• Title/Summary/Keyword: HDR

Search Result 315, Processing Time 0.028 seconds

Feasibility Study of Source Position Verification in HDR Brachytherapy Using Scintillating Fiber

  • Moon, Sun Young;Jeong, EunHee;Lim, Young Kyung;Chung, Weon Kyu;Huh, Hyun Do;Kim, Dong Wook;Yoon, Myonggeun
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2016
  • The position verification of the radiation source utilized in brachytherapy forms a critical factor in determining the therapeutic efficiency. Currently, films are used to verify the source position; however, this method is encumbered by the lengthy time interval required from film scanning to analysis, which makes real-time position verification difficult. In general, the source position accuracy is usually tested in a monthly quality assurance check. In this context, this study investigates the feasibility of the real-time position verification of the radiation source in high dose rate (HDR) brachytherapy with the use of scintillating fibers. To this end, we construct a system consisting of scintillating fibers and a silicon photomultiplier (SiPM), optimize the dosimetric software setup and radiation system characteristics to obtain maximum measurement accuracy, and determine the relative ratio of the measured signals dependent upon the position of the scintillating fiber. According to the dosimetric results based on a treatment plan, in which the dwell time is set at 30 and 60 s at two dwell positions, the number of signals is 31.5 and 83, respectively. In other words, the signal rate roughly doubles in proportion to the dwell time. The source position can also be confirmed at the same time. With further improvements in the spatial resolution and scintillating fiber array, the source position can be verified in real-time in clinical settings with the use of a scintillating fiber-based system.

Enhanced High Contrast Image Rendering Method Using Visual Properties for Sharpness Perception (시각 선명도 감각 특성을 이용한 개선된 고명암 대비 영상 렌더링 기법)

  • Lee, Geun-Young;Lee, Sung-Hak;Kwon, Hyuk-Ju;Sohng, Kyu-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.8
    • /
    • pp.669-679
    • /
    • 2013
  • When an image is converted from HDR (high dynamic range) to LDR (low dynamic range), a tone mapping process is the essential component. Many TMOs (tone mapping operators) have been motivated by human vision which has lower physical luminance range than that in real scene. The representative of human vision properties which motivate TMOs is the local adaptation. However, TMOs are ultimately compressing image information such as contrast, saturation, etc. and the compression causes defects in image quality. In this paper, in order to compensate the degradation of the image which is caused by TMOs, the visual acuity-based edge stop function is proposed for applying the property of human vision to base-detail separation. In addition, using CSF (contrast sensitivity function) which represents the relationship among spatial frequency, contrast sensitivity, and luminance, the sharpness filter is designed and adaptively applied to the detail layer in regard to surround luminance.

Evaluation of Absorbed Dose According to the Nanoparticle in Prostate Cancer Brachytherapy (전립선암의 근접치료 시 나노입자에 따른 흡수선량평가)

  • Park, Eun-tae;Lee, Deuk-hee;Im, In-chul
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.167-172
    • /
    • 2018
  • This study evaluated absorbed dose of brachytherapy according to the nanoparticle in prostate cancer which many occurred in Korean man and provided basic data. Absorbed dose evaluation was using MCNPX program which was applied Monte Carlo simulation. Source was applied $^{192}Ir$ which was many using in Korean HDR machine and gold, ferric oxide, gadolinium and iodine nanoparticle were applied. Prostate absorbed dose result was increased when using nanoparticle, in particular gold nanoparticle was the highest result as $3.13E-03J/kg{\cdot}e$. Absorbed dose of surrounding organs and distance was similar between using nanoparticle and non-using nanoparticle. Therefore, brachytherapy was used nanoparticle was increased therapeutic ratio and efficiency of radiation therapy.

Analysis of High Dose Rate Intracavitary Radiotherapy(HDR-ICR) Treatment Planning for Uterine Cervical Cancer (자궁경부암의 고선량율 강내치료 선량계획 분석)

