• Title/Summary/Keyword: HMD(Head Mount Display)

Search Result 28, Processing Time 0.017 seconds

Proposal of a Hand Motion and Control Method Matching System for Interaction Optimized for Mixed Reality Control - Focusing on Meta Interface and Augmented Behavior (혼합현실 컨트롤에 최적화된 인터랙션을 위한 손 동작과 컨트롤 방식 Matching체계의 제안 - Augmented Behavior와 Meta Interface를 중심으로)

  • Lee, SaYa;Lee, EunJong
    • Smart Media Journal
    • /
    • v.11 no.9
    • /
    • pp.81-93
    • /
    • 2022
  • In an era where non-face-to-face meetings become common, eXtended Reality(XR) is rapidly developing and filling areas that are not satisfied in online meetings based on existing photos/video method. In particular, general users are also able to easily access and use HMD-type mixed reality devices. However, the basic operations applied in HMD-type in Mixed Reality(MR) with hands as the main input tool do not have a standardized system, and each manufacturer operates in a separate response to each other's hand movements. Therefore, this study considered that a systematic hand motion matching system considering the usability and efficiency of operations performed in mixed reality was necessary, and conducted a study to clarify this. First, the basic operation performed in the MR environment and its attributes were investigated, and at the same time, the structure of the hand and the attributes of the possible hand movements were identified. Based on the identified properties, it is intended to present a system that can intuitively and efficiently match basic operation properties in the MR environment with subtle operation properties according to the structure/context of the hand.

Mixed Reality(MR) Technology Trends and Development Prospect (혼합현실(Mixed Reality) 기술 동향과 발전 전망)

  • Moon, Hyung-Nam;Cho, Hee-in;Han, Youngmi
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.3
    • /
    • pp.21-25
    • /
    • 2017
  • In this paper, we review relevant technologies of Mixed Reality(MR) and show important components of perspective that can overcome technical limitations of the current MR. An MR technology combines real and virtual objects in a real environment, and runs interactive in real time, and is regarded as an emerging technology in a large part of the future of Information Technology(IT). We've grouped the major obstacles limiting the wider use of MR technologies into three themes: technological limitations (i,e., tracking, rendering, authoring, and registration), user interface(UI) limitations(i.e., UI metaphor for MR interaction), and social acceptance issues.

Survey on Mixed Reality R&D (혼합현실 기술 연구개발 동향 및 전망)

  • Lee, Sang-Goog
    • Journal of the Korea Computer Graphics Society
    • /
    • v.13 no.2
    • /
    • pp.1-15
    • /
    • 2007
  • In this paper, we review relevant technologies of MR (Mixed Reality) and show important components of perspective that can overcome technical limitations of the current MR. An MR technology combines real and virtual objects in a real environment, and runs interactive in real time, and is regarded as an emerging technology in a large part of the future of IT (Information Technology). We've grouped the major obstacles limiting the wider use of MR technologies into three themes: technological limitations (i,e., tracking, rendering, authoring, and registration), user interface limitations(i.e. UI metaphor for MR interaction), and social acceptance Issues.

  • PDF

Design of an Anamorphic Aspherical Prism Lens for the Head Mount Display (HMD용 회전 비대칭 비구면 프리즘 렌즈 설계)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.83-88
    • /
    • 2008
  • Purpose: To design an anamorphic aspherical prism lens for the HMD optical system. Methods: First, we get the initial data, needed in design, which are distances between each surface etc., by analyzing user's demended specifications and by drawing geometrically the shape of prism lens by using CAD. Based on these data and using 'ode V' which is an optical design software, we could progress the optimization in which we treat the coefficients of the anamorphic aspherical surface as the principal variables. To reduce the cost in DTM manufacturing, we would optimize the optical system with the transmitting surface, existed in the direction of video device among 3 surfaces of the prism lens, remaining as a plane. Results: we could design one anamorphic aspherical prism lens which has the finite ray aberration of 15 ${\mu}m$, the distortion of 0.5%, and the MTF value of 0.3 over at 36 lp/mm for the video device of 12 mm ${\times}$ 9 mm size. Conclusions: We designed a prism lens used for HMD. This prism lens has the optical capacities of 15 ${\mu}m$ finite ray aberration and 0.5% distortion for the video device of 12 mm ${\times}$ 9 mm size, and become the optical system having the MTF value of 0.3 over at 36 lp/mm.

  • PDF

Virtual Reality for Dental Implant Surgical Education (가상현실을 이용한 치과 임플란트 수술 교육)

  • Moon, Seong-Yong;Choi, Bong-Du;Moon, Young-Lae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.169-174
    • /
    • 2016
  • In this study, we evaluated the virtual reality model for dental implant surgery and discussed about the method to make the surgical environment for virtual reality with practical patient data. The anatomical model for patient face was fabricated by facial and oral scan data based on CT data. The simulation scenario was composed step by step fashion with Unity3D. From incision and sinus bone graft procedure which is needed to this patient model to implant installation and bone graft was included in this scenario. We used the HMD and leap motion for immersiveness and feeling of real operation. Twenty training doctor was attended this simulation study, and surveyed their satisfactory results by questionnaire. Implant surgery education program was showed the possibilities of educational tool for dental students and training doctors. Virtual reality for surgical education with HMD and leap motion had advantages, in terms of cheap prcie, easy access.

