• Title/Summary/Keyword: Guided Body

Search Result 146, Processing Time 0.024 seconds

A Study on the Motion Analysis of the Wire-guided Underwater Test Body in Natural Supercavitation (자연형 초공동화 운동체의 구속 직진운동 해석기법 연구)

  • Nah, Young-In;Kim, Sunbum
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.296-303
    • /
    • 2014
  • This paper describes the simplified simulation method of the wire-guided underwater test body with natural supercavitation. In this paper, the simulation based model of the wire-guided underwater body with natural supercavitation is proposed by using preceding research and commercial flow-analysis software. By using the model, the 1-dimensional wire-guided body motion in natural supercavitation can be solved very fast with reliability. The suggested model is validated by the comparison of simulation results with experimental data.

The Effect of Pleasant Guided Imagery on Vital Signs of Old Women (지시적 심상요법이 농촌노인의 활력증후에 미치는 효과)

  • Kim, Joo-Hyun;Kim, Sung-Jae;Kim, Hyang;Park, Mi-Jung;Lee, Dong-Suk
    • Journal of Korean Biological Nursing Science
    • /
    • v.8 no.1
    • /
    • pp.15-21
    • /
    • 2006
  • Purpose: The purpose of this study was to test the effect of pleasant guided imagery on the vital signs of elderly. Method: The subjects of this study were 15 elderly women. Collecting data were blood pressure, pulse rate, body temperature, the degree of imagination and relaxation. Data were analyzed using SPSS PC+ program with percentage, paired t-test. Result: After practicing of pleasant guided imagery, systolic blood pressure and pulse rate were significantly lowered than before practicing of pleasant guided imagery. After practicing of pleasant guided imagery, Diastolic blood pressure and body temperature were not significantly changed. After practicing of pleasant guided imagery, the degree of imagination and relaxation were relatively higher in old women. Conclusion: Pleasant guided imagery can be used for elderly patients with hypertension. And it can be used to promote relaxation of elderly with stress.

  • PDF

Comparative study on tissue responses of 3 resorbable membranes in rats (흡수성 차폐막의 조직반응에 관한 비교연구)

  • Hong, Seung-Bum;Kwon, Young-Hyuk;Lee, Man-Sup;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.475-488
    • /
    • 2002
  • The purpose of this study is to evaluate histologically the resorption and tissue response of various resorbable collagen membranes used for guided tissue regeneration and guided bone regeneration, using a subcutaneous model on the dorsal surface of the rat. In this study, 10 Sprague-Dawley male rats (mean BW 150gm) were used and the commercially available materials included acellular dermal matrix allograft, porcine collagen membrane, freeze-dried bovine dura mater. Animals were sacrificed at 2,6 and 8 weeks after implantation of various resorbable collagen membranes. Specimens were prepared with Hematoxylin-Eosin stain for light microscopic evaluation. The results of this study were as follows: 1. Resorption : Inner portion of porcine collagen membrane was resorbed a lot at 6 weeks, but its function was being kept for infiltration of another tissues were not observed. Freeze-dried bovine dura mater and acellular dermal allograft were rarely resorbed and kept their structure of outer portion for 8 weeks. 2. Inflammatory reactions : Inflammatory reaction was so mild and foreign body reaction didn't happen in all of resorbable collagen membranes, which showed their biocompatibility. 3. In all of resorbable collagen membranes, multinuclcated giant cells by foreign body reactions were not observed. Barrier membranes have to maintain their function for 4-6 weeks in guided tissue regeneration and at least 8 weeks in guided bone regeneration. According to present study, we can find all of the resorbable collagen membranes kept their function and structure for 8 weeks and were rarely resorbed. Foreign body reaction didn't happen and inflammatory reaction was so mild histologically. Therefore, all of collagen membranes used in this experiment were considered proper resorbable membranes for guided tissue regeneration and guided bone regeneration.