  • Chai, Gyu-Young
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.387-392
    • /
    • 1994
  • Purpose : This study was done to confirm the reference point variation according to variation in applicator configuration in each fractioation of HDR ICR. Materials and Methods : We analyzed the treatment planning of HDRICR for 33 uterine cervical cancer patients treated in department of therapeutic radiology from January 1992 to February 1992. Analysis was done with respect to three view points-Interfractionation A point variation, interfractionation bladder and rectum dose ratio variation, interfractionation treatment volume variation. Interfractionation A point variation was defined as difference between maximum and minimum distance from fixed rectal point to A point in each patient. Interfractionation bladder and rectum dose ratio variation was defined as difference between maximum and minimum dose ratio of bladder or rectum to A point dose in each patient, Interfractionation treatment volume variation was defined as difference between miximum and minimum treatment volume which absorbed over the described dose-that is, 350 cGy or 400 cGy-in each patient. Results The mean of distance from rectum to A point was 4.44cm, and the mean of interfractionation distance variation was 1.14 cm in right side,1.09 cm in left side. The mean of bladder and rectum dose ratio was $63.8\%$ and $63.1\%$ and the mean of interfractionation variation was $14.9\%$ and $15.8\%$ respectively. With fixed planning administration of same planning to all fractionations as in first fractionation planning-mean of bladder and rectum dose ratio was $64.9\%$ and $72.3\%$.and the mean of interfraction variation was $28.1\%$ and $48.1\%$ reapectively. The mean of treatment volume was $84.15cm^3$ and the interfractionation variation was $21.47cm^2$. Conclusion : From these data, it was confirmed that there should be adapted planning for every fractionation ,and that confirmation device installed in ICR room would reduce the interfractionation variation due to more stable applicator configuration.

  • PDF

Enhanced Fast Luma Adjustment for High Dynamic Range Television Broadcasting (고-휘도 텔레비전 방송을 위한 개선된 빠른 휘도 조절 기법)

  • Oh, Kyung Seok;Kim, Yong-Goo
    • Journal of Broadcast Engineering
    • /
    • v.23 no.2
    • /
    • pp.302-315
    • /
    • 2018
  • Highly non-linear electro-optical transfer function of the Perceptual Quantizer was approximated by a truncated Taylor series, resulting in a closed form solution for luma adjustment. This previous solution is fast and quite suitable for the hardware implementation of luma adjustment, but the approximation error becomes relatively large in the range of 600~3,900 cd/m2 linear light. In order to reduce such approximation error, we propose a new linear model, for which a correction is performed on the position and the slope of line based on the scope of approximation. In order to verify the approximation capability of the proposed linear model, a comparative study on the luma adjustment schemes was conducted using various high dynamic range test video sequences. Via the comparative study, we identified a significant performance enhancement over the previous fast luma adjustment scheme, where a 4.65dB of adjusted luma t-PSNR gain was obtained for a test sequence having a large portion of saturated color pixels.

A Study on Editing HDV in Non-Linear Editing System (비선형 편집 시스템에서의 HDV 편집에 관한 연구)

  • Park, Sung-Dae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.147-151
    • /
    • 2008
  • Since the first HDV(High Definition Video) camcoder, HDR-FX1 with 1080i resolution, had been launched at 2004, the image capture and record with HD resolution have been possible by the various types of camcoder and recorder which can support the HDV format. At a present day, a non-linear editing system, which is composed of only one computer, can capture, edit and export the image with HDV format. The HDV format has the same class of resolution with HD and the same data transfer bit rate of DV(Digital Video). Additionally, the image with HDV format can be recorded in 6mm DV cassette tape. It is possible because the HDV format uses the concept of Long GOP(Gorup of pictures) method for its compression. In this paper, the characteristic feature of HDV format, the essential factors in editing with HDV format and the concept of Long GOP method for its compression have been studied for the way of effective HDV editing.

  • PDF

Lightweight Attention-Guided Network with Frequency Domain Reconstruction for High Dynamic Range Image Fusion

  • Park, Jae Hyun;Lee, Keuntek;Cho, Nam Ik
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.06a
    • /
    • pp.205-208
    • /
    • 2022
  • Multi-exposure high dynamic range (HDR) image reconstruction, the task of reconstructing an HDR image from multiple low dynamic range (LDR) images in a dynamic scene, often produces ghosting artifacts caused by camera motion and moving objects and also cannot deal with washed-out regions due to over or under-exposures. While there has been many deep-learning-based methods with motion estimation to alleviate these problems, they still have limitations for severely moving scenes. They also require large parameter counts, especially in the case of state-of-the-art methods that employ attention modules. To address these issues, we propose a frequency domain approach based on the idea that the transform domain coefficients inherently involve the global information from whole image pixels to cope with large motions. Specifically we adopt Residual Fast Fourier Transform (RFFT) blocks, which allows for global interactions of pixels. Moreover, we also employ Depthwise Overparametrized convolution (DO-conv) blocks, a convolution in which each input channel is convolved with its own 2D kernel, for faster convergence and performance gains. We call this LFFNet (Lightweight Frequency Fusion Network), and experiments on the benchmarks show reduced ghosting artifacts and improved performance up to 0.6dB tonemapped PSNR compared to recent state-of-the-art methods. Our architecture also requires fewer parameters and converges faster in training.

