• Title/Summary/Keyword: Group testing

Search Result 1,774, Processing Time 0.03 seconds

Fabrication of Mechanical fatigue flawed Specimen and Evaluation of Flaw Size (기계적 피로결함 시험편 제조 및 결함 크기 평가)

  • Hong, Jae-Keun;Kim, Woo-Sung;Son, Young-Ho;Park, Ban-Uk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.38-44
    • /
    • 2003
  • Performance demonstration with real flawed specimens has been strongly required for nondestructive evaluation of safety class components in nuclear power plant. Mechanical or thermal fatigue crack and intergranular stress corrosion cracking could be occured in the in-service nuclear power plant and mechanical fatigue crack was selected to study in this paper. Specimen was designed to produce mechanical fatigue flaw under tensile stress. The number of cycles and the level of stress were controlled to obtain the desired flaw roughness. After the accurate physical measurement of the flaw size and location, fracture surface was seal-welded in place to ensure the designed location and site. The remaining weld groove was then filled by using gas-tungsten are welding(GTAW) and flux-cored arc welding(FCAW). Results of radio graphic and ultrasonic testing showed that fatigue cracks were consistent with the designed size and location in the final specimens.

Evaluation of Sample Testing Scheme for Designated Aquatic Animals (수산동물 지정검역물에 대한 표본검사 계획 검토)

  • Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.58-62
    • /
    • 2012
  • To protect aquatic animal health of importing countries from the potential risks associated with exotic diseases introduced through international trade of live aquatic animals, inspection of designated commodities at ports of entry is a critical component of the safeguarding system. The only way to be 100% confident that no fishes in a shipment are infected with a specific agent is to test every fish in the commodity imported with a perfect diagnostic test. For the majority of cases, this is unrealistic since the group of interest may very large particularly for aquatic animals, or imperfect tests are often available. It is, therefore, more common to test a fixed proportion of a group by preplanned sampling schemes. However, decision making based on results of testing the sample can provide quite a chance that infected groups may be misclassified as uninfected, depending on sampling strategy employed. The objective of this study was to determine the possibility that one or more fishes in the group imported being infected but tests negative after inspecting samples. This question is critical to government authorities to examine whether sampling plan is sufficient to achieve the purpose intended for. At fixed population size, the maximum number of infected fishes when all tests negative was decreased as the sampling fraction increased. The probability of including at least one undetected but infected fish in a group for negative tests increased with the number of fish tested or true prevalence. The risk was much lesser where high sensitivity test was assumed; when increasing test sensitivity from 0.9 to 0.99, this risk was dramatically reduced to about a tenth or a fourth for prevalence ranges from 2 to 10%, given sample size ranges from 10 to 200. Based on the preliminary analysis, the author concluded that current sampling plan testing 4-8% of the import proposal for human consumption still can yield high false negative results. Therefore, from the quarantine inspection point of view, an enforced commodity-specific sampling design that accounts for the cost of testing with an imperfect test at the specified design prevalence is urgent.

Development of MFL Testing System for the Inspection of Storage Tank Floor (저장탱크 바닥면 검사를 위한 누설자속 탐상 시스템 개발)

  • Won, Soon-Ho;Cho, Kyung-Shik;Lee, Jong-O;Chang, Hong-Keun;Joo, Gwang-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.38-44
    • /
    • 2002
  • MFL method is a qualitative inspection tool and is a reliable, fast and economical NDT method. The application of MFL method to the inspection of storage tank floor plates has been shown to be a viable means. Examination of tank floors previously depended primarily upon ultrasonic test methods that required slow and painstaking application. Therefor most ultrasonic inspection of storage tank has been limited to spot testing only. Our NDE group have developed magnetic flux leakage system to overcome limitation of ultrasonic test. The developed system consists of magnetic yoke, array sensor, crawler and software. It is proved that the system is able to detect artificial flaw like 3.2mm diameter, 1.2mm depth in 6mm thick steel plate.

Acute and Subchronic Inhalation Toxicity of n-Octane in Rats

  • Sung, Jae-Hyuck;Choi, Byung-Gil;Kim, Hyeon-Yeong;Baek, Min-Won;Ryu, Hyun-Youl;Kim, Yong-Soon;Choi, Young-Kuk;Yu, Il-Je;Song, Kyung-Seuk
    • Safety and Health at Work
    • /
    • v.1 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Objectives: We have investigated the toxic effects of the inhalation of subchronic and acute levels of n-octane. Methods: The rats were exposed to n-octane of 0, 2.34, 11.68 and 23.36 mg/L (n = 5 rats/group/gender) in an acute inhalation test (Organization for Economic Co-operation and Development (OECD) TG 403), or to 0, 0.93, 2.62 and 7.48 mg/L (n = 10 rats/group/gender) for a subchronic inhalation test (OECE TG 413), to establish a national chemical management system consistent with the Globally Harmonized Classification System (GHS). Results: Acutely-exposed rats became lethargic but recovered following discontinuation of inhalation. Other clinical symptoms such as change of body weight and autopsy finds were absent. The LC50 for the acute inhalation toxicity of n-octane was determined to exceed 23.36 mg/L and the GHS category was 'not grouping'. Subchronically-treated rats displayed no significant clinical and histopathological differences from untreated controls; also, target organs were affected hematologically, biochemically and pathologically. Therefore, the no observable adverse effect level was indicated as exceeding 7.48 mg/L and the GHS category was 'not grouping' for the specific target organ toxicity upon repeated exposure. Conclusion: However, n-octane exposure should be controlled to be below the American Conference of Industrial Hygienists recommendation (300 ppm) to prevent inhalation-related adverse health effects of workers.

