• Title/Summary/Keyword: Group testing

Search Result 1,796, Processing Time 0.028 seconds

Studies on Varietal Resistance to Sheath Blight Disease in Rice II. Varietal Difference of Resistance (벼 품종의 잎집무늬마름병 저항성 연구 II. 품종간 저항성의 차이)

  • Kim, Kwang-Ho;Yang, Kae-Jin;Lee, Sang-Bok
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.32 no.3
    • /
    • pp.302-309
    • /
    • 1987
  • One hundred rice varieties were tested for their level of resistance to sheath blight disease at adult plant stage in field condition through 1984 to 1986. Rice plants were grown under ordinary seasonal culture and inoculated by k-2 fungus isolate during three years. k -1 isolate was also inoculated separately in 1984 and test under late seasonal culture was conducted in separate field in 1985. Degree of damage by the disease observed at 25 days after heading was used to identify the level of resistance of the rice varieties tested. Varietal differences of degree of damage were significant in five tests during three years, and the genotypic variance of degree of damage was always higher than environmental variance among varieties tested. Positive correlations between testing years, between cultural seasons, and between isolates inoculated were found in degree of damage of varieties tested for two or three years continuously. Degree of damage by the disease was correlated negatively with heading date of rice varieties except 1984 tests. Thus, the level of resistance should be compared among the variety group having almost same heading date in field condition, and late and extremely late variety groups should be tested for their level of resistance under appropriate environmental condition. Gayabyo, an early heading variety, and SR9713-54-3, a medium heading breeding line, showed consistent lower value of degree of damage during two or three years. These two varieties were selected as moderate resistant germplasm.

  • PDF

Investigating Organ Toxicity Profile of Tenofovir and Tenofovir Nanoparticle on the Liver and Kidney: Experimental Animal Study

  • Peter, Aniekan Imo;Naidu, Edwin CS;Akang, Edidiong;Ogedengbe, Oluwatosin O;Offor, Ugochukwu;Rambharose, Sanjeev;Kalhapure, Rahul;Chuturgoon, Anil;Govender, Thirumala;Azu, Onyemaechi O
    • Toxicological Research
    • /
    • v.34 no.3
    • /
    • pp.221-229
    • /
    • 2018
  • Tenofovir nanoparticles are novel therapeutic intervention in human immunodeficiency virus (HIV) infection reaching the virus in their sanctuary sites. However, there has been no systemic toxicity testing of this formulation despite global concerns on the safety of nano drugs. Therefore, this study was designed to investigate the toxicity of Tenofovir nanoparticle (NTDF) on the liver and kidney using an animal model. Fifteen adult male Sprague-Dawley (SD) rats maintained at the animal house of the biomedical resources unit of the University of KwaZulu-Natal were weighed and divided into three groups. Control animals (A) were administered with normal saline (NS). The therapeutic doses of Tenofovir (TDF) and nanoparticles of Tenofovir (NTDF) were administered to group B and C and observed for signs of stress for four weeks after which animals were weighed and sacrificed. Liver and kidney were removed and fixed in formal saline, processed and stained using H/E, PAS and MT stains for light microscopy. Serum was obtained for renal function test (RFT) and liver function test (LFT). Cellular measurements and capturing were done using ImageJ and Leica software 2.0. Data were analysed using graph pad 6, p values < 0.05 were significant. We observed no signs of behavioural toxicity and no mortality during this study, however, in the kidneys, we reported mild morphological perturbations widening of Bowman's space, and vacuolations in glomerulus and tubules of TDF and NTDF animals. Also, there was a significant elevation of glycogen deposition in NTDF and TDF animals when compared with control. In the liver, there were mild histological changes with widening of sinusoidal spaces, vacuolations in hepatocytes and elevation of glycogen deposition in TDF and NTDF administered animals. In addition to this, there were no significant differences in stereological measurements and cell count, LFT, RFT, weight changes and organo-somatic index between treatment groups and control. In conclusion, NTDF and TDF in therapeutic doses can lead to mild hepatic and renal histological damage. Further studies are needed to understand the precise genetic mechanism.

