• Title/Summary/Keyword: HI

Search Result 4,743, Processing Time 0.034 seconds

The Molecular Gas Kinematics of HI Monsters

  • Kim, Dawoon E.;Chung, Aeree;Yun, Min S.;Iono, Daisuke
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.33.2-33.2
    • /
    • 2020
  • Our HI monster sample is a set of local HI-rich galaxies identified by the ALFALFA survey (Arecibo Legacy Fast Survey ALFA) at z<0.08. Intriguingly, they are also found with a relatively large molecular gas reservoir compared to the galaxies with similar stellar mass and color, yet their star formation rate is quite comparable to normal spirals. This makes our HI monsters good candidates of galaxies in the process of gas accretion which may lead to the stellar mass growth. One feasible explanation for their relatively low star formation activity for a given high cool gas fraction is the gas in monsters being too turbulent to form stars as normal spirals. In order to verify this hypothesis, we probe the molecular gas kinematics of 10 HI monsters which we observed using the Atacama Large Millimeter/sub-millimeter Array (ALMA). We utilize the tilted ring model to investigate what fraction of the molecular gas in the sample is regularly and smoothly rotating. In addition, we model the molecular gas disk using the GALMOD package of the Groningen Image Processing System (GIPSY) and compare with the observations to identify the gas which is offset from the 'co-planar differential rotation'. Based on the results, we discuss the possibility of gas accretion in the sample, and the potential origin of non-regularly rotating gas and the inefficient star formation.

  • PDF

Comparative analysis of HiSeq3000 and BGISEQ-500 sequencing platform with shotgun metagenomic sequencing data

  • Animesh Kumar;Espen M. Robertsen;Nils P. Willassen;Juan Fu;Erik Hjerde
    • Genomics & Informatics
    • /
    • v.21 no.4
    • /
    • pp.49.1-49.11
    • /
    • 2023
  • Recent advances in sequencing technologies and platforms have enabled to generate metagenomics sequences using different sequencing platforms. In this study, we analyzed and compared shotgun metagenomic sequences generated by HiSeq3000 and BGISEQ-500 platforms from 12 sediment samples collected across the Norwegian coast. Metagenomics DNA sequences were normalized to an equal number of bases for both platforms and further evaluated by using different taxonomic classifiers, reference databases, and assemblers. Normalized BGISEQ-500 sequences retained more reads and base counts after preprocessing, while a slightly higher fraction of HiSeq3000 sequences were taxonomically classified. Kaiju classified a higher percentage of reads relative to Kraken2 for both platforms, and comparison of reference database for taxonomic classification showed that MAR database outperformed RefSeq. Assembly using MEGAHIT produced longer assemblies and higher total contigs count in majority of HiSeq3000 samples than using metaSPAdes, but the assembly statistics notably improved with unprocessed or normalized reads. Our results indicate that both platforms perform comparably in terms of the percentage of taxonomically classified reads and assembled contig statistics for metagenomics samples. This study provides valuable insights for researchers in selecting an appropriate sequencing platform and bioinformatics pipeline for their metagenomics studies.

Generation of Radially or Azimuthally Polarized Laser Beams in a Yb:YAG Thin-disc Laser

  • Ye Jin Oh;In Chul Park;Eun Kyoung Park;Jiri Muzik;Yuya Koshiba;Pawel Sikocinski;Martin Smrz;Tomas Mocek;Hoon Jeong;Ji Won Kim
    • Current Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.416-420
    • /
    • 2024
  • A high-power Yb:YAG thin-disc laser with radial or azimuthal polarization incorporating an intracavity S-waveplate is reported. Depending on the rotational angle of the S-waveplate placed in the cavity, a Yb:YAG thin-disc laser yields 10.8 W and 10.2 W of continuous-wave outputs with radial and azimuthal polarization for an incident pump power of 131 W, corresponding to slope efficiencies of 22.9% and 23.7%, respectively. The output characteristics for each polarization state were investigated in detail by analyzing the insertion loss and the mode overlap efficiency due to the S-waveplate. Further prospects for power scaling will be discussed.

