• Title/Summary/Keyword: HA coating

Search Result 358, Processing Time 0.027 seconds

Photodegradation of $TiO_2$ Coating Beads in Photocatalytic System (광분해 시스템을 이용한 $TiO_2$ 코팅비드의 광분해 활성)

  • Park, Seong-Ae;Ha, Jin-Wook;Do, Young-Woong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.11a
    • /
    • pp.397-399
    • /
    • 2007
  • 본 연구는 광전자 촉매시스템을 이용해 $TiO_2$ 졸이 코팅된 구형 비드의 광분해 효율에 대해 고찰한 것이다. $TiO_2$ 졸이 코팅된 구형 비드인 실리카비드 화이트겔(1 2 3형) 세 가지 비드를 사용하였고 실험은 1L 크기의 반응기에 유기 물질을 함유한 인공 폐수를 넣어 비드에 코팅된 $TiO_2$의 분해 활성을 고찰할 목적으로 실행되었다. 그 결과, $500^{\circ}C$에서 3hr에서 소성한 실리카 비드가 가장 뛰어난 반응성을 나타내며 인공폐수에서도 분해활성을 나타내는 것을 확인하였다.

  • PDF

Studies on Improvement Printed Mottle for High Quality Printing

  • Ha, Young-Baeck;Kim, Chang-Keun;Cheong, Hee-Seok;Lee, Yong-Kyu
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06b
    • /
    • pp.495-497
    • /
    • 2006
  • Talc Printing mottle of coated paper is one of the most common and the most difficult problems in offset printing. For a high quality printing, development of new paper coating technologies to prevent print mottle is required. This research focused on improvement of printing mottle. Effects of ink dispersion and printing conditions such as nip conditions, printing pressure and printing speed on printing mottle were investigated with RI tester and IGT tester.

  • PDF

Fabrication of functional aluminum surface through anodization mode transition (양극산화 모드 전환을 통한 기능성 알루미늄 표면 연구)

  • Park, Youngju;Jeong, Chanyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.417-424
    • /
    • 2022
  • This research develops an easy-to-use, environmentally friendly method for fabricating functional 1050 aluminum alloy surfaces with excellent corrosion resistance. Functional aluminum surfaces with various nanostructures are fabricated by controlling the experimental conditions of anodizing process. The experiment used a multi-step anodizing process that alternates between two different anodizing modes, mild anodizing (MA) and hard anodizing (HA), together with a pore-widening (PW) process. Among them, the nanostructured surface with a small solid fraction shows superhydrophobicity with a contact angle of more than 170° after water-repellent coating. In addition, the surface with superhydrophobicity is difficult for corrosive substances to penetrate, so the corrosion resistance is greatly improved.

Milk Protein-Stabilized Emulsion Delivery System and Its Application to Foods

  • Ha, Ho-Kyung;Lee, Won-Jae
    • Journal of Dairy Science and Biotechnology
    • /
    • v.38 no.4
    • /
    • pp.189-196
    • /
    • 2020
  • Milk proteins, such as casein and whey protein, exhibit significant potential as natural emulsifiers for the preparation and stabilization of emulsion-based delivery systems. This can be attributed to their unique functional properties, such as the amphiphilic nature, GRAS (generally recognized as safe) status, high nutritional value, and viscoelastic film-forming ability around oil droplets. In addition, milk protein has been used as a coating material in emulsion-based delivery systems to protect bioactive compounds during food processing and storage owing to its unique functional properties. These properties include the ability to bind lipophilic bioactive compounds and antioxidant activity. In this review, we present the use of milk proteins as emulsifiers for the formation of emulsions and food applications of milk protein-stabilized emulsion delivery systems.

