• Title/Summary/Keyword: Guidewire

Search Result 18, Processing Time 0.022 seconds

Folded-Loop Guidewire Remodeling Technique: Catheterizing Markedly Angulated Branches during Intravascular Embolization (Folded-Loop Guidewire Remodeling Technique: 색전술 시 급격한 분지 각도를 가지는 혈관의 선택적 진입 방법)

  • Dong Hyun Kim;Ung Rae Kang;Young Hwan Kim;Jung Guen Cha
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.418-426
    • /
    • 2023
  • Purpose Practical challenges are encountered in percutaneous intravascular procedures when applied to markedly angulated branching vessels. Herein, we introduced a folded-loop guidewire remodeling technique-the guidewire-shaping technique-to overcome difficult catheterization. Materials and Methods First, the tip of a 0.014-inch micro-guidewire was manually shaped like a pigtail loop. Second, the shaped guidewire was introduced into the microcatheter and was preloaded into the hollow metal introducer for suitability with the microcatheter hub. Gentle rotation of the guidewire after release from the microcatheter can create the preshaped pigtail loop configuration. On pulling back, the loop loosened, the configuration was changed to a small U-shaped tip, and the guidewire tip was easily introduced into the target artery. Results Between December 2019 and January 2022, the described technique was used in 64 patients (male/female, 49/15; mean age, 66.8 ± 9.5 years) for selective arterial embolization, after failed attempts with the conventional selection technique. The technique was successful in 63/64 patients (98%). The indications of embolization include transcatheter arterial chemoembolization, gastrointestinal bleeding, hemoptysis, trauma-induced bleeding, and tumor bleeding. Conclusion The folded-loop guidewire remodeling technique facilitates the catheterization of markedly angulated branching arteries; when usual catheterization method fails.

Multifunctional Robotic Guidewire System using Spiral-type Magnetic Microrobot with Magnetic Manipulation

  • Yu, Chang-Ho;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.616-621
    • /
    • 2016
  • This paper presents a new multifunctional active guidewire system for medical applications that uses a magnetic microrobot. The study demonstrated that the proposed microrobot system could swim and be controlled under Low-Reynolds-number (Re) environments in blood vessel models. The prototype of the robotic guidewire, which is driven within a three-axis Helmholtz coil system, consists of a guide-wire, spiral blade, drilling tip, and permanent magnet. The spiral-type microrobot showed stable active locomotion between 3 kA/m and 9.1 kA/m under driving frequency up to 70 Hz in a silicone oil (of viscosity 1000 cst). The microrobot produced a maximum moving velocity of $8.08{\times}10^{-3}m/s$ at 70 Hz and 9.1 kA/m. In particular, the robotic guidewire produced 3D locomotion with drilling in the three-axis Helmholtz coil system. We verified active locomotion, towing of guidewire, steering, and drilling of the proposed robotic guidewire system through experimental analyses.

Usefulness of the double-guidewire technique for endoscopic procedures in the field of biliary and pancreatic diseases

  • Mamoru Takenaka;Masatoshi Kudo
    • Clinical Endoscopy
    • /
    • v.55 no.5
    • /
    • pp.605-614
    • /
    • 2022
  • The double-guidewire method has been increasingly used in endoscopic procedures for biliary and pancreatic diseases in recent years, including endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography-related procedures. In addition, double-lumen catheters with uneven distal and proximal lumen openings have been introduced, making it possible to easily create a double-guidewire situation, and the usefulness of the double-guidewire technique using uneven double-lumen cannulas has been widely reported. Although the advantages of using two guidewires depend on the particular situation and the appropriate use of the two guidewires, deepening the knowledge of the double-guidewire method will contribute greatly to troubleshooting in daily practice. In this review, the usefulness of the double-guidewire technique is discussed with respect to two main areas: selective insertion of guidewires and devices and biliary cannulation.

Does the direction of J-tip of the guide-wire influence the misplacement of subclavian catheterization?

