• 제목/요약/키워드: HDRB

검색결과 20건 처리시간 0.028초

Dynamic loading tests and analytical modeling for high-damping rubber bearings

  • Kyeonghoon Park;Taiji Mazda;Yukihide Kajita
    • Earthquakes and Structures
    • /
    • 제25권3호
    • /
    • pp.161-175
    • /
    • 2023
  • High-damping rubber bearings (HDRB) are commonly used as seismic isolation devices to protect civil engineering structures from earthquakes. However, the nonlinear hysteresis characteristics of the HDRB, such as their dependence on material properties and hardening phenomena, make predicting their behavior during earthquakes difficult. This study proposes a hysteretic model that can accurately predicts the behavior of shear deformation considering the nonlinearity when designing the seismic isolation structures using HDR bearings. To model the hysteretic characteristics of the HDR, dynamic loading tests were performed by applying sinusoidal and random waves on scaled-down specimens. The test results show that the nonlinear characteristics of the HDR strongly correlate with the shear strain experienced in the past. Furthermore, when shear deformation occurred above a certain level, the hardening phenomenon, wherein the stiffness increased rapidly, was confirmed. Based on the experimental results, the dynamic characteristics of the HDR, equivalent stiffness, equivalent damping ratio, and strain energy were quantitatively evaluated and analyzed. In this study, an improved bilinear HDR model that can reproduce the dependence on shear deformation and hardening phenomena was developed. Additionally, by proposing an objective parameter-setting procedure based on the experimental results, the model was devised such that similar parameters could be set by anyone. Further, an actual dynamic analysis could be performed by modeling with minimal parameters. The proposed model corresponded with the experimental results and successfully reproduced the mechanical characteristics evaluated from experimental results within an error margin of 10%.

원전기기의 면진을 위한 진동대 실험 I : 고무베어링 (A Shaking Table Test for Equipment Isolation in the NPP (I): Rubber Bearing)

  • 김민규;전영선;최인길
    • 한국지진공학회논문집
    • /
    • 제8권5호통권39호
    • /
    • pp.65-77
    • /
    • 2004
  • 본 연구에서는 원전기기의 내진안전성을 향상시키기 위한 진동대 실험을 수행하였다. 원전 격납건물과 유사한 진동수 특성을 가지는 구조물을 제작하여 실험에 사용하였으며 구조물 내부에 설치된 기기를 모사 하기 위하여 면진장치가 설치된 강체블럭을 층바닥에 설치하였다. 주파수 특성이 상이한 3종류의 지진파를 이용하여 진동대 실험을 수행하였다. 면진장치로는 천연고무베어링(NRB)과 고감쇠고무베어링(HDRB)을 사용하여 고무의 감쇠특성에 따른 면진기기의 효율성을 분석하였다. 또한 입력지진동의 주파수 특성에 따라 적절한 면진장치의 기기면진효과를 평가하였다. 실험결과 적절한 면진장치를 사용함으로써 기기의 지진응답을 크게 줄일 수 있으며 지진에 대한 안전성을 향상키킬 수 있는 것으로 나타났다.

고감쇠 고무받침의 장기 크리프 특성에 대한 실험적 연구 (An Experimental Study of the Long-term Creep characteristic of High Damping Rubber Bearings)

  • 오주;박진영;박건록;김씨동;박성규
    • 한국지진공학회논문집
    • /
    • 제13권1호
    • /
    • pp.53-60
    • /
    • 2009
  • 지진격리 구조물은 하부구조에서 상부구조로 전달되는 지진력의 현저한 감소가 요구되는 경우 고감쇠 고무받침(HDRB)과 같은 지진격리받침을 사용하는 구조물로서 내진설계의 도입 이후부터 많이 설계, 시공되고 있다. 적층고무받침은 지진격리장치에서 가장 중요한 구조부재이다. 적층형 고무받침의 기본 특성은 압축시험, 압축전단시험, 크리프시험 등을 통하여 얻는 것이 일반적이다. 본 연구에서는 축 응력 7.5MPa, 8.37MPa인 지진격리받침(고감쇠 고무받침)을 실물크기로 제작하여 실험실에서 1000시간동안 크리프 시험을 실시하였다. 고감쇠 고무받침과 같은 지진격리받침을 실제 교량환경 상태에서 장기간 압축 크리프 시험한 결과 1000시간 후 최대크리프 변형은 전체 고무두께의 $0.3{\sim}1.92%$로 변형하였다.