A Study on High Speed Laser Welding by using Scanner and Industrial Robot (스캐너와 산업용 로봇을 이용한 고속 레이저 용접에 관한 연구)

  • Kang, Hee-Shin;Suh, Jeong;Kim, Jong-Su;Kim, Jeng-O;Cho, Taik-Dong
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.29-29
    • /
    • 2009
  • On this research, laser welding technology for manufacturing automobile body is studied. Laser welding technology is one of the important technologies used in the manufacturing of lighter, safer automotive bodies at a high level of productivity; the leading automotive manufacturers have replaced spot welding with laser welding in the process of car body assembly. Korean auto manufacturers are developing and applying the laser welding technology using a high output power Nd:YAG laser and a 6-axes industrial robot. On the other hand, the robot-based remote laser welding system was equipped with a long focal laser scanner system in robotic end effect. Laser system, robot system, and scanner system are used for realizing the high speed laser welding system. The remote laser welding system and industrial robotic system are used to consist of robot-based remote laser welding system. The robot-based remote laser welding system is flexible and able to improve laser welding speed compared with traditional welding as spot welding and laser welding. The robot-based remote laser systems used in this study were Trumpf's 4kW Nd:YAG laser (HL4006D) and IPG's 1.6kW Fiber laser (YLR-1600), while the robot systems were of ABB's IRB6400R (payload:120kg) and Hyundai Heavy Industry's HX130-02 (payload:130kg). In addition, a study of quality evaluation and monitoring technology for the remote laser welding was conducted. The welding joints of steel plate and steel plate coated with zinc were butt and lapped joints. The quality testing of the laser welding was conducted by observing the shape of the beads on the plate and the cross-section of the welded parts, analyzing the results of mechanical tension test, and monitoring the plasma intensity and temperature by using UV and IR detectors. Over the past years, Trumf's 4kW Nd:YAG laser and ABB's IRB6400R robot system was used. Nowadays, the new laser source, robot and laser scanner system are used to increase the processing speed and to improve the efficiency of processes. This paper proposes the robot-based remote laser welding system as a means of resolving the limited welding speed and accuracy of conventional laser welding systems.

  • PDF

A Study on Interoperability of Geo-sensor Based Outcomes : Focusing on Korean Land Spatialization Program (센서기반 응용시스템간 상호운용성 확보에 관한 연구 : 지능형국토정보기술혁신사업을 대상으로)

  • Park, Jae-Min;Jung, Yeun-J.;Park, Kwan-Dong;Kim, Byung-Guk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.5
    • /
    • pp.517-528
    • /
    • 2009
  • Korean Land Spatialization Program (KLSP) is a R&D program of the National GIS Project for developing ubiquitous GIS technologies under control of Ministry of Land, Transport and Maritime Affairs. The first program from 2006 to 2012, initiated with $132 million of national fund and $42 million of private matching fund. Aiming 'Innovation of the GIS technology for the ubiquitous Korean land', KLSP consists of five core research projects and one research coordination project. The coordination project's purpose is to practically utilize and commercialize the results of core research projects. Korean Land Spatialization Group (KLSG) is planning a test-bed for testing, integrating, and exhibit- ing the KLSP's outcomes. Integrations of the outcomes are mandatory for the successful KLSG Test-Bed. The main objective of this paper is to introduce KLSP test-bed and three methodologies for integration of the outcomes in KLSP. As a plan of integrations, especially, this paper proposes SWE SOS (Sensor Observation Service) prototype to achieve interoperability of the geo-sensor networks.

Construction of a Microsatellite DNA Profile Database for Pear Cultivars and Germplasm (배 품종 및 유전자원에 대한 Microsatellite DNA 프로파일 데이터베이스 구축)

  • Hong, Jee-Hwa;Shim, Eun-Jo;Kwon, Yong-Sham
    • Horticultural Science & Technology
    • /
    • v.35 no.1
    • /
    • pp.98-107
    • /
    • 2017
  • A DNA profile database was constructed to investigate the genetic relatedness of 72 germplasm samples of Pyrus and related cultivars using microsatellite markers. Three P. pyrifolia, four P. commus, and one P. betulifolia cultivars with different morphological traits were screened using 387 pairs of microsatellite primers. A core set of 11 primer pairs was selected to obtain 133 polymorphic amplified fragments meeting three criteria: high polymorphism information contents (PIC), high repeatability, and distinct allele patterns. The number of alleles per locus ranged between 4 and 22. Average PIC was 0.743 (range: 0.557 - 0.879). Cluster analysis using the unweighted pair - group method with arithmetical average (UPGMA) separated the 72 pear cultivars and germplasm samples into four major groups: Chinese, European pears, and a cluster of 55 Asian pears that could be reclassify into two subcluster, I - $1^{st}$ and II - $2^{nd}$, according to pedigree information. Almost all of the cultivars were discriminated by 11 microsatellite marker genotypes. The microsatellite DNA profile database may be utilized as tool to verify distinctness, uniformity, and stability between candidate cultivar, and to verify in the distinctness of existing cultivars.