  • PDF

Development of compound eye image quality improvement based on ESRGAN (ESRGAN 기반의 복안영상 품질 향상 알고리즘 개발)

  • Taeyoon Lim;Yongjin Jo;Seokhaeng Heo;Jaekwan Ryu
    • Journal of the Korea Computer Graphics Society
    • /
    • v.30 no.2
    • /
    • pp.11-19
    • /
    • 2024
  • Demand for small biomimetic robots that can carry out reconnaissance missions without being exposed to the enemy in underground spaces and narrow passages is increasing in order to increase the fighting power and survivability of soldiers in wartime situations. A small compound eye image sensor for environmental recognition has advantages such as small size, low aberration, wide angle of view, depth estimation, and HDR that can be used in various ways in the field of vision. However, due to the small lens size, the resolution is low, and the problem of resolution in the fused image obtained from the actual compound eye image occurs. This paper proposes a compound eye image quality enhancement algorithm based on Image Enhancement and ESRGAN to overcome the problem of low resolution. If the proposed algorithm is applied to compound eye image fusion images, image resolution and image quality can be improved, so it is expected that performance improvement results can be obtained in various studies using compound eye cameras.

Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans (고선량률 근접치료계획의 정도보증 프로그램)

  • Han Youngyih;Chu Sung Sil;Huh Seung Jae;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.238-244
    • /
    • 2003
  • Purpose: The Planning of High-Dose-Rate (HDR) brachytherapy treatments are becoming individualized and more dependent on the treatment planning system. Therefore, computer software has been developed to perform independent point dose calculations with the integration of an isodose distribution curve display into the patient anatomy images. Meterials and Methods: As primary input data, the program takes patients'planning data including the source dwell positions, dwell times and the doses at reference points, computed by an HDR treatment planning system (TPS). Dosimetric calculations were peformed in a $10\times12\times10\;Cm^3$ grid space using the Interstitial Collaborative Working Group (ICWG) formalism and an anisotropy table for the HDR Iridium-192 source. The computed doses at the reference points were automatically compared with the relevant results of the TPS. The MR and simulation film images were then imported and the isodose distributions on the axial, sagittal and coronal planes intersecting the point selected by a user were superimposed on the imported images and then displayed. The accuracy of the software was tested in three benchmark plans peformed by Gamma-Med 12i TPS (MDS Nordion, Germany). Nine patients'plans generated by Plato (Nucletron Corporation, The Netherlands) were verified by the developed software. Results: The absolute doses computed by the developed software agreed with the commercial TPS results within an accuracy of $2.8\%$ in the benchmark plans. The isodose distribution plots showed excellent agreements with the exception of the tip legion of the source's longitudinal axis where a slight deviation was observed. In clinical plans, the secondary dose calculations had, on average, about a $3.4\%$ deviation from the TPS plans. Conclusion: The accurate validation of complicate treatment plans is possible with the developed software and the qualify of the HDR treatment plan can be improved with the isodose display integrated into the patient anatomy information.

Development of ATSC3.0 based UHDTV Broadcasting System providing Ultra-high-quality Service that supports HDR/WCG Video and 3D Audio, and a Fixed UHD/Mobile HD Service (HDR/WCG 비디오와 3D 오디오를 지원하는 초고품질 방송서비스와 고정 UHD/이동 HD 방송 서비스를 제공하는 ATSC 3.0 기반 UHDTV 방송 시스템 개발)

  • Ki, Myungseok;Seok, Jinwuk;Beack, Seungkwon;Jang, Daeyoung;Lee, Taejin;Kim, Hui Yong;Oh, Hyeju;Lim, Bo-mi;Bae, Byungjun;Kim, Heung Mook;Choi, Jin Soo
    • Journal of Broadcast Engineering
    • /
    • v.22 no.6
    • /
    • pp.829-849
    • /
    • 2017
  • Due to the large-scale TV display, the convergence of broadcasting and broadband, and the advancement of signal compression and transmission technology, terrestrial digital broadcasting has evolved into UHD broadcasting capable of providing simultaneous broadcasting of fixed UHD and mobile HD. The Korean standard for terrestrial UHDTV broadcasting is based on ATSC 3.0, the broadcasting standard of North America. The terrestrial UHDTV broadcasting standard chose that as a new AV codec standard, HEVC video codec which can compress with higher efficiency compared to AVC, and MPEG-H 3D audio codec for realistic audio. Also, DASH and MMT are adopted as transmission format instead of MPEG-2 TS to support broadband as well as broadcasting network, and in order to provide 4K UHD/mobile HD service simultaneously ROUTE multiplexing technology is applied. In this paper, we propose an audio/video encoder, which is required to provide HDR/WCG supported high quality video service, 10.2 channel/4 object supporting stereo sound service, fixed UHD and mobile HD simultaneous broadcasting service based on ATSC3.0, also we implemented the ATSC 3.0 LDM system for ROUTE/DASH packager, multiplexing system and physical layer transmission/reception, and verified the service ability by applying it to real time broadcast environment.