  • Kang, Changshin;Cho, Sunguk;Ahn, Hongjoon;Min, Jinhong;Jeong, Wonjoon;Ryu, Seung;Oh, Segwang;Kim, Seunghwan;You, Yeonho;Park, Jungsoo;Lee, Jinwoong;Yoo, Insool;Cho, Yongchul
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.636-640
    • /
    • 2018
  • Objective: Central venous catheter (CVC) misplacement can result in incorrect readings of the central venous pressure, vascular erosion, and intravascular thrombosis. Several studies have examined the correlation between the guidewire J-tip direction and misplacement rate. This study examined whether the guidewire J-tip direction (cephalad vs. caudad) affects the misplacement rate in right subclavian venous catheterization. Methods: This prospective randomized controlled study was conducted between February 2016 and February 2017. The subjects were divided into two groups (cephalad group vs. caudad group) and the misplacement rate was compared according to guidewire J-tip direction in each group. Results: Of 100 patients, the cephalad and caudad groups contained 50 patients each. The age, sex, and operator experience were similar in the two groups. In the cephalad group, misplacement of CVC insertion into the ipsilateral internal jugular vein occurred in two cases. In the caudad group, misplacement of CVC insertion into the contralateral subclavian vein occurred in one case, with loop formation in the brachiocephalic trunk in one case. Guidewire J-tip direction showed no significant correlation with CVC misplacement. Conclusion: The guidewire J-tip direction does not influence the rate of misplacement.

Surgical Retrieval of Fractured Percutaneous Coronary Intervention Guidewire (경피적 관상동맥 중재술 시 골절된 가이드 와이어의 외과적 제거)

  • Lee Jun-Wan;Kim Sang-Pil
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.640-642
    • /
    • 2006
  • Entrapment and fracture of coronary angioplasty hardware are rare complications of percutaneous coronary intervention (PCI). Retained guidewire should be removed either percutaneously or surgically, because it could serve as a nidus for thrombus formation. We report on a successful surgical retrieval of entrapped PCI guidewire and subsequent bypass grafting of the affected coronary vessel.

Double-guidewire technique for selective biliary cannulation does not increase the rate of post-endoscopic retrograde cholangiopancreatography pancreatitis in patients with naïve papilla

  • Han Taek Jeong;June Hwa Bae;Ho Gak Kim;Jimin Han
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.226-236
    • /
    • 2024
  • Background/Aims: This study aimed to compare the safety of the double-guidewire technique (DGT) with that of the conventional single-guidewire technique (SGT) in real-world situations. Methods: A total of 240 patients with naïve papilla who underwent endoscopic retrograde cholangiopancreatography (ERCP) at Daegu Catholic University Medical Center between January 2021 and December 2021 were included. The primary outcome was the rate of post-ERCP pancreatitis (PEP) in the SGT and DGT groups. Results: A total of 163 patients (67.9%) belonged to the SGT group, and 77 (32.1%) belonged to the DGT group. The rates of successful biliary cannulation were 95.7% and 83.1% in the SGT and DGT groups, respectively (p=0.002). In the study group, PEP occurred in 14 patients (5.8%). The PEP rates were not significantly different between the SGT and DGT groups (4.3% vs. 9.1%, p=0.150). In the multivariate analysis, the age of <50 years (odds ratio [OR], 9.305; 95% confidence interval [CI], 1.367-63.358; p=0.023) and hyperlipidemia (OR, 7.384; 95% CI, 1.103-49.424; p=0.039) were significant risk factors for PEP in the DGT group. Conclusions: DGT did not increase the PEP rate in patients with naïve papilla. In addition, the age of <50 years and hyperlipidemia were significant risk factors for PEP in the DGT group.

