• Title/Summary/Keyword: H-Bridge Inverter

Search Result 279, Processing Time 0.026 seconds

A New Control Scheme for Maintaining Balanced DC Voltages in Static Var Compensator(SVC) Using Cascade Multilevel Inverter (직렬형 멀티레벨 인버터를 사용한 무효전력보상장치의 직류전압평형을 위한 새로운 제어기법)

  • Min, Wan-Ki;Min, Joon-Ki;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.179-184
    • /
    • 2005
  • This paper examines the application of high voltage static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). A new switching scheme is developed for the SVC system. To improve the unbalanced problem of the DC capacitor voltages, the rotated switching scheme of fundamental frequency is newly used. The optimized fundamental switching pattern with low switching frequency is adapted to be suitable for high application. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion(THD) low in the output voltage of multilevel inverter. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

Analysis on the Switching Surge Characteristics of a High-Voltage Induction Motor Fed by PWM Inverter Using EMTP

  • Kim Jae-Chul;Song Seung-Yeop;Lee Do-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.22-30
    • /
    • 2005
  • The PWM inverter drive may cause an over voltage at the motor terminal, which imposes severe electric stresses on the inter-turn insulation of motor windings. Unlike low-voltage induction motors, high-voltage induction motors have a stator type of form-wound coil for insulation and are insulated to the slot and the coil. So, this paper presents a PWM 3-level inverter, H-Bridge cascaded 7-level inverter and High-voltage induction motor model. It then analyzes the voltage that generates at the input terminal of the high-voltage induction motor fed by each inverter. Also, in order to examine a factor that influences the switching surge voltage, this paper proposes the system equivalent model and performs the case studies using EMTP.

Converter functioned Buck-boost and Forward operation for driving of Cascaded H-bridge multilevel inverter with a single input source (Cascaded H-bridge 멀티레벨인버터의 단일 입력전원 구동을 위한 Buck-boost와 Forward 기능을 갖는 컨버터)

  • Kwon, Cheol Soon;Kang, Feel-soon
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.453-454
    • /
    • 2011
  • 본 논문에서는 벅-부스트와 포워드 컨버터의 기능을 갖는 컨버터를 제안한다. 제안하는 컨버터는 Cascaded H-bridge 멀티레벨인버터와 같이 다수의 독립된 전원을 요구하는 회로 구조를 단일 입력 전원단으로 구성할 수 있는 특징을 가진다. 벅-부스트 컨버터의 입력 인덕터는 변압기로 대체되며 컨버터 스위치의 ON 동작시 포워드 동작에 의해 변압기 2차측으로 전력전달이 이루어지며, 스위치 OFF시 변압기 1차측 자화인덕턴스에 저장된 에너지가 비절연된 벅-부스트 컨버터의 출력 커패시터로 전달된다. 제안된 컨버터의 동작 모드에 따른 이론적 분석을 시행하고 시뮬레이션을 통해 타당성을 검증한다.

  • PDF

Unification of Input Sources by combination of Boost and Forward converter in Cascaded H-bridge Multilevel Inverter (Boost 컨버터와 Forward 컨버터의 조합을 이용한 Cascaded H-bridge 멀티레벨인버터 입력전원의 단일화)

  • Kwon, Cheol Soon;Kang, Feel-soon
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.455-456
    • /
    • 2011
  • 본 논문에서는 Boost 컨버터와 Forward 컨버터를 조합한 컨버터를 제안한다. 제안하는 컨버터는 시스템 구성상 다수의 독립된 전원을 요구하는 Cascaded H-bridge 멀티레벨인버터와 같은 회로구조에 있어 다수의 독립전원의 확보가 곤란한 경우 단일 입력 전원단으로 시스템을 구성할 수 있는 특징을 가진다. Boost 컨버터의 입력 인덕터는 변압기로 대체되며 컨버터 스위치의 ON 동작시 변압기 일차측 자화인덕턴스에 저장된 에너지가 변압기 이차측과 비절연된 Boost 컨버터의 출력 커패시터로 전달된다. 제안된 컨버터의 동작 모드에 따른 이론적 분석을 시행하고 시뮬레이션을 통해 타당성을 검증한다.

  • PDF

A Modular Bi-Directional Power Electronic Transformer

  • Gao, Zhigang;Fan, Hui
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.399-413
    • /
    • 2016
  • This paper presents a topology for a modular power electronic transformer (PET) and a control scheme. The proposed PET consists of a cascaded H-Bridge rectifier on the primary side, a high-frequency DC/DC conversion cell in the center, and a cascaded H-Bridge inverter on the secondary side. It is practical to use PETs in power systems to reduce the cost, weight and size. A detailed analysis of the structure is carried out by using equivalent circuit. An algorithm to control the voltages of each capacitor and to maintain the power flow in the PET is established. The merits are analyzed and verified in theory, including the bi-directional power flow, variable voltage/frequency and high power factor on the primary side. The experimental results validated the propose structure and algorithm.

