• Title/Summary/Keyword: Gunsan

Search Result 471, Processing Time 0.029 seconds

A Study on Tranquility by the Development of New Type Floating Breakwater (신형식부방파제의 개발과 정온도에 관한 연구)

  • Lee, Hyun Jin;Kim, Do Sam;Shin, Moon Seup
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.3
    • /
    • pp.154-164
    • /
    • 2013
  • In this study, a new type floating breakwater was proposed to improve the capability of wave attenuation compared with the existing floating breakwater in Wonjun Port, which is located in Masan City, Korea. In order to develop the optimal design, many different configurations considering the shape and location of vertical barrier and horizontal plate were examined based on the shape of existing floating breakwaters in Wonjun and Tongyeong Port. The analytical and numerical results of the new type floating breakwater showed better performance in long-period wave attenuation than the existing floating breakwater in Wonjun. Therefore, the new type floating breakwater can improve harbor tranquility in Wonjun Port.

A Study on Greenhouse Gas Emission Characteristics for Regional Governments (A Case Study of Jeonbuk Province) (지자체 온실가스 배출특성 분석연구-전라북도 14개 시·군 사례)

  • Jang, Nam-Jung;An, Jeong-Yi;Kim, Tae-Kyun;Im, Seoung-Hyun;Kim, Deug-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.2
    • /
    • pp.225-237
    • /
    • 2011
  • For each local town (6 cities and 8 counties) affiliated with Jeonbuk provincial government, characteristics of greenhouse gas (GHG) emissions were analyzed and key emission areas were drawn to establish mitigation policies of the regional greenhouse gases. National Institute of Environmental Research (NIER) reported that the total greenhouse gas emission of Jeonbuk was 20.93 million $tCO_2e$ in 2006. The inland area of 5 cities and 1 county (Jeonju, Gunsan, Iksan, Jungeup, Kimje, Wanju) covered 82% of total greenhouse gas emission in Jeonbuk, while the rest local towns of the province, mostly from mountainous areas were responsible for the rest of the total GHG emission. The cities and counties having relatively higher emission in Jeonbuk province were influenced dominantly by the emission from energy and waste sections. Also, agricultural section showed similar tendency except industrial cities such as Gunsan and Jeonju. In the internal portion of city and county, energy section showed the highest portion at the range of 72.1 (Sunchang)~97.0% (Jeonju) and agricultural section was at the range of 1.2% (Jeonju)~26.6 (Sunchang). When the portion of energy section was higher, the lower agricultural section. The emission index was applied to decide the key city and county and the potential city and county with two methodologies in this study. It was required that the key emission areas were drawn to establish regional greenhouse gases mitigation policies.

Molecular Detection of Toxoplasma Gondii in Haemaphysalis Ticks in Korea

  • Kim, Ju Yeong;Kwak, You Shine;Lee, In-Yong;Yong, Tai-Soon
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.3
    • /
    • pp.327-331
    • /
    • 2020
  • Toxoplasma gondii are intracellular protozoa that can cause neurological disease or death in fetuses and even in immunocompromised human adults. Ticks are recognized as vectors of many microorganisms including viruses, bacteria, and protozoa. Recent studies detected T. gondii in various tick species in many countries. In this study, we performed PCR detection of the T. gondii B1 gene from Haemaphysalis ticks collected from vegetation in 4 localities, Wonju, Gunsan, Miryang, and Yangsan, in Korea. We analyzed DNA from 314 ticks (268 Haemaphysalis longicornis and 46 Haemaphysalis flava) and the B1 gene of T. gondii was detected in 13 of these. The detection of T. gondii in ticks differed significantly by region (P=0.021). T. gondii was detected in the following percentages of collected ticks: 3.7% (7 of 189) in Gunsan, 10% (5 of 50) in Wonju, 16.7% (1 of 6) in Yangsan, and 0% (0 of 69) in Miryang. The detection of T. gondii in ticks was not associated with tick species or development stage. This is the first report of T. gondii detection in ticks in Korea. Our results provide important information necessary to understand toxoplasmosis transmission.

A Study on Dry and Wet Wipe Test for Radioisotope Leakage Checking (방사성동위원소 누설 점검을 위한 건식 및 습식 문지름 시험법 연구)

  • Park, SangMin;Yoo, SeungHee;Choi, KyuSeok;Lee, HwaHyung;Hong, Sayong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.305-312
    • /
    • 2018
  • A dry and wet wipe test for radioisotope leakage checking was conducted by fixing the radioisotope $^{14}C$ to the glass surface and used for observing the transfer factor and surface shape of the test paper through wipe test. The dry wipe test showed that transfer factor in the tissue paper was twice as high as in the paper filter, and the wet wipe test showed that transfer factor in the paper filter paper was three times higher than the tissue paper. Although paper filters are general choice for leakage checking, it has been shown that tissue paper can be an alternative in the dry wipe test.

