• Title/Summary/Keyword: Group testing

Search Result 1,796, Processing Time 0.023 seconds

Cervical spine reconstruction after total vertebrectomy using customized three-dimensional-printed implants in dogs

  • Ji-Won Jeon;Kyu-Won Kang;Woo-Keyoung Kim;Sook Yang;Byung-Jae Kang
    • Journal of Veterinary Science
    • /
    • v.25 no.1
    • /
    • pp.2.1-2.14
    • /
    • 2024
  • Background: Sufficient surgical resection is necessary for effective tumor control, but is usually limited for vertebral tumors, especially in the cervical spine in small animal neurosurgery. Objective: To evaluate the primary stability and safety of customized three-dimensional (3D)-printed implants for cervical spine reconstruction after total vertebrectomy. Methods: Customized guides and implants were designed based on computed tomography (CT) imaging of five beagle cadavers and were 3D-printed. They were used to reconstruct C5 after total vertebrectomy. Postoperative CT images were obtained to evaluate the safety and accuracy of screw positioning. After harvesting 10 vertebral specimens (C3-C7) from intact (group A) and implanted spines (group B), implant stability was analyzed using a 4-point bending test comparing with groups A and C (reconstituted with plate and pins/polymethylmethacrylate after testing in Group A). Results: All customized implants were applied without gross neurovascular damage. In addition, 90% of the screws were in a safe area, with 7.5% in grade 1 (< 1.3 mm) and 2.5% in grade 2 (> 1.3 mm). The mean entry point and angular deviations were 0.81 ± 0.43 mm and 6.50 ± 5.11°, respectively. Groups B and C significantly decreased the range of motion (ROM) in C3-C7 compared with intact spines (p = 0.033, and 0.018). Both groups reduced overall ROM and neutral zone in C4-C6, but only group B showed significance (p = 0.005, and 0.027). Conclusion: Customized 3D-printed implants could safely and accurately replace a cervical vertebra in dog cadavers while providing primary stability.

Evaluation of the Remineralization Capacity of Water-based Silver Fluoride

  • Gwangsuk Kim;Juhyun Lee;Haeni Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.80-87
    • /
    • 2024
  • Silver diamine fluoride, which can arrest dental caries, is alkaline and may cause mild soft tissue irritation. Water-based silver fluoride has a neutral pH, which is closer to the physiological range, and is biocompatible for use in the oral environment. This study aimed to evaluate the effect of water-based silver fluoride on remineralizing early enamel lesions by comparing it with other fluoride agents through microhardness and quantitative light-induced fluorescence measurements. An in vitro study with intact bovine incisors was performed. Artificial enamel lesions were induced and subjected to microhardness and quantitative light-induced fluorescence testing. Specimens were randomly divided into 4 groups for treatment. The specimens in group I were treated with water-based silver fluoride and potassium iodide, group II with silver diamine fluoride and potassium iodide, group III with sodium fluoride varnish, and group IV with distilled water. After 8 days of pH cycling, the specimens were subjected to microhardness and quantitative light-induced fluorescence testing. Water-based silver fluoride and silver diamine fluoride showed the greatest increases in microhardness and quantitative light-induced fluorescence, with no significant differences between the two. Sodium fluoride varnish also exhibited a significant increase in microhardness and quantitative light-induced fluorescence, but the differences were smaller than those for water-based silver fluoride and silver diamine fluoride. Water-based silver fluoride is considered useful in a clinical setting for remineralizing enamel lesions, with the advantages of no risk of tissue burn and improved taste and smell.

Effect of Wrist Resistance Training on Motor Control and Strength in Young Males

  • Kim, You-Sin;Kim, Dae-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.309-315
    • /
    • 2014
  • The aim of the present study was to investigate the effects of 6-week wrist resistance training on wrist torque control. Nineteen subjects were randomly assigned to either the wrist training group (n=9) or the control group (n=10). The training group performed wrist exercises for six directions (flexion, extension, pronation, supination, radial deviation, and ulnar deviation) while the control group did not. Testing for the isometric torque control error, one-repetition maximum (1-RM) strength, and isokinetic maximum torque (angular velocity of $60^{\circ}/s$ wrist movements) were conducted before and after six weeks of resistance training and after every two-week interval of training. The wrist training group showed significant decreases in isometric torque control error in all six directions after the 2-week resistance training, while the control group did not show significant increase or decrease. The training group showed significant increases in the maximum strength in all six directions assessed by 1-RM strength and isokinetic strength tests after the 4-week resistance training, while the control group did not show any statistically significant changes. This study shows that motor control ability significantly improves within the first two weeks of resistance training, while the wrist strength significantly improves within the first four weeks of resistance training in wrist training group compared to the control.