Incorporation preference for rubber-steel bearing isolation in retrofitting existing multi storied building

  • Islam, A.B.M. Saiful;Jumaat, Mohd Zamin;Hussain, Raja Rizwan;Hosen, Md. Akter;Huda, Md. Nazmul
    • Computers and Concrete
    • /
    • 제16권4호
    • /
    • pp.503-529
    • /
    • 2015
  • Traditionally, multi-story buildings are designed to provide stiffer structural support to withstand lateral earthquake loading. Introducing flexible elements at the base of a structure and providing sufficient damping is an alternative way to mitigate seismic hazards. These features can be achieved with a device known as an isolator. This paper covers the design of base isolators for multi-story buildings in medium-risk seismicity regions and evaluates the structural responses of such isolators. The well-known tower building for police personnel built in Dhaka, Bangladesh by the Public Works Department (PWD) has been used as a case study to justify the viability of incorporating base isolators. The objective of this research was to establish a simplified model of the building that can be effectively used for dynamic analysis, to evaluate the structural status, and to suggest an alternative option to handle the lateral seismic load. A finite element model was incorporated to understand the structural responses. Rubber-steel bearing (RSB) isolators such as Lead rubber bearing (LRB) and high damping rubber bearing (HDRB) were used in the model to insert an isolator link element in the structural base. The nonlinearities of rubber-steel bearings were considered in detail. Linear static, linear dynamic, and nonlinear dynamic analyses were performed for both fixed-based (FB) and base isolated (BI) buildings considering the earthquake accelerograms, histories, and response spectra of the geological sites. Both the time-domain and frequency-domain approaches were used for dynamic solutions. The results indicated that for existing multi-story buildings, RSB diminishes the muscular amount of structural response compared to conventional non-isolated structures. The device also allows for higher horizontal displacement and greater structural flexibility. The suggested isolation technique is able to mitigate the structural hazard under even strong earthquake vulnerability.

저경도 고감쇠 고무받침의 동특성에 미치는 영향인자 평가 (Evaluation of Factors Influencing the Dynamic Characteristics of Low Hardness High Damping Rubber Bearings)

  • 최세운;임홍준;조현진;박건록;오주;정희영
    • 한국지진공학회논문집
    • /
    • 제12권3호
    • /
    • pp.11-20
    • /
    • 2008
  • 본 연구에서는 저경도 고감쇠 고무받침 시험체의 다양한 특성실험을 통하여 저경도 고감쇠 고무받침의 특성을 파악하였다. 고무받침의 파악하고자 하는 특성은 압축강성, 전단강성, 등가감쇠비, 전단특성의 변형율 의존성, 전단특성의 면압 의존성, 전단특성의 주파수 의존성, 전단특성의 온도 의존성, 극한전단특성 등이다. 특성실험은 ISO 22762-1에 따라 수행하였으며, ISO 2276-3에 따라 평가하였다. 특성실험결과 전단강성은 전단변형율과 온도 의존성이 큰 것으로 나타났고, 등가감쇠비는 면압 의존성이 큰 것으로 나타났다. 전단특성의 주파수 의존성 실험결과 0.1Hz를 기준으로 경향이 나뉘는 것으로 나타났다. 0.1Hz 이상에서는 전단특성의 변화가 적었지만, 0.1Hz 이하에서는 전단강성과 등가감쇠비 모두 급격히 감소하는 것으로 나타났다. 추가적으로 크리프실험과 극한전단특성실험을 수행하였고, 실험결과는 ISO 22762-3의 요구사항을 만족하는 것으로 나타났다.