Eutrophication Modelling in Gunsan Estuary (군산하구 해역에서의 부영양화 모델링)

  • Kim, Jong-Gu;Jung, Tae-Ju;Kang, Hoon;Kim, Jun-Woo;Lee, Nam-Do
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2003.05a
    • /
    • pp.191-200
    • /
    • 2003
  • Gunsan coastal area is one of region increasing pollution problems. One of the most important factors that cause eutrophication is nutrient materials containing nitrogen and phosphorus which stem from excreation of terrestial sources. At this study, the three-dimensional numerical hydrodynamic and ecosystem model, which was developed by Institute for Resources and Environment of Japan, were applied to analyze the processes affecting the eutrophication. The residual currents, which were obtained by integrating the simulated tidal currents over 1 tidal cycle, showed the presence of a typical. Density driven currents were generated westward at surface and eastward at the bottom in Geum estuary area where the fresh waters are flowing into. The ecosystem model was calibrated with the data surveyed in the field of the study area in annual average. The simulated results of DIN were fairly good coincided with the observed values within relative error of 32.39%. correlation coefficient(r) of 0.99. In the case of DIP, the simulated results were fairly good coincided with the observed values within relative error of 24.26%, correlation coefficient (r) of 0.82. The simulations of DIN and DIP concentrations were performed using ecosystem model under the conditions of 20 ∼ 80% pollution load reductions from pollution sources. In study area, concentration of DIN and DIP were reduced to 20∼80% and under 10% in case of the 80% reduction of the input loads from fresh water respectively. But pollution loads from sediment had hardly affected DIN and DIP concentration. For the environment management of coastal areas, in case of Kunsan area, the most important pollution sources affecting eutrophication phenomenon were found to be the input loads from fresh water.

  • PDF

Aerosol Vertical Distribution Measured by LIDARs in Baengnyeongdo, Munsan, and Gunsan during 10~11 May 2010 (백령도, 문산, 군산의 라이다로 측정한 에어로졸 연직분포 -2010년 5월 10~11일 황사를 중심으로-)

  • Lee, Hae-Jung;Kim, Jeong Eun;Chun, Youngsin
    • Atmosphere
    • /
    • v.23 no.4
    • /
    • pp.519-526
    • /
    • 2013
  • This study aims to analyze the vertical distribution of Asian dust measured by LIDARs at three weather stations in Baengnyeongdo (BND), Munsan (MS), and Gunsan (GS) during 10~11 May 2010, and thereby investigate their effectiveness. Asian dust passed through from central to south-western part of Korea. Although dust particles were detected over the surface in MS and GS, LIDAR data showed that the Asian dust with non-spherical particles was observed in all of the three regions. It seems that the naked-eye observation could not detect dust over the surface of BND due to the temperature inversion below a height of 0.45 km. During the Asian dust events, the duration time of dust presented 9.5 hr (BND), 19.5 hr (MS), and 24.5 hr (GS), respectively with the longest time in GS, whereas dust altitudes ranged from 0.4 to 1.3 km (BND), 0.1 to 2.8 km and 4.1 to 4.2 km (MS), and 0.2 to 2.0 km (GS), respectively, while showing the highest altitude in MS. Aerosol optical thickness (AOT) retrieved by LIDAR and skyradiometer (SR), located close to the LIDAR sites, was compared. MS (LIDAR) and Seoul (SR) attained the AOT of 0.64 and 0.50, and GS (LIDAR) and Gongju (SR) attained the AOT of 0.38 and 0.54, respectively. As SR-derived angstrom exponents (AE) during the time period determined as Asian dust by LIDAR data were 0.17 in Seoul (near MS) and 0.30 in Gongju (near GS), it can be said that the characteristics of dust particles were appeared. During the study period, depolarization ratio could serve as a useful indicator to determine dust aerosol. But, it still seems essential to conduct further investigation with longer period of data to better describe the discrepancy of AOT between LIDARs and SR.

