• 제목/요약/키워드: HAS3

검색결과 97,978건 처리시간 0.089초

3차원 입체조형치료에 대한 간암의 선량분포와 정상조직손상확률의 평가 (Evaluation of DVH and NTCP in Hepatoma for 3D Conformal Radiation Therapy)

  • 정갑수;양한준;고신관
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.79-82
    • /
    • 1997
  • Image-based three dimensional radiation treatment planning(3D RTP) has a potential of generating superior treatment plans. Advances in computer technology and software developments quickly make 3D RTP a feasible choice for routine clinical use. However, it has become clear that an evaluation of a 3D plan is more difficult than a 2D plan. A number of tools have been developed to facilitate the evaluation of 3D RTP both qualitatively and quantitatively. For example, beam's eye view(BEV) is one of the most powerful and time-saving method as a qualitative tools. Dose-volume histogram(DVH) has been proven to be one of the most valuable methods for a quantitative tools. But it has a limitation to evaluate several different plans for biological effects of the tissue and critical organ. Therefore, there is a strong interest in developing quantitative models which would predict the likely biological response of irradiated organs and tissues, such as tumor control probability(TCP) and normal tissue complication probability(NTCP). DVH and NTCP of hepatoma were evaluated for three dimensional conformal radiotherapy(3D CRT). Also, 3D RTP was analysed as a dose optimization based on beam arrangement and beam modulation.

  • PDF

Factors Affecting the Intention to Use Digital Banking in Vietnam

  • NGUYEN, Oanh Thi
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권3호
    • /
    • pp.303-310
    • /
    • 2020
  • The study aims to evaluate the factors affecting the intention to use digital banking in Vietnam. Multivariate data analysis techniques (Cronbach's Alpha test, Confirmatory Factor Analysis, Structure equation model) are used for the survey data collected from 201 customers who have access to digital banking. The analysis results show that: (1) attitude towards the service, perceived usefulness has a positive impacts on the intention to use; (2) convenience does not affect the intention to use digital banking services; (3) perceived usefulness factor has a positive effect on the attitude towards the service; (4) The perceived risk has a negative impact on attitude towards the service; (5) trust has no effect on the attitude towards the service; (6) ease of use has a positive impact on perceived usefulness; (7) trust has a positive effect on perceived risk. From the results of this study, perceived usefulness has a positive effect on attitude and intention to use the service. Therefore, it is necessary to enhance the sense of the usefulness of customers through media advertising and consulting so that customers fully understand the benefits brought about by using digital banking services. Perceived risk has a negative impact on attitude towards the service.

CM(ConstructionManagement)에의 효율적 BIM활용에 관한 연구 (A Study on the good use of Construction Management Model based on BIM)

  • 민영기;김경준
    • 한국디지털건축인테리어학회논문집
    • /
    • 제10권3호
    • /
    • pp.87-95
    • /
    • 2010
  • The CM(Construction Manager) of D-university has been seeking the advice of my BIM-team to adopt CM(Construction Management) and BIM best practices to improve project delivery results, and has authored best practice reports for spatial validation, BIM, 3D, 4D and 5D performance. Building Information Modeling(BIM) Process, Integration, and Adoption looks at BIM implementation from a company and project level laying out a process for companies to use BIM. Following this studies, participants will be able to: 1. BIM participants has been creating a BIM process diagram for a project, and has been evaluating and selecting process options for a specific BIM project. 2. BIM participants has been describing the roles and responsibilities of participants in the BIM process, and has been communicating the BIM process to management, colleagues, and project stakeholders. 3. BIM participants has been identified consistent factors influencing BIM return on investment at the project level and the company level, and has been outlining a process for BIM adoption on the project level and company level.