Endoscopic ultrasound-guided portal vein coiling: troubleshooting interventional endoscopic ultrasonography

  • Shin Haba;Kazuo Hara;Nobumasa Mizuno;Takamichi Kuwahara;Nozomi Okuno;Akira Miyano;Daiki Fumihara;Moaz Elshair
    • Clinical Endoscopy
    • /
    • v.55 no.3
    • /
    • pp.458-462
    • /
    • 2022
  • Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (HGS) is widely performed not only as an alternative to transpapillary biliary drainage, but also as primary drainage for malignant biliary obstruction. For anatomical reasons, this technique carries an unavoidable risk of mispuncturing intrahepatic vessels. We report a technique for troubleshooting EUS-guided portal vein coiling to prevent bleeding from the intrahepatic portal vein after mispuncture during interventional EUS. EUS-HGS was planned for a 59-year-old male patient with unresectable pancreatic cancer. The dilated bile duct (lumen diameter, 2.8 mm) was punctured with a 19-gauge needle, and a guidewire was inserted. After bougie dilation, the guidewire was found to be inside the intrahepatic portal vein. Embolizing coils were placed to prevent bleeding. Embolization coils were successfully inserted under stabilization of the catheter using a double-lumen cannula with a guidewire. Following these procedures, the patient was asymptomatic. Computed tomography performed the next day revealed no complications.

Caudal Epidural Injection with a Guidewire-Reinforced Epidural Catheter in Patients with Herniated Nucleosus Pulpose (추간판 탈출증 환자에서 길잡이철사가 삽입된 경막외카테터를 이용한 미추경막외조영술)

  • Ko, Justin Sangwook;Lee, Seok Jin;Hwang, Hee Youn;Sim, Woo Seok;Choi, Soo Joo;Kim, Jie Ae;Kim, Chung Su;Hahm, Tae Soo;Kim, Gaab Soo;Cho, Hyun Sung;Kim, Tae Hyeong
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.207-212
    • /
    • 2006
  • Background: The epidural injection technique is a commonly used intervention in the management of chronic spinal pain, which has the advantage of delivering various drugs, such as local anesthetics or steroids, in higher concentrations to the inflamed nerve root. A guidewire-reinforced epidural catheter was introduced through a Tuohy needle during the caudal epidural procedure, with a catheter threaded into the affected nerve roots and the spread-pattern of contrast agents observed under fluoroscopy. Methods: Sixty-seven patients with low back pain, who showed evidence of a herniated nucleus pulposus on magnetic resonance imaging, were included. All patients received fluoroscopically guided caudal epidural injections, with the guidewire-reinforced epidural catheter introduced through a Tuohy needle and threaded either to the right or left side toward the target nerve roots. After confirming the catheter tip position at the affected nerve root, 2 ml increments of contrast agents (up to 6 ml) were injected, and their corresponding AP fluoroscopic views were obtained. Three radiologists reviewed all the radiographic findings and measured the proportion of the area of contrast spread at the side of target nerve roots. Results: Greater proportion of the area of contrast spread was observed at the side of the target nerve roots (P < 0.0001). At each level of contrast injection (2-⁣, 4- ⁣ and 6 ml), more than 70% of the spread of contrast dye was observed at the side of the target nerve roots in 85%, 70%, and 55% of cases, respectively. Conclusions: The combination of a caudal epidural injection and use of a guidewire-reinforced epidural catheter significantly enhances the target specificity, as revealed by the selective spread of contrast dye at the side of target nerves.

Educational Simulation Videos for Performing Resuscitative Endovascular Balloon Occlusion of the Aorta

  • Chang, Sung Wook;Kim, Dong Hun;Chang, Ye Rim
    • Journal of Trauma and Injury
    • /
    • v.33 no.3
    • /
    • pp.140-143
    • /
    • 2020
  • Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been accepted as an adjunct procedure for non-compressible torso hemorrhage in patients with hemorrhagic shock. With appropriate indications, REBOA should be performed for resuscitation regardless of the physician's specialty. Despite its effectiveness in traumatized patients with hemorrhagic shock, performing REBOA has been challenging due to physicians' lack of experience. Even though training in endovascular skills is mandatory, many physicians cannot undergo sufficient training because of the limited number of endovascular simulation programs. Herein, we share simulation video clips, including those of a vascular circuit model for simulation; sheath preparation; long guidewire and balloon catheter preparation; ultrasound-guided arterial access; sheath insertion or upsizing; and balloon positioning, inflation, and migration. The aim of this study was to provide educational video clips to improve physicians' endovascular skills for REBOA.