• Title/Summary/Keyword: H-field measurement

Search Result 454, Processing Time 0.024 seconds

FSI Analysis on a Floating Cylinder by 3D Flow-Structure Interaction (FSI) Measurement System (유동-구조상관(FSI) 3차원 측정시스템에 의한 부유식 실린더 연동운동해석)

  • Doh, D.H.;Sang, J.W.;Hwang, T.G.;Pyeon, Y.B.;Baek, T.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1574-1579
    • /
    • 2004
  • A simultaneous measurement system that can analyze the flow-structure interactions(FSI) has been constructed and analyses on the flow field and the motion field of a floating cylinder was made. The three-dimensional vector fields around the cylinder are measured by 3D-PTV technique while the motion of the cylinder forced by the flow field is measured simultaneously with a newly developed motion tracking algorithm(bidirectional tracking algorithm). The cylinder is pendant in the working fluid of a water channel and the surface of the working fluid is forced sinusoidal to make the cylinder bounced. The interaction between the flow fields and the cylinder motion is examined quantitatively.

  • PDF

Design and Evaluation of a Magnetic Field Generator for Biological Experiment (소동물 실험용 다중코일형 자계발생장치의 설계 및 성능평가)

  • Myung, S.H.;Lee, J.B.;Kim, S.B.;Chu, J.H.;Lee, D.I.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.271-273
    • /
    • 2000
  • A magnetic field generator for small animal study was designed and constructed. For calculation of magnetic fields inside the cage, a three-dimensional calculation program was made. Using this, optimum electric current ratio and position of each coil were determined. Meanwhile, inductance of the generator was calculated for design of power supply. The field measurement results of the manufactured generator showed that the difference between maximum and minimum magnetic field at the living floor was less than 2%.

  • PDF

Orientation and thickness dependence of magnetic levitation force and trapped magnetic field of single grain YBa2Cu3O7-y bulk superconductors

  • Jung, Y.;Go, S.J.;Joo, H.T.;Lee, Y.J.;Park, S.D.;Jun, B.H.;Kim, C.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.1
    • /
    • pp.30-35
    • /
    • 2017
  • The effects of the crystallographic orientation and sample thickness on the magnetic levitation forces (F) and trapped magnetic field (B) of single grain YBCO bulk superconductors were examined. Single grain YBCO samples with a (001), (110) or (100) surface were used as the test samples. The samples used for the force-distance (F-d) measurement were cooled at 77 K without a magnetic field (zero field cooling, ZFC), whereas the samples used for the B measurement were cooled under the external magnetic field of a Nd-B-Fe permanent magnet (field cooling, FC). It was found that F and B of the (001) surface were higher than those of the (110) or (100) surface, which is attributed to the higher critical current density ($J_c$) of the (001) surface. For the (001) samples with t=5-18 mm, the maximum magnetic levitation forces ($F_{max}s$) of the ZFC samples were larger than 40 N. About 80% of the applied magnetic field was trapped in the FC samples. However, the F and B decreased rapidly as t decreased below 5 mm. There exists a critical sample thickness (t=5 mm for the experimental condition of this study) for maintaining the large levitation/trapping properties, which is dependent on the material properties and magnitude of the external magnetic fields.

The measurement of $H_2O_2$ Concentration and Simulation of Electric Field Distribution at Dielectric Tube of one Layer with Globular Dielectric in Water (구형 유전체비드를 가지는 단층절연방전관의 $H_2O_2$ 농도 측정 및 전계분포시뮬레이션)

  • Park, Hong-Jae;Park, Jae-Youn;Lee, Dong-Hoon;Koh, Hee-Seog;Lee, Hyun-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.40-43
    • /
    • 2003
  • In this paper, the electric field distribution in dielectric tube with one layer and spherical dielectric(glass) in water was simulated. The reactor was made up of the spherical dielectric that is diameter : 3.0[mm], glass(${\varepsilon}_r$:5) and one glass plate of thickness(2[mm]), ${\varepsilon}_r$(5) as electrode. The discharge gap was 8[mm). Toget more strong electric field, the dielectric constant should be higher comparatively. Using the spherical dielectric for water discharge in dielectric tube, the location of equipotential line was shifting from the interior to the exterior. At real water discharge experimental, $H_2O_2$ was measured higher generated $H_2O_2$ in water at condition of water rate(1[l/min]) and injector than condition of non-injector or 2-3[l/min])

  • PDF

Installation of Induced Current Measurement Systems in Substations and Analysis of GIC Data during Geomagnetic Storms

  • Choi, Kyu-Cheol;Park, Mi-Young;Ryu, Youngsoo;Hong, Youngsu;Yi, Jong-Hyuk;Park, Sung-Won;Kim, Jae-Hun
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.427-434
    • /
    • 2015
  • Coronal Mass Ejections (CME), which originate from active regions of the Sun's surface, e.g., sunspots, result in geomagnetic storms on Earth. The variation of the Earth's geomagnetic field during such storms induces surface currents that could cause breakdowns in electricity power grids. Hence, it is essential to both monitor Geomagnetically Induced Currents (GICs) in real time and analyze previous GIC data. In 2012, in order to monitor the variation of GICs, the Korean Space Weather Center (KSWC) installed an induced current measurement system at SINGAPYEONG Substation, which is equipped with 765 kV extra-high-voltage transformers. Furthermore, in 2014, two induced current measurement systems were installed on the 345 kV high-voltage transformers at the MIGEUM and SINPOCHEON substations. This paper reports the installation process of the induced current measurement systems at these three substations. Furthermore, it presents the results of both an analysis performed using GIC data measured at the SINGAPYEONG Substation during periods of geomagnetic storms from July 2013 through April 2015 and the comparison between the obtained GIC data and magnetic field variation (dH/dt) data measured at the Icheon geomagnetic observatory.

