• Title/Summary/Keyword: H/W ratio

Search Result 1,397, Processing Time 0.031 seconds

The Performance & Operation Analysis of a Steam Reformer for MCFC (MCFC용 Steam Reformer 개질성능 분석 및 운전평가)

  • Seo, Hai-Kung;Koh, Joon-Ho;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.11 no.4
    • /
    • pp.149-159
    • /
    • 2000
  • This paper is concerned with the performence of a steam reformer for 25kW class MCFC, which is compared with the theoretically calculated results at various operating conditions. The theoretical $H_2$ production amount and $CH_4$ conversion rate are calculated with variations of temperature and steam/carbon (S/C) ratio using fortran program, and the actual values are measured from flowmeter and gas chromatography. As a result of the comparison of theoretical and actual values, the theoretical $H_2$ production amount is calculated by $24.4m^3/hr$ at the normal operating condition(LNG $9m^3/hr$, S/C ratio 5, absolute pressure $2.77kg/cm^2$, $610^{\circ}C$), but the actual production amount is only $19.4m^3/hr$, which is 79.5% of the theoretical value. Nevertheless, at the normal operating condition, the reformer for 25kW class MCFC performed well for a 2,100 hr long run operation, constantly producing $H_2$.

  • PDF

Measurement Apparatus and Evaluation of the Residual Resistance Ratio ( RRR ) of Superconductors (초전도 선재의 잔류저항비 측정을 위한 장치 제작 및 특성 평가)

  • Kim, S.C.;Oh, S.S.;Ha, D.W.;Ha, H.S.;Jang, H.M.;Ryu, K.S.;Kwon, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1300-1302
    • /
    • 1998
  • Residual resistance ratio ( RRR ) of Cu/Nb-Ti Superconductor wire was evaluated by fixed point method. Our measured value of RRR showed good consistency with the average value obtained from round robin test conducted by IEC/TC 90. Our test results showed that the coefficient of variation ( COV ) was kept within 2 %

  • PDF

A Study on Geosmin Removal of Algae Byproducts by Ozonation and Photocatalysis (오존과 광촉매를 이용한 조류 부산물중 Geosmin 제거에 관한 연구)

  • 김은호;성낙창;최용락
    • Journal of Life Science
    • /
    • v.9 no.5
    • /
    • pp.581-589
    • /
    • 1999
  • This study was carried out to compare ozonation with photocatalysis degradation for removal Geosmin of algae byproduct. The change of pH was decresed from 7.02 to 2.8 after contact time 480 minute for ozonation. In case of UV-germicidal lamp, pH was very quickly increased from 7.02 to 7.5, but Halogen lamp did very slowly change pH. Geosmin degradation ratio was as following, UV-germicidal lamp/TiO2(100mg/L) O3>UV-germicidal lamp/TiO2(50mg/L)>UV-germicidal lamp(10W)>halogen lamp(50W). Instead of TiO2 suspension solution, Geosmin degradation ratio was very low using hollow bead and pellet as coated TiO2. As a result of identifing byproducts, ozonation generated three species of aldehyde such as 3-Heptanone and three species of alcohol such as Heptanal, but photocatalysis formed 1, 14-Tetradecanediol infinitesimally.

  • PDF

Effect of μ-Phase on Microstructural Change of W-Ni-Fe Heavy Alloys (W-Ni-Fe 중합금의 미세조직 변화에 대한 μ-phase의 영향)

  • Kim, Dae-Geon;Kim, Eun-Pyo;Kim, Yeong-Do
    • Korean Journal of Materials Research
    • /
    • v.12 no.1
    • /
    • pp.16-20
    • /
    • 2002
  • In this study, the 95W heavy alloys of 3/7, 5/5 and 7/3 of Ni/Fe ratio were sintered at the temperature range between 1420 and $1480^{\circ}C$ for 1h and their microstructures were discussed for an effect of the ${\mu}$-phase $(Fe_7W_6)$ on the microstructure. The ${\mu}$-phase was observed in the only 95W-1.5Ni-3.5Fe alloy of 3/7 and it is thought to be formed and grown from the surface of the W particle. The W particle was surrounded with the ${\mu}$-phase and there were only the W particles and this phase without Ni-Fe-W matrix at the most part. The ${\mu}$-phase changed the interphase structure in the alloy and the grain growth of the W was suppressed because of interrupting the solution-reprecipitation of the W. The W content in the matrix was considered to be lowered due to the interruption of the solution-reprecipitation and the formation of the ${\mu}$-phase in the .

Liquid-Liquid Extraction for Recovery of Paclitaxel from Plant Cell Cultures by Adding Inorganic Salts (식물세포배양으로부터 파클리탁셀 회수를 위한 무기염이 첨가된 액-액 추출)

  • Ha, Geon-Soo;Kim, Jin-Hyun
    • Korean Chemical Engineering Research
    • /
    • v.54 no.1
    • /
    • pp.135-139
    • /
    • 2016
  • We developed a liquid-liquid extraction method using an inorganic salt to dramatically improve the recovery efficiency of the anticancer agent paclitaxel from plant cell cultures. As a result of liquid-liquid extraction using a diverse types of inorganic salt (NaCl, KCl, $K_2HPO_4$, $NaH_2PO_4$, $NaH_2PO_4{\cdot}2H_2O$), NaCl gave the highest yield (~96%) and lowest partition coefficient (0.053) of paclitaxel. The optimal NaCl/solvent ratio, methylene chloride/MeOH ratio, and pure paclitaxel content for liquid-liquid extraction using NaCl were 1% (w/v), 26% (v/v), and 0.066% (w/v), respectively. Under the optimal conditions developed in the present method, most of the paclitaxel (~96%) was recovered from biomass by a single extraction step. In addition, this method facilitated 3-fold higher recovery efficiency of paclitaxel in a shorter extraction number than the conventional liquid-liquid extraction method.