THE DIFFERENCE OF TEMPERAMENT, GOODNESS OF FIT AND BEHAVIORAL PROBLEMS IN ADHD SUBTYPES OF ADOLESCENT HIGH RISK GROUP (청소년 ADHD 고위험군의 하위유형별 기질, 기질 적합성 및 문제행동의 차이 비교)

  • Park, Hae-Song;Choi, Eun-Ju
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.16 no.1
    • /
    • pp.106-116
    • /
    • 2005
  • Summary : This study was designed to identify the difference in temperament, parent-adolescent's goodness of fit and behavioral problems between early-adolescent high risk group which can be divided into subgroups (ADHD-I and ADHD-HI/C) and normal group. Method : Subjects of this study were students of a Boy's Middle School and their parents. ADHD high risk group was determined by using three rating scales of ADHD behavioral symptoms : 1. Korean-ADHD Rating Scale, 2. Abbreviated Conners Parents Rating Scale, 3. Conners-Wells' Adolescent Self-Report Scale. Final research was based on the subjects including 25 people in ADHD-I high risk group, 70 ADHD-HI/C high risk group, 70 in normal group. Revised Dimensions of Temperament (DOTS-R) was used for students to assess their temperament, while DOTS-R : Ethnology for parents to access environmental demands. Goodness of fit between parent and adolescent was figured out by results of the two scales. Korean Youth Self Report (K-YSR) was used to examine behavioral problems. Results : When it comes to temperament of adolescents, ADHD-HI/C high risk group was found to be associated with higher scores on general activity level. In contextual parent demand to adolescent, ADHD-HI/C parents showed higher level of demands in general activity than other groups, and lower expectation of positive mood than ADHD-I parents. In parent-adolescent's goodness/poorness of fit, the research found out that ADHD-I and ADHD-HI/C had lower level of fit on pesitive/negative mood than normal group and indicated that ADHD behavioral symptoms connected with poorness of fit in emotional relationship between adolescents and their parents. In behavioral problems, ADHD-HI/C high risk group had severe externalizing and internalizing problems distinctly. It had more severe in externalizing problems than ADHD-I, while there were no differences in internalizing problems between the two subgroups. Conclusion The two ADHD subgroups in high risk adolescents had differences on temperamental activity level and on goodness of fit about positive mood. In addition, they had different patterns in externalizing/internalizing problems.

  • PDF

Harmonization of Hemolysis Index in Clinical Chemistry Laboratory and Its Application as a Result Verification Tool (화학검사 결과의 검증을 위한 용혈 지수 일치화 도구 개발)

  • Pyo, Sang Shin;Nam, Hyun Su;Cha, Young Jong;Lee, Seungkwan;Lee, Hae Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.350-358
    • /
    • 2017
  • The hemolysis index (HI) is semi-quantitative marker for hemolysis. Because the characteristics of the HI vary from one commercial platform to another, no standardization or harmonization of the HI is currently available. Specimens (N=40) randomly selected from clinical patients were artificially hemolyzed in vitro. The serum of the specimens was then diluted with a 20 mg/dL difference between 0~300 mg/dL based on serum hemoglobin measured using the XE-2100 hematology automation equipment (Sysmex, Japan). Diluted serum was measured using the Hitachi-7600 biochemical automation equipment (Hitachi, Japan) to differentiate between HI and serum hemoglobin. The data showed linearity between HI and serum hemoglobin and that HI 1 contained approximately 20 mg/dL of serum hemoglobin. To determine the blood rejection threshold, the HI was divided into three groups: HI 0~1, HI 4~6, HI 9~15. After another batch of clinical specimens (N=40) was measured using a Hitachi-7600 (Hitachi, Japan), each specimen was moved forward and backward with the piston of the syringe to induce an artificial in vitro hemolysis, then measured again with a Hitachi-7600 (Hitachi, Japan). The percentage difference between the three groups was analyzed by ANOVA or the Kruskal-Wallis test. In the post-test, there were significant differences between the HI 0~1 and the HI 5~6: Glucose, creatinine, total protein, AST, direct bilirubin, uric acid, phosphorus, triglyceride, LDH, CPK, Magnesium, and potassium levels. Because many clinical tests differed significantly, the threshold for hemolysis could be appropriate for HI 5 (serum hemoglobin 100 mg/dL).

