• Title/Summary/Keyword: Ground stress

Search Result 1,100, Processing Time 0.032 seconds

Advanced C.I.P Method to Use the Steel-Casing with Inner Joint (조인트 부착 강관 케이싱을 이용한 개량형 C.I.P 공법)

  • Jang, Seoyong;Choi, Jaesoon;Song, Byungwoong;Choi, Yoonyoung;Yoon, Joongsan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.2
    • /
    • pp.95-102
    • /
    • 2012
  • In this study, practical verifications for an advanced C.I.P(Cast in Place Pile) construction method were carried out. The structural characteristics of the method is to attach an angular joint in the steel-casing. This joint plays an important role in boring vertically, connected pile to pile, and protects the permeation of the ground water. For verifications, experimental research and numerical analysis were performed. In the experimental research, two model-tests were set up with the real scale steel-casing. One is to examine the leakage in the joint of piles and the other is to compare earth pressures in the front and the joint, respectively. In addition, 3 point bending test and compressive loading test were carried out and numerical analysis was performed to simulate the loading test. As a result of model-tests, the leakage in the pile joints was not shown up to 300 KPa of water pressure and stress concentration in the joint is out of the question. From the results of bending and compressive test, it was found that the new advanced C.I.P method is more convenient and superior than the conventional method.

A study on a terms of "The Jung pung(中風) therories of JuJinHyoung(朱震亨)" (주진형(朱震亨)의 중풍론(中風論)에 관한 고찰(考察))

  • Ko, Kyeong-Deok;Lee, Dong-Won;Jung, Seung-Hyun;Shin, Gil-Cho;Lee, Won-Chul
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.6 no.1
    • /
    • pp.129-136
    • /
    • 1997
  • We inquired into tile origins, pathologies, theraphies and prescriptions of Jungpung(中風) especially on the ground of Keokchiyeron(格致餘論) Dangeosimbub(丹溪心法) written by JuJinHyoung(朱震亨) as medical books, from this study we could get that conclusions. 1. According to special feature of the theroies of JuJinHyoung's(朱震亨) Jungpung(中風) he thought pathologies of Jungpung(中風) as "sub seong dam dam seong yeol yeol seong pung 濕生痰痰生熱 熱生風" through studying stress on regional characteristics and thought much of dam(痰) as one of major elements of internal causes. 2. He suggested chi-dam(治痰) in the first place in the treatment of Jungpung(中風) and emphasises the treatment using Succus Pyllostachyos(竹瀝), waterly extracted Rhizoma Zingiberis(薑汁) in that they had the virtues of sodam-ganghwa(消痰降火), geo-gyeongrak(開經絡), haeng-heolgi(行血氣) 3. He treated differently whether a man in fat and thin, and have right or left hemiplegia, but he prescribed herb-medications on the principle that that medications should have the virtues of chi-dam(治淡).

  • PDF

Structural Stability, Weathering and Conservation Method of Granite Standing Sculptured Buddha at Hwangsang-dong, Kumi (구미 황상동 마애여래입상의 구조적 안정성, 풍화 및 보존방안)

  • Lee, Chan Hee;Choi, Suck Won;Suh, Mancheol;Chae, Sang Jeong
    • Journal of Conservation Science
    • /
    • v.9 no.1
    • /
    • pp.21-32
    • /
    • 2000
  • Rock composition of the Hwangsang-dong Granite Standing Sculptured Buddha (Treasure No. 1122) in the Kumi City is biotite-hornblende granodiorite which consists of about 30 pieces of individual rock blocks of same compositions. However, the cap rocks is pebble-bearing coarse sandstone. Rock blocks of the Standing Buddha and surrounding out crops occur well developed several joint systems of $N25^{\circ}$ to $45^{\circ}W$ strike and nearly vertical (70 to $85^{\circ}SE$) dipping. Rock blocks of the Standing Buddha showed vertical, horizontal and oblique joints, and those blocks are well supported by individual blocks. However, the junction part of the blocks are under dangerous situation due 10 seriously mechanical and chemical weathering. Host rock of the Standing Buddha belongs to the HW grade, therefore mostly rock-forming minerals of the granodiorite Standing Buddha altered with clay and iron hydroxide minerals by mineralogical and chemical weathering. Near surface of the Standing Buddha show spore and mycelium of green algaes, and a joint plane alive with weeds. We suggest that if structural stability for the Standing Buddha remove essentially a unstable rock blocks from the main body, and the main body necessitate supporting by rock bolting method because of repeated unstability and minimizing stress to the rock blocks. For the opened joint planes, fractured surface and alive weeds will attempt to fill in a petro-epoxy, petro-filler and biochemical treatments for the algaes, and ground water curtain and wall seems to be necessary for water flow and diminishing humidity of the Standing Buddha.