A Study on the Stability of the Ca-Bentonite Colloids Using a Dynamic Light Scattering Method (동적광산란 방법을 이용한 칼슘벤토나이트 콜로이드의 안정성에 대한 연구)

  • Baik Min-Hoon;Park Jong-Hoon;Cho Won-Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.3
    • /
    • pp.12-19
    • /
    • 2006
  • In this study, the stability of Ca-bentonite colloids from Gyeongju area was studied by investigating the changes in the size of the bentonite colloids using a dynamic light scattering method depending on the geochemical conditions such as pH and ionic strength. Kinetic and equilibrium coagulation behavior of the bentonite colloids was investigated by changing the pH and ionic strength of the bentonite suspensions. The results showed that the stability of the bentonite colloids strongly depended upon contact time, pH, and ionic strength. It was also shown that the bentonite colloids were unstable at higher ionic strength greater than 0.01 M $NaClO_4$ at whole pH values considered. In addition, the stability ratio Wand the critical coagulation concentration (CCC) were also calculated using the data from the kinetic coagulation experiments. The stability ratio W was decreased as the ionic strength increased and varied with pH depending on the ionic strength. The CCC of the Ca-bentonite colloids was about 0.05 M $NaClO_4$ around pH 7.

LCD contrast ratio enhancement method using Carbon Nanotube Back Light Unit and Local Dimming (CNT-BLU Local Dimming 구동을 이용한 LCD Contrast 향상 방법)

  • Min, K.W.;Chung, D.S.;Song, B.G.;Kim, S.L.;Kang, H.S.;Baik, C.W.;Jeong, T.W.;Kim, J.W.;Jin, Y.W.;Cho, J.D.
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.971-972
    • /
    • 2006
  • We have demonstrated Carbon Nanotube Back Light Unit (CNT-BLU) which has a triode structure. Local dimming scheme was introduced to the BLU driving system. With this driving method, contrast ratio enhanced 20 times higher than that of conventional Cold Cathode Fluorescent Lamp (CCFL) BLU.

  • PDF

Analysis of submerged flow characteristics of the improved-pneumatic-movable weir through the laboratory experiments (개량형 공압식 가동보의 잠김흐름 특성 분석을 위한 실험연구)

  • Lee, Kyung Su;Jang, Chang-Lae;Lee, Namjoo
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.7
    • /
    • pp.615-623
    • /
    • 2016
  • This Study calculated the Submerged Flow Characteristics and Discharge coefficient by the rising angular change of the Improved-Pneumatic-Movable. According to the result, the smaller the ratio of weir height and weir length (L/W) or the weir standing angle, the bigger of the downstream head ($H_2$). The change of discharge reduction factor ($Q_s/Q_1$), by the hight from weir crest to downstream surface and the ratio form weir crest to upstream water height ($h_t/H$), was decreased when the $h_t/H$ closed to number 1. Although the weir water depth of the down-stream was shallower level than the up-stream, the velocity was faster then before. And the more the flow, the less the gab between the upper and lower reaches level. And when the same flow condition, the downstream head ($H_2$) was increased when the L/W was bigger. The Submerged Flow Discharge coefficient of Improved-Pneumatic-Movable weir was made by the upstream approach flow head and the upper lower stream flow condition, not by the physical data of Movable weir.

Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndrome Using Pen-type Piezoresistive Sensor (펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가)

  • Ha, Ye-Jin;Cho, Mun-Young;Yun, Jong-Min;Jun, Kyu-Sang;Park, Soo-Jung;Shin, Sun-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.257-271
    • /
    • 2012
  • Objectives : The purpose of this study was to confirm that the pulse analyzer is useful for analyzing characteristics of variables of pulse waves in age categories, evaluating pulse waves of the metabolic syndrome group, compared with those of the non-metabolic syndrome group in Korean adults. Methods : The pulse wave variables were measured in Guan of all 1,056 subjects by the pulse analyzer, using a pen-type piezoresistive sensor. The physical measurement, blood test and survey were also performed by each subject. Results : In the age categories, height of pre-incisura (h2), height of tidal wave (h3), area of percussion wave (Aw), and width of percussion wave (w) increased in accordance with increase in age. While ratio of systolic period area (As) went up according to the increase of age, ratio of diastolic period area (Ad) went down. Radial augmentation index (R-AI), h2/h1, h3/h1, w/t and angle of percussion wave went up by aging, generally. Aw rate (Aw/At) also increased. Among the metabolic syndrome group, in the ages of 19 and 44, ratio of systolic period area (As) was higher and ratio of diastolic period area (Ad) was lower than in the non-metabolic group. w/t, Aw/At, and angle of percussion wave were higher than in the non-metabolic syndrome group. Among the metabolic syndrome group over the age of 60, height of pre-incisura (h2), height of tidal wave (h3), total area (At), area of percussion wave (Aw), radial augmentation index (R-AI), h2/h1 and h3/h1 were higher than in the non-metabolic syndrome group. Conclusions : The pulse analyzer is useful to analyze arterial stiffness in the age categories and in the metabolic syndrome group by some measures.