• 제목/요약/키워드: HI 농축

검색결과 16건 처리시간 0.02초

Anolyte와 Catholyte의 비율에 따른 HI 농축 전기투석 셀의 성능변화 (Effect of Catholyte to Anolyte Amount Ratio on the Electrodialysis Cell Performance for HI Concentration)

  • 김창희;조원철;강경수;박주식;배기광
    • 한국수소및신에너지학회논문집
    • /
    • 제21권6호
    • /
    • pp.507-512
    • /
    • 2010
  • The effect of catholyte to anolyte amount ratio on the electrodialysis cell performance for HI concentration was investigated. For this purpose, the electrodialysis cell was assembled with Nafion 117 as PEM membrane and activated carbon fiber cloth as electrodes. The initial amount of catholyte was 310 g and that of anolyte varied from 1 to 3 of amount ratio. The calculated electro motive force (EMF) increased with time and the increment enhanced as the amount ratio of catholyte to anolyte decreased. The mole ratios of HI to $H_2O$ (HI molarity) in catholyte were almost the same and exceeded pseudo-azeotropic composition for all amount ratios after 2 h operation. The HI molarity continuously increased with time for 10 h operation. The mole ratio of $I_2$ to HI decreased in catholyte but increased in anolyte. The increment of mole ratio of $I_2$ to HI in anolyte rose as the amount ratio of catholyte to anolyte decreased. In case of 1:1 amount ratio, the cell operation was stopped for the safety at approximately 6 h operation, since the mole ratio of $I_2$ to HI reached solubility limit. The cell voltage of the electrodialysis cell increased with time and the rate of increase was high at low amount ratio. This suggests that the amount ratio of catholyte to anolyte not only crucially influences the cell voltage, but also cell operation condition.

IS 프로세스의 HI 분해반응공정을 위한 전해 - 전기투석(EED) HI 농축 (HI concentration by EED for the HI decomposition in IS process)

  • 홍성대;김정근;이상호;최상일;배기광;황갑진
    • 한국수소및신에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.212-217
    • /
    • 2006
  • An experimental study on Electro-electrodialysis (EED) for IS (Iodine-Sulfur) process which is well known as hydrogen production system was carried out for the HI concentration from HIx (HI: $H_2O$ : $I_2$ = 1 : 5 : 1) solution. The polymer electrolyte membrane and the activated carbon cloth were adopted as a cation exchange membrane and electrode, respectively. In order to evaluate the temperature effect about HI concentration in fixed molar ratio, three case of temperature were selected to $60^{\circ}C$, $90^{\circ}C$ and $120^{\circ}C$. The electro-osmosis coefficient and transport number of proton have been changed from 1.95 to 1.21 (mol/Faraday) and 0.91 to 0.76, respectively as temperature increase from $60^{\circ}C$ to $120^{\circ}C$. It can be realized that the HI mole fraction in final stage of EED experiments already over the quasi-azeotrope composition.

HI 농축을 위한 전해-전기투석 셀의 스케일-업에 관한 연구 (Study on Scale-up of Electro-Electrodialysis [EED] Cell for HI Concentration)

  • 이상호;홍성대;김정근;황갑진;문일식
    • 한국수소및신에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.458-463
    • /
    • 2007
  • An experimental study on scale-up of Electro-electrodialysis(EED) to increase the efficiency of HI decomposition section in the IS(Iodine-Sulfur) process was carried out. The EED stack extends the effective area of the membrane to 20 times of that formerly used in a single EED unit cell. The experiment was carried out using HIx solution($HI:H_2O:I_2=1:8.4{\sim}9:1.85{\sim}1.9$) at $100^{\circ}C$ and various solution flow rates of 20, 30, 40 and 50 cc/min. The increased HI molality in catholyte after one-pass throughout from the EED stack was 3 mol/kg-$H_2O$, 2.2 mol/kg-$H_2O$, 2 mol/kg-$H_2O$ and 1.37 mol/kg-$H_2O$ at 20, 30, 40 and 50 cc/min, respectively. These values satisfied the target of HI molality(the increase of HI molality: 2 mol/kg-$H_2O$) in the IS process for hydrogen production of 20 L/hr.

열화학적 수소제조 IS 프로세스의 효율향상을 위한 전해-전기투석의 실험적 평가 (Evaluation on the Electro-electrodialysis for hydrogen production by thermochemical water-splitting IS process)

  • 홍성대;김정근;이상호;최상일;배기광;황갑진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.13-16
    • /
    • 2006
  • Electro-electrodialysis (EED) experiments were carried out for the HI concentration from HIx $(HI-H_2O-I_2)$ solution to improve the Hl decomposition reaction in the thermochemical water-splitting is (iodine-Sulfur) process. EED cell is composed of the collector electrode and electrolyte. Nafion 117 which was cation exchange membrane used as an electrolyte, and the activated carbon cloth used as an electrode. The HI concentration experiment was carried out using the HIx solution and molar ratio of the $I_2$ were varied from 1 to 3 mole. The cell voltages were decreased as temperature increase. And, membrane properties such as transport number of proton and electro-osmosis coefficient were decreased as temperature increase

