• Title/Summary/Keyword: Guided mode

Search Result 261, Processing Time 0.023 seconds

Visibility of Internal Target Volume of Dynamic Tumors in Free-breathing Cone-beam Computed Tomography for Image Guided Radiation Therapy

  • Kauweloa, Kevin I.;Park, Justin C.;Sandhu, Ajay;Pawlicki, Todd;Song, Bongyong;Song, William Y.
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.220-229
    • /
    • 2013
  • Respiratory-induced dynamic tumors render free-breathing cone-beam computed tomography (FBCBCT) images with motion artifacts complicating the task of quantifying the internal target volume (ITV). The purpose of this paper is to study the visibility of the revealed ITV when the imaging dose parameters, such as the kVp and mAs, are varied. The $Trilogy^{TM}$ linear accelerator with an On-Board Imaging ($OBI^{TM}$) system was used to acquire low-imaging-dose-mode (LIDM: 110 kVp, 20 mA, 20 ms/frame) and high-imaging-dose-mode (HIDM: 125 kVp, 80 mA, 25 ms/frame) FBCBCT images of a 3-cm diameter sphere (density=0.855 $g/cm^3$) moving in accordance to various sinusoidal breathing patterns, each with an unique inhalation-to-exhalation (I/E) ratio, amplitude, and period. In terms of image ITV contrast, there was a small overall average change of the ITV contrast when going from HIDM to LIDM of $6.5{\pm}5.1%$ for all breathing patterns. As for the ITV visible volume measurements, there was an insignificant difference between the ITV of both the LIDM- and HIDM-FBCBCT images with an average difference of $0.5{\pm}0.5%$, for all cases, despite the large difference in the imaging dose (approximately five-fold difference of ~0.8 and 4 cGy/scan). That indicates that the ITV visibility is not very sensitive to changes in imaging dose. However, both of the FBCBCT consistently underestimated the true ITV dimensions by up to 34.8% irrespective of the imaging dose mode due to significant motion artifacts, and thus, this imaging technique is not adequate to accurately visualize the ITV for image guidance. Due to the insignificant impact of imaging dose on ITV visibility, a plausible, alternative strategy would be to acquire more X-ray projections at the LIDM setting to allow 4DCBCT imaging to better define the ITV, and at the same time, maintain a reasonable imaging dose, i.e., comparable to a single HIDM-FBCBCT scan.

Evaluation of the Lens Absorbed Dose of MVCT and kV-CBCT Use for IMRT to the Nasopharyngeal Cancer Patient (비인두암 환자에 대한 세기조절 방사선치료 시 이용되는 MVCT와 kV-CBCT의 수정체 흡수선량 평가)

  • Choi, Jae Won;Kim, Cheol Chong;Park, Su Yeon;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Purpose: Quantitative comparative evaluation of the difference in eye lens absorbed dose when measured by MVCT and kV-CBCT, though such a dose was not included in the original IMRT treatment plan for the nasopharyngeal cancer patient. Materials and Methods: We used CT (Lightspeed Ultra 16, General Electric, USA) against an Anderson rando phantom (Alderson Research Laboratories Inc, USA) and established the plan for tomotherapy treatment (Tomotherapy, Inc, USA) and linear accelerator treatment (Pinnacle 8.0, Philips Medicle System) for the achieved CT images on the same condition with the nasopharyngeal cancer patient treatment plan. Then, align the ther-moluminescence dosimeter (TLD100 Harshaw, USA) with the eye lens, shot the lens with Tomotherapy MVCT under 3 conditions (Fine, Normal, and Coarse), and shot both lenses with kV-CBCT under 2 conditions (Low Dose Head and Standard Dose Head) 3 times each. Results: When we analyzed the eye lens absorbed dose according to MVCT and kV-CBCT images by using both Tomotherapy and Pinacle 8.0, we achieved the following result; According to Tomotherapy MVCT, RT 0.8257 cGy in the Coarse mode, LT 0.8137 cGy, RT 1.089 cGy and LT 1.188 cGy in the Normal mode, and RT 2.154 cGy and LT 2.082 cGy in the Fine mode. According to Pinacle 8.0 kV-CBCT, RT 0.2875 cGy and LT 0.1676 cGy in the Standard Dose mode and RT 0.1648 cGy and LT 0.1212 cGy in the Low-Dose mode. In short, the MVCT result was significantly different from that of kV-CBCT, up to 20 times. Conclusion: We think kV-CBCT is more effective for reducing the amount of radiation which a patient is receiving during intensity modulated radiation treatment for other purposes than treatment than MVCT, when we consider the absorbed dose only from the viewpoint of image-guided radiation therapy. Besides, we understood the amount of radiation is too sensitive to the shooting condition, even when we use the same equipment.

