• 제목/요약/키워드: Groundwater storage

검색결과 276건 처리시간 0.037초

지하수류가 대수층 열저장 시스템의 성능에 미치는 영향(3) (The Influence of Groundwater Flow on the Performance of an Aquifer Thermal Energy Storage (ATES) System)

  • 한정상;이주현;김영식;이광진;홍경식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권4호
    • /
    • pp.9-26
    • /
    • 2017
  • When a warm well located downgradient is captured by cold thermal plume originated from an upgradient cold well, the warm thermal plume is pushed further downgradient in the direction of groundwater flow. If groundwater flow direction is parallel to an aquifer thermal energy storage (ATES), the warm well can no longer be utilized as a heat source during the winter season because of the reduced heat capacity of the warm groundwater. It has been found that when the specific discharge is increased by $1{\times}10^{-7}m/s$ in this situation, the performance of ATES is decreased by approximately 2.9% in the warm thermal plume, and approximately 6.5% in the cold thermal plume. An increase of the specific discharge in a permeable hydrogeothermal system with a relatively large hydraulic gradient creates serious thermal interferences between warm and cold thermal plumes. Therefore, an area comprising a permeable aquifer system with large hydraulic gradient should not be used for ATES site. In case of ATES located perpendicular to groundwater flow, when the specific discharge is increased by $1{\times}10^{-7}m/s$ in the warm thermal plume, the performance of ATES is decreased by about 2.5%. This is 13.8% less reduced performance than the parallel case, indicating that an increase of groundwater flow tends to decrease the thermal interference between cold and warm wells. The system performance of ATES that is perpendicular to groundwater flow is much better than that of parallel ATES.

대수층 축열 에너지(ATES) 시스템 모델에서 지하수 유동 영향에 의한 지반내 온도 분포 예측 시뮬레이션 (Simulation of thermal distribution with the effect of groundwater flow in an aquifer thermal energy storage (ATES) system model)

  • 심병완
    • 한국지열·수열에너지학회논문집
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) can be a cost-effective and renewable geothermal energy source, depending on site-specific and thermohydraulic conditions. To design an effective ATES system having the effect of groundwater movement, understanding of thermohydraulic processes is necessary. The heat transfer phenomena for an aquifer heat storage are simulated by using FEFLOW with the scenario of heat pump operation with pumping and waste water reinjection in a two layered confined aquifer model. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at the both wells during 365 days. The average groundwater velocities are determined with two hydraulic gradient sets according to boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions of three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.001 are shaped circular, and the center is moved less than 5 m to the direction of groundwater flow in 365 days simulation period. However at the hydraulic gradient of 0.01, the contour center of the temperature are moved to the end of east boundary at each slice and the largest movement is at bottom slice. By the analysis of thermal interference data between two wells the efficiency of the heat pump system model is validated, and the variation of heads is monitored at injection, pumping and no operation mode.

  • PDF

실내인공강우기를 이용한 경사지 밭의 토양유실량과 오염부하 모의 (Simulation of generable muddy water quantity and pollutant loads in sloping field using artificial rainfall simulator)

  • 신민환;최용훈;서지연;이재운;최중대
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.986-990
    • /
    • 2009
  • Using artificial rainfall simulator, the soil loss, which is deemed as most cause of muddy water problem among Non-point source(NPS) pollutant, was studied by the analysis of direct runoff flow, groundwater runoff, and groundwater storage properties concerned with rainfall intensity, slope of area, and land cover. The direct runoff showed increasing tendency in both straw covered and bared boxes which are 5%, 10%, and 20% sloped respectively. Also the direct runoff volume from straw covered surface boxes were much lower than bared surface boxes. It's deemed as that the infiltration capacity of straw covered surface boxes were increased, because the surface sealing by fine material of soil surface didn't occurred due to the straw covering. Under the same rainfall intensity and slope condition, 2.4 ${\sim}$ 8.2 times of sediment yield were occurred from bared surface boxes more than straw covered surface boxes. The volume of infiltrated were increased due to straw cover, the direct runoff flow were decreased with decreasing of tractive force in surface. To understand of relationship the rate of direct runoff flow, groundwater runoff, and groundwater storage by the rainfall intensity, slope, and land cover, the statistical test was performed. It shows good relationship between most of factors, expect between the rate of groundwater storage and rainfall intensity.

