• Title/Summary/Keyword: Groundwater system

Search Result 1,187, Processing Time 0.024 seconds

A Study on the Characteristics of Heat Source Temperature for Two-Well Geothermal System Using Numerical Simulation (수치 시뮬레이션을 이용한 복수정(Two-Well) 개방형 지열 시스템의 열원수 온도 변화 검토)

  • Cho, JeongHeum;Nam, YuJin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.207-212
    • /
    • 2015
  • The use of groundwater and ground_heat is one of the ways to use natural and renewable energy, and it has been considered as a technology to reduce greenhouse gas emissions and increase energy-saving. There are a few researches on the optimum design for the open-loop geothermal system. In this study, to develop the optimal design method numerical simulation of the open-loop geothermal system with two-wells was performed by a groundwater and heat transfer model. In this paper, a study was performed to analyze the system performance according to well distance and pumping flow rate. In the result, average heat exchange rate and heat source temperature were calculated and it was found that they were dependent on the pumping rate.

Geochemical Characteristics and Assesment of Nitrate Nitrogen in Groundwater in Yanggu-Gun, Gangwon-Do in Korea

  • Choi, Won Gyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.24 no.6
    • /
    • pp.26-32
    • /
    • 2019
  • An analysis of groundwater quality is significant for monitoring and managing water contamination and groundwater system. For the purpose of those, the geochemical characteristics of groundwater were studied over the concern for water quality, water type and origin of nitrate nitrogen. Total colony counts were detected in 11 out of 20 samples, and the average value was 31.73 CFU/ml. Range and average of NO3-N concentrations were 0.9~24.0 mg/L and 8.3 mg/L. All groundwater types were found to be Ca2+-HCO3-. The range and average of NO3-N were 0.2~17.4 mg/L and 8.7 mg/L, and those of δ15N were 1.7~8.9‰, and 5.0‰. Careful consideration is required for evaluating the origin of nitrogen when NO3-N concentration is low. In general, noticeable difference between rockbed and alluvial water was not found. The ranges of nitrate origins by chemical fertilizer, livestock manure and domestic sewage, and natural soil were 29.6~76.4%, 14.2~58.9% and 2.6~7.0%, and the average values of those were 57.4%, 37.4%, and 5.3%, respectively. Origin of nitrate was affected by more chemical fertilizer than the other parameters. Rockbed water was more affected by chemical fertilizer than alluvial water.

Cognition on Quality and Cost of Small Drinking Water Plants in Gyungbuk Region (경북지역 소규모수도시설 이용자의 수질.비용에 대한 인식)

  • Kang, Mee-A;Yang, Myeong-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.675-682
    • /
    • 2010
  • Groundwater is an essential drinking water source in Gyungbuk, South Korea. The primary source of nitrate in groundwater is from nitrogen fertilizers. Efficient management of a small drinking water plant requires a good understanding of its status such as the objective and the cognition of users. The objective of this study is to understand user situation and produce useful user-friendly policy based on user cognition. Most people who participated in this study, should take their groundwater from a good quality source. Even though they would like to have a good facility for getting safe water, they were reluctant to do it due to the cost used. It means that people who drink groundwater have no idea that health safety is affected by groundwater quality. The volume used depended upon personal activities such as agriculture and stockbreeding. We can easily find groundwater with nitrate that exceeds drinking water standards. Therefore, we have to carry out groundwater management with two categories ; 1) drinking water only and 2) others according to objectives in small drinking water systems.

Analysis of Ground Deformation Deformation using Resistivity Monitoring Technique at a Tunnel Excavation Area (전기비저항 모니터링을 이용한 터널 주변 지반상태 변화 파악)

  • Ahn, Hee-Yoon;Jeong, Jae-Hyeung;Cho, In-Ky;Park, Sam-Gyu;Kim, Ki-Seog;Jung, Lae-Chul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.93-100
    • /
    • 2007
  • During tunnel excavation, drawdown of groundwater table or discharge from tunnel faces may not only reduce stability of tunnel and work efficiency but cause environmental problems. We have investigated the applicability of electrical resistivity survey for the establishment of the monitoring system for groundwater behavior and detecting flow channel of groundwater during tunnel excavation. The groundwater level was continuously measured at several points for 1 year. Survey was conduted at every 3 months using preinstalled electrical resistivity cables on site. The results show that observed changes in resistivity ratios in the area can be explained with observed changes in groundwater level. Thus, we believed that electrical resistivity analysed together with groundwater data can be applied for the monitoring of groundwater in tunnel area.

  • PDF

Hydrochemistry and Environmental Isotope Studies of the Deep Groundwater in the Munkyeong Area (문경지역 심부지하수의 수리화학 및 환경동위원소 연구)