지진격리 강재 케이블 교량의 다지점 진동대 실험 (Multi-support excitation shaking table test of a base-isolated steel cable-stayed bridge)

  • 김성도;안진희;공영이;최형석;정진환
    • 한국지진공학회논문집
    • /
    • 제19권4호
    • /
    • pp.161-171
    • /
    • 2015
  • A series of tests was conducted for full-scale single-pylon asymmetric cable-stayed bridges using a system of multiple shaking tables. The 2-span bridge length was 28 m, and the pylon height was 10.2 m. 4 different base conditions were considered: the fixed condition, RB (rubber bearings), LRB (lead rubber bearings), and HDRB (high damping rubber bearings). Based on investigation of the seismic response, the accelerations and displacements in the axial direction of the isolated bridge were increased compared to non-isolated case. However, the strain of the pylon was decreased, because the major mode of the structure was changed to translation for the axial direction due to the dynamic mass. The response of the cable bridge could differ from the desired response according to the locations and characteristics of the seismic isolator. Therefore, caution is required in the design and prediction in regard to the location and behavior of the seismic isolator.

Retrofitting of vulnerable RC structures by base isolation technique

  • Islam, A.B.M. Saiful;Jumaat, Mohd Zamin;Ahmmad, Rasel;Darain, Kh. Mahfuz ud
    • Earthquakes and Structures
    • /
    • 제9권3호
    • /
    • pp.603-623
    • /
    • 2015
  • The scale and nature of the recent earthquakes in the world and the related earthquake disaster index coerce the concerned community to become anxious about it. Therefore, it is crucial that seismic lateral load effect will be appropriately considered in structural design. Application of seismic isolation system stands as a consistent alternative against this hazard. The objective of the study is to evaluate the structural and economic feasibility of reinforced concrete (RC) buildings with base isolation located in medium risk seismic region. Linear and nonlinear dynamic analyses as well as linear static analysis under site-specific bi-directional seismic excitation have been carried out for both fixed based (FB) and base isolated (BI) buildings in the present study. The superstructure and base of buildings are modeled in a 3D finite element model by consistent mass approach having six degrees of freedom at each node. The floor slabs are simulated as rigid diaphragms. Lead rubber bearing (LRB) and High damping rubber bearing (HDRB) are used as isolation device. Change of structural behaviors and savings in construction costing are evaluated. The study shows that for low to medium rise buildings, isolators can reduce muscular amount of base shears, base moments and floor accelerations for building at soft to medium stiff soil. Allowable higher horizontal displacement induces structural flexibility. Though incorporating isolator increases the outlay, overall structural cost may be reduced. The application of base isolation system confirms a potential to be used as a viable solution in economic building design.

복합면진장치를 적용한 무정전전원장치의 1축 진동대실험 기반 동적특성 분석 (Dynamic Characteristic of the Seismic Performance of Uninterruptible Power Supply with Combined Isolator Using Shaking Table Test)

  • 이지언;이승재;박원일;최경규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권1호
    • /
    • pp.19-28
    • /
    • 2022
  • 본 연구에서는 전력·통신 설비로 분류되는 무정전전원장치의 내진성능을 향상하기 위하여 고감쇠고무와 와이어 면진장치를 결합한 3가지 유형의 복합면진장치를 개발하였다. 복합면진장치를 적용한 UPS의 동적 특성을 분석하기 위하여 단축 진동대 실험을 수행하였다. 진동대 실험은 국외 진동대 실험 기준인 ICC-ES AC156을 따라 수행하였으며 기준에서 제시하고 있는 요구응답스텍트럼을 기반으로 입력 지진파를 생성하였다. 입력 지진파의 스케일을 50%에서 200%까지 증가시키며 가진하였다. 진동대 실험을 바탕으로 UPS의 손상양상 및 고유진동수, 감쇠비. 동증폭계수, 상대변위 등 동적특성을 비교 및 분석하였다. 3가지 유형의 복합면지장치를 적용함에 따라 UPS의 내진성능이 향상되었으며 이를 통해 개발 면진장치의 성능을 검증하였다.