  • PDF

The SEM and SPM Study on the Change of Machined Titanium Implant Surface following Various Laser Treatments (수종의 레이저로 임프란트 표면 처리 시 표면 형태의 변화에 대한 주사전자 및 주사탐침 현미경적 연구)

  • Kim, In-Kyung;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.451-463
    • /
    • 2001
  • Following the extensive use of implant, the incidence of peri-implantitis increases. Guided bone regeneration has been used for the optimal treatment of this disease. Because implant surface was contaminated with plaque and calculus, cleaning and detoxification were needed for the reosseointegration when guided bone regeneration was performed. Various mechanical and chemical methods have been used for cleaning and detoxification of implant surface, air-powder abrasive and oversaturated citrate were known to be most effective among these methods. However, these methods were incomplete because these could not thoroughly remove bacteria of implant surface, moreover deformed implant surface. Recent studies for detoxification of the implant surface using laser were going on, $CO_2$ laser and Soft Diode laser were known to be effective among these methods. The purpose of this study was to obtain clinical guide by application these laser to implant surface. 15 experimental machined pure titanium cylinder models were fabricated. The $CO_2$ laser treatment under dry, wet and hydrogen peroxide condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of models. Each groups were examined with SPM and SEM to know whether their surface was changed. The results were as follows : 1. Surface roughness and surface form weren't changed when $CO_2$ laser was usedunder dry condition(P>0.05). 2. Surface roughness and surface form weren't changed when $CO_2$ laser was used under wet condition(P>0.05). 3. Surface roughness and surface form weren't changed when $CO_2$ laser was used under hydrogen peroxide condition(P>0.05). 4. Surface roughness and surface form weren't changed when Soft Diode laser was used under toluidine blue O solution condition(P>0.05). From the result of this study, it may be concluded that the $CO_2$ laser having relatively safe pulse mode and the Soft Diode laser used with photosensitizer can be used safely to treat peri-implantitis.

  • PDF

Identification of an ISR-Related Metabolite Produced by Pseudomonas chlororaphis O6 against the Wildfire Pathogen Pseudomonas syringae pv. tabaci in Tobacco

  • Park, Myung-Ryeol;Kim, Young-Cheol;Park, Ju-Yeon;Han, Song-Hee;Kim, Kil-Yong;Lee, Sun-Woo;Kim, In-Seon
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.10
    • /
    • pp.1659-1662
    • /
    • 2008
  • Pseudomonas chlororaphis O6 exhibits induced systemic resistance (ISR) against P. syringae pv. tabaci in tobacco. To identify one of the ISR metabolites, O6 cultures were extracted with organic solvents, and the organic extracts were subjected to column chromatography followed by spectroscopy analyses. The ISR bioassay-guided fractionation was carried out for isolation of the metabolite. High-resolution mass spectrometric analysis of the metabolite found $C_{9}H_{9}O_{3}N$ with an exact mass of 179.0582. LC/MS analysis in positive mode showed an $(M+H)^{+}$ peak at m/z 180. Nuclear magnetic resonance ($^{1}H,\;^{13}C$) analyses identified all protons and carbons of the metabolite. Based on the spectroscopy data, the metabolite was identified as 4-(aminocarbonyl) phenylacetate (4-ACPA). 4-ACPA applied at 68.0 mM exhibited ISR activity at a level similar to 1.0 mM salicylic acid. This is the first report to identify an ISR metabolite produced by P. chlororaphis O6 against the wildfire pathogen P. syringae pv. tabaci in tobacco.

