A Study on Smart Soil Resistance Measuring Device for Safety Characterized Ground Design in Converged Information Technology (ICT 융합 환경에서의 안전 특성화 접지 설계를 위한 스마트 대지 저항 측정 기술에 관한 연구)

  • Kim, Hong-Yong;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.203-209
    • /
    • 2019
  • In this work, a new land-specific resistance measuring device (GM) and a measuring probe (Grounding Rod) are connected to the WENNER quadrant as power-line communication (PLC). In groups of two (P1,P2) probes, five to ten probes are installed in series on the ground at intervals of 1m, 2m, 4m, 8m, and 16m, respectively. If the PLC signal from the GMD is detected by the receiver of the Probe 1 (P1) for measurement, the minute voltage and current for measurement flow from the PSD (power supply) attached to the probe to the ground, and then, through the soil between P1 and P2, enters the Probe 1 (P2). The resistance value is then measured by the principle of voltage drop due to ground resistance. Measure the earth resistance every T seconds up to 1 trillion and store the measured data on the Arduino Server mounted on the main equipment. Stored measurement data can be derived from formulas by Ohm's Law and from inherent resistance (here,). Data obtained in real time will be linked to CDGES programs installed on Main PC, enabling data analysis and real-time monitoring of the ground environment on land. In addition, a three-dimensional display is possible with 3D graph support by identifying seasonal characteristics such as temperature and humidity of land (soils). The limitations of the study will require specific application measures of Test Bed for commercial access to a model that has been developed and operated experimentally.

Consideration of Conductance between Rails and Ground in DC Railway (직류전기철도 레일-대지간 절연저항 측정 방안)

  • Han, Moon-Seob;Kim, Ju-Rak;Jung, Ho-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.166-168
    • /
    • 2008
  • DC feeding system is mainly floating but the rail potential and the leakage current are created because of long parallelism between rails and ground. Rail potential causes electric shock to human and leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important recent DC feeding system. Rail potential and leakage current are analysed based on propagation theory that is utilized in order to simulate grounding system. New measurement procedure is proposed based on this analysis in order to more be accurate in result.

  • PDF

Development of a Non-contacting Capacitive Sensor Based on Thompson-Lampard Theorem for Measurement of ${\mu}m-order$ Displacements (Thompson-Lampard 정리를 적용한 마이크로미터 변위 측정을 위한 비접촉식 전기용량 센서 개발)

  • Kim, Han-Jun;Kang, Jeon-Hong;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.9
    • /
    • pp.443-448
    • /
    • 2006
  • Non-contacting capacitive sensor based on Thompson-Lampard theorem have been fabricated and characterized for measuring of 때 order displacements. To overcome disadvantages of the existed capacitive sensors of parallel plate type with 2-electrodes and 3-electrodes, the developed new sensor was designed to have 4-electrodes with a constant gap of 0.2mm between the electrodes. Two of the electrodes were used as a high potential electrode and a low one, the other two electrodes were used as guard electrodes. These electrodes were made from copper using RF sputtering system on a sapphire plate with diameter 17 mm and thickness 0.7 mm. This sensor can be used for measuring the distance not only between the sensor and metallic target connected to ground potential but also non-metallic target without ground connection.

Analysis of correlation between shield TBM construction field data and settlement measurement data (쉴드 TBM 시공데이터와 지반침하 계측데이터 간 상관성 분석)

  • Jung, Ye-Rim;Nam, Kyoung-Min;Kim, Han-Eol;Ha, Sang-Gui;Yun, Ji-Seok;Cho, Jae-Eun;Yoo, Han-Kyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.79-94
    • /
    • 2022
  • The demand for tunnel construction is increasing as part of underground space development due to urban saturation. The shield TBM method minimizes vibration and noise and minimizes ground deformation that occurs simultaneously with excavation, and shield TBM is generally applied to tunnel construction in urban areas. The importance of urban ground settlement prediction is increasing day by day, and in the case of shield TBM construction, ground deformation is minimized, but ground settlement due to tunnel excavation inevitably occurs. Therefore, in this study, the correlation between shield TBM, which is highly applicable to urban areas, and ground settlement is analyzed to suggest the shield TBM construction factors that have a major effect on ground settlement. Correlation analysis was performed between the shield TBM construction data and ground settlement measurement data collected at the actual site, and the degree of correlation was expressed as a correlation coefficient "r". As a result, the main construction factors of shield TBM affecting ground settlement were thrust force, torque, chamber pressure, backfill pressure and muck discharge. Based on the results of this study, it is expected to contribute to the presentation of judgment criteria for major construction data so that the ground settlement can be predicted and controlled in advance when operating the shield TBM in the future.

Estimation of subsea tunnel stability considering ground and lining stiffness degradation measurements (지반 및 라이닝 열화 계측 정보를 반영한 해저 터널의 안정성 평가)

  • An, Joon-Sang;Kim, Byung-Chan;Moon, Hyun-Koo;Song, Ki-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.389-399
    • /
    • 2016
  • Efficiency for estimation of subsea tunnel safety can be increased through reflecting back analysis algorithm to displacement measurements besides other measurement information such as stress, water pressure and ground stiffness degradation. In this study, the finite difference code FLAC3D built-in FISH language is used. In addition, the stability of the tunnel lining will be evaluated from the development of displacement-based algorithm and its expanded algorithm with conformity of several parameters such as stress measurements, water pressure measurements, tunnel lining degradation measurements and ground stiffness degradation measurements. By using additional measurement information to assess the stability of subsea tunnel, it was confirmed that the error rate is reduced to the tunnel back analysis.