A STUDY ON THE BOND STRENGTH OF REPAIRED GLASS IONOMER CEMENTS (Repaired glass ionomer cement의 결합강도에 관한 연구)

  • Seo, Su-Jeong;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.347-355
    • /
    • 1996
  • The purpose of this study was to compare the bond strengths of different kinds of glass ionomer cements (GIC), which is recently increasing the clinical application in the field of pediatric dentistry and measure the repaired bond strengths in order to examine the clinical applicabilty of partial repaired cases. By using one kind of the light cured type GIC and three kinds of the chemical cured type GIC, the bond strengths of the followings were compared : unrepaired group as control, repaired conditioning group, which was treated the repaired surface using 25% polyacrylic acid and repaired non-conditioning group without surface treatment. Three point bending test was performed under Universal Testing Machine in order to measure the compressive bond strengths. The results were as follows : 1. Light cured GIC had higher bond strength than chemical cured type GIC in both of repaired and unrepaired groups. 2. In repaired cases, all of the materials decreased the bond strength when compared to the control group. In the light cured type, the bond strength of repaired conditioning group decreased 31.6%, repaired non-conditioning group decreased 40.8%. In chemical cured types, the bond strength of repaired conditining group decreased 11.8%, repaired non-conditioning group decreased 20.9%. 3. All the materials, in the case of the chemical treatment on the repaired surface using 25% polyacrylic acid had higher bond strength than untreated but, lower than control group.

  • PDF

VCUG Studies on the Clinical Usefulness of Aids (VCUG 보조기구의 임상적 유용성에 관한 고찰)

  • Choe, Dea yeon;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.529-533
    • /
    • 2015
  • VCUG(Voiding Cystourethrography) study is being performed to check urinary reflex symptom from bladder to ureter or kidney in the method of filling the bladder with radiation opaque contrast agent. However, VCUG study have been performed impersonally, patients have to be naked and open their legs and then void. This method is so impersonal that it is immediately needed to improve the way of testing and crete new aid. Therefore, this study through producing underwear for VCUG, analysis and compares the test time of VCUG, patient radiation dose and patient satisfaction. The target of this study was 79 Male and Female patients who visited genitourinary clinic of PNUYH for their VCUG tests AXIUM Iconos R200(Siemens Medical System : Germany) and self-produced plastic underwears made by vinyl and plasic molding machine were used. The 79 patient were divided into two groups : experiment of patient and comparison group of we patient (using aid) in order to compare, testing time, DAP (dose area product) and patient satisfaction. There was time reduction, from 35.3min of comparison group to 27.8min experimentation group by 7.5min decrease. And comparison group of $4566.6{\mu}Gym^2$(DAP) decreased experimental group (using aid) of $3411.9{\mu}Gym^2$ by $1154.7{\mu}Gym^2$. In the case of patients satisfaction study, anxiety had a drop by 3.45 of comparison group to 2.51 experimentation group by 0.94 decrease. in experimental group. And shame had a drop by 4.02 of comparison group to 3.08 experimentation group by 0.94 increase. in experimental group. Difference of the smooth voiding had a drop by 1.90 of comparison group to 2.84 experimentation group by 0.94 increase. in experimental group. In addition satisfaction had a rise by 1.19 in experimental group. There were also other opinions of uncomfortableness on it and troublesome to wear. VCUG is one of the sensitive care required test. Therefore staff and the aid can give patients such comfortable and the aid can consentive on voiding. As a result test time and DAP can be reduced. It is needed to make testing at more comfortable for patients.

Correlation Analysis between Ultrasonic Parameters and Elastic Modulus of Apple

  • Kim, Ghi-Seok;Kim, Ki-Bok;Park, Jeong-Gil;Lee, Sang-Dae;Jung, Hyun-Mo;Kim, Man-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.3
    • /
    • pp.279-284
    • /
    • 2008
  • The firmness of fruit is one of the most important quality factors and is highly correlated to the elastic modulus. In this study, the ultrasonic transmission method was applied to evaluate the elastic modulus of the apple. In order to transmit and receive the ultrasonic wave through the whole apple, the ultrasonic measurement setup consisted of ultrasonic pulser, two specially fabricated ultrasonic transducers for fruit and digital storage oscilloscope. Ultrasonic parameters such as ultrasonic wave velocity, apparent attenuation, and peak frequencies were analyzed. The elastic modulus of apple was measured by using compression test apparatus. The correlations between ultrasonic parameters and elastic modulus were analyzed. A multiple linear regression model describing the relationship between elastic modulus and ultrasonic parameters was proposed.