Diffraction Analysis of Multi-layered Grating Structures using Rigorous Equivalent Transmission-Line Theory (정확한 등가 전송선로 이론을 사용한 다층 격자 구조의 회절특성 분석)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.261-267
    • /
    • 2015
  • The eigenvalue problems involving the diffraction of waves by multi-layered grating configurations can be explained by rigorous modal expansion terms. Such a modal solution can be represented by equivalent transmission-line networks, which are generalized forms of simple conventional circuits. This approach brings considerable physical insight into the grating diffraction process of the fields everywhere. In particular, the transmission-line representation can serve as a template for computational algorithms that systematically evaluate dispersion properties, radiation effects and other optical characteristics that are not readily obtained by other methods. To illustrate the validity of the present rigorous approach, the previous research works are numerically confirmed and the results agree well each other.

Influence of Deposition Method on Refractive Index of SiO2 and TiO2 Thin Films for Anti-reflective Multilayers

  • Song, Myung-Keun;Yang, Woo-Seok;Kwon, Soon-Woo;Song, Yo-Seung;Cho, Nam-Ihn;Lee, Deuk-Yong
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.9
    • /
    • pp.524-530
    • /
    • 2008
  • Anti-Reflective (AR) thin film coatings of $SiO_2$ (n= 1.48) and $TiO_2$ (n=2.17) were deposited by ion-beam assisted deposition (IBAD) with End-Hall ion source and conventional electron beam (e-beam) evaporation to investigate the effect of deposition method on the refractive indicies (n) of the fIlms. Green-light generation using a GaAs laser diode was achieved via excitation of the second harmonic. The latter resulted from the transmission of the fundamental guided-mode wave of 1064 nm through periodically poled $LiNbO_3$. Large differences in the refractive indicies of each of the layers in the multilayer coating may improve AR performance. IBAD of $SiO_2$ reduced its refractive index from 1.45 to 1.34 at 1064 nm. Conversely, e-beam evaporation of $TiO_2$ increased its refractive index from 1.80 to 2.11. In addition, no fluctuations in absorption at the wavelength of 1064 nm were found. The results suggest that films prepared by different deposition methods can increase the effectiveness of multilayer AR coatings.

Inhibitory effects of polyphenols isolated from Rhus verniciflua on Aldo-keto reductase family 1 B10

  • Song, Dae-Geun;Lee, Joo-Young;Lee, Eun-Ha;Jung, Sang-Hoon;Nho, Chu-Won;Cha, Kwang-Hyun;Koo, Song-Yi;Pan, Cheol-Ho
    • BMB Reports
    • /
    • v.43 no.4
    • /
    • pp.268-272
    • /
    • 2010
  • Aldo-keto reductase family 1 B10 (AKR1B10) is a member of the NADPH-dependent aldo-keto reductase (AKR) superfamily, and has been considered to be a potential cancer therapeutic target. Total extract from the bark of Rhus verniciflua (Toxicodendron vernicifluum (Stokes)) showed AKR1B10 inhibitory activity. To identify the active compounds from R. verniciflua responsible for AKR1B10 inhibition, nine compounds were isolated via bioactivity-guided isolation and tested for their effects against recombinant human AKR1B10 (rhAKR1B10). Results showed that butein, isolated from the ethyl acetate fraction, was most able to inhibit rhAKR1B10. The inhibitory rate of butein against rhAKR1B10 was 42.86% at $1\;{\mu}M$ with an IC50 value of $1.47\;{\mu}M$, and enzyme kinetic analysis revealed its inhibition mode to be uncompetitive.