A Study on the Exploration of English Learning Design Elements Applying Immersive Virtual Reality (몰입형 가상현실을 적용한 영어학습 설계요소 탐색에 관한 연구)

  • Choi, Dong-Yeon
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.5
    • /
    • pp.209-217
    • /
    • 2022
  • Virtual reality entered a new phase with the introduction of wearable devices represented by Oculus. This study proposes an immersive virtual reality based on Oculus Rift that enables direct immersion in virtual reality from a first-person perspective for English learning. At this point, it is meaningful to provide considerations when designing instruction for language learning through a comprehensive and integrated review of immersive virtual reality. Therefore, the main purpose of this study is to find a way to maximize the application of language education in the immersive virtual world. And for the design elements for English learning through immersive virtual reality, the setting of learning theory, consideration of differences in learning, selection of learning tasks, regulation of teachers' influence, determination of types of applied senses, flexibility of design, and usage environment were suggested. By integrating the results, various discussions and directions for instructional design were presented.

Electromyographic Activities of Lower Leg Muscles During Static Balance Control in Normal Adults (정상성인에서 정적 균형 제어 시 다양한 조건에 따른 하퇴 근육 활성도의 특성)

  • Woo, Young-Keun;Park, Ji-Won;Choi, Jong-Duk;Hwang, Ji-Hye;Kim, Yun-Hee
    • Physical Therapy Korea
    • /
    • v.11 no.2
    • /
    • pp.35-45
    • /
    • 2004
  • The purpose of this study was to investigate the correlation and characteristics between electromyographic (EMG) activities of lower leg muscles and the posturographic assessment of static balance control in normal adults. Twenty-four young, healthy adults(12 males, 12 females) participated in the study. Center of pressure (COP) parameters were obtained using force platform as total path distance, total sway area, X mean frequency and Y mean frequency for 20 seconds in the following conditions: (1) comfortable standing with eyes opened or closed, (2) uncomfortable standing (feet together) with eyes opened or closed, (3) virtual moving surround delivered using Head mount display (HMD) with four different moving patterns. The virtual moving patterns consisted of close-far, superior-inferior tilting (pitch), right-left tilting (roll), and horizontal rotation (yaw) movements. Surface electromyographic activites were recorded on the tibialis anterior, peroneus longus, medial and lateral heads of gastrocnemius muscles under each condition. Correlation between the posturographic measures and EMG activities were evaluated. Total path distance and total sway area of COP were significantly increased during uncomfortable standing. EMG activity of tibialis anterior was significantly more during uncomfortable standing and virtual moving surround stimulation than during comfortable standing. Total path distance and sway area of COP during comfortable standing with closed eyes showed significant positive correlation with the EMG activities of the lateral head of gastrocnemius muscle. Total path distances and total sway area of COP during muscle. Total path distances and total sway area of COP during presentation of virtual moving surround also had significant positive correlations with EMG activities of the lateral head of gastrocnemius muscle under close-far movement.

  • PDF

Construction of Virtual Public Speaking Simulator for Treatment of Social Phobia (대인공포증의 치료를 위한 가상 연설 시뮬레이터의 실험적 제작)

  • 구정훈;장동표;신민보;조항준;안희범;조백환;김인영;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.6
    • /
    • pp.615-621
    • /
    • 2000
  • A social phobia is an anxiety disorder characterized by extreme fear and phobic avoidance of social and performance situations. Medications or cognitive-behavior methods have been mainly used in treating it. These methods have some shortcomings such as being inefficient and difficult to apply to treatment. Lately the virtual rcality technology has been applied to dcal with the anxiety disorders in order to compcnsate for these defects. A virtual environment provides a patient with stimuli which cvokes a phobia. and the patient's exposure to the virtual phobic situation make him be able to overcome it. In this study, we suggested the public speaking simulator based on a personal computer for the treatment of social phobia. The public speaking simulator was composed of a position sensor. head mount display and audio system. And a virtual environment for the treatment was suggested to be a seminar room where 8 avatars are sitting. The virtual environment includes a tracking system the trace a participant's head-movement using a HMD with position sensor and 3D sound is added to the virtual environment so that he might fcel it realistic. We also made avatars' motion and facial expression change in reaction to a participant's speech. The goal of developing public speaking simulator is to apply to treat fear of public speaking efficiently and economically. In a future study. we should get more information about immergence and treatment efficiency by clinical test and apply it to this simulator.

  • PDF