Free Vibration of Beams with a Guided Mass and an Elastic Spring Support (안내질량을 갖는 탄성지지된 보의 자유진동)

  • Ryu, Bong-Jo;Lee, Gyu-Seop;Lee, Jong-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.2
    • /
    • pp.176-184
    • /
    • 1996
  • The paper describes the vibration characteristics of the mechanical system consisting of a uniform Timoshenko beam with a guided mass and an elastic spring support. The free end of the beam does not rotate and the spring attatched to the guided mass is elastically restrained against translation. The guided mass is assumed to be a rigid body having a finite size, but not a mass point as it has been assumed so far. The effect of magnitudes, rotary inertia and the size of the guided mass on the vibration characteristics is fully investigated by the numerical simulation using FEM and experiment. In order to verify the eigenvalue sensitivity for considered system, comparison exact solutions with FEM is conducted, and a good agreement between two solutions is also highlighted.

  • PDF

In-House Developed Surface-Guided Repositioning and Monitoring System to Complement In-Room Patient Positioning System for Spine Radiosurgery

  • Kim, Kwang Hyeon;Lee, Haenghwa;Sohn, Moon-Jun;Mun, Chi-Woong
    • Progress in Medical Physics
    • /
    • v.32 no.2
    • /
    • pp.40-49
    • /
    • 2021
  • Purpose: This study aimed to develop a surface-guided radiosurgery system customized for a neurosurgery clinic that could be used as an auxiliary system for improving the accuracy, monitoring the movements of patients while performing hypofractionated radiosurgery, and minimizing the geometric misses. Methods: RGB-D cameras were installed in the treatment room and a monitoring system was constructed to perform a three-dimensional (3D) scan of the body surface of the patient and to express it as a point cloud. This could be used to confirm the exact position of the body of the patient and monitor their movements during radiosurgery. The image from the system was matched with the computed tomography (CT) image, and the positional accuracy was compared and analyzed in relation to the existing system to evaluate the accuracy of the setup. Results: The user interface was configured to register the patient and display the setup image to position the setup location by matching the 3D points on the body of the patient with the CT image. The error rate for the position difference was within 1-mm distance (min, -0.21 mm; max, 0.63 mm). Compared with the existing system, the differences were found to be as follows: x=0.08 mm, y=0.13 mm, and z=0.26 mm. Conclusions: We developed a surface-guided repositioning and monitoring system that can be customized and applied in a radiation surgery environment with an existing linear accelerator. It was confirmed that this system could be easily applied for accurate patient repositioning and inter-treatment motion monitoring.

Precise Tracking control of Automated Guided Vehicle System (무인반송 차량시스템의 정밀 추적제어)

  • Shin, Doo-Jin;Huh, Uk-Youl
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.7
    • /
    • pp.313-317
    • /
    • 2001
  • This paper proposed a fuzzy logic cross coupled controller which can enhance the path tracking performance of optically guided AGV(Automated Guided Vehicle). The AGV follows the guide path, it cannot be avoid the deviation from the path due to the inevitable error and the deviation must be corrected. Optically guided AGV used in industrial area is controlled by On-Off controller generally, the experimental AGV has three optical sensors in front body. In this structure, we could not know the leaving distance accurately and steering angle from the guided line, so AGV could not be controlled properly with conventional controller in the case of increasing or decreasing velocity. If we mount additional sensors the AGV, we could know the leaving distance and steering angle from the guided line and proper error compensating methode can be applied. But because cost of sensors are high, the cost of total system is increasing. So, in this paper, to improve the tracking performance of AGV which has the minimum number of sensors and fuzzy logic cross coupled controller is proposed. Some simulations and experimental results are presented to illustrate the performance of the proposed controller.