  • PDF

환경콘 관입시스템을 이용한 유류저장소 및 폐기물매립지 지중환경특성 조사 (Geo-Environmental Site Investigation for Underground Oil Storage facilities and Landfill Using the Envi-Cone Penetrometer System)

  • 정하익;홍승서;김영진;홍성완;곽무영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.33-36
    • /
    • 2000
  • The purpose of this study investigated underground oil storage(USTs) and Landfill using the envi-cone penetrometer system. The electrical resistivity sensor, pH sensor, ORP sensor, and thermometer are installed in envi-cone penetrometer system. This envi-cone penetrometer system provides a continuous profile of measurements, and it is rapid, repeatable, reliable and cost effective for investigation of contaminated ground.

  • PDF

지표수지하수 통합모형을 이용한 무심천 유역의 지하수 개발가능량 산정 (Estimating Exploitable Groundwater Amount in Musimcheon Watershed by Using an Integrated Surface Water-Groundwater Model)

  • 정일문;이정우;김남원
    • 자원환경지질
    • /
    • 제44권5호
    • /
    • pp.433-442
    • /
    • 2011
  • 우리나라의 지하수관리는 연간 지하수 함양량을 기반으로 수행되어 왔으나 지히수 함양량과 지표수-지하수 상호작용은 시공간적으로 변동하는 양이므로 지속적인 모니터링과 동적인 분석을 통해 지하수자원의 지속가능성이 평가되어야 할 것이다. 본 연구에서는 무심천 유역을 대상으로 지표수-지하수 통합해석 모형인 SWAT-MODFLOW를 이용하여 다양한 지하수 양수 시나리오(무양수 및 현 이용량의 1~3배)에 대한 수문성분 해석을 수행하였다. 현 이용량으로 양수하는 경우가 비교적 지속가능한 개발량으로 판단되었는데 이때 연간 기저유출량은 16%, 대수층 저류량은 27 mm 감소하는 것으로 나타났다. 지하수의 지속가능성을 평가하기 위해서는 지하수 이용에 따른 수문학적, 생태학적, 사회 경제적, 기술적 영향을 평가하는 총체적 접근법이 도입되어야 하며 이를 위해서는 물리적인 분석과 함께 지역사회의 합의 또한 중요한 의사결정 방식이라고 판단되었다.

대수층 축열 에너지(ATES) 활용 시스템 모델의 설계인자 추정을 위한 시뮬레이션 (Simulation for the Estimation of Design Parameters in an Aquifer Thermal Energy Storage (ATES) Utilization System Model)

  • 심병완
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제10권4호
    • /
    • pp.54-61
    • /
    • 2005
  • 대수층 축열 에너지(ATES) 시스템은 지반의 특성과 이용량에 따라 매우 경제적인 새로운 대체에너지로 이용될 수 있다. 적절한 ATES 시스템 설계를 통하여 주어진 수리지질 특성에 적합한 ATES 시스템을 개발하기 위해서는 대수 층내 수리열역학적 과정의 이해가 필수적이다. 본 논문에서는 지하수 양수 및 열펌프에 이용된 불을 재주입하는 방식의 지하수 열펌프 운영에 대한 두 가지 시나리오를 통하여 두 개의 층으로 이루어진 대수층 모델에 적용하여 대수층내 열 저장에 대한 수리열역학적 현상을 시뮬레이션하였다. 첫 번째 시나리오에서는 양수 우물과 주입 우물을 계절에 따라 서로 교대로 시스템을 운영한 경우에 열 거동에 의한 온도 분포와 지하수위를 시뮬레이션 하였으며, 두 번째는 주입과 양수 우물 위치를 고정하여 시뮬레이션 하였다. 356일 이후 주입 우물 주변의 온도 분포는 주입수의 온도와 주입정으로 부터의 거리에 지배적인 영향을 받는 것으로 나타났다. 지표온도 분포는 30과 50 m 심도의 온도 분포에 비하면 미미한 변화만 나타났으며, 각 층에서의 열 거동은 공극률과 지하수의 유동 특성에 따라 매우 민감한 것으로 나타났다. 그리고 양수와 주입우물에서의 지하수위와 온도변화를 모니터링하여 열펌프 운영 방식에 따른 효율성을 실험하고, 두 우물간의 열 간섭현상을 분석하였다.

