• 제목/요약/키워드: HEMA

검색결과 215건 처리시간 0.023초

상아질을 통한 HEMA의 확산에 인산농도가 미치는 영향 (EFFECT OF PHOSPHORIC ACID CONCENTRATION ON THE DIFFUSION OF HEMA THROUGH DENTIN)

  • 윤미란;이광원;박수정
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.147-155
    • /
    • 1999
  • The purpose of this study was to investigate the effect of phosphoric acid concentration on the movement of 2-hydroxyethylmethacrylate(HEMA) from bonding resin - resin composite combination through dentin in vitro. Freshly extracted human third molar teeth were divided into four groups each of 10 teeth. A closed chamber with 1 ml distilled water was attached to the CEJ of each tooth. An occlusal cavity of 4mm diameter & remaining dentin thickness of 1.0-1.5mm was prepared in each tooth. Dentin was treated with 10% phosphoric acid gel for 15 seconds. 32% phosphoric acid gel for 15 seconds, or with 35% phosphoric acid gel for 15 seconds. A control group not treated with acid gel was also prepared. The cavities were rinsed, dried and then treated with the HEMA-containing All-Bond 2 primer & bonding resin which was light-cured for 10 seconds. The cavities were then restored with Z100 composite resin(shade:A3.5:3M Dent. Prod. USA) & light cured for 30 seconds. Water samples were retrieved from the chambers over a time course (4.32, 14.4, 43.2, 144 & 432 minutes ; 1, 3 & 10 days) and analyzed by high performance liquid chromatography. The results were as follows. 1. HEMA was detected in the pulp chambers of all teeth from 4.32 minutes after resin placement The highest rate of release was in the first sample period (0-4.32 min) & rate of release declined exponentially thereafter. 2. No significant differences were found for mean release rate for HEMA over a time course among the four groups (p>0.05). 3. The diffusion rate was significantly (p<0.05) less for 10% phosphoric acid gel than 32% phosphoric acid gel at the second sample period(4.32-14.4 min). 4. No significant differences were found for cumulative HEMA diffusion among the four groups at 10 days(p>0.05) and mean total(cumulative) release at 10 days for all groups was in the 9 - 16 nmol range. 5. The cumulative release was significantly (p<0.05) less for 10% phosphoric acid gel than 32% phophoric acid gel at the third(14.4-43.2 min) & fourth(43.2-144 min) sample period.

  • PDF

Poly(Dimethylaminoethyl Methacrylate)-Based pH-Responsive Hydrogels Regulate Doxorubicin Release at Acidic Condition

  • Lee, Seung-Hun;You, Jin-Oh
    • 한국응용과학기술학회지
    • /
    • 제32권2호
    • /
    • pp.202-214
    • /
    • 2015
  • Stimuli-responsive biomaterials that alter their function through sensing local molecular cues may enable technological advances in the fields of drug delivery, gene delivery, actuators, biosensors, and tissue engineering. In this research, pH-responsive hydrogel which is comprised of dimethylaminoethyl methacylate (DMAEMA) and 2-hydroxyethyl methacrylate (HEMA) was synthesized for the effective delivery of doxorubicin (Dox) to breast cancer cells. Cancer and tumor tissues show a lower extracellular pH than normal tissues. DMAEMA/HEMA hydrogels showed significant sensitivity by small pH changes and each formulation of hydrogels was examined by scanning electron microscopy, mechanical test, equilibrium mass swelling, controlled Dox release, and cytotoxicity. High swelling ratios and Dox release were obtained at low pH buffer condition, low cross-linker concentration, and high content of DMAEMA. Dox release was accelerated to 67.3% at pH 5.5 for 6-h incubation at $37^{\circ}C$, while it was limited to 13.8% at pH7.4 at the same time and temperature. Cell toxicity results to breast cancer cells indicate that pH-responsive DMAEMA/HEMA hydrogels may be used as an efficient matrix for anti-cancer drug delivery with various transporting manners. Also, pH-responsive DMAEMA/HEMA hydrogels may be useful in therapeutic treatment which is required a triggered release at low pH range such as gene delivery, ischemia, and diabetic ketoacidosis.

Preparation and Physical Properties of Silicone Hydrogel Ophthalmic Lens Containing Hydrophilic Monomer

  • Lee, Min-Jae;Sung, A-Young
    • 대한화학회지
    • /
    • 제60권4호
    • /
    • pp.261-266
    • /
    • 2016
  • The major physical characteristics of macromolecules used in silicone hydrogel ophthalmic lenses include optical transmittance, oxygen permeability, water content, and refractive index. For the preparation of highly functional silicone hydrogel lens materials, two silicone monomers were used in the presence of 2-hydroxyethyl methacrylate (HEMA) and hydroxypropyl methacrylate (HPMA). The samples containing HEMA and HPMA had oxygen transmissibility (Dk) values in the range of 73.38–50.98 × 10-11 (cm2/s) (mLO2/mL×mmHg) and 71.94–42.80 × 10-11 (cm2/s) (mLO2/mL×mmHg), respectively. Furthermore, the water contents of samples containing HEMA and HPMA were in the range of 32.73–34.67% and 31.94–33.74%, respectively, and the refractive indices were in the range of 1.4348–1.4364 and 1.4385–1.4407, respectively. Thus, silicone monomers containing HEMA and HPMA are expected to be useful for fabricating high-oxygen-permeability silicon hydrogel ophthalmic lenses.