  • PDF

Design for Installation of Suction Piles in Sand Deposits for Mooring of Floating Offshore Structures (부유식 해상구조물의 계류를 위한 사질토 지반의 석션파일 설계)

  • Park, Chul-Soo;Lee, Ju-Hyung;Baek, Du-Hyun;Do, Jin-Ung
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.10
    • /
    • pp.33-44
    • /
    • 2014
  • The preliminary design of suction pile as the supporting system for concrete floating structures was performed for the pilot project of the southwest coast area in Korea. Prior to starting design work, site conditions of the area including ground and hydraulic conditions, and a 100-year return period external force were throughly evaluated. The suction pile for mooring of the offshore floating structures has to satisfy the lateral resistance against external force as well as the penetration ability according to the soil conditions such as soil types, shear strengths, effective stresses, and seepage forces. In the design, the required penetration depths, which were stable for lateral resistance, were evaluated with the diameters of cylindrical suction pile as the final installing ones. And the design suction pressures at each penetrating depths, at which sand boiling did not occur, were assessed through the comparison of penetration and penetrationresistance forces. As a result, it was impossible for suction piles with the diameter range of 3.0~5.0 m to penetrate into required penetration depths. On the other hand, suction piles with the diameter range of 6.0 m and 7.0 m satisfied both the horizontal stability and the penetration ability by design suction pressures at the required penetration depths of 8.5 m and 8.0 m, respectively.

A Case Study of Human Thermal Sensation (Comfort) in Plastic Houses (온실시설내 인간 열환경지수(열쾌적성)에 대한 사례연구)

  • Jung, Leeweon;Jin, Younghwan;Jeun, Yoona;Ko, Kyuman;Park, Hyungwook;Park, Sookuk
    • Journal of Environmental Science International
    • /
    • v.25 no.8
    • /
    • pp.1115-1129
    • /
    • 2016
  • To analyze human thermal environments in protected horticultural houses (plastic houses), human thermal sensations estimated using measured microclimatic data (air temperature, humidity, wind speed, and solar and terrestrial radiation) were compared between an outdoor area and two indoor plastic houses, a polyethylene (PE) house and a polycarbonate (PC) house. Measurements were carried out during the daytime in autumn, a transient season that exhibits human thermal environments ranging from neutral to very hot. The mean air temperature and absolute humidity of the houses were $14.6-16.8^{\circ}C$ (max. 22. $3^{\circ}C$) and $7.0-12.0g{\cdot}m^{-3}$ higher than those of the outdoor area, respectively. Solar (K) and terrestrial (L) radiation were compared directionally from the sky hemisphere (${\downarrow}$) and the ground hemisphere (${\uparrow}$). The mean $K{\downarrow}$ and $K{\uparrow}$ values for the houses were respectively $232.5-367.8W{\cdot}m^{-2}$ and $44.9-55.7W;{\cdot}m^{-2}$ lower than those in the outdoor area; the mean $L{\downarrow}$ and $L{\uparrow}$ values were respectively $150.4-182.3W{\cdot}m^{-2}$ and $30.5-33.9W{\cdot}m^{-2}$ higher than those in the outdoor area. Thus, L was revealed to be more influential on the greenhouse effect in the houses than K. Consequently, mean radiant temperature in the houses was higher than the outdoor area during the daytime from 10:45 to 14:15. As a result, mean human thermal sensation values in the PMV, PET, and UTCI of the houses were respectively $3.2-3.4^{\circ}C$ (max. $4.7^{\circ}C$), $15.2-16.4^{\circ}C$ (max. $23.7^{\circ}C$) and $13.6-15.4^{\circ}C$ (max. $22.3^{\circ}C$) higher than those in the outdoor area. The heat stress levels that were influenced by human thermal sensation were much higher in the houses (between hot and very hot) than in the outdoor (between neutral and warm). Further, the microclimatic component that most affected the human thermal sensation in the houses was air temperature that was primarily influenced by $L{\downarrow}$. Therefore, workers in the plastic houses could experience strong heat stresses, equal to hot or higher, when air temperature rose over $22^{\circ}C$ on clear autumn days.