SHEAH BOND STRENGTH OF VENEERING CERAMIC TO ELECTROFORMED GOLD WITH THREE DIFFERENT SURFACE TREATMENT (표면처리방법에 따른 전기성형금속의 도재결합강도)

  • Kim Cheol;Lim Jang-Seop;Jeon Young-Chan;Jeong Chang-Mo;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.599-610
    • /
    • 2005
  • Purpose: The success of the bonding between electroformed gold and ceramic is dependent on the surface treatment of the pure gold coping. The purpose of this study was to evaluate the bonding strength between the electroformed gold and ceramic with varying surface treatment. Materials and methods: A total of 32 disks,8 were using conventional ceramometal alloy, 24 were using electroforming technique as recommended by manufacturer, were prepared. 24 electroformed disks were divided 3 groups according to surface treatment, i.e. 50 microns aluminium oxide sandblasting(GES-Sand), gold bonder treatment(GES-Bond) and $Rocatec^{TM}$ system(GES-Rocatec). For control group of conventional alloy 50 microns aluminium oxide treatment was done(V-Supragold). Energy dispersive x-ray analysis and scanning electron microscope image were observed. Using universal testing machine, shear bond strength and bonding failure mode at metal-porcelain interface were measured. Results and Conclusion: The following conclusions were drawn: 1. In the energy dispersive x-ray analysis, the Au was main component in electroformed gold(99.9wt%). After surface treatment, a little amount of $Al_2O_3(2.4wt%)$ were found in GES-Sand, and $SiO_2(4wt%)$ in GES-Bond. In GES-Rocatec, however, a large amount of $SiO_2(17.4wt%)$ were found. 2. In the scanning electron microscopy, similar pattern of surface irregu larities were observed in V-Supragold and GES-Sand. In GES-Bond, surface irregularities were increased and globular ceramic particles were observed. In GES-Rocatec, a large amount of silica particles attached to metal surface with increased surface irregularities were observed. 3. The mean shear bond strength values(MPa) in order were $22.9{\pm}3.7(V-Supragold),\;22.1{\pm}3.8(GES-Bond),\;20.1{\pm}2.8(GES-Rocatec)\;and\;13.0{\pm}1.4(GES-Sand)$. There was no significant difference between V-Supragold, GES-Bond, and GES-Rocatec. (P>0.05) 4. Most bonding failures modes were adhesive type in GES-Sand. However, in V-Supragold, GES-Bond and GES-Rocatec, cohesive and combination failures were commonly observed. From the result, with proper surface treatment method electroformed gold may have enough strength compare to conventional ceramometal alloy.

Evaluation of Phototoxicity for Cosmetics and Alternative Method (화장품 광독성 평가와 동물대체시험법)

  • Lee, Jong-Kwon;Sin, Ji-Soon;Kim, Jin-Ho;Eom, Jun-Ho;Kim, Hyung-Soo;Park, Kui-Lea
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.3 s.52
    • /
    • pp.245-251
    • /
    • 2005
  • Safety is one of the key issue in the regulation of cosmetics. Cosmetic Act deals with it in Korea. The guidance for the testing cosmetic ingredients and their safety evaluation are prepared by Korea Food and Drug Administration. Ultraviolet radiation could Induce skin damage, edema, erythema, photoaging, immune dysfunction and skin cancer. Ultraviolet radiation is classified as Group 2A(probably carcinogenic to humans) by International Agenry for Reaserch on Cancer(IARC). The in vitro methodologies for evaluating the toxic potential of ingredients reported in the literature have not yet been sufficiently validated for use in areas other than the study for mutagenicity/genotoxicity, for pre-screening for severe irritancy, for screening of phototoxicity and for evaluating the percutaneous absorption. The 3T3 neutral red uptake photoxicity test (3T3 NRU PT) was accepted as OECD toxicity guideline in 2002. The 3T3 NRU PT is an in vitro method based on a comparison of the cytotoxicitv of a chemical when tested in the presence and in the absence of exposure to a non-cytotoxic dose of UVA/visible light.

