• 제목/요약/키워드: HEATER

검색결과 1,744건 처리시간 0.037초

파사드 일체형 자연순환 태양열온수기 유동해석 (Flow Analysis of Facade Integrated Solar Water Heater with Natural Circulation)

  • 백남춘;이왕제;임희원;신우철
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.167-172
    • /
    • 2016
  • Purpose: The solar water heater with natural circulation has been used for several decades in the world as it is automatically operated without a pump and controller and is easy to maintain and repair. After the subsidy was offered from 2012, the solar water heater with natural circulation is becoming increasingly popular in Korea. Recently, the development of a wall-integrated solar water heater, which improves the applicability of buildings and prevents the overheating in the summer, is being developed. On the other hand, the design and performance evaluation data of solar water heaters are very inadequate, and analysis of heat and flow is required to develop a new type of solar water heater. Method: Therefore, in this study, we proposed a new simplified system analysis model that reflects heat and pressure loss from the test results of KS B ISO 9806-1 (Solar collector test method), assuming that the collector is a simple pipe system, the validity of which was verified through experiments. Result: As a result, first, the RMSE of the system circulation flow rate and the average temperature of the inlet and outlet of the collector according to the experimental results and the simulation are 0.05563 and 0.88530, respectively, which are very consistent. Secondly, the mass flow rate is increased linearly with the increase of the solar radiation, and the mass flow rate is 0.0104 ~ 0.0180kg/s in the range of $200{\sim}380W/m^2$ of solar irradiance. Compared with the test flow rate 0.0764kg / s of the test collector, it showed a level of less than 20%.

저온유동성시험기를 이용한 2-핀용 센서통합연료히터의 특성연구 (Characteristics Analysis of 2-pin Sensor Composited Fuel Heater using the Low Temperature Fluidity)

  • 조상;윤달환
    • 전기전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.1230-1235
    • /
    • 2019
  • 본 논문은 2-핀 센서통합연료히터를 개발하고, IT기반의 저온유동성 신호분석 장치를 이용하여 성능을 평가한다. 2-핀 센서통합연료히터의 성능평가는 차량과 동일 환경으로 차량 오일의 유량(Oil flow quantity), 히터에 공급되는 전기적 특성을 측정 및 분석한다. 측정된 데이터는 신호분석 임베디드 회로로 전송하고, 원격에서 사용자들이 웹브라우저를 이용하여 연료 필터의 동작 상태 및 성능을 분석하고 평가한다. 실차에 장착한 후 센서통합연료히터를 검증하기 위하여 온도를 가변 할 수 있는 엔진시험 챔버에서 통합연료히터를 구동시킴으로써 주행 효과를 얻도록 하였고, 엔진의 연료필터 입출력 측에 실험 지그와 데이터 수집 장치를 설치하여 극저온 상황에서 연료필터 입출력 측 연료필터의 온도, 오일주입 능력, 유량 데이터 및 엔진시동의 발화점 등을 평가한다. 이처럼 2-핀 센서히터와 연료필터를 통합한 2-핀 센서통합연료히터 부품의 초기 발화시점, 전기적 특성 및 유량의 입출력 압력 등 차량과 유사한 환경에서 부품의 동작을 파악하고 분석함으로써 제품의 신뢰성을 높인다.

석유 팬 히터의 연소실 주변 열전달 특성 (Heat transfer characteristics around a circular combustion chamber of kerosene fan heater)

  • 김장권
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.551-561
    • /
    • 1998
  • This paper was studied to understand the characteristics of heat transfer coefficients and surface temperature distributions around a circular combustion chamber within the heat-intercept duct of kerosene fan heater. The experiment was carried out in the heat-intercept duct of kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of 240 mm * 240 mm * 1200 mm. The purpose of this paper was to obtain the basic data related with normal combustion for new design from conventional kerosene fan heater, and to investigate the effect of surface temperature, local and mean heat transfer coefficients versus flow-rate of convection axial fan according to the variations of heat release conditions from kerosene fan heater during normal combustion. Consequently it was found that (i) the revolution of convection axial fan during combustion had a smaller value than that of non-combustion because of the thermal resistance due to the high temperature in the heat-intercept duct, (ii) the pressure ratio P$_{2}$/P$_{1}$ had a comparatively constant value of 0.844 according to the revolution increase of turbo fan and the heating performance of kerosene fan heater had a range of 1,494 ~ 3,852 kcal/hr, (iii) the local heat transfer coefficient around a circular combustion chamber had a comparatively larger scale in the range of 315 deg. < .theta. < 45 deg. than that in the range of 90 deg. < .theta. < 270 deg. as a result of heat transfer difference between front and back of a circular combustion chamber, and (iv) the mean heat transfer coefficient around a circular combustion chamber increased linearly like a H$_{m}$=95.196Q+104.019 in condition of high heat release according to the increase of flow-rate of axial fan.n.

Operating characteristics of 3RT heat pumps

  • Moon, Chang-Uk;Choi, Kwang-Hwan;Yoon, Jung-In;Jeon, Min-Ju;Heo, Seong-Kwan;Sung, Yo-Han;Park, Sung-Hyeon;Lee, Jin-Kook;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권2호
    • /
    • pp.140-145
    • /
    • 2017
  • Newly designed vapor-injection heat pumps have been proposed and analyzed in the present study. An economizer-type vapor-injection (V-I) system has been employed as the standard system because of its reliability and simple control method. The V-I system has a re-cooler and re-heater for cooling and heating, respectively. Solar panels have been installed in the V-I heat pump as well as in the re-heater in order to enhance heating capacity and performance. R410A has been employed as a working fluid and performance analysis has been conducted under various conditions. Results are summarized as follows: (1) The V-I system with the re-cooler yielded a marginally higher coefficient of performance (COP) than the conventional V-I refrigeration system. (2) By increasing the re-cooler cooling capacity, enhanced system performance as compared to the conventional V-I system was observed. (3) The re-heater negatively affected the system performance; hence, the V-I heat pump with the re-heater yielded a lower COP than that of the conventional V-I heat pump used for heating. (4) Although the solar panels increased the system performance, this increase could not offset performance degradation by the re-heater.

원적외선 히터에서 출화된 화재의 원인분석 (Cause Analysis Ignited at a Far Infrared Radiation Heater)

  • 김동욱;최충석
    • 한국화재소방학회논문지
    • /
    • 제22권2호
    • /
    • pp.91-96
    • /
    • 2008
  • 본 연구에서는 화재사례를 기반으로 원적외선 히터에서 출화된 화재의 원인 분석에 관하여 연구하였다. 전기히터의 화재는 열선에 용융 흔적으로 판단하여 과열 사고로 취급하는 오류를 범하기 쉽다. 이에 대해 히터의 화재 원인 규명에 있어서 객관적인 자료를 확보하기 위한 방법으로 정상 제품과 비교하여 다양한 재현 실험 및 분석기기를 이용하여 화재 원인을 분석하였다. 열선에 부착된 용융 흔적은 다른 금속 물질에 의한 층간 단락의 형태를 보이나 SEM/EDX로 성분분포를 분석한 결과 철-크롬-알루미늄이 혼합된 열선의 성분이외에 다른 금속 물질은 발견되지 않았다. 또한 층간단락 및 과전압에 의한 과열 실험을 수행한 결과 정상보다 높은 발열 상태를 보이나 화재 가능성은 없었다. 본 논문에서는 원적외선 히터에서 발생한 화재의 원인 분석을 토대로 하여 소손된 전열기의 화염 특성 및 물리 화학적 특성을 입체 분석하여 전기재해 원인 분석의 과학화에 기여하고자 한다.