  • PDF

HI 농축에 대한 전기투석 셀의 성능 및 운전한계조건 연구 (A Study on the Performance and Operation Limit of Electrodialysis Cell for HI Concentration)

  • 이병우;정성욱;조원철;강경수;박주식;배기광;김영호;김창희
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.749-758
    • /
    • 2011
  • The present work explores the performance and operation limit of electrodialysis cell for HI concentration in sulfur iodine thermochemical hydrogen production process, For this purpose, the electrodialysis cell was assembled with Nafion 117 as a PEM membrane and two activated carbon papers as the electrodes. HIx solution was prepared with composition of HI: $I_2$: $H_2O$ = 1: 0.5~2.5: 5.2 in molar ratio. The cell and its peripheral apparatus were placed in the specially designed convective oven in order to uniformly maintain the operation temperature. As operation temperature increased, the amount of water transport from anode to cathode increased, thus reducing HI molarity in catholyte. Meanwhile, the current efficiency was constant as about 90 %, irrespective of temperature change. The cell voltage increased with initial $I_2$ mole ratio as well as anolyte to catholyte mole ratio. Moreover the cell voltage overshot took place within 10 h cell operation, which is due to the $I_2$ precipitation inside the cell. From the analysis of $I_2$ mole ratio in the anolyte, it is noted that operation limit (in $I_2$ mole ratio) of the electrodialysis cell, arising from was measured to be 3.2, which is much lower than bulk solubility limit of 4.7.

전자선 가속기에 의해 방사선 처리한 양이온교환막을 이용한 전해-전기투석에 의한 HIx용액으로부터 HI의 농축 (Electro-electrodialysis Using the Radiation-treated Cation Exchange Membrane by Accelerated Electron Radiation to Concentrate HI from HIx Solution)

  • 황갑진;김정근;이상호;최호상
    • 멤브레인
    • /
    • 제17권4호
    • /
    • pp.338-344
    • /
    • 2007
  • HI몰랄리티가 9.5 $mol/kg-H_2O$인 HI의 전해-전기투석을 시판의 양이온교환막(CMB)을 이용하여 요오드의 존재하에 실험을 진행하였다. 수소이온 투과의 선택성을 증가시키기 위해, 막은 전자선 가속기를 이용하여 방사선 처리하였다. 방사선 처리한 막의 막특성(막 저항, 이온교환용량, 함수율)을 측정하였다. 각각의 방사선량에서 처리한 막의 2 $mol/dm^3$의 KCl 용액에서 막저항, 이온교환용량과 함수율은 처리하지 않은 막과 거의 동등의 값을 가졌다. HI몰랄리티가 9.5 $mol/kg-H_2O$인 HI의 전해-전투기투석을 $75^{\circ}C$, 9.6 $A/dm^2$에서 진행하였다. 전자선 가속기에 의해 방사선 처리한 양이온교환막은 처리하지 않은 막과 비교하여 고분자의 가교구조와 함께 수소이온투과의 높은 선택성을 가졌다.

사차 암모늄 염을 함유하는 농축된 콜로이드 액상 에이프런의 연속상에서의 안정성 (Stability of concentrated Colloidal Liquid Aphrons containing a quaternary ammonium salt in the continuous phase)

  • 함형철;홍원희;이철호
    • 청정기술
    • /
    • 제7권4호
    • /
    • pp.291-297
    • /
    • 2001
  • 본 연구는 중금속 추출 공정에 쓰이는 사차 암모늄 염인 Aliquat 336을 포함하는 콜로이드 액상 에이프런 (colloidal liquid aphrons, CLAs)을 지용성 계면활성제와 수용성 계면활성제를 사용하여 제조하였고 연속상에서 농축된 CLAs의 안정성을 표면으로 떠오르는 유기 용매의 양을 시간에 따라 측정하여 평가하였다. 다양한 조건에서 CLAs의 안정성을 비교하기 위해서 반감기가 도입되었다. 전해질의 첨가나 pH의 변화와 같은 연속상의 상태 변화는 CLAs의 파괴(break-up) 속도에 상당히 영향을 미치는데 이 파괴 속도가 급격히 변화하는 임계 응집 농도가 존재한다. pH의 변화에 따른 임계 응집 농도를 측정하였고 이온의 세기, 수용성 계면활성제 Sodium Dodecyl Sulfonate (SDBS)의 농도에 대한 CLAs의 안정성에 대한 영향을 고찰하였다.