Comparison of analysis methods of estimating behavior of soil mass above rigid culvert (암거 상부지반의 거동 평가를 위한 해석법 비교)

  • Lee, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.71-77
    • /
    • 2018
  • In order to estimate behavior of soil mass which is located straight up of reinforced concrete culvert, Ritz method and FEM were applied and arching effects between the soil mass and adjacent soil were considered for the analyses. Analysis results obtained from the Ritz method and finite element method were compared with analytical solution. In the case of estimating nodal forces considered in FEM, caution is needed that shear stress depending on depth from ground surface should be reflected regardless of local coordinate system. Comparing the displacements computed from Ritz method with those of the analytic solution, it is seen that as the power of assumed displacement function increases, differences between the computed displacements and those of analytic solution decreases. It seems that displacements of FEM becomes closer to those of analytical solution as the number of elements are increased. It is seen that stresses computed from the Ritz method don't get closer to those of the analytic solution as the power of assumed displacement function. Stresses from FEM become closer to those of analytic solution as the number of elements are increased. Comparing the analysis results from the Ritz method and FEM with those of analytic solution, it can be seen that FEM is more reliable than Ritz method.

A Study on the Improvement of Greenhouse Frame to Bear the Heavy Snow (적설하중 증가에 대비한 비닐하우스 골조 성능의 개선 연구)

  • Jung, Hyunjin;Yang, Sanghyun;Lee, Taehee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2242-2248
    • /
    • 2015
  • The damages from greenhouses collapsing due to heavy snowfall in winter are increasing, and the current frames of greenhouse are required to be improved. This study was conducted to seek solutions to improve intensities of greenhouse frame to bear heavy snows. We investigated a structural safety of greenhouses by calculating axial force, bending moment and combined stress when snow load was increased up to 30% of the current standard ground snow load of the conventional greenhouse types (07-single type 3, 07-single type 18) in the three regions (Gyeongju, Sokcho, and Gangneung) where were most damaged by recent heavy snows. In addition, we determined what structural type was most efficiently bear snow loads by measuring the differences between the load bearing strength according to the changes of tube diameter and thickness or the rafter spacing of greenhouses circular pipe. MIDAS GEN program was used in the analysis. As a result, with the snow load increase of 30%, greenhouse in Gyongju was still safe, but in Sokcho was at a risk, and in Gangneung was possible to be collapsed even in the current snow load. Increased pipe diameter than increased pipe thickness was more efficient in terms of improved performance of greenhouse structure. Accordingly, it is suggested to revise standards of greenhouse to increase pipe diameter of rafter for minimizing damages by heavy snow.