A Hybrid Dust Collector(Hi-Filter) for Reducing Dust Load (먼지부하 저감형 하이브리드 여과집진장치(Hi-filter))

  • 최호경;박석주;임정환;김상도;박현설;박영옥
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.223-226
    • /
    • 2002
  • 본 연구에서는 전기집진 기술과 여과집진 기술의 조합에 의한 먼지입자의 포집성능 상승효과를 최대한 높일 수 있는 먼지부하 저감형 하이브리드 집진장치(Hi-Filter)를 개발하기 위해 실험실 규모의 장치를 이용한 실험을 통하여 장치의 최적 형상을 결정하고 그 성능을 검증하였다.(중략)

  • PDF

Design of the Hi-fi Wireless Microphone System in UHF band (UHF 대역의 Hi-fi 무선마이크 시스템 설계)

  • 정인화;남옥우;김재형
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.172-175
    • /
    • 2000
  • 본 논문에서는 무선마이크용 특정소출력무선기기의 송수신단을 설계하고 제작하여 특성을 측정하였다. 무선마이크용 특정소출력무선기기의 주파수 대역 740.000~752.000MHz를 사용하였고, 점유주락수대폭의 허용치 200kHz, 최대주파수편이 $\pm$75kHz를 만족하도록 설계하였다. PLL Synthesized, 주파수 변조, Dual Conversion 방식을 사용하였으며 Compander Type은 2:1이다. 설계된 무선마이크 시스템의 출력은 10mW이하이고, 50-20,000Hz의 주파수 응답을 가지며 Hi-fi Audio를 전송할 수 있다. 송수신단의 Total Harmonic Distortion 은 1.5% 이하이다.

  • PDF

'Super Hi-Vision'-an ultra-high definition television-and its human factors

  • Sugawara, M.;Masaoka, K.;Emoto, M.;Nojiri, Y.;Okano, F.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.81-85
    • /
    • 2006
  • The ultra-high definition TV system nicknamed "Super Hi-Vision" is a television system with 4000-scanning-line video and 22.2 multichannel sound. NHK has been developing it with the aim of creating a broadcasting system conveying a strong sensation of presence. We believe that it is important to design the system by taking into account human factors such as human visual system characteristics. This paper describes the psychological and physiological experiments on the visual effects of "Super Hi-Vision".

  • PDF

ESD Protection Circuits with Low-Voltage Triggered SCR for RF Applications

  • Kim, San-Hong;Park, Jae-Young;Kim, Taek-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.24-25
    • /
    • 2008
  • An Electrostatic discharge (ESD) protection has been a very important reliability issue in microelectronics, especially for RF (Radio Frequency) integrated circuits (ICs). This paper reviews design and analysis of on-chip ESD (electrostatic discharge) protection circuits for RF applications. Key issues in RF ESD protection, design methods, and RF ESD protection solutions are discussed.

  • PDF

Studies on Epizootiological Survey of Japanese Encephalitis in Swine I. The Survey on HI Antibody and Abortion and Stillbirth of J.E. Virus in Swine (일본뇌염의 역학적 조사연구 I. 돼지에 있어서 일본뇌염의 항체조사와 유사산 피해조사)

  • Cho, K.S.;Kwon, K.M.;Kim, Y.H.
    • Korean Journal of Veterinary Research
    • /
    • v.10 no.2
    • /
    • pp.59-66
    • /
    • 1970
  • Studies were conducted on the survey of HI antibody abortion and stillbirth from J.E. virus in swine for 1968-1969 in Korea HI antibody against J.E. virus showed postive in June or July and reached 80~100 percent of postive in August or September and J.E. virus strains were isolated from the brain material of the aborted piglets.

  • PDF