성은;최성희;표화영;최재남;최홍식
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.14 no.2
    • /
    • pp.104-109
    • /
    • 2003
  • The purpose of this study is to analyze the EGG measures from Lx Speech Studio program (Laryngograph Ltd, UK) in patient with vocal nodule. Thirty female adults (15 patient with vocal nodule, 15 normal speaker) produced sustained vowel and read the passage. They were grouped into three groups based on Grade (GRBAS) : normal-G0, nodule-Gl, nodule-G2. Estimates of Fx (Hz), Qx(%), Jitter, Shimmer, and HNR were made from a 500msec midportion of vowel. In addition, DFx(Hz), DQx(%), CFx(%) and CAx(%) were obtained from reading the passage. These data were compared among groups. The results were as follow Jitter, Shimmer, HNR were significantly higher in nodule-G2 group than in normal-G0 & patient-Gl group. In nodule-G2 group, CFx and CAx from reading passage were significantly higher. For patients with nodule, asymmetry or irregularity were observed in graphs of QxFx & CFx provided by Quantitative Analysis.

  • PDF