A RECENT GENERALIZATION OF COFINITELY INJECTIVE MODULES

  • Esra OZTURK SOZEN
    • 호남수학학술지
    • /
    • 제45권3호
    • /
    • pp.397-409
    • /
    • 2023
  • Let R be an associative ring with identity and M be a left R-module. In this paper, we define modules that have the property (δ-CE) ((δ-CEE)), these are modules that have a δ-supplement (ample δ-supplements) in every cofinite extension which are generalized version of modules that have the properties (CE) and (CEE) introduced in [6] and so a generalization of Zöschinger's modules with the properties (E) and (EE) given in [23]. We investigate various properties of these modules along with examples. In particular we prove these: (1) a module M has the property (δ-CEE) if and only if every submodule of M has the property (δ-CE); (2) direct summands of a module that has the property (δ-CE) also have the property (δ-CE); (3) each factor module of a module that has the property (δ-CE) also has the property (δ-CE) under a special condition; (4) every module with composition series has the property (δ-CE); (5) over a δ-V -ring a module M has the property (δ-CE) if and only if M is cofinitely injective; (6) a ring R is δ-semiperfect if and only if every left R-module has the property (δ-CE).

한국에서 최근 7년간 저체중 출생아 및 미숙아 출생률의 변화 (Changes in birth rates of low birth weight and premature infants in Korea over the past 7 years)

  • 김민희
    • Clinical and Experimental Pediatrics
    • /
    • 제51권3호
    • /
    • pp.233-236
    • /
    • 2008
  • In recent years, Korea has experienced a steadily declining birth rate, which is a serious social problem in the country. Although living conditions have improved, the birth rates for low birth weight infants and preterm babies has increased because more and more women choose to give birth later in life and the social environment has changed. The rise in low birth weight infants may increase infant mortality rates and morbidity rates. However, the recent improvements in neonatal care has elevated the survival rate of low birth weight infants up to 90 percent and lowered the weight of the very low birth weight infants that can now be saved. In this study, we used dynamic population statistics from the Korea National Statistical Office, which represents the current trend of social stratification and the population of this period. We analyzed birth records for a seven-year period and studied the changes in the delivery rate of preterm and low birth weight infants and the problems related to those changes. The results show that the rate of low birth weight infants has increased from 3.79% to 4.35% for the past seven years. The rate of preterm babies rose from 3.79% to 4.89%. The number of babies born from mothers aged 35 or more went up from 6.69% to 11.83% of the total number of the babies born. As maternal age has risen, the risks of delivering a preterm or low birth weight infant have also increased.

변압기의 3차원 온도분포 해석 (3-D Analysis of Temperature Distribution in Transformers)

  • 오연호;송기동;선종호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권9호
    • /
    • pp.434-441
    • /
    • 2003
  • This paper deals with the temperature characteristics according to the cooling medium and the duct size in model transformers. For the analysis and the temperature-rise tests, two 400kVA model transformers have been manufactured. One has been filled with the alpha oil as the cooling medium and constructed the duct sizes of $3\textrm{mm}$ and $5\textrm{mm}$ in the low-voltage and high-voltage windings respectively. The other has been filled the beta oil and the duct sizes were $4\textrm{mm}$ and $6\textrm{mm}$. The temperature-rise tests have been performed by the back-to-back method and the load factor has been controlled the range of 90%∼130%. The temperature values have been measured by the thermocouple and from the sixteen points in each transformer. A commercial CFD program "FLUENT" has been used for the analysis of temperature distribution. The geometry of transformer has been modeled to 3-dimensional by using the hybrid calculation mesh including the radiator. And also, the natural convection velocity has been measured at the oil top position, and compared with the calculated results.