Current Uses and Research Activity Regarding Non-testing Methods Including (Q)SARs in Various Chemical Regulatory Programs (국외 화학물질 관리 제도 내에서의 (Q)SARs 및 비-시험 방법 사용과 관련 연구 현황)

  • Ha, Mi-Hee;Kim, Sang-Hun
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.261-270
    • /
    • 2009
  • To make measurable regulatory decisions of chemicals, it is necessary to consider their effect on the human health and ecosystem. In principle, this is based on relevant toxicity studies conducted by accepted guidelines. However, current regulatory programs in various countries confront challenges related to risk assessment of large numbers of chemicals within the restricted resources and time. Therefore there is a need for more efficient approach to limit the number of tests to be conducted. This promotes the development of powerful nontesting methods (e.g. (Q)SARs) and permits to use the predicted data for regulatory purpose. In this article, current status of non-testing methods in various chemical regulatory programs was reviewed in terms of their application and research activity on them. Finally, their usefulness associated with development of domestic regulatory program was suggested.

Android App Reuse Analysis using the Sequential Hypothesis Testing

  • Ho, Jun-Won
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.8 no.4
    • /
    • pp.11-18
    • /
    • 2016
  • Due to open source policy, Android systems are exposed to a variety of security problems. In particular, app reuse attacks are detrimental threat to the Android system security. This is because attacker can create core malign components and quickly generate a bunch of malicious apps by reusing these components. Hence, it is very imperative to discern whether Android apps contain reused components. To meet this need, we propose an Android app reuse analysis technique based on the Sequential Hypothesis Testing. This technique quickly makes a decision with a few number of samples whether a set of Android apps is made through app reuse. We performed experimental study with 6 malicious app groups, 1 google and 1 third-party app group such that each group consists of 100 Android apps. Experimental results demonstrate that our proposed analysis technique efficiently judges Android app groups with reused components.

[ $SRV^{(R)}$ ]-Testing of the Tribosystem Piston Ring and Cylinder Liner Outside the Engine

  • Woydt Mathias;Ebrecht Johannes
    • KSTLE International Journal
    • /
    • v.6 no.2
    • /
    • pp.58-64
    • /
    • 2005
  • An OEM driven working group started in January 2004 to elaborate the philosophies, concepts and test procedures for testing piston ring and cylinder liner materials as well as engine oils outside the engine using the $SRV^{(R)}$ test equipment. The different $SRV^{(R)}$ test philosophies in use by OEMs are compiled. The working group focuses on a.) ASTM sequence VIB (Fuel economy by aging oils), b.) friction and wear in the top dead region under mixed/boundary lubrication, c.) extreme pressure load under mixed/boundary lubrication and d.) hydrodynamic friction. Tribological test result and precision data are presented.

Study on the performance verification of IEC 61850 communication service on domestic IEDs (국내 IED 시작품대상 IEC 61850 통신서비스 성능 검증에 관한 연구)

  • Lee, N.H;Jang, B.T.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.3-5
    • /
    • 2008
  • Korea Electric Power Research Institute has being carried out an IEC 61580 based communication service test on domestic IED trial products developed related to power IT project. This paper describes IEC 61850-10 conformance test and testing items established by UCA international Users Group and this study is on the analysis of testing results from IED communication service with selected testing blocks, which consist of Basic association, Dataset, Reporting and GOOSE.

  • PDF

The Effects of Environmental Issue Analysis Instruction on Elementary School Students' Environmental Decision Making Ability (환경쟁점분석 수업이 초등학생의 환경의사결정 능력에 미치는 영향)

  • Min, Eun-Hang;Choi, Dan-Hyung
    • Hwankyungkyoyuk
    • /
    • v.20 no.1
    • /
    • pp.90-105
    • /
    • 2007
  • The purpose of this study is to find the influence of environmental issue analysis instruction on the environmental decision making ability for grade 5 elementary school students. The study was done through pre and post testing control group structure. The object of this study is grade 5 of I elementary school students which were divided into 35 student test group and 54 student control group. Through studying references, the selection standard of appropriate environment issue and the environmental issue analysis instructing objective. Conducted the environment issue instructing based on the selected environment issue and instructing objective. The classes were held in total of 6 sessions in the chapters related to class objective and class content within the curriculum. The pre and post testing was done using environment decision making ability test sheet which was reconstructed by myself and the results were analyzed by t-test. As a result of comparing pre and post testing the students in test group showed significant results in the processes of problem recognition, evaluation of alternatives, behave planing (p<.001). As a result of comparing the differences of environment decision making ability of pre and post test of test group and control group, it showed significant results in the process of evaluation of alternatives(p<.00l). The environment issue analysis class has positive influence on the environment decision making abilities of the students but since the outcome of environment decision making ability is lower, there is a need for long term environment education plan and further studies to find whether the environment issues within the textbook is appropriate in the elementary student level, useful school aspect and the influence of environment issue analysis class on the change of values for individuals.

  • PDF

Environmental Testing for Precision Parts and Instruments (정밀부품 및 기기에 대한 환경시험기술)

  • Choi, Man-Yong;Park, Jeong-Hak;Yun, Kyu-Tek
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.642-649
    • /
    • 2001
  • Precision parts and instruments are tested to evaluate performance in development-process and product-step to prement a potential defect due to a failure design. In this paper, Environmental test technology, which is the basis of reliability analysis, is introduced with examples of test criterion, test method for products, encoder and traffic signal controller, and measuring instruments. Recently, as the importance of the environmental test technology is recognised. It is proposed that tranining of test technician and technology of jig design and failure analysis are very essential.

  • PDF