  • PDF

Body Stereotatic Radiosurgery Procedure of Base on Image Guided (Image Guided에 기초한 Body Stereotatic Radiosurgery의 과정)

  • Choi Yun-Kyeung;Lee Doo-Hyun;Cho Jung-Keun;Kim Jong-Won;Youm Doo-Seok;Kim Tae-Yoon;Choi Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.95-103
    • /
    • 2005
  • Purpose : In the radiosurgery, to obtain CT image to find more accurate tumor position during respiration, and using them, to increase the accuracy of radiation treatment by applying image guided. Materials and Methods : Using the self-made vacuum cushion for the body SRS, CT images were obtained three for each patient during respiration (shallow, inhalation, exhalation). They were transformed to the RTP computer and then were fused. Global GTVs were delineated on the fused images and more appropriated treatment planning was established. Results : We can find the tumor position is moving toward cranio-caudal with max 10 mm margin and volume is transformed. As a result from the comparision of DVH (pre & post radio surgery), we observed about 100% dose to tumor. Conclusion : BSRS was skeptical due to the tumor movement during respiration. More accurate by the combination of the development of immobilization devices and BSRS based on Image Guide, it will be applied to more cases for BSRS.

  • PDF

A Strength Analysis of the AGV Structure using the Finite Element Method (유한요소법을 이용한 AGV 구조물의 강도해석)

  • 양영수
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.3
    • /
    • pp.37-42
    • /
    • 1998
  • The important parts of the developing AGV model are the fabrication of each part and the design technology of body frame. In the present day, design of the body frame depends on the experience of the industrial place. the systematic data need for the optimal design of the frame for the case of model change. In this study, the strength of the early stage AGV(Automatic guided vehicle) is examined with the 3-dimensional finite elemnt method. In order to verify the finite element results, the computed results are compared with the experimental data from the strain-gage output. A New model was designed by rmoving some parts of the early staged(roughyly designed) model and choosing the thickness change of the rectangular-pipes.

  • PDF

A Study of the Safety Assessment for Combustion Products in the Exposure Human Bodies Rounding Missile Ejection (유도탄 사출시 연소 생성물의 인체 안전성 평가에 관한 연구)

  • Song, Kee Hyeok;Chung, Sung-Hak
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.4
    • /
    • pp.269-273
    • /
    • 2014
  • The objective of this study is to safety assessment for human body on the guided missile combustion products. This study is to verify the safety assessment when operating the interior missile ejection take on verify the safety of the human body. During the missile ejection of combustion products, this study is analyzed combustion products. Result are accepted NIOSH and KOSHA of the safe guideline, and 6 exposure gas to the specified values 42% (CO), 22% ($CO_2$), not detected (others) are within minimal exposures criteria of the reference value respectively. Contribution of these results supported that interior missile ejection during combustion products may have been ensured human safely. Therefore, the future for improving the environmental safety of the shooting projectile steel plate round, dust collector, ventilation and other facilities is to improve environmental safety and efficient renovated design needed by target focused areas.

Assessment of the Optic-guided Patient Positioning for Spinal Stereotactic Radiosurgery Using Novalis ExacTrac System (노발리스 ExacTrac system을 이용한 척추 정위 방사선수술 방법 평가)

  • 이동준;손문준;최광영;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.218-223
    • /
    • 2002
  • Stereotactic radiosurgery for intracranial lesion is well established since the Lars Leksell first introduced radiosurgery concept in 1951 Its use in the treatment of spinal lesion has been limited by the availability of effective immobilization devices. The first clinical experience of the spinal stereotactic radiosurgery technique was reported by Hamilton AJ. in 1995. Recently, Optic-guided patient positioning technique for extracranial stereotactic radiosurgery was developed and reported. This study is for assess the target positioning accuracy of the optic guided patient positioning system Exactrac (BrainLab., Inc, Germany). We have designed phantom for assess the accuracy of spinal stereotactic radiosurgery The infrared reflective body markers attached to the relatively immobile part of the body and a series of 2 mm CT images was taken. The image sets were transferred to the planning computer. During the radiosurgery treatment, we measure the real-time display showing the positioning values from Exactrac computer. And we compare the isocenter deviation from irradiated center point of the film which was mounted on the lesion site of the phantom and pin hole site of that film. The accuracy of the ExacTrac system in positioning a target point shows enough for the clinical applications.

  • PDF