A Study on the Assessment of Safety Factor of Tunnels (터널의 안전율 평가 기법에 관한 연구)

  • 박종원;박연준;유광호;이상돈
    • Tunnel and Underground Space
    • /
    • v.14 no.5
    • /
    • pp.327-338
    • /
    • 2004
  • The purpose of this research is to establish a concept of the factor of safety of tunnels which is a quantitative estimate of the stability of tunnels. Based on this concept, a numerical technique which calculates the factor of safety of tunnels was developed. To obtain the safety factor of a tunnel, the strength reduction technique in which a series of analyses are repeated with reduced ground strength until the tunnel collapses were employed. With this technique, the failure plane, as well as the factor of safety, can be obtained without prescribing the trial failure plane. Analyses were conducted with FLA $C^{2D}$(ver3.3), a geotechnical analysis program which is based on the finite difference method. From the result, the location of plastic zones, the maximum convergence and the maximum stress generated in the support system were also analyzed. The result shows that factors of safety are higher for the 1st and 2nd rock classes, and lower for the lower rock classes. Furthermore, factor of safety is higher when $K_{0}$ =0.5 compared to at in case of $K_{0}$ =2.0. Through this research, it is found that the factor of safety defined in this research can be used as a good quantitative index representing the stability of tunnels. Also, close examination of the results can help adjustment of the quantity and location of additional supports.s.

The Slope Stabilization of Solid Waste Landfill Liner System (폐기물매립장의 사면차수체계 안정화 연구)

  • Shin, Eunchul;Kim, Jongin;Park, Jeongjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.3
    • /
    • pp.21-28
    • /
    • 2009
  • As the natural aggregates such as sand and clay are getting exhausted, the quantity of utilizing geosynthetics is being increased in the solid waste landfill. Especially, the waste landfills have been constructed at the gorge in the mountainous area and reclaimed land from the sea in the Korean Peninsula. Those areas are not favorable for construction of waste landfill in geotechnical engineering aspect. In this study, the frictional characteristics of geosynthetics that used in the waste landfill were estimated. Then, the studies of the behavior of geosynthetics and stability of LDCRS (Leachate Detection, Collection, and Removal System) of side slope were conducted in the waste landfill by means of the pilot test, and numerical analysis. Geocomposite which is combined type or separated type is influenced on the strain itself, and also implicated in the stress and strain of geomembrane at the lower layer. The strain on the combined type of geocomposite is about 50% smaller than that of the separated type at the side slope. The lateral displacement and settlement of top at the slope with the separated type are three times greater than that of the combined type. In the numerical analysis, discontinuous plans in between ground and geosynthetic, geosynthetic and geosynthetic, goesynthetic and waste have been modeled with the interface element. The results gave a good agreement with the field large-scale model test. The relative displacements of geosynthetics were also investigated and hence the interface modeling of liner system is appropriate for analysis of geosynthetics liner system in the waste landfill.

  • PDF

Field Pullout Tests and Stability Evaluation of the Pretension Soil Nailing System (프리텐션 쏘일네일링 시스템의 현장인발시험 및 안정성 평가)

  • Kim, Hong-Taek;Choi, Young-Geun;Park, Si-Sam;Kim, Berm-Suk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.3
    • /
    • pp.27-40
    • /
    • 2003
  • In the present study, a newly modified soil nailing technology named as the PSN(Pretension Soil Nailing) system is proposed. Effects of various factors related to the design of the pretension soil nailing system, such as the length of a sheathing pipe and the fixed cone, are examined throughout a series of the displacement-controlled field pull-out tests. 9 displacement-controlled field pull-out tests are performed in the present study and the pretension forces are also evaluated based on the measurements. In addition, both short-term and long-term characteristics of pull-out deformations of the newly proposed PSN system are analyzed and compared with those of the general soil nailing system by carrying out the stress-controlled field pull-out tests. A numerical approach is further made to determine a postulated failure surface as well as a minimum safety factors of the proposed PSN system using the shear strength reduction technique and the $FLAC^{2D}$ program. Global minimum safety factors and local safety factors at various excavation stages computed in case of the PSN system are analyzed throughout comparisons with the results expected in case of the general soil nailing system. An efficiency of the PSN system is also dealt with by analyzing the wall-facing deformations and the adjacent ground surface settlements.

  • PDF