• 제목/요약/키워드: Guided implant surgery

검색결과 176건 처리시간 0.02초

Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study

  • Young Woo Song;Seung Ha Yoo;Ui-Won Jung
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권1호
    • /
    • pp.1-11
    • /
    • 2024
  • PURPOSE. The present experiment aimed to evaluate the placement accuracy of fully guided implant surgery using a mucosa-supported surgical guide when the protocol of osteotomy and installation was modified (MP) compared to when the protocol was sequentially and conventionally carried out (CP). MATERIALS AND METHODS. For 24 mandibular dentiform models, 12 dentists (6 experts and 6 beginners) performed fully guided implant placements two times at the right first and second molar sites using a mucosa-supported surgical guide, once by the CP (CP group) and at the other time by the MP (MP group). The presurgical and postsurgical stereolithographic images were superimposed, and the deviations between the virtually planned and actually placed implant positions and the procedure time were compared statistically (P < .05). RESULTS. The accuracies were similar in the CP and MP groups. In the CP group, the mean platform and apex deviations at the second molar site for the beginners were +0.75 mm and +1.14 mm, respectively, which were significantly larger than those for the experts (P < .05). In the MP group, only the mean vertical deviation at the second molar site for the beginners (+0.53 mm) was significantly larger than that for the experts (P < .05). The procedure time was significantly longer for the MP group (+94.0 sec) than for the CP group (P < .05). CONCLUSION. In fully guided implant surgery using a mucosa-supported guide, the MP may improve the placement accuracy when compared to the CP, especially at sites farther from the most-posterior natural tooth.

Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례 (Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis)

  • 김성모;박진홍;류재준;신상완;이정열
    • 대한치과보철학회지
    • /
    • 제56권2호
    • /
    • pp.126-133
    • /
    • 2018
  • Cone beam computerized tomography (CBCT)의 발전은 환자의 해부학적 구조를 3차원적으로 분석할 수 있게 하였다. Surgical guide는 CBCT와 CAD/CAM, 임플란트 진단 소프트웨어의 접목을 통해 미래의 보철물을 계획하고 적합한 위치에 임플란트를 식립할 수 있게 한다. Guided surgery를 통해 해부학적 구조물에 대한 침범을 최소한으로 줄일 수 있고 보다 재현성 있는 치료계획의 설정이 가능하다. 본 증례는 전악 무치악 환자에게 surgical guide를 이용하여 다수의 임플란트를 식립한 증례로 수술시간을 단축시킬 수 있었으며 임시 보철물을 미리 제작함으로써 보다 쉽게 immediate loading을 시행할 수 있었다. 환자는 개선된 안모와 저작기능에 만족하였다.

정신지체장애환자에서 Computer-Guided Surgery를 이용한 임플란트 식립 및 즉시 보철물 장착: 증례보고 (Immediately loaded dental implants with fixed prostheses using a computer-guided surgery in a mental retardation patient: a case report)

  • 한세진
    • 구강회복응용과학지
    • /
    • 제30권3호
    • /
    • pp.246-252
    • /
    • 2014
  • 통상적인 임플란트 치료는 식립 후 약 3 - 5개월 뒤 임플란트 상부 보철물을 제작한다. 이러한 치료과정의 단점으로는 환자가 임플란트 식립 후 보철물이 장착되는 최종 치료 시점까지의 기간 동안 유지력과 저작능력이 떨어지는 임시의 치를 사용하여 생활해야 한다는 것이다. 최근의 임플란트 식립 후 즉시 부하 보철물 치료는 시술 적응증에 따른 제한이 있긴 하지만, 잦은 치과 방문이 어렵고 진료에 대한 협조도가 낮은 정신적, 신체적 장애 환자들에게 더욱 유용하다고 생각된다. 본 증례에서는 삼차원 컴퓨터 유도 수술법을 이용한 임플란트 식립 후 즉시 부하 보철치료를 정신지체장애 환자에서 시행하였으며, 시술 후 좋은 경과를 보였기에 이를 보고하는 바이다.

