• 제목/요약/키워드: Guide fin

검색결과 16건 처리시간 0.022초

환기용 축류팬의 가이드핀 블레이드 형상변화에 따른 유동특성에 관한 연구 (Effects of a Guide Fin Blade on the Flow Characteristics in a Ventilating Axial Fan)

  • 박홍광;이지근;노병준
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.874-882
    • /
    • 2007
  • The effects of a guide fin blade on the flow characteristics in a ventilating axial fan were investigated experimentally. The guide fins were setup onto the pressure surface of the blade, and their effects on the flowrate were evaluated. Two types of the guide fin blade were designed. One is the stem fin blade, and the other is the radial fin blade. The stem fin is designed normal to the circumference of a circle, and the radial fin is designed along the circumference of a circle. The results from the guide fin blade fans are compared with that of the blade without guide fins. The position and the geometry of the radial fin setting up on the blade have an effect on the increase of flowrate with the minor sacrifice of rotational speed of the blades. The radial fin positioning at 0.84 times blade diameter shows highest performance in the flowrate. The increase of the blade weight resulting from applying the guide fins shows minor effect on the variation of rotational speed of the blades.

가이드 베인을 부착한 핀-휜 유동에서 가이드 베인 위치와 입사각에 따른 전열 및 유동 특성에 관한 수치적 연구 (Numerical Study on the Effect of Guide Vane Position and Angle on Heat Transfer and Flow Characteristics of a Pin-fin Channel with a Guide Vane)

  • 이득호;오영택;배지환;이창형;김귀순
    • 한국추진공학회지
    • /
    • 제23권3호
    • /
    • pp.35-43
    • /
    • 2019
  • 본 연구에서는 핀-휜이 있는 유로에 위치와 유동 입사각이 다른 가이드 베인을 부착하여 전열 성능 및 압력 강하 특성 변화를 분석하였다. 레이놀즈수가 1400일 때 가이드 베인의 위치와 입사각에 따른 전열 성능과 유동 특성을 수치해석으로 확인하였고, 핀-휜 만 있는 해석 결과와 비교하였다. 수치해석을 수행한 결과, Case 1의 입사각 $0^{\circ}$일 경우에 전열 성능이 최대가 되고 핀-휜 만 있는 유로에 비해 약 5% 향상되었다. Case 2의 입사각 $10^{\circ}$일 경우에 압력 손실이 최소가 되고 약 1.9% 감소하였다.

핀-튜브에서 와류 발생기와 가이드 베인의 유동 및 전열 성능 특성에 관한 비교 연구 (A Comparative Study on the Flow and Heat Transfer Performance Characteristics of Vortex Generators and Guide Vane in Fin-Tube)

  • 배지환;오영택;이창형;이득호;김귀순
    • 항공우주시스템공학회지
    • /
    • 제14권3호
    • /
    • pp.1-9
    • /
    • 2020
  • 본 논문에서는 델타 윙렛 와류 발생기와 후퇴익형 와류 발생기 그리고 가이드 베인이 핀-튜브 유동에서의 압력 손실과 전열 성능에 미치는 효과를 비교하는 연구를 진행하였다. 와류 발생기와 가이드 베인은 채널 높이와 튜브의 지름을 기준으로 무차원화하였고, 위치는 저자들의 연구 결과에 따라 각각의 형상이 우수한 지점을 선정하였다. 레이놀즈 수는 입구 속도와 튜브 지름을 기준으로 하여 1400~8000으로 선정하였다. 결과적으로 압력 손실은 레이놀즈 수 8000에서 가이드 베인이 기존 핀-튜브 대비 4.7% 감소하는 효과를 보였고, 전열 성능은 레이놀즈 수 3800에서 델타 윙렛 와류 발생기가 기존 핀-튜브 대비 33% 정도 증가하는 결과를 확인하였다.

열전달 및 압력강하 특성을 고려한 채널 내 핀-휜 구조물의 설계 (Design of a Pin-Fin Structure in a Channel Considering the Heat Transfer and Pressure Drop Characteristics)

  • 신지영;손영석;이대영
    • 설비공학논문집
    • /
    • 제18권6호
    • /
    • pp.459-467
    • /
    • 2006
  • Rapid development of electronic technology requires small size, high density packaging and high power in the electronic devices, which results in more heat generation. Suitable heat dissipation is required to ensure the guaranteed performance and reliable operation of the current state-of-the-art electronic equipment. The aim of the present study is to find out the forced-convective thermal-hydraulic characteristics of a pin-fin heat exchanger as a candidate for cooling system of the electronic devices through the analysis and experiment. Various configuration of the pin-fin array is selected in order to find out the effect of spacing and diameter of the pin-fin on the heat transfer and pressure drop characteristics. Experimental results are compared with the analyses and correlations of several researchers. Finally, the design guide are provided for the required pressure drop and/or the heat transfer characteristics of the heat exchanger.