Poly(2-hydroxyethylmethacrylate)와 아미노산과의 상호작용에 관한 DSC와 TGA 열분석에 관한 연구(Ⅰ) (DSC and TGA Thermal Analysis for the Interaction between Poly(2-hydroxyethylmethacrylate) and Amino Acids)

  • 김의락;정봉진;정성욱;민경섭;이명재;남원모;박혜정
    • 대한화학회지
    • /
    • 제40권6호
    • /
    • pp.385-393
    • /
    • 1996
  • Poly(2-hydroxyethylmethacrylate, HEMA)는 contact lens 재료물질로 사용되고, 물을 약 45퍼센트 포함하여 수화겔(hydrogel)을 만들 수 있는 고분자이다. Poly(HEMA)와 아미노산(alanine, arginine, methionine, proline, glycine, serine, lysine)과의 상호작용력을 DSC와 TGA 열분석법으로 측정한 결과 lysine, arginine, alanine의 결합성이 큼을 알 수 있었다.

  • PDF

흰쥐의 섬유아세포 L-929를 이용한 새로운 Soft Contact Lens 소재의 생물안전성 검증 (Biosafety of the New Soft Contact Lens Materials in the Fibroblast L-929 Cell Line)

  • 유영현;남주형;김병길;김순복;문익재;김종필;서영배
    • 한국미생물·생명공학회지
    • /
    • 제37권1호
    • /
    • pp.75-79
    • /
    • 2009
  • In this study, we polymerized new materials for soft contact lens using HEMA (2-hydroxyethyl methacrylate) which is the based-monomer of soft contact lens, EGDMA (ethylene glycol dimethacrylate) as cross linkage agent, and the new additives of monoester or di-ester derived from itaconic acid commercially produced by the fermentation of Asp. itaconicus. New polymer materials for soft contact lens were synthesized with the mixture of HEMA and mono- or diester at different ratios and presented to a good water content and oxygen transmissibility (Dk/L) values. In case of polymerization with HEMA and mono-ester (15%), the water content and oxygen transmissibility of contact lens were found to be good values at 57.6% and 28.5 Dk respectively. The mixture of HEMA and mono-ester is more excellent than HEMA/di-ester in the water content and oxygen transmissibility. The toxicity of new contact lens materials were confirmed in the fibroblast L-929 cell line using a agar overlay test and a growth inhibition test with the extract solution of contact lens.

Poly(2-Hydroxyethyl Methacrylate)막을 통한 아미노산의 확산 기구에 관한 연구 (The Study for Diffusion Mechanism of Amino Acids Through Poly(2-Hydroxyethyl Methacrylate) Membrane)

  • 김의락;정봉진;이명재;민경섭
    • 대한화학회지
    • /
    • 제37권1호
    • /
    • pp.10-21
    • /
    • 1993
  • 2-hydroxyethyl methacrylate(HEMA)을 중합한 P(HEMA)막을 통하여 10가지 아미노산들의 확산계수, 분배계수 및 투과도를 용액의 pH 변화하에서 조사 연구하였다. 아미노산의 투과도는 각 아미노산들의 분자형태, 분자크기 및 전하량에 따라 다른 값을 나타냄을 확인하였으며, 특히 용액의 pH에 따라 전하량이 변화하는 각 아미노산은 P(HEMA)막을 통하여 투과시킬 때 모든 아미노산이 중성영역용액에서 가장 많이 투과되고 이때 막은 미세공막으로 작용하며, 염기성영역용액에는 산성영역용액보다 더 많이 투과되고 막은 분배막으로 작용함을 알았다.

  • PDF

Methacrylamidohistidine in Affinity Ligands for Immobilized Metal-ion Affinity Chromatography of Human Serum Albumin

