• Title/Summary/Keyword: HDP

Search Result 97, Processing Time 0.034 seconds

Implementation of ISO/IEEE 11073-10404 Monitoring System Based on U-Health Service (유헬스 서비스 기반의 ISO/IEEE 11073-10404 모니터링 시스템 구현)

  • Kim, Kyoung-Mok
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.6
    • /
    • pp.625-632
    • /
    • 2014
  • The u-health service is using portable device such as smart device and it consists of small computing device. The u-health service carry out same performance with desktop computer. We designed message structure based on Bluetooth HDP. This message structure is used to transmit patient's biometric data on the smart device of medical team, patient and family over the mobile network environment. ISO/IEEE 11073 PHD standard was defined based on the method of communication between the agent and the manager. And We are confirmed the reliable transmission of biometric data at the smart device by implementing the android OS based patient information monitoring application to check the status of patient for medical team, patient and family.

Plasma Charge Damage on Wafer Edge Transistor in Dry Etch Process (Dry Etch 공정에 의한 Wafer Edge Plasma Damage 개선 연구)

  • Han, Won-Man;Kim, Jae-Pil;Ru, Tae-Kwan;Kim, Chung-Howan;Bae, Kyong-Sung;Roh, Yong-Han
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.109-110
    • /
    • 2007
  • Plasma etching process에서 magnetic field 영향에 관한 연구이다. High level dry etch process를 위해서는 high density plasma(HDP)가 요구된다. HDP를 위해서 MERIE(Magnetical enhancement reactive ion etcher) type의 설비가 사용되며 process chamber side에 4개의 magnetic coil을 사용한다. 이런 magnetic factor가 특히 wafer edge부문에 plasma charging에 의한 damage를 유발시키고 이로 인해 device Vth(Threshold voltage)가 shift 되면서 제품의 program 동작 문제의 원인이 되는 것을 발견하였다. 이번 연구에서 magnetic field와 관련된 plasma charge damage를 확인하고 damage free한 공정조건을 확보하게 되었다.

  • PDF

A Study on Home Healthcare Convergence for IEEE 11073 Standard (IEEE 11073 표준을 위한 홈 헬스케어 융합에 대한 연구)

  • Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.422-427
    • /
    • 2015
  • Medical paradigm shift has been based on disease treatment into wellness care so that changes need more IT-based smart medical services. In addition, individual based smart devices are more focused on healthcare services and can provide access to personal medical information, health conditions and social welfare managed by users. In this paper, IEEE11073 PHD (Personal Health Devices) and HL7 (Health Level 7) standards of legacy healthcare devices are developed for communicating with each individual based smart device and providing healthcare service in smart TV environment through a unified home healthcare gateway.

The Properties of Multi-Layered Optical Thin Films Fabricated by Pulsed DC Magnetron Sputtering (Pulsed DC 마그네트론 스퍼터링으로 제조된 다층 광학박막의 특성)

  • Kim, Dong-Won
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.4
    • /
    • pp.211-226
    • /
    • 2019
  • Optical thin films were deposited by using a reactive pulsed DC magnetron sputtering method with a high density plasma(HDP). In this study, the effect of sputtering process conditions on the microstructure and optical properties of $SiO_2$, $TiO_2$, $Nb_2O_5$ thin films was clarified. These thin films had flat and dense microstructure, stable stoichiometric composition at the optimal conditions of low working pressure, high pulsed DC power and RF power(HDP). Also, the refractive index of the $SiO_2$ thin films was almost constant, but the refractive indices of $TiO_2$ and $Nb_2O_5$ thin films were changed depending on the microstructure of these films. Antireflection films of $Air/SiO_2/Nb_2O_5/SiO_2/Nb_2O_5/SiO_2/Nb_2O_5/Glass$ structure designed by Macleod program were manufactured by our developed sputtering system. Transmittance and reflectance of the manufactured multilayer films showed outstanding value with the level of 95% and 0.3%, respectively, and also had excellent durability.