유리기판의 광추출 효율 향상을 위한 마스크 제작 공정 없는 플라즈마 식각 연구

  • Seo, Dong-Wan;Gwon, O-Hyeong;Lee, U-Hyeon;Kim, Ji-Won;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.507-507
    • /
    • 2013
  • 유리기판으로 투과되는 빛들 중에는 내부 전반사나 wave-guided mode로 인하여 손실이 일어나 일반적으로 20%의 광추출 효율을 가진다. 이러한 문제점을 해결하기 위한 연구에는 Photonic Crystal과 같은 주기적인 나노 구조물이 있는데 이러한 구조물을 제작하기 위한 마스크 공정 과정은 대부분 복잡하거나 비싼 단점이 있다. 이에 본 발표에서는 마스크 없이 비정질소다라임 유리의 구조물 생성으로 광 추출 효율이 상승하는지 보고자 하였다. M-ICP (Magnetized-Induced Coupled Plasma)란 용량 결합형 플라즈마와 유도 결합형 플라즈마 두 가지 방식의 플라즈마를 이용한 것인데 용량 결합형 플라즈마를 이용해 이온이 sheath에 의해 가속되어 유리표면에 부딪히고 그에 따라 유리가 식각되는 물리적 식각을 이용하였다. 또한 이온의 밀도를 조절하기 위해 유도결합형 플라즈마 방식을 이용하여 식각률을 높였다. 화학적 식각을 위해서는 CF4와 O2혼합 가스를 이용해 F가 Si와 결합하여 SiF4가 되어 사라지고 탄소잔여물인 C는 O2와 반응하여 제거하였다. 그 결과, 랜덤한 분포를 가지는 미세한 구조물(stochastic sub-wavelength structure)을 유리 표면에 형성할 수 있었고, 또한 다양한 가스 종류와 압력, source power와 bias power, 그리고 시간을 바꿔가며 미세 구조물들을 관찰하였다. 실험 결과, 가시광선 파장 이하의 높이를 갖고 수 마이크로미터의 너비를 갖는 구조물이 전반사되는 빛을 효율적으로 추출하는 것을 산란되는 빛의 정도인 diffusive transmittance 가 기존 0%에서 15% 정도로 증가하는 것으로 스펙트로포토미터 측정을 통해 확인하였다. 이러한 유리 기판 위 구조물 생성방법을 OLED에 적용한다면 적은 비용으로 소자의 효율을 크게 향상 시킬 수 있을 것이다. 또한 본 처리 과정의 장점은 기존의 방법에 필요한 스퍼터링이나 RTA 처리 과정이 필요 없어 공정 단가 절감과 제조 공정의 단순화로 높은 생산성을 얻을 수 있으며 대면적화에도 유리하다.

  • PDF

A Study on Development of the High-Power Low-Loss Waveguide Circulator for Ka-band Millimeter-Wave Seeker (밀리미터파대역(Ka-대역)탐색기용 고 전력 저 손실 도파관 순환기 개발에 관한 연구)

  • Jung, Chae-Hyun;Han, Sung-Min;Baek, Jong-Gyun;Lee, Kook-Joo;Park, Chang-Hyun;Kwon, Jun-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.83-88
    • /
    • 2017
  • In this paper, a 3-port waveguide circulator of Ka-band millimeter-wave for isolation between transmit channel and receive channel at high power transmit mode is designed and fabricated for the seeker of the guided missile and circulator performance is verified through the S-parameter, high power and operation temperature test. At the configuration design, interface design between a seeker antenna and the circulator is considered and half-height of standard waveguide is applied for minimum and light weight body. The shape of permanent magnet and ferrite is optimized by simulation and tuning dielectrics at each port are placed for the best performance. In Fc(center frequency)${\pm}1000MHz$, designed waveguide circulator has below -20 dB return loss, below 0.5 dB insertion loss and below -23 dB isolation. It is found that circulator characteristics is similar to design results.

Design of $Ti:LiNbO_3$ Three-Waveguide Optical Switch with Outer-Waveguide Fed (바깥도파로 입사된 $Ti:LiNbO_3$ 세 도파로 광스위치의 설계 및 제작)

  • Kim, Young-Moon;Seo, Jung-Hoon;Huh, Chang-Yul;Kim, Chang-Min
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.6
    • /
    • pp.61-70
    • /
    • 1999
  • An optical switch composed of three-identical, equally-spaced $Ti:LinbO_3$ waveguides and overlaid Al electrodes of CPW structure was designed and fabricated. Patterned Ti was diffused into z-cut $LinbO_3$ substrates at $1025^{\circ}C$ for 6 hours to make a three-waveguide directional coupler. $SiO_2$ buffer layer of $1.2{\mu}m$ was grown by the PECVD to reduce the propagation loss of TM mode, and Al electrodes were built on the layer for switching the guided beam. For an incident beam of ${\lambda}=1.3{\mu}m$, almost perfect optical coupling between two outer waveguides was observed. When an electric field was applied to detune the three waveguides anti-symmetrically, the optical switching phenomenon was successfully confirmed.

  • PDF