H/W, S/W Developments of GPIB Interface for Measurement Systems (계측시스템 GPIB 인터페이스의 H/M 및 S/W개발)

  • 나승유;최완규;박민상;배희종;조강석
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.1141-1144
    • /
    • 1999
  • GPIB-based measurement applications are common in every field of multi-instrument environment. Also personal computers and workstations play a key role in measurement ability to create cost-effective instrument control solutions. For simple data acquisition systems which are automated by GPIB interface, standard GPIB controllers add a little burden to the budget for DAQ. In this paper, we provide software and hardware construction methods for cost-effective custom-made GPIB controller boards both for controllers and instruments. This way of tailored configuration to suit a particular application of GPIB-based instrument control solution pays dividends in cost and flexibility for data processing management.

  • PDF

Temperature field measurement and CFD analysis of a jet impinging on a concave surface depending on changes in nozzle to surface distance and the diameter of a circular nozzle (원형 노즐의 직경 변화 및 표면으로 부터의 거리변화에 따른 오목한 표면에 충돌하는 제트의 온도장 측정 및 CFD해석)

  • Yeongmin Jo;Yujin Im;Eunseop Yeom
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.55-62
    • /
    • 2023
  • The characteristic of jet impinging on the concave surface were analyzed through thermographic phosphor thermometry (TPT) and numerical investigation. Under a jet Reynolds number of 6600, nozzle diameters and nozzle-to-surface distances (H/d) were changed 5mm and 10mm and H/d=2 and 5. The RNG k-ε turbulence model can accurately predict the distribution of Nusselt number, compared to other models (SST k-ω, realizable k-ε). Heat transfer characteristics varied with the nozzle diameter and H/d, with a secondary peak noted at H/d =2, due to vortex-induced flow detachment and reattachment. An increase in nozzle diameter enhanced jet momentum, turbulence strength, and heat transfer.

Experimental Study on the Characteristics of Lifted Flames in Laminar Coflow Jets of Propane (층류 프로판 동축류 제트에서 부상화염의 특성에 관한 실험적 연구)

  • Lee, J.;Won, S.H.;Jin, S.H.;Chung, S.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.3
    • /
    • pp.37-46
    • /
    • 2002
  • Characteristics of lifted flames in axisymmetric laminar coflow jets have been investigated experimentally. Approximate solutions for velocity and concentration accounting virtual origins have been proposed for coflow jets to analyze the behavior of liftoff height. From the measurement of Rayleigh intensity for probing the concentration field of propane, the validity of the approximate solutions was substantiated. From the images of OH PLIF and CH chemiluminescence and the Rayleigh concentration measurement, it has been shown that the positions of maximum luminosity in direct photography coincide with the tribrachial points, which were located along the stoichiometric contour. The liftoff height in coflow jets was found to increase highly nonlinearly with jet velocity and was sensitive to coflow velocity.

  • PDF

Method for Measuring pH and Alkalinity of High-Pressure Fluid Samples : Evaluation through Artificial Samples (고압 유체 시료의 pH 및 알칼리도 측정 방법 : 가상 시료를 활용한 실용성 평가)

  • Minseok Song;Soohyeon, Moon;Gitak Chae;Jun-Hwan Bang
    • Journal of Soil and Groundwater Environment
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • As part of monitoring technology aimed at verifying the stability of CO2 geologic storage and mitigating concerns about leakage, a method for measuring the pH and alkalinity of high-pressure fluid samples was established to obtain practical technology. pH measurement for high-pressure samples utilized a high-pressure pH electrode, and alkalinity was measured using the Gran titration method for samples collected with a piston cylinder sampler (PCS). Experimental samples, referencing CO2-rich water and CO2 geologic storage studies, were prepared in the laboratory. The PCS controls the piston, preventing CO2 degassing and maintaining fluid pressure, allowing mixing with KOH to fix dissolved CO2. Results showed a 6.1% average error in high-pressure pH measurement. PCS use for sample collection maintained pressure, preventing CO2 degassing. However, PCS-collected sample alkalinity measurements had larger errors than non-PCS measurements, limiting PCS practicality in monitoring field settings. Nevertheless, PCS could find utility in preprocessing for carbon isotope analysis and other applications. This research not only contributes to the field of CCS monitoring but also suggests potential applications in studies related to natural analogs of CCS, CO2-rock interaction experiments, core flooding experiments, and beyond.

Development of a Superconducting Quantum Interference Device System for Biomagnetic Measurements (생체자기계측을 위한 초전도 양자간섭소자 시스템 개발)

  • Lee, Y.H.;Kwon, H.C.;Kim, J.M.;Park, Y.K.;Park, J.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.11-14
    • /
    • 1996
  • Biomagnetic measurements provide superior spatial and temporal resolutions compared with the present electric measurements. We developed a SQUID system for biomagnetic applications. A magnetic field from the spontaneous ${\tau}$-rhythm activity and an auditory evoked magnetic field have been measured. And a measurement of magnetocardiogram and its field mapping have been done.

  • PDF