Wear Behaviors of Plasma-Sprayed Coating Layers in Mo and Co-based Alloy (몰리브덴늄 및 코발트 합금을 플라즈마 용사한 피막 층의 마모거동)

  • Lee, S.W.;Kim, B.K.;Ha, G.H.;Nam, T.H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.1
    • /
    • pp.15-25
    • /
    • 1996
  • 자동차엔진의 피스톤-링에 응용할 목적으로 플라즈마 용사 기술로 피막한 몰리부덴늄 및 코발트 합금 피막 층의 마모성질을 비교 조사하였다. Ball-on-disc 형태의 마모기를 사용하여 상온 및 대기 중에서의 마모 및 마찰거동에 대하여 조사하였다. 용사 층의 미세경도 시험도 행하였으며, 용사층의 결정구조를 알기 위해 용사층을 x-선 회절 방법으로 분석하였다. 주사전자현미경을 사용하여 마모면의 표면 형상을 관찰하였다. 여러 용사조건으로 만든 용사층의 미세경도치와 마모거동과의 상관관계를 이해하려고 시도하였다. 주사전자현미경과 EDX를 사용하여 마모시 화학반응층과 마모기구를 규명하고자 하였다. 모리부덴늄 및 코발트 합금 분말을 각각 플라즈마 용사층의 단면을 관찰하여 마모기구을 비교하였다.

  • PDF

Study of plating layer composition and corrosion characteristics according to product type (제품 형태에 따른 도금층 및 부식 특성의 연구)

  • Ha-Neul Kim;Min-Gyu Hong;Byoung-Lok Jang
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.3
    • /
    • pp.185-191
    • /
    • 2023
  • The lifetime and corrosion resistance of the coating depends on its thickness and composition. We checked how the plating progressed according to the shape of the product to be plated. There was no significant difference in the composition or thickness of the plating according to the shape of the separately plated products. Samples of different shapes collected from products with complex shapes showed no significant difference in composition depending on the shape, but significant differences in thickness. This difference is due to the difference in applied current density depending on the shape of the product.

EFFECT OF VARIOUS MECHANICAL TREATMENTS OF HYDROXYAPATITE-COATED IMPLANT SURFACES (Hydroxyapatite 피막 처리된 임프란트에 대한 여러가지 기계적 표면처리방법이 임프란트 표면조도 및 성상에 미치는 영향)

  • Yang, Kyung-Ran;Jung, Oh-Chul;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.131-143
    • /
    • 1994
  • For maintenance of exposed implant in healthy state, it is necessary to treat the surface of implant fixture and provide the surface adjustable to surrounding tissues. Variable techniques have been introduced such as citric acid and air-abrasive system to treat the failed implant. Although when the rough surface of HA coated implant was exposed to oral environment, the surface treatment method with citric acid or air-abrasive system is effective for removal of bacterial endotoxin, it is unsuccessful to prevent plaque deposition due to difficulty in removal of rough surface of HA coated implant. Thus, in this study the method that removes bacterial endotoxin and makes smooch surface without alteration of surface characteristics was studied. HA coated disc manufactured by IMZ Co. Was treated with high speed diamond bur, low speed diamond bur, stone bur, rubber point, jetpolisher. And then its surface state was examined with profilometer and SEM to evaluate the surface smoothness, and its surface component was analyzed with EDX to evaluate wheter the surface characteristics were altered or not. As a result, following results were obtained. When the surface roughness of each implant disc was measured by profilometer, the group I showed a $R_{max}\;2.11{\mu}m$ and the group II, III, IV, V showed a $R_{max2}\;4.17{\mu}m$, $7.28{\mu}m$, $8.61{\mu}m$ and $39.44{\mu}m$ respectively. That is, surface smoothness was highest in the group I and it has been gradually decreased in the group II, III, IV and V. Under the SEM examination, the group I showed relatively smooth surface and the group II showed slightly rougher surface than the group I due to partially remaining HA particles while most HA particle was removed. The group III and IV showed rough topography due to HA particles that was not grinded, and HA coated surface in group V showed very irregular surface with deep groove and prominence. In cross-sectional view, the group I showed uniform surface, and the group III, IV showed rough surface due to remaining HA particles but the thickness of HA coating was remarkably reduced. The group II has similar pattern in group I, and the group V showed about $40{\mu}m$ thickness although it was not constant. By analysis of surface component with EDX, the group II in which the grinding was effective showed a small quantity of calcium and phosphorous and the group III, IV, in which the grinding was incomplete showed calcium and phosphorus peak. In all experimental group, no other than titanium, aluminum, calcium, phosphorus was observed.