바이패스가 있는 히트 싱크의 열성능 최적화 (Thermal Optimization of a Straight Fin Heat Sink with Bypass Flow)

  • 김진욱;김상훈;김중년
    • 대한기계학회논문집B
    • /
    • 제34권2호
    • /
    • pp.179-184
    • /
    • 2010
  • 스트레이트 휜 히트 싱크가 장착된 공간에 팁 클리어런스(tip clearance)와 바이패스 유동이 열성능에 미치는 영향을 실험적으로 규명하고자 한다. 수평 및 수직 방향으로의 바이패스 유동에 의한 열성능 평가는 열식 질량 유량계(MFC)와 소형 풍동으로 이루어진다. 팁 클리어런스와 바이패스 유동에 의한 히트 싱크의 열성능은 열저항을 통하여 평가한다. 실험 결과, 스트레이트 휜 히트 싱크의 열저항은 팁 클리어런스가 증가함에 따라 점진적으로 증가하며, 유동 가이드 장치는 바이패스 유동을 감소하는 역할을 한다. 본 연구에서는 동일 유량 조건에서 히트 싱크의 입구에서 유동 가이드 장치까지의 거리에 따라 스트레이트 휜 히트 싱크의 최적값이 존재함을 확인하였다. 히트 싱크로 유입되는 유량이 증가함에 따라 유동 가이드 장치에 의한 열성능 개선 정도는 증가한다.

전산유체해석과 다구찌 방법을 연계한 공기 가열식 히터 시스템의 난방속효성 최적화에 관한 연구 (A Study on the Optimum Design of Warm-up rate in a Air-Heated Heater System by Using CFD Analysis and Taguchi Method)

  • 김민호
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.72-82
    • /
    • 2005
  • The objective of this paper is to describe the optimization of design parameters in a large-sized commercial bus heater system by using CFD(computational fluid dynamics) analysis and Taguchi method. In order to obtain the best combination of each control factor which results in a desired performance of heater system, the parameter design of the Taguchi method is adopted for the robust design considering the dynamic characteristic. The research activity may be divided into four phases. The first one is analyzing the problem, i.e., ascertaining the influential factors. In the second phase the levels were set in such a way that their variation would significantly influence the response. In the third phase the experimental runs were designed. In the final phase the planned runs were carried out numerically to evaluate the optimal combination of factors which is able to provide the best response. In this study, eight factors were considered for the analysis: one with two level and seven with three level combinations comprising the $L_{18}(2^1{\times}3^7)$ orthogonal array. The results of this study can be summarized as follows ; (i)The optimum condition of control factor is a set of <$A_2\;B_1\;C_3\;D_3\;E_1\;F_2\;G_3\;H_2$> where A is shape of the outer fin, B is pitch of the outer fin, C is height of the outer fin, D is the inner fin number, E is the inner fin height, F is length of the flame guide, G is diameter of the heating element and H is clearance between air guide and heating element. (ii)The heat capacity of heated discharge air under the optimum condition satisfies the equation y=0.6M w here M is a signal factor. (iii)The warm-up rate improves about three times, more largely as com pared with the current condition, which results in about 9.2minutes reduction.

Experimental studies and numerical analysis of the shear behavior of fin plates to tubular columns at ambient and elevated temperatures

  • Jones, M.H.;Wang, Y.C.
    • Steel and Composite Structures
    • /
    • 제8권3호
    • /
    • pp.179-200
    • /
    • 2008
  • This paper reports the results of a recent experimental study into the behavior of welded fin-plate connections to both hollow and concrete filled tubular (CFT) columns under shear. Experiments have been performed at both ambient and elevated temperatures with the aid of an electric kiln. The observed failure modes include fracture of the fin plate and tearing out of the tube around the welds. By considering the results of previously published research, the current design method for similar connections under purely tensile load, in CIDECT Guide 9, based on a deformation limit of 3% of the tube width is shown to be inadequate when evaluating the ultimate strength of such connections. By comparing the results from the current test program which failed in the fin-plate with Eurocode guidance for failure of a fin-plate alone under shear and bending load it is shown that the column face influences the overall connection strength regardless of failure mode. Concrete in-fill is observed to significantly increase the strength of connections over empty specimens, and circular column specimens were observed to exhibit greater strength than similarly proportioned square columns. A finite element (F.E.) model, developed using ABAQUS, is presented and validated against the experimental results in order that extensive parametric tests may be subsequently performed. When validating the model against elevated temperature tests it was found that using reduction factors suggested in published research for the specific steel grades improved results over applying the generic Eurocode elevated temperature steel strength reduction factors.