Experimental Verification on the Effect of the Gap Flow Blocking Devices Attached on the Semi-Spade Rudder using Flow Visualization Technique (유동가시화를 이용한 혼-타의 간극유동 차단장치 효과에 관한 실험적 검증)

  • Shin, Kwangho;Suh, Jung-Chun;Kim, Hyochul;Ryu, Keuksang;Oh, Jungkeun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.5
    • /
    • pp.324-333
    • /
    • 2013
  • Recently, rudder erosion due to cavitation has been frequently reported on a semi-spade rudder of a high-speed large ship. This problem raises economic and safety issues when operating ships. The semi-spade rudders have a gap between the horn/pintle and the movable wing part. Due to this gap, a discontinuous surface, cavitation phenomenon arises and results in unresolved problems such as rudder erosion. In this study, we made a rudder model for 2-D experiments using the NACA0020 and also manufactured gap flow blocking devices to insert to the gap of the model. In order to study the gap flow characteristics at various rudder deflection angles($5^{\circ}$, $10^{\circ}$, $35^{\circ}$) and the effect of the gap flow blocking devices, we carried out the velocity measurements using PIV(Particle Image Velocimetry) techniques and cavitation observation using high speed camera in Seoul National University cavitation tunnel. To observe the gap cavitation on a semi-spade rudder, we slowly lowered the inside pressure of the cavitation tunnel until cavitation occurred near the gap and then captured it using high-speed camera with the frame rate of 4300 fps(frame per second). During this procedure, cavitation numbers and the generated location were recorded, and these experimental data were compared with CFD results calculated by commercial code, Fluent. When we use gap flow blocking device to block the gap, it showed a different flow character compared with previous observation without the device. With the device blocking the gap, the flow velocity increases on the suction side, while it decreases on the pressure side. Therefore, we can conclude that the gap flow blocking device results in a high lift-force effect. And we can also observe that the cavitation inception is delayed.

Anticoccidial Efficacy of Coccimuel-S composed with Diclazuril on Experimental and Field Coccidiosis in Broiler Chickens (Diclazuril을 주성분으로 하는 콕시멸-에스의 육계에 대한 실험실 및 야외적용 실험에서의 항콕시듐 효과)

  • Cha, Chun-Nam;Son, Song-Ee;Kim, Suk;Lee, Yeo-Eun;Yoo, Chang-Yeul;Park, Eun-Kee;Lee, Hu-Jang
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.154-159
    • /
    • 2012
  • The efficacy of water soluble formulation of diclazuril (Coccimuel-S 0.5%) was tested against $Eimeria$ spp. infection broiler chickens. The experiment was performed both experimentally infection and in the field test. Coccimuel-S composed with diclazuril induced a marked inhibitory effect on the different stages of $Eimeria$ life cycle in experimentally infected broiler chickens treated with the drug. The tested dosage levels of Coccimuel-S (0.5 ml/L, equivalent to diclazuril 2.5 ppm) in drinking water showed the significant effect compared with the control group in controlling coccidial infection and reducing the total oocyst numbers, lesion and fecal scores ($p$ < 0.001). In addition, testing of Coccimuel-S (0.25 and 0.5 ml/L) in naturally infected poultry farms (1,200 broiler chickens), showed the significant anticoccidial effect compared to control ($p$ < 0.001). In conclusion, addition of Coccimuel-S at the dose of 0.25 and 0.5 ml/L in the drinking water, induced efficacious effect for the treatment of coccidiosis in naturally coccidia infected broiler chickens.

In vitro comparison of measurement accuracy In pre-enlarged and enlarged canals with four apex locators (근관 성형 전후의 네 가지 전자근관장측정기의 측정 정확성의 비교)

  • Sung, Sang-Yup;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.371-377
    • /
    • 2006
  • The purposes of this study were to assess the accuracy of measurements in pre-enlarged canals with small instruments and to compare the accuracies, in enlarged canal, with small size instruments and instruments that match the actual canal diameter using Root ZX, Bingo1020, SmarPex, and e-Magic Finder. Ten extracted teeth were embedded in an alginate model made for testing apex locators. A size 10 file was placed into the root canal until the tip of the file reached the plane of the major diameter of the foramen under a dental operating microscope at the 25 x magnification. The measurement was done with digital caliper and defined as actual length. Electronic length measurement with a size 10 file in pre-enlarged canal was done by reading the index indicating Apex of each device to gain a definite value After completion of canal enlargement to a size 45 file, each difference between actual length and electric measurement value with a size 10 and 40 files in enlarged canal was recorded as L10 and L40. The one-way ANOVA and Scheffe's multiple range tests were computed for analyze the differences among the four apex locators in the same group. The Student's t-test between L10 and L40 of each locator was done. The accuracies of electronic measurements were significantly different among the 4 devices. The file size made no difference on the accuracy of electronic measurement in enlarged canal with same device. The e-Magic Finder was the most accurate device among the 4 apex locators used in this study.