  • PDF

The Study on the Surface Structure of Domestic CTP Thermal Plate (국산 CTP Thermal Plate의 표면 구조에 관한 연구)

  • Ha, Young-Baeck;Oh, Sung-Sang;Kang, Hyoung-Gon;Yoo, Keun-Ryong;Lee, Jae-Su
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.2
    • /
    • pp.59-70
    • /
    • 2011
  • Even though we could not count the total amount of plates in Korean printing industry per year, we would suppose the total amount of plates about $20,000km^2$ to $22,000km^2$ per year through our printing experience. On the standard of the end of 2010, it would be the market share of plates are that CTP plate is $9,000km^2$, CTcP plate is$4,000km^2$ and PS plate is $9,000km^2$, such as total amount of plates are $22,000km^2$. When there was no installed CTP setter in Korea, the domestic plate would be over 60% market share of plate in Korean printing industry. But now it would be less than 25% market share of plate. It is necessary to develop domestic CTP thermal plate from now because we have to keep the market share of domestic plate. On the study of the surface structure of substrate, roughness, anodized layer amount and coating amount between domestic CTP thermal plate and foreign CTP thermal plate, it would be the basic to develop domestic CTP thermal plate.

EFFECT OF VARIOUS INODIZING CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANT SURFACE DESIGN (다양한 양극산화막 처리방법이 임프란트 골유착에 미치는 영향)

  • Cha, Soo-Ryun;Lee, Jun;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.417-427
    • /
    • 2008
  • The aim of this study is to investigate the effect of anodizing surface to osseointegration of implant by using of resonance frequency analysis (RFA), quantitative and qualitative assessment of an anodically modified implant type with regard to osseous healing qualities. A total of 96 screw-shaped implants were prepared for this study. 72 implants were prepared by electrochemical oxidation with different ways. 24 (group 1 SP) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid. 24 (group 2GC) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate and 24 (group 3 CMP (Calcium Metaphosphate) Coating were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by CMP coating. Rest of 24 (control group were as a control group of RBM surface. Bone tissue responses were evaluated by resonance frequency analysis (RFA) that were undertaken at 2, 4 and 6 weeks after implant placement in the mandible of mini-pig. Group 1 SP (anodized with sulfuric acid and phosphoric acid implants) demonstrated slightly stronger bone responses than control Group RBM. Group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) demonstrated no difference which were compared with control group. Group 3 GMP (anodized and CMP coated implants) demonstrated slightly stronger and faster bone responses than any other implants. But, all observation result of RF A showed no significant differences between experimental groups with various surface type. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact for group 2 GC. Significantly more bone formation was found inside threaded area for group 2 GC. It was concluded that group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) showed more effects on the bone tissue responses than RBM surface in initial period of implantation. In addition, CMP showed a tendency to promote bone tissue responses.

Electrochromic Properties of Li+-Modified Prussian Blue (리튬이온이 첨가된 프루시안 블루의 전기변색 특성 연구)

  • Yoo, Sung-Jong;Lim, Ju-Wan;Park, Sun-Ha;Won, Ho-Youn;Sung, Yung-Eun
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.126-131
    • /
    • 2007
  • The durability problem of Prussian blue in non-aqueous $Li_+$-based electrolytes has been due to the degradation of the Prussian blue electrode matrix during the insertion/extraction processes by $Li_+$. In this work, we designed and synthesised the Prussian blue without reducing the electrochromic performance in non-aqueous $Li_+$-based electrolytes. Prussian blue was electrodeposited on a glass which has ITO coating, and the coating solution is a mixture solution of $FeCl_3\;and\;K_3Fe(CN)_6$ with deionized water added HCl, KCl, and LiCl, respectively. The durability of Prussian blue was evaluated by an in-situ transmittance measurement during a continuous and pulse potential cycling test, and measured by electroactive layer thickness due to evaluating the degradation.