자하거(紫河車) 약침이 천식모델 생쥐의 면역세포 및 사이토카인에 미치는 영향 (Effect of Hominis Placenta Herbal Acupuncture on immune cells and cytokines in OVA-induced asthmatic mice)

  • 임지택;박양춘
    • 동의생리병리학회지
    • /
    • 제19권2호
    • /
    • pp.446-451
    • /
    • 2005
  • This experiment was designed to investigate the effect of Mominis Placenta herbal acupuncture solution(HP-HAS) on immune cells and cytokines in murine asthma model. In vivo C57BL/6 mice were sensitized and challenged with OVA for 12 weeks. The experimental group was treated with Hominis Placenta herbal acupuncture solution(HP-HAS) at P'yesu(BL13) for the later 8 weeks(3 times a week) and analyzed by ELISA, flow cytometer. The results were obtained as follows Eosinophils in BALF(bronchoalveolar lavage fluid) of HP-HAS group decreased significantly compared with that of control group. IL-4, IL-5, IL-13, IgE in BALF of HP-HAS group decreased significantly compared with that of control group. Number of $CD3e^-/CCR3^+$, $CD69^+/CD3e^+$, $CD11b^+/Gr-1^+$ cells in the HP-HAS group decreased compared with that of control group.

치골 부위의 CT 적층 영상을 활용한 3D 기하학적 곡면 모델로의 가공 (Construction of 3D Geometric Surface Model from Laminated CT Images for the Pubis)

  • 황호진;문두환;황진상
    • 한국CDE학회논문집
    • /
    • 제15권3호
    • /
    • pp.234-242
    • /
    • 2010
  • 3D CAD technology has been extended to a medical area including dental clinic beyond industrial design. The 2D images obtained by CT(Computerized Tomography) and MRI(Magnetic Resonance Imaging) are not intuitive, and thus the volume rendering technique, which transforms 2D data into 3D anatomic information, has been in practical use. This paper has focused on a method and its implementation for forming 3D geometric surface model from laminated CT images of the pubis. The implemented system could support a dental clinic to observe and examine the status of a patient's pubis before implant surgery. The supplement of 3D implant model would help dental surgeons settle operation plans more safely and confidently. It also would be utilized with teaching materials for a practice and training.

Cytotoxic Effect of Hexavalent Chromium on C6 Glioma Cells

  • Suk Seung-Han
    • 대한의생명과학회지
    • /
    • 제12권3호
    • /
    • pp.261-265
    • /
    • 2006
  • Toxic effect of Hexavalent chromium $(CrO_3)$ on various cells and organs has been well recognized. However, the mechanism and degree of cytotoxicity of $CrO_3$ remain unclear. This study was performed to examine the cytotoxicity of $CrO_3$ on $C_6$ glioma cells by measuring cell viability. The XTT assay, one of the sensitive methods to determine the cell viability, was taken to examine the viability of glioma cells treated with $CrO_3$. In this study, not only decreased the number of glioma cells but morphologic changes of them were noted and cell viability decreased in a time and dose-dependent manner after treated with various concentrations of $CrO_3$ for 48hours. $IC_{90}\;and\;IC_{50}$ values in XTT assay were determined at $25{\mu}M\;and\;55{\mu}M$ $CrO_3$, respectively. These results suggest that Hexavalent chromium has a highly cytotoxic effect and has a time and dose-dependent cytotoxicity on $C_6$ glioma cells.

  • PDF

Alkylquinolinium Halide의 계면활성에 관한 연구 Ⅰ. Dodecylquinolinium Bromide 수용액의 Critical Micelle Concentration (The Study for Surface Activity of Alkylquinolinium Halide Ⅰ. The Critical Micelle Concentration of Solution of Dodecylquinolinium Bromide)

  • 이종만
    • 대한화학회지
    • /
    • 제16권4호
    • /
    • pp.205-207
    • /
    • 1972
  • 새로히 합성한 dodecylquinolinium bromide의 수용액에서 표면장력과 전기전도도 측정치로 부터 critical micelle concentration을 결정하였다. 표면장력법으로 결정한 c.m.c.의 값은 $3.34 {\times} 10^{-3}mole/l$이고 전기전도도법으로 결정한 값은 3.41 {\times} $10^{-3}$mole/l이었다. 이값들은 dodecylpyridinium bromide의 그것보다 작은데 이는 dodecylquinolinium bromide의 소수성 group이 큰데서 오는 것으로 생각된다.

  • PDF