Transformerless Cascaded AC-DC-AC Converter for Multiphase Propulsion Drive Application

  • Tao, Xing-Hua;Xu, Lie;Song, Yi-Chao;Sun, Min
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.354-359
    • /
    • 2012
  • A transformerless converter suitable for multiphase drive application is presented in this paper. The topology employs a cascaded H-bridge rectifier as the interface between the grid and multi inverters which drive the multiphase motor. Compared with the conventional structure, the new topology eliminates the input transformer and also has the advantages such as four quadrant operation, simple configuration, low cost, high efficiency, and so on. The control strategies for the grid-side cascade H-bridge rectifier and the motor-side inverter are studied accordingly. Based on the multi-rotational reference frame, modular control scheme is developed to regulate the multiphase drive system. Simulation results show the proper operation of the proposed topology and the corresponding control strategy.

Dynamic Characteristic Analysis of Multi-bridge PWM Inverter SSSC (다중브리지 PWM 인버터로 구성된 SSSC의 동특성 분석)

  • Bae B.Y.;Park S.H.;Ha Y.C.;Kim H.J.;Han B.M.;Kim H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.685-688
    • /
    • 2001
  • This paper proposes an SSSC based on multi-bridge inverters. The dynamic characteristic of the proposed SSSC was analyzed by EMTP simulation and a scaled handware model, assuming that the SSSC is inserted in the transmission line of the one-machine-infinite-bus power system. The proposed SSSC has 6 multi-bridge inverters per phase, which generates 13 pulses for each half period of power frequency. The proposed SSSC generates a quasi-simusoidal output voltage by 90 degree phase shift to the line current The proposed SSSC does not require the coupling transformer for voltage injection, and has a flexibility in operation voltage by increasing the number of series connection.

  • PDF

A New Simplified Vector Control For A High Performance Common-Arm IHCML Inverter (고성능 공통암 IHCML 인버터를 위한 새로운 벡터 제어 방식)

  • Song, Sung-Geun;Park, Sung-Jun;Nam, Hae-Kon;Kim, Kwang-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1071-1079
    • /
    • 2007
  • In this paper, a novel space vector control method for isolated multi-level inverter using 3-phase low frequency transformers is proposed. This method is based on the simplification of the space-vector diagram of a five-level inverter using calculated table into fully programming method. The execution time of the proposed method is about same as that of the method using calculated table. Also, the proposed method is easily applied to other case level inverter. We applied this method into the 3-phase IHCML inverter using common arm. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformers could be reduced compare with an exiting 3-phase multi-level inverter using single phase transformer. In addition, this method generates very low harmonic distortion operation with nearly fundamental switching frequency. Finally, We tested multi-level inverter to clarify electric circuit and reasonableness through Matlab simulation and experiment by using prototype inverter.

The Analysis of Inverter Circuit with Induction Heating Load (유도가열 부하를 갖는 인버터 회로의 해석에 관한 연구)

  • Roh, H.S.;Kwon, K.A.;Yang, W.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.424-427
    • /
    • 1995
  • This paper proposes an analysis of an inverter circuit which has an induction heating load. Two major kinds of the inverters are E-class quasi resonant and half-bridge type. The analyses of induction heating load property and operation property are introduced. A simulation program which implements those properties is also introduced. The results of the simulation program are verified through experimental results.

  • PDF

Analysis of a new Soft-Switching High-Frequency Inverter for High Current (대전류화를 위한 새로운 소프트 스위칭 고주파 인버터의 회로 해석)

  • Lee, E.Y.;Ra, B.H.;Suh, K.Y.;Kwon, S.K.;Lee, H.W.;Kwak, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1187-1189
    • /
    • 2002
  • In the case of an existing high frequency inverter is became forced extinction by quick load change, due to be connected with series inductor on switch, it is destroyed or is generated conduction loss by resistance component in reactor. And, In the operation of high current with a soft switching, conduction loss can not neglect. In this paper, for the high current power source, we make sure of soft swtching operation and reducing surge when the forced extinction by using a connected switch with series inductor. Also, we poropos a topology of the half bridge type high frequency inverter that can be realized high amplitude operation of the load current. And, analyze the circuit to decide an opmtial circuit parameter.

  • PDF