원형가이드 설치에 따른 충돌제트/유출냉각에서 열/물질전달 특성 (Heat/Mass Transfer for Impingement/Effusion Cooling System with Circular Guide)

  • 홍성국;조형희
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1147-1154
    • /
    • 2006
  • An experimental investigation was conducted to enhance the heat/mass transfer for impingement/effusion cooling system when the initial crossflow was formed. For the improvement of heat transfer, the circular guide is installed on the injection hole. At the fixed jet Reynolds number of 10,000, the measurements were carried out for blowing ratios ranging from 0.5 to 1.5. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The result presents that the circular guide protects the injected jet from the initial crossflow, increasing the heat/mass transfer. The heat transfer of stagnation region is hardly changed regardless of the blowing ratio. The secondary peak is obviously formed by flow transition to turbulent flow. At high blowing ratio of 1.5, the circular guide produces $26{\sim}30%$ augmentation on the averaged heat/mass transfer while the case without circular guide leads to the low and non-uniform heat/mass transfer. With the increased heat/mass transfer, the installation of circular guide is accompanied by the increase of pressure loss in the channel. However, the pressure drop caused by the circular guide is lower than that for other cooling technique with the circular pin fin.

감성 분석을 위한 FinBERT 미세 조정: 데이터 세트와 하이퍼파라미터의 효과성 탐구 (FinBERT Fine-Tuning for Sentiment Analysis: Exploring the Effectiveness of Datasets and Hyperparameters)

  • 김재헌;정희도;장백철
    • 인터넷정보학회논문지
    • /
    • 제24권4호
    • /
    • pp.127-135
    • /
    • 2023
  • 본 논문에서는 금융 뉴스 데이터로 추가적인 사전 학습이 진행된 BERT 기반 모델인 FinBERT 모델을 사용하여 금융 영역에서 감성 분석 시 학습시킬 데이터와 그에 맞는 하이퍼파라미터를 찾는 방법을 소개한다. 우리의 목표는 다양한 데이터 세트를 활용하고 하이퍼파라미터를 미세 조정하여 정확한 감성 분석을 위해 FinBERT 모델을 가장 잘 활용하는 방법에 대한 포괄적인 가이드를 제공하는 것이다. 이 연구에서는 제안된 FinBERT 모델 미세 조정 접근법의 아키텍처와 워크플로우를 개괄적으로 설명하고, 감성 분석 태스크를 위한 다양한 데이터 세트와 하이퍼파라미터의 성능을 강조한다. 또한, 감성 라벨링 작업에 GPT-3를 사용함으로써 GPT-3가 적절한 라벨러 역할을 하는지에 대한 신뢰성을 검증한다. 결과적으로 미세 조정된 FinBERT 모델이 다양한 데이터 세트에서 우수한 성능을 발휘 한다는 것을 보여주었고, 각 데이터 세트에 대해 전반적으로 우수한 성능을 보이는 학습률 5e-5와 배치 크기 64의 최적의 조합을 찾았다. 또 일반 도메인의 뉴스보다 일반 도메인의 트위터 데이터 세트에서 성능이 크게 향상됨을 기반으로 금융 뉴스 데이터만으로만 추가적으로 학습시키는 FinBERT 모델에 대한 의구심을 제시한다. 이를 통해 FinBERT 모델에 대한 최적의 접근 방식을 결정하는 복잡한 프로세스를 간소화하고 금융 분야 감성 분석 모델을 위한 추가적인 학습 데이터 세트와 미세 조정 시 하이퍼파라미터 선정에 대한 가이드라인을 제시한다.

가이드 핀 구조와 경계 파라미터가 폐열 회수용 열전발전 열교환기의 열적 성능에 미치는 영향 (Effect of Guide Fin Structures and Boundary Parameters on Thermal Performances of Heat Exchanger for Waste Heat Recovery Thermoelectric Generator)

  • 쿠날 산딥 가루드;서재형;이무연
    • 한국산학기술학회논문지
    • /
    • 제22권3호
    • /
    • pp.30-35
    • /
    • 2021
  • 본 연구는 다양한 가이드 핀 구조와 경계 파라미터가 폐열 회수 열전발전용 열교환기의 열적 성능에 미치는 영향에 대하여 다룬다. 가이드 핀 구조의 영향을 확인하기 위하여 ANSYS 19.1 소프트웨어를 사용하여 핀이 없는 유형, 삼각형 핀, 원형 핀, 원형 핀과 삼각 핀 조합 열교환기의 열전달율 및 압력 강하 특성을 수치해석 하였다. 원형 핀과 삼각 핀 조합 열교환기는 핀이 없는 열교환기, 원형 핀 또는 삼각 핀이 있는 원형 핀 또는 삼각 핀 열교환기와 비교하여 각각 27.0%, 5.2% 및 1.5% 높은 열전달율을 나타내었다. 그리고 복합 핀 열교환기의 압력강하는 핀이 없는 열교환기와 비교하여 28.3% 높았지만, 복합 핀 열교환기와 비교하여 9.2% 및 10.5% 낮은 압력강하 특성을 나타내었다. 최적모델로서 복합 핀 열교환기는 최대 고온 가스 및 냉각수 질량 유량, 최고 고온 가스 온도 그리고 최저 냉각수 온도 조건에서 최대 열전달율 5664.9 W 및 최대 압력강하 1454.02 Pa을 나타내었다.