The effect of zirconia surface architecturing technique on the zirconia/veneer interfacial bond strength

  • Her, Soo-Bok;Kim, Kyoung Hun;Park, Sang Eun;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.259-264
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the effect of the zirconia surface architecturing technique (ZSAT) on the bond strength between veneering porcelain and zirconia ceramic. MATERIALS AND METHODS. 20 sintered zirconia ceramic specimens were used to determine the optimal surface treatment time, and were randomly divided into 4 groups based on treatment times of 0, 1, 2, and 3 hours. After etching with a special solution, the surface was observed under scanning electron microscope, and then the porcelain was veneered for scratch testing. Sixty 3 mol% yttria-stabilized tetragonal zirconia polycrystal ceramic blocks were used for tensile strength testing; 30 of these blocks were surface treated and the rest were not. Statistical analysis was performed using ANOVA, the Tukey post-hoc test, and independent t-test, and the level of significance was set at ${\alpha}=.05$. RESULTS. The surface treatment of the zirconia using ZSAT increased the surface roughness, and tensile strength test results showed that the ZSAT group significantly increased the bond strength between zirconia and veneering porcelain compared to the untreated group (36 MPa vs. 30 MPa). Optimal etching time was determined to be 2 hours based on the scratch test results. CONCLUSION. ZSAT increases the surface roughness of zirconia, and this might contribute to the increased interfacial bond strength between zirconia and veneering porcelain.

The Effect of Dispersion Relations on the Determination of Surface Acoustical Wave Velocity (주파수 의존성이 표면탄성파의 속도 결정에 미치는 영향)

  • Kwon, Sung-D.;Yoon, Seok-S.;Lee, Seung-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.340-346
    • /
    • 1999
  • Minimum reflection and backward radiation methods on liquid/solid interrace were used to determine the velocity dispersion relation of acoustical surface wave for brass and aluminum substrates and copper/stainless steel nickel/brass, and nickel/aluminum layered substrates. Dispersion data agreed to dispersion characteristics of a generalized Lamb wave. The difference between velocities determined by two phenomena was closely related to the dispersion characteristics. This correspondence was explained by considering the generation mechanism of surface waves and the concept of group velocity.

  • PDF

Nondestructive Evaluation Using Electromagnetic-Acoustic Transducer (Electromagnetic-Acoustic Transducer를 이용한 비파괴평가)

  • Ahn, Bong-Young;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.4
    • /
    • pp.278-284
    • /
    • 1997
  • EMAT는 비접촉으로 초음파를 송수신 할 수 있는 탐촉자로서 시험체와 탐촉자간의 접촉을 위한 매개 물질이 필요치 않으므로, 움직이고 있는 물체에 초음파탐상법을 적용하고자 하는 분야와 초음파의 속도를 정밀하게 측정하고자 하는 분야에 주로 응용된다. 구체적으로는 길이가 긴 튜브류의 결함 탐상, 용접중인 재료의 용접상태 감시, 기차바퀴 및 레일의 결함 탐상, 고온상태인 재료의 결함 탐상 등이 비접촉 특성을 이용하여 적용될 수 있는 분야이며, 재료의 집합조직 및 소성이방성의 측정, 재료의 미세조직 및 기계적 강도의 예측, 그리고 잔류응력의 측정 등이 정밀한 초음파속도 및 감쇠의 측정으로부터 적용될 수 있는 분야이다. EMAT가 일반적인 접촉식초음파탐상법에 비하여 특별한 분야에의 응용에 큰 장점을 가지고 있지만, 낮은 에너지 전환효율, 넓은 불감영역, 그리고 사용주파수의 한계 등의 문제를 가지고 있기 때문에 기존의 접촉식 방법의 적용이 용이한 분야에의 적용은 필요하지 않다. 그러나 특별한 목적과 용도에의 적용 필요성이 생길 경우에는 적절한 연구를 통하여 알맞은 탐촉자를 제작하고 탐상 방법을 개발함으로서 본래의 목적에 알맞은 탐상이 수행될 수 있다.

  • PDF

The effects of circadian disturbances induced by night shifts on the mouse peripheral tissues

  • Seo, Dong-Hyun;Kim, Han-Sung;Ko, Chang-Yong;Schreiber, Jurgen;Jang, Yeong-Su;Bae, Kiho
    • Animal cells and systems
    • /
    • v.16 no.5
    • /
    • pp.357-365
    • /
    • 2012
  • We have examined the effect of circadian disturbances induced by night shifts (NSs) on the phenotypes of the tibiae and abdominal adipose tissues (ADTs) in a mouse model by using in vivo micro-computed tomography (micro-CT). We found that the volumes of total and visceral ADTs in the night-shifted group of mice were significantly larger (69 and 92%, respectively) than those in the control. The mean polar moment of inertia, cross-sectional thickness, and bone mineral density of the cortical bone in the night-shifted group of mice were less (13, 5, and 3%, respectively) than those in the control. Moreover, the volume and the thickness of growth plates (GPs) of the tibiae in the night-shifted mice were significantly smaller (22 and 20%, respectively) than those in the control. Taken together, our results indicate that disturbances in the mouse circadian rhythms induced by NSs affect the morphological characteristics of cortical bone, the volume and the thickness of GPs, and the volume of ADTs.