2층 철골 구조물에 설치된 무정전전원장치의 실규모 진동대 실험연구 (Full-scale Shaking Table Test of Uninterruptible Power Supply Installed in 2-stories Steel Structure)

  • 이지언;박원일;최경규;오상훈;박훈양
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권3호
    • /
    • pp.29-38
    • /
    • 2022
  • 본 연구에서는 실규모의 2층 철골 구조물에 7종의 건축 및 비건축 비구조요소를 설치하여 진동대 실험을 수행하였다. 진동대 실험은 현행 비내진상세와 면진장치를 적용한 실험으로 두 차례 수행되었으며 본 연구에서는 무정전전원장치(UPS)의 내진성능에 대하여 실험 및 분석하였다. 비내진정착상세로는 UPS 하단에 ㄷ형강 다리부가 설치되었고, 면진장치로는 고감쇠고무와 와이어로프로 구성된 개발 복합면진장치가 사용되었다. 지진하중모사를 위하여 ICC-ES AC156 (2010)에 따라 인공지진파를 생성 후, 동일 지진파의 크기를 점증하여 가진하였다. 진동대실험을 통해 복합면진장치의 적용여부에 따른 UPS의 거동 및 동적 특성(응답가속도, 응답변위, 동증폭계수, 고유진동수, 감쇠비)을 비교 및 분석하였다. 실험결과, 복합면진장치를 적용함에 따라 UPS의 고유진동수가 감소하여 응답가속도 및 증폭계수가 크게 감소하는 것으로 확인되었다.

CT 영상 및 몬테칼로 계산에 기반한 근접 방사선치료계획의 선량분포 평가 방법 연구 (Dose Verification Study of Brachytherapy Plans Using Monte Carlo Methods and CT Images)

  • 정광호;이미연;강세권;배훈식;박소아;김경주;황태진;오도훈
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.253-260
    • /
    • 2010
  • 대다수의 근접치료용 방사선치료계획장치는 AAPM TG-43의 계산식에 기반을 둔 선량계산 알고리듬을 적용하고 있으나 이는 조직의 비균질성을 적절히 고려하지 못한다. 본 연구에서는 몬테칼로 방법을 이용하여 강내고선량근접치료계획을 검증하는 체계를 구축하고자 하였으며, 특히 환자의 CT 영상을 이용하여 물질정보로 변환한 후 직접 몬테칼로 계산을 수행하는 방법의 타당성에 초점을 맞추었다. 판형 팬텀 및 자궁경부암 환자의 CT 영상을 Plato (Nucletron, Netherlands) 치료계획장치를 이용하여 근접치료계획을 수행한 후 여기서 얻어진 인자들을 이용하여 EGSnrc 기반의 DOSXYZnrc 코드로 몬테칼로 계산을 수행하였으며, EBT 필름측정 결과와 비교하였다. DOSXYZnrc 코드의 선원 모델링 특성 상 후장전 장치의 $^{192}Ir$ 선원들을 직육면체 형태로 근사화하여 모델링하였으며 계산 시 체적소의 크기는 $2{\times}2{\times}2\;mm^3$로 하였다. 균질 매질 내에서는 TG-43 기반의 선량계산 결과와 몬테칼로 선량계산 결과가 잘 일치함을 확인할 수 있었으나 고밀도 물질이 포함된 비균질 매질 내에서는 오차가 커졌다. 환자의 경우 A점 및 B점의 오차는 3% 이내, 평균선량 오차는 5% 정도였다. 그러나 기존 선량계산 알고리듬의 경우 고밀도 물질의 영향을 적절히 고려하지 못하여 표적의 선량을 과대평가하여 실제로는 더 적은 선량이 들어갈 우려가 있다. 본 연구에서 제안된 선량계산 검증체계는 타당하며 선량 계산 결과도 실제와 잘 일치함을 확인할 수 있었다. 또한 기존의 선량계산 알고리듬으로 계산된 치료계획결과를 확인할 경우에는 주의가 필요하며, 몬테칼로 방법과 같은 독립적인 검증 시스템이 유용할 것이다.