Research on the Variable Rate Spraying System Based on Canopy Volume Measurement

  • Hu, Kaiqun;Feng, Xin
    • Journal of Information Processing Systems
    • /
    • v.15 no.5
    • /
    • pp.1131-1140
    • /
    • 2019
  • Characteristics of fruit tree canopies are important target information for adjusting the pesticide application rate in variable rate spraying in orchards. Therefore, the target detection of the canopy characteristics is very important. In this study, a canopy volume measurement method for peach trees was presented and a variable rate spraying system based on canopy volume measurement was developed using the ultrasonic sensing, one of the most effective target detection method. Ten ultrasonic sensors and two flow control units were mounted on the orchard air-assisted sprayer. The ultrasonic sensors were used to detect the canopy diameters and the flow controls were used to modify the flow rate of the nozzles in real time. Two treatments were established: a constant application rate of $300Lha^{-1}$ was set as the control treatment for the comparison with the variable rate application at a $0.095Lm^{-3}$ canopy. The tracer deposition at different parts of peach trees and the tracer losses to the ground (between rows and within rows) were analyzed in detail under constant rate and variable rate application. The results showed that there were no significant differences between two treatments in the liquid distribution and the capability to reach the inner parts of the crop canopies.

Effects of Standing Aids on Lumbar Spine Posture and Muscle Activity in the Lumbar Spine and Hip during Prolonged Standing

  • Kim, Hyeon-Jin;Choi, Young-Eun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.2
    • /
    • pp.21-28
    • /
    • 2019
  • PURPOSE: This study was conducted to compare different standing postures with the use of standing aids for lumbar spine posture and muscle activity, and to identify the most desirable standing posture. METHODS: The lumbopelvic angle was assessed based on static radiographic measurement on the sagittal plane. Lumbar lordosis, lumbosacral lordosis, and the intervertebral joint angle at L1/L5 and L5/S1 were measured using radiography in three standing postures (standing on level ground, standing with one foot on a platform, and standing on a sloped surface). In addition, muscle activity was measured using surface electromyography to examine the co-contraction of the lumbar and hip muscles. RESULTS: Lumbar lordosis, lumbosacral lordosis, and L5/S1 intervertebral joint flexion occurred with one foot on the platform. No significant differences were found between standing on a sloped surface and standing on level ground. However, muscle co-contraction was reduced with the use of standing aids. CONCLUSION: This study demonstrated that standing with a foot on a platform induced lumbar lordosis, but that there was no significant difference between standing on a sloped surface and standing on level ground. However, muscle co-contraction was reduced with the use of standing aids. Based on the motor control pattern as a predictor of LBP, the use of standing aids would help workers during prolonged standing.

Models for Measurement of Efficiency of Free Flight Separation Assurance (자유비행 분리보증 효율성 측정모델 연구)

  • Lee, Dae-Yong;Young, Kang-Ja
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.6
    • /
    • pp.977-985
    • /
    • 2011
  • Airborne separation assurance is a key requirement for Free Flight Airspace operations, This paper study the feasibility of airborne separation assurance for free flight Airspaces operations by evaluating the efficiency measurement models. Three qualitatively different methods are utilized; one based Ground and Air conflict probability model, other based Dynamic Density model. the other based Direct operating cost model. The evaluation is Direct Operating Cost model and Two metrics are utilized for the efficiency measurements; airborne separation assurance performed quite well in the Free Flight evaluation; (1) 2 scenario of the conflict situations are resolved; (2) The MD-80 flight peformed separation assurance and efficiency, Not only appling for geometric method algorithm is more efficiently than potential method, but also the most efficiently geometric combined method.

Soil Resistivity Measurement System using Multi-auxiliary Electrodes (다전극 대지저항률 측정시스템)

  • Kim, Hwang-Kuk;Choi, Jae-Sung;Jang, Un-Yong;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.892-899
    • /
    • 2009
  • This paper describes the design and fabrication of a soil resistivity measurement system using 9 auxiliary electrodes; 6 potential-, a reference-, a current-, and a ground- electrode. The measurement system is composed of a current source (300 [Vrms], 5 [A], Sine-wave, 45 $\sim$ 500 [Hz]), a data acquisition (400 [kS/s], 16 bit, 16 Ch.), and an operating program based on a graphical software of National Instrument Co. The proposed system is convenient for choosing the position of electrodes because the soil resistivity is calculated having no concern with the length and the spacing between electrodes.

  • PDF

Isolation Enhancement by the Non-connected Ground Structure for the Mobile Phone MIMO Antenna (비접촉 접지구조에 의한 휴대폰 MIMO 안테나 격리도 향상)

  • Jo, Young-Sang;Son, Tae-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1032-1037
    • /
    • 2016
  • In this paper, the method of isolation enhancement for the mobile phone MIMO antenna of LTE class 40(2300~2400MHz) was studied. Design of MIMO antenna was based on the hybrid antenna that operates both a monopole and an IFA(Inverted F Antenna). A structure for the isolation enhancement which controls induced electric field on the ground plane is located between MIMO antenna, and was not connected with the ground but apart 0.3mm. A MIMO antenna that operates on class 3~40(1710~2400MHz) of LTE service bands and a structure for the isolation enhancement at the class 10 band were designed. VSWR measurement of implemented antenna on the FR4 board showed within 3:1 at entire design bands, and isolation between antennas at the class 40 band was less than -30dB. Isolation was enhanced more than 20dB by the studied structure. ECC(Envelope Correlation Coefficient) for MIMO performance was under 0.1, and antenna average gain and efficiency measured in the anechoic chamber were -4.28~-1.40dBi and 37.32~72.36% respectively.