• 제목/요약/키워드: HFC-134a, CFC-12, COP

검색결과 7건 처리시간 0.026초

HFC-134a 자동차용 공조시스템의 열역학적 사이클 특성에 관한 연구 (A Study of Thermodynamic Cyclic Characteristics of HFC-134a Automotive Air-Conditioner System)

  • 이규현;원종필
    • 한국자동차공학회논문집
    • /
    • 제2권1호
    • /
    • pp.51-64
    • /
    • 1994
  • Analytical study on the thermodynamical cyclic behabiour and characteristics of HFC-l34a refrigerant for automotive air conditionser system for the replacement of existing CFC-12 has been carried out in this paper through development of system performance simulation program, expecially in the view point of system design considerations. The results indicate that HFC-l34a system will give a greater refrigerating capacity than CFC-12 if appropriate engineering measures such as proper codensers, flow controllers, etc., taken for certain operating conditions. The results, however, also show that the operating power for compression process increases over entire temperature range as a result of decreasing volumetric efficiency due to larger specific volume and increased discharging pressure. The present study results indicate that proper selection of condensing and evaporating temperature plus refrigerant control is very important performance factor to have better COP in the HFC-134a system design.

  • PDF

고효율 수퍼히트펌프에 관한 전산 해석 (Computer Simulation of a Super-Heat Pump System)

  • 김학준;정동수;김종보;하경용
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.234-248
    • /
    • 1995
  • A super-heat pump system composed of a suction line heat exchanger, low and high stage economizers, and a screw compressor is simulated to examine the energy performance and design options. CFC12, HCFC22, HFC134a, HCFC22/HCFC142b, HFC32/HFC134a, and HFC125/HFC134a are used as working fluids for comparison. The results indicate that the proposed system charged with appropriate mixtures is up to 33.4% more energy efficient than the normal system with CFC12. The performance of the super-heat pump system charged with mixtures was influenced by such factors as the temperature matching, heat source temperature difference, low stage economizer, and high stage economizer. The fluids with a larger liquid specific heat such as HFC134a would have more benefits when a suction line heat exchanger is installed. 40%HCFC22/60%HCFC142b mixture seems to be a good candidate to replace CFC12. On the other hand, 25%HFC32/75% HFC134a would be a good long term candidate to replace HCFC22.

  • PDF

대체냉매를 이용한 가정용 냉장고의 시스템 특성에 관한 연구 (An investigation on the system characteristics of a refrigerator with alternative refrigerants)

  • 신진규;문춘근;윤정인
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.753-762
    • /
    • 1998
  • A domestic refrigerator is composed of many components such as a compressor, evaporator, capillary tube, and the cabinet which plays a great role on the cycle performance, even if it is not the basic component part in the cycle. Recently, the restriction policy on the energy-saving and environmentally friendly refrigerator is reinforced in our nation as well as developed countries. Therefore, in this paper, cycle simulations and experiments were carried out ito understand the characteristics of the cycle performance using CFC 12, HFC 134a, and HC 600a and to know how changes in UA(overall heat transfer coefficients$\times$ heat transfer area) of evaporator, the position displacement of compressor, and the rpm of fan in the freezing room which has influence on the cycle performance. The result shows that the quantitative values of simulation and experiment are not coincident, but their trend is similar. When HFC 134a and HC 600a were used without the change of design in refrigerator used CFC 12, the performance of system in HC 600a is 30% lower, and the case of HFC 134a is 10% lower than that of CFC 12 on freezing temperature.

  • PDF

CFC-대체냉매와 스크롤압축기를 사용한 냉동시스템 성능해석 (Performance Analysis of Refrigeration System Using the CFC-Alternative and Scroll Compressor)

  • 박희용;박경우
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.366-381
    • /
    • 1995
  • A performance analysis of refrigeration system using the HFC-134a and scroll compressor is performed numerically. The refrigeration system mainly consists of various standard components such as heat exchanger, compressor, and expansion device. The model for heat exchanger performance is based on a tube-by-tube method which is analyzed separately by considering the cross-flow heat transfer with the outdoor air flow and pressure drop. Compressor is used the scroll-type compressor which has many merits such as high efficiency, low noise and vibration, and small in size. Short-tube is included as an expansion device. Vapour and liquid line are also considered for the performance analysis of refrigeration system. Using the modeling of various components of refrigeration system, a performance comparison of CFC-12 and HFC-134a is performed numerically for the various outdoor air temperature and various values of short-tube diameter. As the results of this study, the refrigeration system performance decreases as the outdoor air temperature increases. And the optimum short-tube diameter based on COP is 1.37mm for this system.

  • PDF

남부지역의 태양열이용 열펌프식 온수.난방시스템의 실증연구 분석 (Analysis of demonstration research on solar heat pump system for room and hot water heating in the southern part of South Korea)

  • 선경호;김기선
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.198.1-198.1
    • /
    • 2010
  • 우리나라 남부지방은 대체적으로 태양 일사량이 풍부하여 태양열 시스템의 설치조건으로는 가장 좋은 지역이다. 현재까지 국내에 보급된 태양열 시스템은 외기조건이 불량한 경우에는 비효율적이다. 최근 태양열 온수기는 전국적으로 매우 활발히 보급되고 있고 태양열 온수기에 대한 일반인들의 인식은 그 어느 때보다 높다고 할 수 있다. 태양열이용 열펌프시스템 기술은 소형 온수기에의 적용 뿐 아니라 건물의 난방기술에도 적용되고 있다. 본 연구에서는 태양열 집열기 직접 팽창식 열펌프시스템(이하 '태양열 시스템')의 열성능 효율 향상에 가장 많이 기여하는 팽창장치와 롤본드형 태양열집열기에 대하여 실험하였고 현장 적용가능성을 분석하였다. 또한 태양열 열펌프식 온수 및 난방시스템의 한국의 남부지방에서의 적용가능성은 지난 관련연구결과를 분석하여 비교하여 모색하였다.

  • PDF

냉장고 사이클 특성에 미치는 열손실량의 영향 (Effect of heat Leak on Cycle Characteristics of Refrigerator)

  • 신진규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.871-879
    • /
    • 1998
  • The refrigerator consists of many components such as compressor condenser expansion valve evaporator and the cabinet which filled by urethane foam. In this paper the heat leakage of refriger-ator is measured by the new experiment method which is different from a present method, The devi-ation of the UA(overall heat transfer coefficient times area) between the simulation and experiments is about 7-8%. Using the modeling of various components of refrigeration system a performance analysos of CFC 12 and HFC 134a is performed numerically on the UA. As the results of this study according to increase the heat leakage the refrigeration load and mass flow rate of refrigerant are increased. And the increase of the mass flow rate results in the increase of the condensing and evapo-rating temperature. Therefore according to increase of the heat leakage the COP leads to increase because the increase of refrigeration capacity is larger than the increase if compressor power.

  • PDF

냉장고 특성 시뮬레이션 (Simulation of Refrigerator Characteristics)

  • 문춘근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.181-189
    • /
    • 1998
  • A general steady-state model for simulation on domastic refrigerator has been developed. The system model consists of various standard components such as evaporator compressor condenser capillary tube and cabinet. Cabinet is not system component but influence characteristic on domastic refrigerator. The purpose of this paper is to compare between characteristics of HFC 134a with CFC 12 in the domastic refrigerator and to predict the steady state cycle performance which is various specifications of cycle components under the continuous running conditions. As the results of simulation the coefficient of performance of both condenser and evaporator increases with increasing UA the increasing rate for condenser is greater than for evaporator.

  • PDF