• 제목/요약/키워드: Ground system

검색결과 6,393건 처리시간 0.035초

비접지 계통에서 영상전류 위상을 이용한 개선된 보호협조 방안 (The Advanced Protection Coordination Scheme using Phase Angle of Zero-Sequence Current in Ungrounded System)

  • 최영준;임희택;최면송;이승재
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.19-25
    • /
    • 2010
  • Most faults are single-phase-to-ground fault in ungrounded system. The fault currents of single-phase-to-ground are much smaller than detection thresholds of measurement devices, so detecting single-phase-to-ground faults is difficult and important in ungrounded system. The protection coordination method using SGR(Selective Ground Relay) and OVGR(Overvoltage Ground Relay) is generally used in ungrounded system. But this method only detects fault line and it has the possibility of malfunction. This paper proposed to advanced protection coordination method in ungrounded system. The method just using zero-sequence current can detect fault line, fault phase, fault section at terminal device. The general protection method is used to back up protection. In the case study, the proposed method has been testified in demo system by Matlab/Simulink simulations.

Feasibility Study of High-Efficiency Ground Heat Exchanger using Double U-tube through a Real-Scale Experiment

  • Bae, Sangmu;Kim, Jaemin;Nam, Yujin
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.33-39
    • /
    • 2017
  • Purpose: The use of renewable energy system is essential for building energy independence and saving energy consumption in the building sector. Among renewable energy technologies, ground source heat pump(GSHP) system is more energy-efficient and environmental-friendly than other heat source systems due to utilize stable ground heat source. However, the GSHP system requires a high initial installation cost and installation space in limited urban area, so it is difficult to have superiority in the market of heat source system. Therefore, it is necessary to develop the installation method of low-cost and improve system performance. This paper aims to evaluate the performance of double u-tube ground heat exchanger(GHX) and verify system feasibility through real-scale experiment. Method: In this study, the real-scale experiment of vertical closed-type GSHP system was conducted using double u-tube GHX and high-efficiency grout. Through the verification experiment, heat source temperature, heat exchange rate(HER) and seasonal performance factor(SPF) were measured according to the long-term operation. In addition, the feasibility analysis was conducted comparing to the single u-tube system. Result: In the results of experiment, average HER was 136.27 W/m and average SPF was 5.41. Furthermore, compared to the single u-tube, the installation cost of the developed system could be reduced about 70% in the same heating load condition.

수평형 지열 히트펌프 시스템의 냉난방 성능 분석 (Performance Analysis of Ground-Coupled Heat Pump System with Slinky-Type Horizontal Ground Heat Exchanger)

  • 손병후
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.230-239
    • /
    • 2012
  • Ground-coupled heat pump (GCHP) systems utilize the immense renewable storage capacity of the ground as a heat source or sink to provide space heating, cooling, and domestic hot water. The main objective of the present study is to investigate the cooling and heating performance of a small scale GCHP system with horizontal ground heat exchanger (HGHE). In order to evaluate the performance, a water-to-air ground-source heat pump unit connected to a test room with a net floor area of 18.4 m2 and a volume of 64.4 m3 in the Korea Institute of Construction Technology ($37^{\circ}39'N$, $126^{\circ}48'E$) was designed and constructed. This GCHP system mainly consisted of slinky-type HGHE with a total length of 400 m, indoor heat pump, and measuring devices. The peak cooling and heating loads of the test room were 5.07 kW and 4.12 kW, respectively. The experimental results were obtained from March 15, 2011 to August 31, 2011 and the performance coefficients of the system were determined from the measured data. The overall seasonal performance factor (SPF) for cooling was 3.31 while the system delivered heating at a daily average performance coefficients of 2.82.

지열원 열펌프의 냉.난방 성능 평가 (Cooling and Heating Performance Evaluation of a Ground Source Heat Pump)

  • 손병후;조정식;신현준;안형준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2117-2122
    • /
    • 2004
  • The main objective of the present study is to investigate the performance characteristics of a ground source heat pump (GSHP) system with a 130 m vertical 60.5 mm nominal diameter U-bend ground heat exchanger. In order to evaluate the performance analysis, the GSHP system connected to a test room with 90 $m^2$ floor area in the Korea Institute of Construction Technology ($37^{\circ}39'$ N, $126^{\circ}48'$ E) was designed and constructed. This GSHP system mainly consisted of ground heat exchanger, indoor heat pump and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July to January in cooling and heating season of $2003{\sim}2004$. The cooling and heating performance coefficients of the system were determined from the experimental results. The average cooling and heating COPs for the system were obtained to be 4.82 and 3.02, respectively. The temperature variations in ground and the ground heat exchanger surface at different depths were also measured.

  • PDF

지상도체 변화에 따른 초전도 반발식 자기부상 특성 해석 (Analysis on the Characteristics of the Superconducting Electrodynamic Suspension According to the Variation of the Ground Conductor)

  • 배덕권;조한욱;이종민;한형석;이창영;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1159_1160
    • /
    • 2009
  • 본 논문에서는 초고속 자기부상열차의 유력한 후보가 될 수 있는 초전도 반발식 자기부상의 특성을 연구하기 위한 반발력을 3차원 유한요소 자기 해석을 통하여 계산하고 분석하였다. 본 해석의 결과에 따르면 움직이는 부분이 없는 정지형 시험기는 반발식 자기부상시험기로써 적용될 수 있다.