A Study on Performance Evaluation of Container-based Virtualization for Real-Time Data Analysis (실시간 데이터 분석을 위한 컨테이너 기반 가상화 성능에 관한 연구)

  • Choi, BoAh;Han, JaeDeok;Oh, DaSom;Park, HyunKook;Kim, HyeonA;Seo, MinKwan;Lee, JongHyuk
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.05a
    • /
    • pp.32-35
    • /
    • 2020
  • 본 논문은 실시간 데이터 분석을 위한 컨테이너 가상화 기술 사용에 대한 효용성을 알아보기 위해 HDP 와 MapR 배포판에 포함된 Spark 를 도커라이징 전과 후 환경에 설치 후 HiBench 벤치마크 프로그램을 이용해 성능을 측정하였다. 그리고 성능 측정치에 대해 대응표본 t 검정을 이용하여 도커라이징 전과 후의 성능 차이가 있는지를 통계적으로 분석하였다. 분석 결과, HDP 는 도커라이징 전과 후에 대한 성능 차이가 있었지만 MapR 은 성능 차이가 없었다.

The Evaluation of Usefulness of 99Mo-99mTc Generator Using(n,γ)99Mo Developed by Korea Atomic Energy Research ((n,γ)99Mo를 이용한 99Mo-99mTc발생기의 유용성 평가)

  • Seo, Han Kyung;Kim, Jeong Ho;Shim, Cheol Min;Kim, Byung Cheol;Choi, Do Cheol;Gwon, Yong Ju;Park, Yung Sun;Kim, Dong Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.48-52
    • /
    • 2013
  • Purpose: The Molybdenum which is the raw material of $^{99}Mo-^{99m}Tc$ generator is produced from the nuclear reactor. However, output has dwindled as the two nuclear reactors supplying the bulk of radioactive material-one in Chalk River, Ontario and the other in Petten, the Netherlands-have been closed for repairs or maintenance. This resulted in the enhancement of its price. So $^{99}Mo-^{99m}Tc$ generator using$(n,{\gamma})^{99}Mo$ is developed by Korea Atomic Energy Research Institute (KAERI). Medicinal availability of this generator is evaluated in this study. Materials and Methods: The radioactivity of $^{99m}Tc$ eluted in generator 1, 2 and 3 unit developed by KAERI was measured. The quality control test of generator such as appearance test, pH test, LAL test, sterility test, chemical impurity (Al) test and radiochemical purity test were performed. Planar and SPECT/CT image sof SD rat (6 weeks, Female) at 2 hr after injection of $^{99m}Tc-HDP$ (hydroxymethylenediphosphonate) (TechneScan HDP, Malinckrodt Medical, Dutch) and $^{99m}Tc-DPD$ (diphosphono-1, 2-propanedicarboxylicacid) (TECEOS, CIS bio international, France) which were labeled with $^{99m}Tc$ eluted in KAERI and commercial generator (40.5 GBq, Malinckrodt Medical, Dutch) using SPECT/CT camera (Symbia, Siemense, Germany) were obtained respectively. Results: The mean radioactivity of $^{99m}Tc$ elution generator 1unit was 4.18 GBq (113 mCi), generator 2 unit was 4.73 GBq (128 mCi) and generator 3 unit was 3.33 GBq (90 mCi). All quality control tests were within normal limit except pyrogentest. Pyrogen test was positive. Planar and SPECT/CT images of rat injected $^{99m}Tc-HDP$ which was labeled with $^{99m}Tc$ eluted in commercial generator show increased uptake in bone, stomach and bowl. Planar images show increased uptake in liver and bone in case of $^{99m}Tc-DPD$. However, images of rat injected $^{99m}Tc-HDP$ and $^{99m}Tc-DPD$ which were labelled $^{99m}Tc$ eluted in KAERI generator show increased uptake in bone, liver and spleen. Conclusion: If shortcoming is removed such as pyrogen and liver appearance, domestic role as an alternative generator is thought to be able to fill and to secure the national medical service by supplying $^{99m}Tc$ when the supply of $^{99m}Tc$ be comes short.