폭이 좁은 치조골에서 컴퓨터가이드를 이용한 무절개 임플란트 수술로 식립한 narrow implant의 방사선학적 평가 (Radiographic evaluation of marginal bone level alteration around narrow implants placed in narrow alveolar ridge using guided flapless surgery)

  • 정승미;최병호
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.306-312
    • /
    • 2020
  • 목적: 본 연구의 목적은 골폭이 좁은 치조골을 가진 환자에서 컴퓨터가이드를 이용한 무절개 임플란트 수술로 narrow implant 식립 후 최소 6개월 이상 경과한 환자를 대상으로 임플란트 주변의 골소실 예후를 평가하는데 있다. 재료 및 방법: 2017년 1월 1일부터 2019년 6월 30일 사이에 내원한 환자 중 임플란트 순측을 덮고 있는 치조골의 두께가 0.5 mm에서 1.5 mm 사이인 12명의 환자(12개 narrow implant)에서 CBCT를 이용하여 임플란트 순측에 남아 있는 치조골을 평가하였다. 결과: 임플란트를 덮고있는 순측 치조골의 폭이 아주 얇았지만, 수술 즉시 임시보철물을 장착후 6개월 이상 지난 임플란트의 CBCT를 촬영하여 식립전과 식립후 치조골 변화에 대한 방사선학적 평가에서 임플란트의 순측 치조골이 안정적으로 유지됨이 관찰되었다. 결론: 컴퓨터가이드를 이용한 무절개 임플란트 수술은 전치부에 골폭이 좁은 치조골을 가진 환자에서 임플란트 주변의 골소실을 방지하는데 유리함으로 narrow implant와 함께 유용하게 사용할 수 있는 방법으로 생각된다.

임플란트 가이드 수술시 고려사항 (Consideration of computer-guided implant surgery)

  • 김현동
    • 대한심미치과학회지
    • /
    • 제28권1호
    • /
    • pp.4-17
    • /
    • 2019
  • 우리나라 치과의 CBCT 보급률은 세계적으로 높은 편으로, 최근 1만대 보급을 돌파하고 있는 것으로 파악된다. 또한 최근 각 치과 제조업체마다 DLP방식의 In-House방식의 3D 프린터 보급률 또한 가파르게 상승하고 있다. 이에 맞춰 최근 개원가에서 CBCT와 구강 스캔 정보를 이용한 컴퓨터 가이드 임플란트 수술의 활용도가 증가하고 있는 상황이다. 현재 컴퓨터 가이드를 이용한 임플란트 수술 방법에 대해 문헌상 고찰을 통해 리뷰해보고, 또한 정확성 및 신뢰성이 보장되는 가이드 수술을 위한 고려사항에 대해 정리해보고자 한다.

Computer-guided implant surgery를 활용한 상악 무치악 환자의 전악 임플란트고정성 보철물 수복 증례 (Full mouth implant-supported fixed prosthesis restoration of an edentulous maxillary patient using computer-guided implant surgery)

  • 이민태;김성용;임선영;이용상;이근우;김성아
    • 대한치과보철학회지
    • /
    • 제61권1호
    • /
    • pp.63-72
    • /
    • 2023
  • 완전 무치악에서 전악 임플란트 고정성 수복물로 구강회복 치료를 진행할 경우, 해당 악궁의 해부학적 상황과 대합치와의 관계를 고려하여 최종 보철물의 형태와 위치를 결정하는 과정과 이에 따라 다수의 임플란트를 계획된 방향과 각도로 식립하는 과정은 매우 중요하다. 본 증례는 기존 의치의 불편감으로 내원한 상악 무치악 환자를 computer-guided surgery를 통해 상부 보철물에 기반하여 이상적으로 계획된 위치에 임플란트를 식립하였다. 이를 통해 상악 전악 임플란트 고정성 보철물을 제작하여 구강 회복을 진행한 치료로 환자와 술자 모두 기능 및 심미적으로 만족할만한 결과를 얻었기에 이를 보고하고자 한다.