  • PDF

고효율 바이오물질 분리 및 농축을 위한 나노필터소자제작 (Fabrication of Nano-filter Device for High Efficient Separation and Concentration of Biomolecules)

  • 허윤석;최봉길;홍원희
    • Korean Chemical Engineering Research
    • /
    • 제50권4호
    • /
    • pp.738-742
    • /
    • 2012
  • 본 연구에서는 알루미나 나노 템플레이트(anodic alumina oxide; AAO)를 이용하여 신속하면서도 효과적으로 나노입자 및 바이오물질을 분리, 농축할 수 있는 나노필터 소자를 개발하였다. 본 연구에서 사용한 나노필터 소자는 유체의 주입 및 흐름이 가능한 미세유체채널(microfluidic channel)을 PDMS에 패터닝하였다. 위아래로 형성된 PDMS 미세유체채널 사이로, 다양한 크기의 나노 다공을 형성하고 있는 AAO 막을 삽입하여 크기에 따른 나노입자 및 바이오 물질을 분리할 수 있었다. 위아래로 PDMS 유체채널과 AAO 분리막을 집적하고, 최종적으로 아크릴레이트 플락스틱(acrylic plastic)으로 전체 소자를 고정하여 나노필터유체소자를 제작하였다. 완성된 나노필터소자를 이용하여 나노입자의 농축효율 및 은나노입자가 뭉쳐져있는 필터존(filtration zone)으로부터 뎅기 바이러스(dengue virus)를 표면증강라만(surface enhanced Raman scattering)분석법에 의해 검출할 수 있었다.

대추 고추장의 품질 특성과 이의 이용성에 관한 연구 (A Study on the Quality Characteristics and Utilization of Jujube Gochujang)

  • 최수근;신경은;이민수;김수희;최은희
    • 한국조리학회지
    • /
    • 제16권5호
    • /
    • pp.264-276
    • /
    • 2010
  • 본 연구에서는 한국의 대표적인 전통발효식품인 고추장에 약리성 재료인 대추를 첨가하여 기능성 고추장으로써 이용가능성을 알아보고자 본 연구를 실시하였으며, 연구 결과는 다음과 같다. 고추장의 수분 함량은 대추 농축액 첨가군은 첨가량이 증가할수록 고추장의 수분 함량이 유의적(p<0.001)으로 높아지는 경향을 보였고 대추 가루 첨가군은 이와 반대되는 결과를 보였다. 색도는 대추 첨가량이 증가할수록 명도와 황색도는 높아 졌고, 적색도는 낮아졌으며, 염도도 낮아지는 경향을 보였다. 점도는 대추 농축액 첨가군은 첨가량 증가 시 점도가 감소하였으며, 대추 가루 첨가군은 이와 반대되는 결과를 보였다. 관능검사 결과 GJC30과 GJP15가 가장 높은 기호도를 나타내 대추 농축액은 30%, 대추 가루는 15% 첨가 시 고추장의 관능적 및 기계적인 품질 특성의 향상이 가능한 가장 적절한 첨가 수준이라고 사료된다. 이상의 연구 결과를 통해 우리나라 특산물인 대추를 고추장에 첨가함으로써 고추장이나 이를 이용한 떡볶이용 고추장 소스에 활용하는 것이 유효할 것으로 사료된다.

  • PDF

효소면역법에 의한 닭 전염성 기관지염 바이러스 항체검사 (Enzyme Linked Immunosorbent Assay for the Detection of Antibody to Avian Infectious Bronchitis Virus)

  • 송현제;최정옥
    • 한국가금학회지
    • /
    • 제18권3호
    • /
    • pp.183-196
    • /
    • 1991
  • 세계적으로 가장 출현빈도가 높은 혈청형인 마사추셋형 IBV를 발육란에서 증식시킨 다음 요막강액을 채취, 바이러스를 농축 정제하여 항원으로 사용하고 야외 IBV감염계군에서 채취한 혈청중 HI반응에 의해 양성 및 음성혈청을 선발, 표준혈청으로 사용하여 ELISA를 시도한 결과 다음과 같은 성적을 얻었다. 1. 정제항원은 ELISA plate의 well당 40ng 단백량으로 coating하였을 때 높은 P/N치를 나타냈고 혈구응집항원은 well당 1.2~2.5 HA unit로 coating하였을 때 정제항원과 유사한 결과를 보였다. 2. 항원의 coating시 온도와 시간은 37$^{\circ}C$, 1시간이나 4$^{\circ}C$에 12~16시간 처리하였을 때 P/N에서 유의성 있는 차이를 보이지 않았으며 항원을 건조시켜 4$^{\circ}C$에 1개월 보관하여도 항원성의 변화를 인정할 수 없었다. 3 제품이 다른 3종류의 plate에서 항원 coating의 차이를 비교한 결과 제품간에 항원 coating의 균일도와 농도에 있어서 뚜렷한 차이가 인정되었다. 4. 음성혈청희석배수 1:50에서도 비특이 반응은 인정되지 않았으며 가경혈청은 1:100희석했을 때 높은 P/N치를 보여서 screen용 희석배수로 적당하였다. 5. Substrate처리한 후 발색 정도는 15분 이후에는 일정하여 30분까지 변화가 없었으며 이때 발색정지제를 처리하였을 때 치리직후부터 4시간까지도 흡광도에 있어서 유의성 있는 차이가 인정되지 않았다. 6. 74개의 혈청에 대해 ELISA에 의한 P/N치와 HI항체가와의 상관관계는 r=0.42였으며 HI가 2$^{6}$이상, P/N치 1.4이상을 기준으로 하였을 때 양성 case의 일치율은 98.7%였다. 1. 백신접종 시험계군에서 ELISA와 HI test에 의한 항체 소장 비교에서는 10주째를 제외하고는 양 test에서 유사한 추이를 보였다.

  • PDF