  • PDF

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Electrochemical Properties of Dye-sensitized Solar Cells Using TiO2 Paste Prepared by Simple Process (Simple 프로세스로 제조된 TiO2 페이스트를 이용한 염료감응 태양전지의 전기화학적 특성)

  • Zhao, Xing Guan;Park, Ju-Young;Gu, Hal-Bon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.718-724
    • /
    • 2014
  • In this work, in order to manufacture the photoelectrode of dye-sensitized solar cells, the different anatase $TiO_2$ paste was prepared by simple route using hydrothermal method. In comparison with the traditional preparing process, the hydrothermally synthesized $TiO_2$ gel was used to make paste directly. Thus, the making process was simplified and the solar conversion efficiency was improved. In comparison with 5.34% solar energy efficiency of HP-1 photoelectrode, the 6.23% efficiency of HDP-1 electrode was improved by 16.67%. This is because hydrothermally synthesized $TiO_2$ gel was used to make paste directly, the dispersibility between $TiO_2$ particles was improved and get the smoother network, leading to the charge transport ability of the electron generated in dye molecular was improved. Further, HDP-2 photoelectrode delivered the best results with Voc (open circuit voltage), Jsc (short circuit current density) FF (fill factor) and ${\eta}$(solar conversion efficiency) were 0.695 V, $15.81mA\;cm^{-2}$, 61.48% and 6.80%, respectively. In comparison with 5.34% of HP-1 photoelectrode, it was improved by 27.34%.

(CyOz)-SiHx 전구체로 중착된 저유전상수 유동박막의 산소 분압에 따른 특성 연구

  • Lee, Chae-Min;O, Hyo-Jin;Kim, Hun-Bae;Park, Ji-Su;Park, Dae-Won;Jeong, Dong-Geun;Kim, Dae-Gyeong;Chae, Hui-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.344-344
    • /
    • 2013
  • 칩의 크기가 감소함에 따라 RC (Resistance, Capacitance) 지연, 전력소비증가 및 신호잡음 등이 문제가 되어왔다. RC지연 문제는 배선에 알루미늄 보다 비저항이 낮은 구리를 사용하고 절연막으로 유전상수가 낮은 물질을 사용하여 개선될 수 있다. 이와 같은 맥락에서 점차 저유전상수 박막의 필요성은 증가하고 있다. 그러므로 이를 개선하기 위해 저 유전상수 값을 가지는 물질을 개발 혹은, UV나 플라즈마 그리고 열을 이용하여 처리하는 연구가 절실히 요구되고 있으며, 현재 많은 연구가 진행되고 있다. 이 논문에서 저유전박막은 HDP-CVD (High Density Plasma Chemical Vapor Deposition) 시스템에서 (CyOz)-SiHx와 O2의 비율을 각각 변화시키면서 증착 되었다. (CyOz)-SiHx와 O2의 비율은 60/150, 60/180, 60/210, 60/240로 증가하면서 증착하였다. 그리고 surface profilometer을 이용하여 박막의 증착율을 측정하고 LCR meter를 이용하여 정전용량을 측정하여 유전상수 값을 얻었다. 박막의 화학적 조성과 구조는 FTIR (Fourier Transform Infrared Spectroscopy)로 측정하였다. 박막의 유동 특성은 SEM (Scanning electron microscope) 이미지로 살펴보았다.

  • PDF

Comparison and Analysis of Subject Classification for Domestic Research Data (국내 학술논문 주제 분류 알고리즘 비교 및 분석)

  • Choi, Wonjun;Sul, Jaewook;Jeong, Heeseok;Yoon, Hwamook
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.178-186
    • /
    • 2018
  • Subject classification of thesis units is essential to serve scholarly information deliverables. However, to date, there is a journal-based topic classification, and there are not many article-level subject classification services. In the case of academic papers among domestic works, subject classification can be a more important information because it can cover a larger area of service and can provide service by setting a range. However, the problem of classifying themes by field requires the hands of experts in various fields, and various methods of verification are needed to increase accuracy. In this paper, we try to classify topics using the unsupervised learning algorithm to find the correct answer in the unknown state and compare the results of the subject classification algorithms using the coherence and perplexity. The unsupervised learning algorithms are a well-known Hierarchical Dirichlet Process (HDP), Latent Dirichlet Allocation (LDA) and Latent Semantic Indexing (LSI) algorithm.