An assessment of template-guided implant surgery in terms of accuracy and related factors

  • Lee, Jee-Ho;Park, Ji-Man;Kim, Soung-Min;Kim, Myung-Joo;Lee, Jong-Ho;Kim, Myung-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.440-447
    • /
    • 2013
  • PURPOSE. Template-guided implant therapy has developed hand-in-hand with computed tomography (CT) to improve the accuracy of implant surgery and future prosthodontic treatment. In our present study, the accuracy and causative factors for computer-assisted implant surgery were assessed to further validate the stable clinical application of this technique. MATERIALS AND METHODS. A total of 102 implants in 48 patients were included in this study. Implant surgery was performed with a stereolithographic template. Pre- and post-operative CTs were used to compare the planned and placed implants. Accuracy and related factors were statistically analyzed with the Spearman correlation method and the linear mixed model. Differences were considered to be statistically significant at $P{\leq}.05$. RESULTS. The mean errors of computer-assisted implant surgery were 1.09 mm at the coronal center, 1.56 mm at the apical center, and the axis deviation was $3.80^{\circ}$. The coronal and apical errors of the implants were found to be strongly correlated. The errors developed at the coronal center were magnified at the apical center by the fixture length. The case of anterior edentulous area and longer fixtures affected the accuracy of the implant template. CONCLUSION. The control of errors at the coronal center and stabilization of the anterior part of the template are needed for safe implant surgery and future prosthodontic treatment.

임플란트 식립시 동종뼈 막의 임상적 활용 (CLINICAL USES OF HOMOLOGOUS GELATINIZED BONE MATRIX(GBM) IN DENTAL IMPLANT SURGERY)

  • 이은영;김경원;엄인웅
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권3호
    • /
    • pp.229-236
    • /
    • 2006
  • The biologic principle of guided bone regeneration(GBR) has been studied extensively in hopes of regenerating alveolar bone. Various materials have been utilized as regenerative membranes and grafting materials in implant surgery. To improve the ability of membranes, several types of membrane have been developed. Various materials have been utilized as regenerative membranes; however, all materials have disadvantages, and the ideal membrane material is yet to be identified. In these cases, a homologous gelatinized bone matrix(GBM) were used as a regenerative material in conjunction with the placement of endosseous root implants. 22 patients participated in this study, and 42 implants were inserted. The result of 1st operative surgery was uneventful, inflammatory reaction and dehiscences were not observed except for only one case. After the final protheses, all implants were functioning successfully. The major advantages in the use of GBMs for guided bone regeneration are of very wide application such as membrane and graft material, and that a second procedure to remove the material is not necessary, and the GBMs are accepted by the surrounding tissues without complications. The purpose of this study was to observe the usefulness of GBMs in dental implant surgery.

임플란트 가이드 수술을 위한 Planning 방식에 대한 고찰 (A procedure for the computer-guided implant planning: A narrative review)

  • 김종은;김남훈;박지현;심준성
    • 대한치과의사협회지
    • /
    • 제54권2호
    • /
    • pp.108-122
    • /
    • 2016
  • Prosthetic-driven implant placement is a concept considering the dental implant restoration first based on the final form of that prosthesis to be restored. The latest development of the imaging technology and digital dentistry was able to be obtained the high quality images of CBCT with low radiation exposure and it has also enabled the process to reconstruct the intraoral state in three dimensions due to the development of the intraoral, model and impression scanner. Computer-guided implant placement simulations and template production was able to be more widely used in this context. In this narrative review, the features and the types of implant surgical guides will be introduced. It will also be described the diagnosis and treatment plan using computerguided implant software to reduce the number of visit and to increase the accuracy of the implant surgery through the top-down approach based on the shape and location of the final prosthesis.

  • PDF

Computer-Assisted Mandibular Reconstruction with Monocortical DCIA Flap; A Case Report

  • Moon, Seong-Yong
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권2호
    • /
    • pp.83-86
    • /
    • 2015
  • Recently, computer-assisted surgery is popular for performing well-planned operations. Computer-aided navigation system is helpful in maxillofacial surgery with real time instrument positioning and clear anatomic identification. Generally, segmental mandibulectomy and reconstruction flap surgery have done by extra-oral approach such as, submandibular approach. This case report describes performing intra-oral segmental mandibulectomy and reconstruction with monocortical deep circumflex iliac artery (DCIA) flap and CT guided implant surgery by using computer-aided surgical guide and navigation for managing ameloblastoma in a 31 years old female patient.