  • PDF

전류 및 전위 보조전극을 수직으로 배치하는 전위강하법을 이용한 접지저항의 측정 (Measurement of the Ground Resistance using the Fall-of-Potential Method with the Vertically-placed Current and Potential Auxiliary Electrodes)

  • 이복희;김기복;김유하
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.53-60
    • /
    • 2012
  • The fall-of-potential method is commonly used in measuring the ground resistance of large-scaled grounding system and the current and potential auxiliary electrodes are horizontally arranged. Because the distances between the ground grid to be tested and auxiliary electrodes are limited in downtown areas, it is very difficult to measure accurately the ground resistance of large-scaled grounding system. In this paper, the fall-of-potential method of measuring the ground resistance with the vertically-placed current and potential auxiliary electrodes was examined and discussed. The validity and good accuracy of the proposed method of measuring the ground resistance were confirmed through various simulations and actual tests carried out in uniform and two-layer soil structures.

우리나라 지상시스템의 발전 전망 및 방향 (Prospect and Direction on Korean Ground System Development)

  • 정대원
    • 한국항공우주학회지
    • /
    • 제44권8호
    • /
    • pp.718-727
    • /
    • 2016
  • 우리나라 지상시스템은 위성 관제와 탑재체자료 처리를 위해서 1990년대부터 개발되기 시작하였다. 과학위성, 저궤도위성 및 정지궤도 지상시스템의 초기 개발 시에는 국제기술협력 등이 필요하였으나, 초기 기술 확보 이후에는 국내 독자 기술로 개발되기 시작하였다. 우리나라는 지금까지 총 14기의 지상시스템을 개발하였으며, 본 논문은 이러한 경험을 바탕으로 발전 전망 및 방향을 제시한다. 관제시스템은 재구성, 재사용, 자동화 기술을 기반으로 하는 다중위성 관제시스템 개발이 필요하다. 처리시스템은 다양한 탑재체자료 처리 기술의 확보와 처리정확도 향상을 위한 검보정 기술의 접목이 필요하다. 또한, 탑재체 자료 양의 증가로 인한 고속처리 기술 확보와 처리된 탑재체자료를 사용자 간에 사용하고 통합하는 상호운영성 연구가 필요하다. 끝으로, 다양한 종류의 많은 위성을 운영할 수 있도록 국내외에 분포된 안테나 등 국가 지상시스템 인프라 망 구축이 필요하다.

무기체계 구성장치의 연결성 제어 및 자율 재구성을 위한 플러그앤플레이 프레임워크 (Plug-and-Play Framework for Connectivity Control and Self-Reconfiguration of Weapon System Components)

  • 장혜민;강석종;조영걸;윤주홍;윤지혁
    • 한국군사과학기술학회지
    • /
    • 제24권3호
    • /
    • pp.328-338
    • /
    • 2021
  • A study on common modular design based on open standards to reduce the life cycle cost of ground weapon system is underway. Since the ground weapon system includes major mission equipment such as fire control system, it is essential to apply the concept of fault tolerance through automatic reconfiguration and blocking unspecified equipment through connectivity control. However, it is difficult to generalize due to the difference in operating characteristics for each system. In this paper, we propose a plug-and-play framework, which includes plug-and-play architecture and mechanism. The proposed method can be used in common by the application of each component as it is divided into a common service layer. In addition, the proposed connectivity control and autonomous reconfiguration method facilitates reflection of operating characteristics for each system. We constructed a verification environment that can simulate ground weapon systems and components, and verified that the proposed framework works through scenario-based functional tests.

지하수 열원 복수정 지열 열펌프 시스템의 성능에 관한 실험적 연구 (An Experimental Study of Ground Water Source Two Well Type Geothermal Heat Pump System)

  • 임효재;권정태;김창업;공형진;박성구
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.468-474
    • /
    • 2009
  • Ground water source heat pump system is the oldest one of the ground source heat pump systems. Despite of this, little formal design information has been available until recently. The important design parameters for open system are the identification of optimum ground water flow, heat exchanger selection and well pump. In this study, the capacity of 50 RT system of two well type ground water heat pump system was used. As a result, static water level was -7 m and the level during the heating operation was -32 m, cooling operation was -40 m. The initial static water level recovered within 48 hrs. The temperature of ground water is $15.6^{\circ}C$ for heating season and $16.2^{\circ}C$ for cooling season and does not depend on the outdoor temperature. Operation efficiency of the system shows that, COP 3.1 for heating and COP 4.2 for cooling.

지뢰 탐지를 위한 지면추종 및 탐지위치 표식에 관한 연구 (A Study on the Ground Following and Location Marking Method for Mine Detection System)

  • 이명천;신호철;윤종훈
    • 한국군사과학기술학회지
    • /
    • 제14권6호
    • /
    • pp.1002-1008
    • /
    • 2011
  • The mine-detection system, which is one of the various mission equipments for Ground Vehicle System, detects mine under the ground. The mine detection sensors comprised of Metal Detection(MD) sensor and Ground Penetration Radar(GPR) are attached on the end of the multi-DOF manipulator. The manipulator moves the sensor to sweep mine areas keeping the pre-determined distance between the sensor and ground to enhance mine detection performance. The detection system can be operated automatically, semi-automatically and manually. When the detection system is operated automatically, the sensor should avoid collisions with unexpected obstacles which may exist on the ground. Two types of ultra-sonic sensors were developed for the mine detection sensor system to keep the appropriate gap between sensor and the ground to avoid the obstacles. Also, mine place marking device was developed.