Growth Chracteristics, Vitamin C Content and Antioxidative Activity among Local Strains of Sedum sarmentosum (돌나물 수집종간 생육특성, 비타민 C 함량 및 항산화 활성)

  • Kim, Hyo-Jin;Jung, Seung-Ho;Bae, Jong-Hyang;Lee, Seung-Yeob
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.110-115
    • /
    • 2008
  • To evaluate growth chracteristics, vitamin C content and antioxidative activity of Sedum sarmentosum, 13 local strains were cultivated in the field. Keumsan, Bucheon, and Pocheon strains had narrow and oblong leaf, long hight, and slender stem compared to the other strains. Wanju and Gunsan strains were not formed flower stalks, and did not flower during the flowering time. Vitamin C contents were ranged from 407.8 to $434.4\;mg{\cdot}kg^{-1}$, and it was high in Gwangyang, Buan, Wanju, and Gunsan strains. But vita min C contents didn't show a significant difference among strains. In antioxidative activity between fresh and freeze dried shoots, electron donating abilities (EDA) were ranged from 45.0 to 66.5% in MeOH extract of fresh shoot, and from 61.3 to 66.5% in MeOH extract of freeze dried shoot. Gwangyang, Suncheon, Wando strains showed high EDA compared to the others. Vitamine C content and antioxidant activity were highest in Gwangyang strain.

A study on comparing short-term wind power prediction models in Gunsan wind farm (군산풍력발전단지의 풍력발전량 단기예측모형 비교에 관한 연구)

  • Lee, Yung-Seop;Kim, Jin;Jang, Moon-Seok;Kim, Hyun-Goo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.3
    • /
    • pp.585-592
    • /
    • 2013
  • As the needs for alternative energy and renewable energy increase, there has been a lot of investment in developing wind energy, which does not cause air pollution nor the greenhouse gas effect. Wind energy is an environment friendly energy that is unlimited in its resources and is possible to be produced wherever the wind blows. However, since wind energy heavily relies on wind that has unreliable characteristics, it may be difficult to have efficient energy transmissions. For this reason, an important factor in wind energy forecasting is the estimation of available wind power. In this study, Gunsan wind farm data was used to compare ARMA model to neural network model to analyze for more accurate prediction of wind power generation. As a result, the neural network model was better than the ARMA model in the accuracy of the wind power predictions.

The Study of Nutrient Intakes, Blood Lipids and Bone Density According to Obesity Degree Among University Students in Jeonbuk (전북지역 대학생의 비만도 분류에 따른 영양소 섭취, 혈중지질 및 골밀도에 관한 연구)

  • Chang, Hye-Soon
    • Korean Journal of Human Ecology
    • /
    • v.23 no.4
    • /
    • pp.743-757
    • /
    • 2014
  • The purpose of this study was to compare nutrient intakes, blood lipids and bone density of male(n=69) and female(n=71) according to the obesity index by %Fat. The average energy intakes of obesity group was higher than normal group in male & female(p<0.001). The protein and fat intakes among three energy nutrients for male were higher than normal group(p<0.05~0.01), and carbohydrate intake of obesity group in female was higher than the other groups. TG, TC/HDL, blood glucose, blood pressure in male were higher than female(p<0.01~0.001), but HDL in male was lower than female. TC/HDL and diastolic blood pressure of obesity group were higher than normal group in male(p<0.05), but had not significant in female. Blood glucose in male was higher than female(p<0.001). T-score of forearm(=-1.26) and calcaneus(=0.42) for female were lower than male(=-0.63, 0.83), and T-score of calcaneus for obesity group(=1.03) in female was higher than normal group(=0.10). The T-score of forearm for obesity group in female was higher than the other group, but was not significant. These results suggest that ratio among three energy nutrients was kept balance for obesity group, especially, fat must be reduced in male than female, carbohydrate will be reduced in female than male to prevent obesity. Nutritional education for treatment obesity to prevent hyperlipidemia and arteriosclerosis is important for male too. T-score of forearm was lower than calcaneus in female, so exercise with arm than leg would be required to accumulate calcium in bone and to increase muscle to prevent osteoporosis.

A Case Study on Explosive Demolition of Gunsan Steam Power Station in Republic of Korea (군산화력발전소 발파해체 실용화 시험시공 사례)

  • Min, Hyung-Dong;Song, Young-Suk;Kim, Hyo-Jin;Seo, Young-Soo
    • Explosives and Blasting
    • /
    • v.25 no.2
    • /
    • pp.11-21
    • /
    • 2007
  • The main structure of Gunsan steam power station was demolished by the toppling method using high explosives. Height of a main building is 58m and a total floor area is $292,000m^2$. It is Rahmen(rigid-frame) structure consisted of almost columns and beams and slabs exist only in one part of the building for the electricity generators equipments. To improve the efficiency of blasting work, it is separated into 4 sectors. Blasting floors were 1, 2, 3, & 4 stories from first sector to third sector, while 1, 2, 5, & 7 of fourth sector were blasted because it had not slabs. About 102.675 kg of the MegaMITE were used with 225 electric detonator and 638 non-electric detonators to check detonator connection and confidence of detonation. The blasting noise and vibration were monitored to evaluate the environment effect and the damage of the nearby structures.