원유 저장용 지하공동의 건설중 점토 그라우팅에 의한 지하수 제어 (Countrol of Groundwater by Clay Grouting in Undergroun Excavation of Oil Storage Caverns)

  • 김치환;박창우;이석천
    • 터널과지하공간
    • /
    • 제3권1호
    • /
    • pp.24-32
    • /
    • 1993
  • Groundwater movement is one of the most important elements in the construction and management of underground oil storage cavern. To control the groundwater flow, grouting is run in parallel with water curtains. But as traditional grouting is conducted within cavern before and after excavation, the effect of grouting is delayed and the injection sphere is limited in the rock mass. Therefore, it is desirable to introduce a more extensive and effective grouting. This article is to present the caly grouting, which was the first to be carried out in the construction of underground caverns for oil storage in Japan. After conducting the clay grouting, the effect was confirmed by ground water level and infiltration quantity to the caverns.

  • PDF

지하 석유비축기지 주변의 지하수 개발에 의한 수리지질학적 영향의 수치해석 연구 (A Study of Numerical Analysis on Hydrogeological Influence by Groundwater Development around Underground Oil Storage Cavern)

  • 정현영;송무영;이경주
    • 지질공학
    • /
    • 제11권1호
    • /
    • pp.37-50
    • /
    • 2001
  • 서울 근교의 화강편마암지역 지하 석유비축기지 주변 지하수계 모델링 연구를 통하여, 기지 인근에서 지하수를 개발할 때의 영향 및 지하수 개발의 악영향 저감을 위한 수벽공 설치의 효과 등을 파악하고, 실제 설치 후의 영향을 측정하여 모델링 결과와 비교 분석하므로서 기지의 관리 및 운영에 참고하고자 하였다. 심부 지하수를 개발한 경우의 기지 주변의 지하수 유동체계 분석, 그리고 이 개발 위치와 기지 사이에 수벽공을 설치했을 경우의 유동체계를 MODFLOW 수치해석방법으로 분석하였다. 기지 주변 관측공의 실제 지하수위는 EL.+30∼60m 범위에서 변동하며, 모델링 결과는 EL.+20∼50m 범위에서 변동하여 유사한 양상을 보이고 있다. 지하수 개발에 의해 기지 주변의 수위가 하강하였다가 수벽설치 후에 회복되었음을 수치해석을 통해 확인할 수 있었다. 지하지질구조 및 수리지질 요소를 적절히 입력하고 효과적인 모델링 연구를 수행하여 기지의 운영에 기여하였음을 확인하였다.

  • PDF

단열암반 대수층에서 조석분석법을 이용한 수리상수 추정 (Hydrogeologic Parameter Estimation by Using Tidal Method in a Fractured Rock Aquifer)

  • 심병완;정상용
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제9권3호
    • /
    • pp.27-32
    • /
    • 2004
  • 해안가에 발달된 단열암반 대수층에서 수리지질 인자를 추정하기 위하여 조석에 의한 지하수위 변동 현상을 이용하는 조석분석법을 적용하였다. 두 관측정의 지하수위 시계열 자료는 조석에 의한 대수층내 유효응력 전달에 의해 조수위 변동과 비슷한 사인곡선 형태로 나타났다. 교차상관함수를 이용하여 조석과 두 관측정의 지하수위 변동 사이의 개략적인 시간지연을 계산하였으며, 그 결과 심도가 깊은 공의 시간지연이 크게 나타났다. 그리고 조석효율과 시간지연을 계산하여 이들로부터 각각의 저류계수를 추정한 결과 큰 차이를 나타내었다. 본 연구지역에서 실시된 순간충격 시험에 의하여 측정된 저류계수는 조석분석법에서 시간지연을 이용하여 계산한 값과 유사하게 나타나며, 심도가 깊은 공에서 보다 비슷한 값을 나타내고 있다. 조석효율은 피압층에 발달된 균열로 인한 자유면대수층의 영향과 수직적인 지하수 유동에 의해 대수층의 수리상수를 추정하는데 한계가 있는 것으로 사료된다. 따라서 조석분석법은 해안대수층의 수리지질인자를 추정하는데 지하수공의 위치나 대수층의 수리지질적 특성을 고려하여 해석한다면 경제적이고 유용한 방법으로 판단된다.