  • 고용권;김천수;배대석;이동익
    • Economic and Environmental Geology
    • /
    • v.33 no.6
    • /
    • pp.469-489
    • /
    • 2000
  • The hydrogeochemical and isotopic studies on deep groundwater (below a 550 m depth from the ground surface) in the Munkyeong area, Kyeongbuk province were carried out. Two types of deep groundwater (${CO_2}$-rich groundwater and alkali groundwater) occur together in the Munkywong area. ${CO_2}$-rich groundwater (Ca-${HCO_3}$ type) is characterized by low pH (5.8~6.5) and high TDS (up to 2,682 mg/L.), while alkali groundwater (Na-${HCO_3}$ type) shows a high pH (9.1~10.4) and relatively low TDS (72~116 mg/L). ${CO_2}$-rich water may have evolved by ${CO_2}$ added at depth during groundwater circulation. This process leads to the dissolution of surrounding rocks and Ca, Na, Mg, K and ${HCO_3}$ concentrations are eniched. The low $Pco_2$ ($10^{-6.4}$atm) of alkali groundwaters seems to result from the dissolution of silicate minerals without a supply of ${CO_2}$. The ${\delta}^{18}O$ and ${\delta}^D$values and tritium data indicate that two types of deep groundwater were both derived from pre-thermonuclear meteoric water and have evolved through prolonged water-rock interaction. The carbon isotope data show that dissolved carbon in the ${CO_2}$-rich water was possibly derived from deep-seated ${CO_2}$ gas, although further studies are needed. The ${\delta}^{34}S$ values of dissolved sulfate show that sulfate reduction occurred at great depths. The application of various chemical geothermometers on ${CO_2}$-rich groundwater shows that the calculated deep reservoir temperature is about 130~$l75^{\circ}C$. Based on the geological setting, water chemistry and environmental isotope data, each of the two types of deep groundwater represent distinct hydrologic and hydrogeochemical evolution at depth and their movement is controlled by the local fracture system.

  • PDF

Groundwater Level Trend Analysis for Long-term Prediction Basedon Gaussian Process Regression (가우시안 프로세스 회귀분석을 이용한 지하수위 추세분석 및 장기예측 연구)

  • Kim, Hyo Geon;Park, Eungyu;Jeong, Jina;Han, Weon Shik;Kim, Kue-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.4
    • /
    • pp.30-41
    • /
    • 2016
  • The amount of groundwater related data is drastically increasing domestically from various sources since 2000. To justify the more expansive continuation of the data acquisition and to derive valuable implications from the data, continued employments of sophisticated and state-of-the-arts statistical tools in the analyses and predictions are important issue. In the present study, we employed a well established machine learning technique of Gaussian Process Regression (GPR) model in the trend analyses of groundwater level for the long-term change. The major benefit of GPR model is that the model provide not only the future predictions but also the associated uncertainty. In the study, the long-term predictions of groundwater level from the stations of National Groundwater Monitoring Network located within Han River Basin were exemplified as prediction cases based on the GPR model. In addition, a few types of groundwater change patterns were delineated (i.e., increasing, decreasing, and no trend) on the basis of the statistics acquired from GPR analyses. From the study, it was found that the majority of the monitoring stations has decreasing trend while small portion shows increasing or no trend. To further analyze the causes of the trend, the corresponding precipitation data were jointly analyzed by the same method (i.e., GPR). Based on the analyses, the major cause of decreasing trend of groundwater level is attributed to reduction of precipitation rate whereas a few of the stations show weak relationship between the pattern of groundwater level changes and precipitation.

Long-Term Trend of Groundwater Recharge According to Urbanization (도시화에 의한 장기 지하수 함양량 변화)

  • Lee, Seung-Hyun;Bae, Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.779-785
    • /
    • 2010
  • To solve a problem of water supply on urban areas, groundwater recharge has to be assessed not only for evaluating the possibility of groundwater development but also for identifying a sustainable aquifer system for water resource development. The assessment of groundwater recharge has been challenged since the land use has been changed constantly. In this study, the groundwater recharge and its ratio were assessed from 1961 to 2007 in Su-yeong-gu, Busan, South Korea by analyzing precipitation, land use, and soil characteristics. For land use analysis, the urbanization change was considered. The land use areas for the residential, agricultural, forest, pasture, bare soil, and water in 1975 occupy 18.6 %, 30.0%, 48.8%, 0.1%, 2.0%, and 0.5% of total area, respectively. The land use ratios were sharply changed from 1980 to 1985; the agricultural area was decreased to 18.3%, and the residential area was increased to 15.0%. From 1995 to 2000, the agricultural area was decreased to 5.5%, and the residential area was increased to 5.4%. The annual averages of precipitation, groundwater recharge, and its ratio were 1509.3 mm, 216.0 mm, and 14.3% respectively. The largest amount of the groundwater recharge showed in 1970 as 408.9 mm, comparing to 2138.1 mm of annual rainfall. Also, the greatest ratio of the groundwater recharge was 19.8% in 1984 with 1492.6 mm of annual rainfall. The lowest amount and ratio of the groundwater recharge were 71.9 mm and 8.0% in 1988, relative to 901.5 mm of annual precipitation. As a result, it is concluded that rainfall has increased, whereas groundwater recharge has decreased between 1961 and 2007.

Hydrogeochemistry and Microbial Community Structure of Groundwater in an Agricultural Area (농업지역 지하수의 수리지화학 및 미생물 군집 구조 분석)

  • Kim, Dong-Hun;Oh, Yong Hwa;Lee, Bong-Joo;Lee, Jung-Yun
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.2
    • /
    • pp.61-75
    • /
    • 2022
  • This study evaluated the potential threat of agricultural and human activities to groundwater in the Noseong stream watershed, a typical agricultural area, through hydrogeochemical characteristics and microbial community analyses. The groundwater in the study area was Ca-SO4 and Ca-HCO3 types alluvial aquifer mainly used for agricultural and living purposes, and contained high levels of NO3- and Cl- ions generated from anthropogenic sources such as fertilizer, livestock wastewater, and domestic sewage. Proteobacteria was most abundant in all samples with an average of 46.1% while Actinobacteria, Bacteroidetes, and Cyanobacteria were dominant on an occasional basis. The prevalence of aerobic bacteria such as the genus Mycobacterium, Flavobacterium, and Sphingomonas suggests that groundwater was well connected with the surface layer. The potential pathogen Mycobacterium was detected in most samples, and other pathogenic bacteria were also widely distributed, indicating the vulnerability to contamination. Therefore, an integrated management system is required to secure the sustainable use of groundwater in agricultural areas with high groundwater dependence.