• Title/Summary/Keyword: Group-view display

Search Result 30, Processing Time 0.025 seconds

Design of a See-through Off-Axis Head-Mounted-Display Optical System with an Ellipsoidal Surface

  • Wang, Junhua;Zhou, Qing;Chen, Jie;Hou, Lexin;Xu, Min
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.280-285
    • /
    • 2018
  • A new method to design a see-through off-axis head-mounted-display (OA-HMD) optical system with an ellipsoidal surface is proposed, in which a tilted ellipsoidal surface is used as the combiner, which yields the benefits of easier fabrication and testing compared to a freeform surface. Moreover, we realize a coaxial structure in the relay lens group, which is simple and has looser tolerance requirements, thus making assembly easier. The OA-HMD optical system we realize has a simple structure and consists of a combiner and 7 pieces of coaxial relay lenses. It has a $48^{\circ}{\times}36^{\circ}$ field of view (FOV) and 12-mm exit pupil diameter.

Volume Expansion of Ionic Liquids in the Presence of Supercritical Carbon Dioxide (초임계이산화탄소의 존재 하에서 이온성액체의 부피팽창)

  • Lim, Bang-Hyun;Shim, Jae-Jin
    • Clean Technology
    • /
    • v.14 no.4
    • /
    • pp.248-255
    • /
    • 2008
  • The volume expansion of three ionic liquids (ILs) in the presence of supercritical carbon dioxide has been measured at pressures up to 32 MPa and at temperatures from 313.15 to 333.15 K in a high-pressure view cell. The imidazolium-derivative ionic liquids 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim][$PF_6$]), 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][$BF_4$]), and 1-octyl-3-methylimidazolium tetrafluoroborate ([omim][$BF_4$]) were employed in this research. The effects of pressure, temperature, nature of anion and cation as well as the water content on the volume expansion of ILs by absorbing $CO_2$ were investigated experimentally. The volume expansion was higher for the ILs with longer cationic alkyl group and for the ILs with lower anion polarity. The lower the water content, the lower the temperature, or the higher the pressure, the higher was the expansion of IL phase.

  • PDF

J2.5dPathway: A 2.5D Visualization Tool to Display Selected Nodes in Biological Pathways, in Parallel Planes

  • Ham, Sung-Il;Song, Eun-Ha;Yang, San-Duk;Thong, Chin-Ting;Rhie, Arang;Galbadrakh, Bulgan;Lee, Kyung-Eun;Park, Hyun-Seok;Lee, San-Ho
    • Genomics & Informatics
    • /
    • v.7 no.3
    • /
    • pp.171-174
    • /
    • 2009
  • The characteristics of metabolic pathways make them particularly amenable to layered graph drawing methods. This paper presents a visual Java-based tool for drawing and annotating biological pathways in two- and a-half dimensions (2.5D) as an alternative to three-dimensional (3D) visualizations. Such visualization allows user to display different groups of clustered nodes, in different parallel planes, and to see a detailed view of a group of objects in focus and its place in the context of the whole system. This tool is an extended version of J2dPathway.

Change of Internal Resistance of OLED Devices during Operation

  • Lee, Soon-Seok;Hwang, Hak-Eun;Lim, Sung-Kyoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1443-1446
    • /
    • 2007
  • The luminance and operating voltage were measured during OLED operation for the purpose of analyzing the efficiency and change of internal resistance. The half lifetime of OLED was affected by degradation of OLED due to heat generated by ambient temperature and self heating. The operating voltage constantly increased due to the increase of internal resistance. The half lifetime of OLED driven by constant current source was found to be longer than that of the OELD driven by constant voltage and the reasons were clearly explained in this paper.

  • PDF

Dependence of Resistance and Capacitance of Organic light Emitting diode (OLED) on Applied Voltage

  • Lee, Soon-Seok;Im, Woo-Bin;Lim, Sung-Kyoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.446-449
    • /
    • 2008
  • Organic light emitting diodes (OLEDs) with multiple organic layers were fabricated to obtain and to evaluate an equivalent resistance and an equivalent capacitance of OLED device. The staircase voltage with an increasing period and a constant period was designed and applied to the OLED. The resistance of OLED was found to decrease from $270\;k{\Omega}$ to $2\;K{\Omega}$ as applied voltage increased after turn on. The equivalent capacitance of OLED maintained unchanged at low voltage level and deceased after showing peak value as the applied voltage increased.

  • PDF

Efficient Local Decoding Using Bit Stream Map for High Resolution Video (비트 스트림 지도를 이용한 고해상도 영상의 효율적인 지역복호화)

  • Park Sungwon;Won Jongwoo;Lee Sunyoung;Kim Wookjoong;Kim Kyuheon;Jang Euee S
    • Journal of Broadcast Engineering
    • /
    • v.9 no.4 s.25
    • /
    • pp.391-401
    • /
    • 2004
  • In this paper, we introduce a novel coding method to efficiently enable spatial random access for high resolution video. In terms of resolution and display size, standard display devices (such as cathode-ray tubes. monitors. PDAs, and LCDs) do not sufficiently support high resolution video such as digital cinema and panoramic video. Currently, users have no choice but to view video at lower resolution as a result of down-sampling, or only a partial region of the video due to display size limitations. Our proposed method. which we call the B-map, represents the set of starting locations of the coded segments in a picture frame. This information, or B-map, is first sent to the decoder prior to the coded data stream of the frame and is then used for fast local decoding. To test our method, we compare our B-map with JPEG tiling and the JPEG Resynchronization marker. Experimental results show that the proposed coding method requires less overhead than existing methods during the same decoding time. The results show promise for future panoramic or digital cinema applications.