  • Odaba, Mehmet;Garipacan, Bora;Dede, Semir;Denizli, Adil
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제6권6호
    • /
    • pp.402-409
    • /
    • 2001
  • Different bioligands carrying synthetic adsorbents have been reported in the literature for protein separation, We have developed a novel and new approach to obtain high protein ad-sorption capacity utilizing 2-methacrylamidohistidine(MAH) as a bioligand. MAH was synthe-sized by reacting methacrylocholride and histidine, Spherical beads with an average size of 150-200㎛ were obtained by the radical suspension polymerization of MAH and 2-hydrosyethyl-methacrylate(HEMA) conducted in an aqueous dispersion medium. p(HEMA-co-MAH) beads had a specific surface area of 17.6㎡/g . Synthesized MAH monomer was characterized by NMR. p(HEMA-co-MAH) beads were characterized by swelling test, FTIR and elemental analysis. Then Cu(II) ions were incorporated onto the beads and Cu(II) loading was found to be 0.96 mmol/g.These affinity beads with a swelling ration of 65% and containing, 1.6 mmol MAH/g were used in the adsorption/desorption of human serum albumin(HSA) from both aqueous solutions and hu-man serum. The adsorption of HSA onto p(HEM-co-MAH) was low(8.8 mg/g). Cu(II) chelation onto the beads significantly increased the HSA adsorption (56.3 mg/g). The maximum HSA ad-sorption ws observed at pH 8.0 Higher HSA adsorption was observed from human plasma(94.6 mgHSA/g) Adsorption of other serum proteins were obtained as 3.7 mg/g for fibrinogen and 8.5mg/g for γ-globulin. The total protein adsorption was determined as 107.1mg/g. Desorption of HSA was obtained using 0.1 M Tris/HCl buffer containing 0.5 M NaSCN, High desorption rations(up to 98% of the adsorbed HSA) were observed. It was possible to reuse Cu(II) chelated-p(HEMA-co-MAH) beads without significant decreases in the adsorption capacities.

  • PDF

Benzalkonium Chloride가 BPDM/HEMA계 접착제의 상아질 접착에 미치는 영향 (EFFECT OF BENZALKONIUM CHLORIDE ON DENTIN BONDING WITH BPDM/HEMA SYSTEM)

  • 권병균;안식환;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.569-584
    • /
    • 1996
  • The purpose of this study was to elucidate the effect of benzalkonium chloride on tensile bond strength of BPDM/HEMA dentin bonding. One hundred sixty dentin specimens from freshly extracted bovine mandibular incisors were used, and 0, 0.02, 0.1 or 0.5% benzalkonium chloride solution was applied to the dentin specimen with/after phosphoric acid. 32% phosphoric acid was used when the specimens were bonded with One-Step$^{TM}$, a BPDM/HEMA system and 10% was used when bonded with All-Bond$^{(R)}$ 2, a NTG-GMA/BPDM system. Aelitefil$^{TM}$ composite resin was bonded to the pretreated dentin specimen with the use of All-Bond$^{(R)}$ 2 or One-Step$^{TM}$ dentin bonding agent. After the bonded specimens were stored in $37^{\circ}C$ distilled water for 24 hours, tensile bond strength was measured. The fractured dentin specimens were examined under the scanning electron microscope. The results were as follows : Benzalkonium chloride application after acid-treatment resulted in decrease of dentin bond strength of One-Step$^{TM}$, a BPDM/HEMA system (p>0.05). Benzalkonium chloride application did not exert any influence on dentin bond strength of All-Bond$^{(R)}$ 2, a NTG-GMA/BPDM system (p>0.05). There was no relationship between the concentration or application method of benzalkonium chloride and the dentin bond strength of One-Step$^{TM}$ or All-Bon$^{(R)}$ 2 (p<0.05). On SEM examination of the fractured dentin-resin interface, while mixed failure was prominent in dentin bonding with One-Step$^{TM}$, adhesive and mixed failures were seen together in dentin bonding with All-Bond$^{(R)}$ 2 regardless of the concentration and application method of benzalkonium chloride.

  • PDF

장기간 친수성 유지를 위해 오존을 이용하여 HEMA 처리한 PDMS의 표면 개질 (PDMS Surface Modification with HDMA Grafting Using Ozone for Prolonging Hydrophilicity Lifetime)

  • 김상철;장병현;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2096-2098
    • /
    • 2004
  • 본 논문은 마이크로 유체 소자의 소재로서 많이 쓰이고 있는 poly(dimethyl-siloxane) (PDMS)의 친수성 유지를 위한 표면 개질에 대한 연구이다. PDMS는 유연성, 투명성 등의 다양한 장점을 가지고 있으나, 높은 소수성으로 인하여 유체 소자로의 응용에 제한을 갖는다. 기존 연구에서 수행한 산소 플라즈마 후 2-Hydroxyethyl methacrylate (HEMA) 처리에 의한 PDMS의 표면 개질은 친수성 유지 시간에 한계가 있었다. 이에 친수성 유지 시간을 증가시키기 위하여 경화된 PDMS에 두 시간의 오존 처리 후, 6시간 동안 monomethyl ether hydroquinone (MEHQ)가 제거된 HEMA로 표면을 개질한다. 표면 처리된 PDMS의 친수성 특성을 확인하기 위해 접촉각을 측정하였다. 측정 결과, 오존을 이용하였을 때 $60^{\circ}$ 이하의 낮은 접촉각이 900시간 이상 유지됨을 확인하였다.

  • PDF