The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT (PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.13-20
    • /
    • 2011
  • Purpose: The limited FOV(Field of View) of CT (Computed Tomography) can cause truncation artifact at external DFOV (Display Field of View) in PET/CT image. In our study, we measured the difference of SUV and compared the influence affecting to the image reconstructed with the extended DFOV. Materials and Methods: NEMA 1994 PET Phantom was filled with $^{18}F$(FDG) of 5.3 kBq/mL and placed at the center of FOV. Phantom images were acquired through emission scan. Shift the phantom's location to the external edge of DFOV and images were acquired with same method. All of acquired data through each experiment were reconstructed with same method, DFOV was applied 50 cm and 70 cm respectively. Then ROI was set up on the emission image, performed the comparative analysis SUV. In the clinical test, patient group shown truncation artifact was selected. ROI was set up at the liver of patient's image and performed the comparative analysis SUV according to the change of DFOV. Results: The pixel size was increase from 3.91 mm to 5.47 mm according to the DFOV increment in the centered location phantom study. When extended DFOV was applied, $_{max}SUV$ of ROI was decreased from 1.49 to 1.35. In case of shifted the center of phantom location study, $_{max}SUV$ was decreased from 1.30 to 1.20. The $_{max}SUV$ was 1.51 at the truncated region in the extended DFOV. The difference of the $_{max}SUV$ was 25.9% higher at the outside of the truncated region than inside. When the extended DFOV was applied, $_{max}SUV$ was decreased from 3.38 to 3.13. Conclusion: When the extended DFOV was applied, $_{max}SUV$ decreasing phenomenon can cause pixel to pixel noise by increasing of pixel size. In this reason, $_{max}SUV$ was underestimated. Therefore, We should consider the underestimation of quantitative result in the whole image plane in case of patient study applied extended DFOV protocol. Consequently, the result of the quantitative analysis may show more higher than inside at the truncated region.

  • PDF

Double-Gauss Optical System Design with Fixed Magnification and Image Surface Independent of Object Distance (물체거리가 변하여도 배율과 상면이 고정되는 이중 가우스 광학계의 설계)

  • Ryu, Jae Myung;Ryu, Chang Ho;Kim, Kang Min;Kim, Byoung Young;Ju, Yun Jae;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • A change in object distance would generally change the magnification of an optical system. In this paper, we have proposed and designed a double-Gauss optical system with a fixed magnification and image surface regardless of any change in object distance, according to moving the lens groups a little bit to the front and rear of the stop, independently parallel to the direction of the optical axis. By maintaining a constant size of image formation in spite of various object-distance changes in a projection system such as a head-up display (HUD) or head-mounted display (HMD), we can prevent the field of view from changing while focusing in an HUD or HMD. Also, to check precisely the state of the wiring that connects semiconductor chips and IC circuit boards, we can keep the magnification of the optical system constant, even when the object distance changes due to vertical movement along the optical axis of a testing device. Additionally, if we use this double-Gauss optical system as a vision system in the testing process of lots of electronic boards in a manufacturing system, since we can systematically eliminate additional image processing for visual enhancement of image quality, we can dramatically reduce the testing time for a fast test process. Also, the Gaussian bracket method was used to find the moving distance of each group, to achieve the desired specifications and fix magnification and image surface simultaneously. After the initial design, the optimization of the optical system was performed using the Synopsys optical design software.

Image Making As a Planning/Design Principle: A Case Study of Andong Municipal Museum Complex (AMMC)

  • Lee, Do Young
    • Architectural research
    • /
    • v.3 no.1
    • /
    • pp.21-27
    • /
    • 2001
  • This study addressing the underlying strategies for Andong municipal museum complex development is in timely view that Andong has obtained a worldwide reputation as a treasury of traditional Korean Confucian culture. Thus far, there has been a tendency that various local museums are proposed to meet architectural aspirations architects and users commonly hold. Overall, though, the major role they play in making overall city image has not been considered in a systematic manner. Based on Lee's (2001) two previous studies, this study summarized the utility of cognitive distance and cognitive map concepts, which are proposed by Kevin Lunch (1976) to evaluate city image, in planning Andong municipal museum complex (AMMC). Sample is stratified into city residents and outsiders, and also into the general public and design-related professionals to see if there is any group difference in constructing their mental image. Three major findings are obtained. First, familiarity, so-called the degree of knowing, is the function of the length of stay in a designated area. That is, the longer people stay in Andong, the more likely they are familiar with its overall environmental aspects. Second, mental proximity of Andong municipal museum complex relative to existing cultural landmarks is closely related to the degree of how people value those landmarks in terms of their significance. Dosan Seowon and Hahoe folk village are most highly valued, which means higher proximity. Third, functional diversity turned out to be the most important design dimension, while display mechanism are least valued. Cognitive simulations of this sort are meaningful in that projected composite image might be a rough first approximation of true public image.

  • PDF

Study on image quality improvement using Non-Linear Look-Up Table (비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구)

  • Kim, Sun-Chil;Lee, Jun-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF